27 resultados para Working Conditions

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Batteries and ultracapacitors for hybrid and electric vehicles must satisfy very demanding working conditions that are not usual in other applications. In this sense, specific tests must be performed in order to draw accurate conclusions about their behaviour. To do so, new advanced test benches are needed. These platforms must allow the study of a wide variety of energy storage systems under conditions similar to the real ones. In this paper, a flexible, low-cost and highly customizable system is presented. This system allows batteries and ultracapacitors to be tested in many and varied ways, effectively emulating the working conditions that they face in an electric vehicle. The platform was specifically designed to study energy storage systems for electric and hybrid vehicles, meaning that it is suitable to test different systems in many different working conditions, including real driving cycles. This flexibility is achieved keeping the cost of the platform low, which makes the proposed test bench a feasible alternative for the industry. As an example of the functionality of the platform, a test consisting of a 17-minute ARTEMIS urban cycle with a NiMH battery pack is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hoy en día, el proceso de un proyecto sostenible persigue realizar edificios de elevadas prestaciones que son, energéticamente eficientes, saludables y económicamente viables utilizando sabiamente recursos renovables para minimizar el impacto sobre el medio ambiente reduciendo, en lo posible, la demanda de energía, lo que se ha convertido, en la última década, en una prioridad. La Directiva 2002/91/CE "Eficiencia Energética de los Edificios" (y actualizaciones posteriores) ha establecido el marco regulatorio general para el cálculo de los requerimientos energéticos mínimos. Desde esa fecha, el objetivo de cumplir con las nuevas directivas y protocolos ha conducido las políticas energéticas de los distintos países en la misma dirección, centrándose en la necesidad de aumentar la eficiencia energética en los edificios, la adopción de medidas para reducir el consumo, y el fomento de la generación de energía a través de fuentes renovables. Los edificios de energía nula o casi nula (ZEB, Zero Energy Buildings ó NZEB, Net Zero Energy Buildings) deberán convertirse en un estándar de la construcción en Europa y con el fin de equilibrar el consumo de energía, además de reducirlo al mínimo, los edificios necesariamente deberán ser autoproductores de energía. Por esta razón, la envolvente del edifico y en particular las fachadas son importantes para el logro de estos objetivos y la tecnología fotovoltaica puede tener un papel preponderante en este reto. Para promover el uso de la tecnología fotovoltaica, diferentes programas de investigación internacionales fomentan y apoyan soluciones para favorecer la integración completa de éstos sistemas como elementos arquitectónicos y constructivos, los sistemas BIPV (Building Integrated Photovoltaic), sobre todo considerando el próximo futuro hacia edificios NZEB. Se ha constatado en este estudio que todavía hay una falta de información útil disponible sobre los sistemas BIPV, a pesar de que el mercado ofrece una interesante gama de soluciones, en algunos aspectos comparables a los sistemas tradicionales de construcción. Pero por el momento, la falta estandarización y de una regulación armonizada, además de la falta de información en las hojas de datos técnicos (todavía no comparables con las mismas que están disponibles para los materiales de construcción), hacen difícil evaluar adecuadamente la conveniencia y factibilidad de utilizar los componentes BIPV como parte integrante de la envolvente del edificio. Organizaciones internacionales están trabajando para establecer las normas adecuadas y procedimientos de prueba y ensayo para comprobar la seguridad, viabilidad y fiabilidad estos sistemas. Sin embargo, hoy en día, no hay reglas específicas para la evaluación y caracterización completa de un componente fotovoltaico de integración arquitectónica de acuerdo con el Reglamento Europeo de Productos de la Construcción, CPR 305/2011. Los productos BIPV, como elementos de construcción, deben cumplir con diferentes aspectos prácticos como resistencia mecánica y la estabilidad; integridad estructural; seguridad de utilización; protección contra el clima (lluvia, nieve, viento, granizo), el fuego y el ruido, aspectos que se han convertido en requisitos esenciales, en la perspectiva de obtener productos ambientalmente sostenibles, saludables, eficientes energéticamente y económicamente asequibles. Por lo tanto, el módulo / sistema BIPV se convierte en una parte multifuncional del edificio no sólo para ser física y técnicamente "integrado", además de ser una oportunidad innovadora del diseño. Las normas IEC, de uso común en Europa para certificar módulos fotovoltaicos -IEC 61215 e IEC 61646 cualificación de diseño y homologación del tipo para módulos fotovoltaicos de uso terrestre, respectivamente para módulos fotovoltaicos de silicio cristalino y de lámina delgada- atestan únicamente la potencia del módulo fotovoltaico y dan fe de su fiabilidad por un período de tiempo definido, certificando una disminución de potencia dentro de unos límites. Existe también un estándar, en parte en desarrollo, el IEC 61853 (“Ensayos de rendimiento de módulos fotovoltaicos y evaluación energética") cuyo objetivo es la búsqueda de procedimientos y metodologías de prueba apropiados para calcular el rendimiento energético de los módulos fotovoltaicos en diferentes condiciones climáticas. Sin embargo, no existen ensayos normalizados en las condiciones específicas de la instalación (p. ej. sistemas BIPV de fachada). Eso significa que es imposible conocer las efectivas prestaciones de estos sistemas y las condiciones ambientales que se generan en el interior del edificio. La potencia nominal de pico Wp, de un módulo fotovoltaico identifica la máxima potencia eléctrica que éste puede generar bajo condiciones estándares de medida (STC: irradición 1000 W/m2, 25 °C de temperatura del módulo y distribución espectral, AM 1,5) caracterizando eléctricamente el módulo PV en condiciones específicas con el fin de poder comparar los diferentes módulos y tecnologías. El vatio pico (Wp por su abreviatura en inglés) es la medida de la potencia nominal del módulo PV y no es suficiente para evaluar el comportamiento y producción del panel en términos de vatios hora en las diferentes condiciones de operación, y tampoco permite predecir con convicción la eficiencia y el comportamiento energético de un determinado módulo en condiciones ambientales y de instalación reales. Un adecuado elemento de integración arquitectónica de fachada, por ejemplo, debería tener en cuenta propiedades térmicas y de aislamiento, factores como la transparencia para permitir ganancias solares o un buen control solar si es necesario, aspectos vinculados y dependientes en gran medida de las condiciones climáticas y del nivel de confort requerido en el edificio, lo que implica una necesidad de adaptación a cada contexto específico para obtener el mejor resultado. Sin embargo, la influencia en condiciones reales de operación de las diferentes soluciones fotovoltaicas de integración, en el consumo de energía del edificio no es fácil de evaluar. Los aspectos térmicos del interior del ambiente o de iluminación, al utilizar módulos BIPV semitransparentes por ejemplo, son aún desconocidos. Como se dijo antes, la utilización de componentes de integración arquitectónica fotovoltaicos y el uso de energía renovable ya es un hecho para producir energía limpia, pero también sería importante conocer su posible contribución para mejorar el confort y la salud de los ocupantes del edificio. Aspectos como el confort, la protección o transmisión de luz natural, el aislamiento térmico, el consumo energético o la generación de energía son aspectos que suelen considerarse independientemente, mientras que todos juntos contribuyen, sin embargo, al balance energético global del edificio. Además, la necesidad de dar prioridad a una orientación determinada del edificio, para alcanzar el mayor beneficio de la producción de energía eléctrica o térmica, en el caso de sistemas activos y pasivos, respectivamente, podría hacer estos últimos incompatibles, pero no necesariamente. Se necesita un enfoque holístico que permita arquitectos e ingenieros implementar sistemas tecnológicos que trabajen en sinergia. Se ha planteado por ello un nuevo concepto: "C-BIPV, elemento fotovoltaico consciente integrado", esto significa necesariamente conocer los efectos positivos o negativos (en términos de confort y de energía) en condiciones reales de funcionamiento e instalación. Propósito de la tesis, método y resultados Los sistemas fotovoltaicos integrados en fachada son a menudo soluciones de vidrio fácilmente integrables, ya que por lo general están hechos a medida. Estos componentes BIPV semitransparentes, integrados en el cerramiento proporcionan iluminación natural y también sombra, lo que evita el sobrecalentamiento en los momentos de excesivo calor, aunque como componente estático, asimismo evitan las posibles contribuciones pasivas de ganancias solares en los meses fríos. Además, la temperatura del módulo varía considerablemente en ciertas circunstancias influenciada por la tecnología fotovoltaica instalada, la radiación solar, el sistema de montaje, la tipología de instalación, falta de ventilación, etc. Este factor, puede suponer un aumento adicional de la carga térmica en el edificio, altamente variable y difícil de cuantificar. Se necesitan, en relación con esto, más conocimientos sobre el confort ambiental interior en los edificios que utilizan tecnologías fotovoltaicas integradas, para abrir de ese modo, una nueva perspectiva de la investigación. Con este fin, se ha diseñado, proyectado y construido una instalación de pruebas al aire libre, el BIPV Env-lab "BIPV Test Laboratory", para la caracterización integral de los diferentes módulos semitransparentes BIPV. Se han definido también el método y el protocolo de ensayos de caracterización en el contexto de un edificio y en condiciones climáticas y de funcionamiento reales. Esto ha sido posible una vez evaluado el estado de la técnica y la investigación, los aspectos que influyen en la integración arquitectónica y los diferentes tipos de integración, después de haber examinado los métodos de ensayo para los componentes de construcción y fotovoltaicos, en condiciones de operación utilizadas hasta ahora. El laboratorio de pruebas experimentales, que consiste en dos habitaciones idénticas a escala real, 1:1, ha sido equipado con sensores y todos los sistemas de monitorización gracias a los cuales es posible obtener datos fiables para evaluar las prestaciones térmicas, de iluminación y el rendimiento eléctrico de los módulos fotovoltaicos. Este laboratorio permite el estudio de tres diferentes aspectos que influencian el confort y consumo de energía del edificio: el confort térmico, lumínico, y el rendimiento energético global (demanda/producción de energía) de los módulos BIPV. Conociendo el balance de energía para cada tecnología solar fotovoltaica experimentada, es posible determinar cuál funciona mejor en cada caso específico. Se ha propuesto una metodología teórica para la evaluación de estos parámetros, definidos en esta tesis como índices o indicadores que consideran cuestiones relacionados con el bienestar, la energía y el rendimiento energético global de los componentes BIPV. Esta metodología considera y tiene en cuenta las normas reglamentarias y estándares existentes para cada aspecto, relacionándolos entre sí. Diferentes módulos BIPV de doble vidrio aislante, semitransparentes, representativos de diferentes tecnologías fotovoltaicas (tecnología de silicio monocristalino, m-Si; de capa fina en silicio amorfo unión simple, a-Si y de capa fina en diseleniuro de cobre e indio, CIS) fueron seleccionados para llevar a cabo una serie de pruebas experimentales al objeto de demostrar la validez del método de caracterización propuesto. Como resultado final, se ha desarrollado y generado el Diagrama Caracterización Integral DCI, un sistema gráfico y visual para representar los resultados y gestionar la información, una herramienta operativa útil para la toma de decisiones con respecto a las instalaciones fotovoltaicas. Este diagrama muestra todos los conceptos y parámetros estudiados en relación con los demás y ofrece visualmente toda la información cualitativa y cuantitativa sobre la eficiencia energética de los componentes BIPV, por caracterizarlos de manera integral. ABSTRACT A sustainable design process today is intended to produce high-performance buildings that are energy-efficient, healthy and economically feasible, by wisely using renewable resources to minimize the impact on the environment and to reduce, as much as possible, the energy demand. In the last decade, the reduction of energy needs in buildings has become a top priority. The Directive 2002/91/EC “Energy Performance of Buildings” (and its subsequent updates) established a general regulatory framework’s methodology for calculation of minimum energy requirements. Since then, the aim of fulfilling new directives and protocols has led the energy policies in several countries in a similar direction that is, focusing on the need of increasing energy efficiency in buildings, taking measures to reduce energy consumption, and fostering the use of renewable sources. Zero Energy Buildings or Net Zero Energy Buildings will become a standard in the European building industry and in order to balance energy consumption, buildings, in addition to reduce the end-use consumption should necessarily become selfenergy producers. For this reason, the façade system plays an important role for achieving these energy and environmental goals and Photovoltaic can play a leading role in this challenge. To promote the use of photovoltaic technology in buildings, international research programs encourage and support solutions, which favors the complete integration of photovoltaic devices as an architectural element, the so-called BIPV (Building Integrated Photovoltaic), furthermore facing to next future towards net-zero energy buildings. Therefore, the BIPV module/system becomes a multifunctional building layer, not only physically and functionally “integrated” in the building, but also used as an innovative chance for the building envelope design. It has been found in this study that there is still a lack of useful information about BIPV for architects and designers even though the market is providing more and more interesting solutions, sometimes comparable to the existing traditional building systems. However at the moment, the lack of an harmonized regulation and standardization besides to the non-accuracy in the technical BIPV datasheets (not yet comparable with the same ones available for building materials), makes difficult for a designer to properly evaluate the fesibility of this BIPV components when used as a technological system of the building skin. International organizations are working to establish the most suitable standards and test procedures to check the safety, feasibility and reliability of BIPV systems. Anyway, nowadays, there are no specific rules for a complete characterization and evaluation of a BIPV component according to the European Construction Product Regulation, CPR 305/2011. BIPV products, as building components, must comply with different practical aspects such as mechanical resistance and stability; structural integrity; safety in use; protection against weather (rain, snow, wind, hail); fire and noise: aspects that have become essential requirements in the perspective of more and more environmentally sustainable, healthy, energy efficient and economically affordable products. IEC standards, commonly used in Europe to certify PV modules (IEC 61215 and IEC 61646 respectively crystalline and thin-film ‘Terrestrial PV Modules-Design Qualification and Type Approval’), attest the feasibility and reliability of PV modules for a defined period of time with a limited power decrease. There is also a standard (IEC 61853, ‘Performance Testing and Energy Rating of Terrestrial PV Modules’) still under preparation, whose aim is finding appropriate test procedures and methodologies to calculate the energy yield of PV modules under different climate conditions. Furthermore, the lack of tests in specific conditions of installation (e.g. façade BIPV devices) means that it is difficult knowing the exact effective performance of these systems and the environmental conditions in which the building will operate. The nominal PV power at Standard Test Conditions, STC (1.000 W/m2, 25 °C temperature and AM 1.5) is usually measured in indoor laboratories, and it characterizes the PV module at specific conditions in order to be able to compare different modules and technologies on a first step. The “Watt-peak” is not enough to evaluate the panel performance in terms of Watt-hours of various modules under different operating conditions, and it gives no assurance of being able to predict the energy performance of a certain module at given environmental conditions. A proper BIPV element for façade should take into account thermal and insulation properties, factors as transparency to allow solar gains if possible or a good solar control if necessary, aspects that are linked and high dependent on climate conditions and on the level of comfort to be reached. However, the influence of different façade integrated photovoltaic solutions on the building energy consumption is not easy to assess under real operating conditions. Thermal aspects, indoor temperatures or luminance level that can be expected using building integrated PV (BIPV) modules are not well known. As said before, integrated photovoltaic BIPV components and the use of renewable energy is already a standard for green energy production, but would also be important to know the possible contribution to improve the comfort and health of building occupants. Comfort, light transmission or protection, thermal insulation or thermal/electricity power production are aspects that are usually considered alone, while all together contribute to the building global energy balance. Besides, the need to prioritize a particular building envelope orientation to harvest the most benefit from the electrical or thermal energy production, in the case of active and passive systems respectively might be not compatible, but also not necessary. A holistic approach is needed to enable architects and engineers implementing technological systems working in synergy. A new concept have been suggested: “C-BIPV, conscious integrated BIPV”. BIPV systems have to be “consciously integrated” which means that it is essential to know the positive and negative effects in terms of comfort and energy under real operating conditions. Purpose of the work, method and results The façade-integrated photovoltaic systems are often glass solutions easily integrable, as they usually are custommade. These BIPV semi-transparent components integrated as a window element provides natural lighting and shade that prevents overheating at times of excessive heat, but as static component, likewise avoid the possible solar gains contributions in the cold months. In addition, the temperature of the module varies considerably in certain circumstances influenced by the PV technology installed, solar radiation, mounting system, lack of ventilation, etc. This factor may result in additional heat input in the building highly variable and difficult to quantify. In addition, further insights into the indoor environmental comfort in buildings using integrated photovoltaic technologies are needed to open up thereby, a new research perspective. This research aims to study their behaviour through a series of experiments in order to define the real influence on comfort aspects and on global energy building consumption, as well as, electrical and thermal characteristics of these devices. The final objective was to analyze a whole set of issues that influence the global energy consumption/production in a building using BIPV modules by quantifying the global energy balance and the BIPV system real performances. Other qualitative issues to be studied were comfort aspect (thermal and lighting aspects) and the electrical behaviour of different BIPV technologies for vertical integration, aspects that influence both energy consumption and electricity production. Thus, it will be possible to obtain a comprehensive global characterization of BIPV systems. A specific design of an outdoor test facility, the BIPV Env-lab “BIPV Test Laboratory”, for the integral characterization of different BIPV semi-transparent modules was developed and built. The method and test protocol for the BIPV characterization was also defined in a real building context and weather conditions. This has been possible once assessed the state of the art and research, the aspects that influence the architectural integration and the different possibilities and types of integration for PV and after having examined the test methods for building and photovoltaic components, under operation conditions heretofore used. The test laboratory that consists in two equivalent test rooms (1:1) has a monitoring system in which reliable data of thermal, daylighting and electrical performances can be obtained for the evaluation of PV modules. The experimental set-up facility (testing room) allows studying three different aspects that affect building energy consumption and comfort issues: the thermal indoor comfort, the lighting comfort and the energy performance of BIPV modules tested under real environmental conditions. Knowing the energy balance for each experimented solar technology, it is possible to determine which one performs best. A theoretical methodology has been proposed for evaluating these parameters, as defined in this thesis as indices or indicators, which regard comfort issues, energy and the overall performance of BIPV components. This methodology considers the existing regulatory standards for each aspect, relating them to one another. A set of insulated glass BIPV modules see-through and light-through, representative of different PV technologies (mono-crystalline silicon technology, mc-Si, amorphous silicon thin film single junction, a-Si and copper indium selenide thin film technology CIS) were selected for a series of experimental tests in order to demonstrate the validity of the proposed characterization method. As result, it has been developed and generated the ICD Integral Characterization Diagram, a graphic and visual system to represent the results and manage information, a useful operational tool for decision-making regarding to photovoltaic installations. This diagram shows all concepts and parameters studied in relation to each other and visually provides access to all the results obtained during the experimental phase to make available all the qualitative and quantitative information on the energy performance of the BIPV components by characterizing them in a comprehensive way.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rotator cuff tears of the shoulder are a common cause of pain and disability. Although surgery is frequently beneficial, re-tearing of the tendons is likely to re-occur. In many cases even if the reparation is successful it will still generate discomfort, problems with mobility, as well as a sharp pain. This project is funded in the cooperation with the Hospital Clinico San Carlos de Madrid. The purpose of this work is to analyze the effect of the surgical repair and the application of different therapies, including mesenchymal stem cell therapy on the biomechanical properties (strength and stiffness) of the repaired tendon. An animal model of rotator cuff tendon reparations has been developed on laboratory rats.To obtain the mechanical response of the healthy and repaired tendons, it was necessary to develop an experimental set up to reproduce the in-vivo working conditions of the tendons (37 ºC, immersed in physiological serum), and especially the load transfer. The biomechanical properties (maximum load and stiffness) have been measured in healthy and repaired tendons. A total of 70 rats are used in this particular study. It has been found that the repaired tendon is stronger than the original on. However, the repaired tendons demonstrate less flexibility than the healthy (original) ones prior to the damage

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Concentrator photovoltaic is an emergent technology that may be a good economical and efficient alternative for the generation of electricity at a competitive cost. However, the reliability of these new solar cells and systems is still an open issue due to the high-irradiation level they are subjected to as well as the electrical and thermal stresses that they are expected to endure. To evaluate the reliability in a short period of time, accelerated aging tests are essential. Thermal aging tests for concentrator photovoltaic solar cells and systems under illumination are not available because no technical solution to the problem of reaching the working concentration inside a climatic chamber has been available. This work presents an automatic instrumentation system that overcomes the aforementioned limitation. Working conditions have been simulated by forward biasing the solar cells to the current they would handle at the working concentration (in this case, 700 and 1050 times the irradiance at one standard sun). The instrumentation system has been deployed for more than 10 000 h in a thermal aging test for III-V concentrator solar cells, in which the generated power evolution at different temperatures has been monitored. As a result of this test, the acceleration factor has been calculated, thus allowing for the degradation evolution at any temperature in addition to normal working conditions to be obtained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Automatic visual object counting and video surveillance have important applications for home and business environments, such as security and management of access points. However, in order to obtain a satisfactory performance these technologies need professional and expensive hardware, complex installations and setups, and the supervision of qualified workers. In this paper, an efficient visual detection and tracking framework is proposed for the tasks of object counting and surveillance, which meets the requirements of the consumer electronics: off-the-shelf equipment, easy installation and configuration, and unsupervised working conditions. This is accomplished by a novel Bayesian tracking model that can manage multimodal distributions without explicitly computing the association between tracked objects and detections. In addition, it is robust to erroneous, distorted and missing detections. The proposed algorithm is compared with a recent work, also focused on consumer electronics, proving its superior performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La mayoría de las estructuras de hormigón pretensadas construidas en los últimos 50 años han demostrado una excelente durabilidad cuando su construcción se realiza atendiendo las recomendaciones de un buen diseño así como una buena ejecución y puesta en obra de la estructura. Este hecho se debe en gran parte al temor que despierta el fenómeno de la corrosión bajo tensión típico de las armaduras de acero de alta resistencia. Menos atención se ha prestado a la susceptibilidad a la corrosión bajo tensión de los anclajes de postensado, posiblemente debido a que se han reportado pocos casos de fallos catastróficos. El concepto de Tolerancia al Daño y la Mecánica de la Fractura en estructuras de Ingeniería Civil ha empezado a incorporarse recientemente en algunas normas de diseño y cálculo de estructuras metálicas, sin embargo, aún está lejos de ser asimilado y empleado habitualmente por los ingenieros en sus cálculos cuando la ocasión lo requiere. Este desconocimiento de los aspectos relacionados con la Tolerancia al Daño genera importantes gastos de mantenimiento y reparación. En este trabajo se ha estudiado la aplicabilidad de los conceptos de la Mecánica de la Fractura a los componentes de los sistemas de postensado empleados en ingeniería civil, empleándolo para analizar la susceptibilidad de las armaduras activas frente a la corrosión bajo tensiones y a la pérdida de capacidad portante de las cabezas de anclajes de postensado debido a la presencia de defectos. Con este objeto se han combinado tanto técnicas experimentales como numéricas. Los defectos superficiales en los alambres de pretensado no se presentan de manera aislada si no que existe una cierta continuidad en la dirección axial así como un elevado número de defectos. Por este motivo se ha optado por un enfoque estadístico, que es más apropiado que el determinístico. El empleo de modelos estadísticos basados en la teoría de valores extremos ha permitido caracterizar el estado superficial en alambres de 5,2 mm de diámetro. Por otro lado la susceptibilidad del alambre frente a la corrosión bajo tensión ha sido evaluada mediante la realización de una campaña de ensayos de acuerdo con la actual normativa que ha permitido caracterizar estadísticamente su comportamiento. A la vista de los resultados ha sido posible evaluar como los parámetros que definen el estado superficial del alambre pueden determinar la durabilidad de la armadura atendiendo a su resistencia frente a la corrosión bajo tensión, evaluada mediante los ensayos que especifica la normativa. En el caso de las cabezas de anclaje de tendones de pretensado, los defectos se presentan de manera aislada y tienen su origen en marcas, arañazos o picaduras de corrosión que pueden producirse durante el proceso de fabricación, transporte, manipulación o puesta en obra. Dada la naturaleza de los defectos, el enfoque determinístico es más apropiado que el estadístico. La evaluación de la importancia de un defecto en un elemento estructural requiere la estimación de la solicitación local que genera el defecto, que permite conocer si el defecto es crítico o si puede llegar a serlo, si es que progresa con el tiempo (por fatiga, corrosión, una combinación de ambas, etc.). En este trabajo los defectos han sido idealizados como grietas, de manera que el análisis quedara del lado de la seguridad. La evaluación de la solicitación local del defecto ha sido calculada mediante el empleo de modelos de elementos finitos de la cabeza de anclaje que simulan las condiciones de trabajo reales de la cabeza de anclaje durante su vida útil. A partir de estos modelos numéricos se ha analizado la influencia en la carga de rotura del anclaje de diversos factores como la geometría del anclaje, las condiciones del apoyo, el material del anclaje, el tamaño del defecto su forma y su posición. Los resultados del análisis numérico han sido contrastados satisfactoriamente mediante la realización de una campaña experimental de modelos a escala de cabezas de anclaje de Polimetil-metacrilato en los que artificialmente se han introducido defectos de diversos tamaños y en distintas posiciones. ABSTRACT Most of the prestressed concrete structures built in the last 50 years have demonstrated an excellent durability when they are constructed in accordance with the rules of good design, detailing and execution. This is particularly true with respect to the feared stress corrosion cracking, which is typical of high strength prestressing steel wires. Less attention, however, has been paid to the stress corrosion cracking susceptibility of anchorages for steel tendons for prestressing concrete, probably due to the low number of reported failure cases. Damage tolerance and fracture mechanics concepts in civil engineering structures have recently started to be incorporated in some design and calculation rules for metallic structures, however it is still far from being assimilated and used by civil engineers in their calculations on a regular basis. This limited knowledge of the damage tolerance basis could lead to significant repair and maintenance costs. This work deals with the applicability of fracture mechanics and damage tolerance concepts to the components of prestressed systems, which are used in civil engineering. Such concepts have been applied to assess the susceptibility of the prestressing steel wires to stress corrosion cracking and the reduction of load bearing capability of anchorage devices due to the presence of defects. For this purpose a combination of experimental work and numerical techniques have been performed. Surface defects in prestressing steel wires are not shown alone, though a certain degree of continuity in the axial direction exist. A significant number of such defects is also observed. Hence a statistical approach was used, which is assumed to be more appropriate than the deterministic approach. The use of statistical methods based in extreme value theories has allowed the characterising of the surface condition of 5.2 mm-diameter wires. On the other hand the stress corrosion cracking susceptibility of the wire has been assessed by means of an experimental testing program in line with the current regulations, which has allowed statistical characterisasion of their performances against stress corrosion cracking. In the light of the test results, it has been possible to evaluate how the surface condition parameters could determine the durability of the active metal armour regarding to its resistance against stress corrosion cracking assessed by means of the current testing regulations. In the case of anchorage devices for steel tendons for prestressing concrete, the damage is presented as point defects originating from dents, scratches or corrosion pits that could be produced during the manufacturing proccess, transport, handling, assembly or use. Due to the nature of these defects, in this case the deterministic approach is more appropriate than the statistical approach. The assessment of the relevancy of defect in a structural component requires the computation of the stress intensity factors, which in turn allow the evaluation of whether the size defect is critical or could become critical with the progress of time (due to fatigue, corrosion or a combination of both effects). In this work the damage is idealised as tiny cracks, a conservative hypothesis. The stress intensity factors have been calculated by means of finite element models of the anchorage representing the real working conditions during its service life. These numeric models were used to assess the impact of some factors on the rupture load of the anchorage, such the anchorage geometry, material, support conditions, defect size, shape and its location. The results from the numerical analysis have been succesfully correlated against the results of the experimental testing program of scaled models of the anchorages in poly-methil methacrylate in which artificial damage in several sizes and locations were introduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

SUMMARY Concentration Photovoltaic Systems (CPV) have been proposed as an alternative to conventional systems. During the last years, there has been a boom of the CPV industry caused by the technological progress in all the elements of the system. and mainly caused by the use of multijunction solar cells based on III-V semiconductors, with efficiencies exceeding to 43%. III-V solar cells have been used with high reliability results in a great number of space missions without concentration. However, there are no previous results regarding their reliability in concentration terrestrial applications, where the working conditions are completely different. This lack of experience, together with the important industrial interest, has generated the need to evaluate the reliability of the cells. For this reason, nowadays there are several research centers around the undertaking this task. The evaluation of the reliability of this type of devices by means of accelerated tests is especially problematic when they work at medium or high concentration, because it is practically impossible to emulate real working conditions of the cell inside climatic chambers. In fact, as far as we know, the results that appear in this Thesis are the first estimating the Activation Energy of the failure mechanism involved, as well as the warranty of the III-V concentrator solar cells tested here. To evaluate the reliability of III-V very high concentrator solar cells by means of accelerated tests, a variety of activities, described in this Thesis have been carried out. The First Part of the memory presents the theoretical part of the Doctoral Thesis. After the Introduction, chapter 2 presents the state of the art in degradation and reliability of CPV systems and solar cells. Chapter 3 introduces some reliability definitions and the application of specific statistical functions to the evaluation of the reliability and parameters. From these functions, important parameters will be calculated to be used later in the experimental results of Thesis. The Second Part of the memory contains the experimental. Chapter 4 shows the types of accelerated tests and the main goals pursuit with them when carried out over CPV systems and solar cells. In order to evaluate quantitatively the reliability of the III-V concentrator solar cells used in these tests, some modifications have been introduced which discussion will be tackled here. Based on this analysis the working plan of the tests carried out in this Doctoral Thesis is presented. Chapter 5 presents a new methodology as well as the necessary instrumentation to carry out the tests described here. This new methodology takes into account the adaptation, improvement and novel techniques needed to test concentrator solar cells. The core of this memory is chapter 6, which presents the results of the characterization of the cells during the accelerated life tests and the analysis of the aforementioned results with the purpose of getting quantitative values of reliability in real working conditions. The acceleration factor of the accelerated life tests, under nominal working conditions has been calculated. Accordingly, the validity of the methodology as well as the calculations based on the reliability assessment, have also been demonstrated. Finally, quantitative values of degradation, reliability and warranty of the solar cells under field nominal working conditions have been calculated. With the development of this Doctoral Thesis the reliability of very high concentrator GaAs solar cells of small area has been evaluated. It is very interesting to generalize the procedures described up to this point to III-V multijunction solar cells of greater area. Therefore, chapter 7 develops this generalization and introduces also a useful thermal modeling by means of finite elements of the test cells’ circuits. In the last chapter, the summary of the results and the main contributions of this Thesis are outlined and future research activities are identified. RESUMEN Los Sistemas Fotovoltaicos de Concentración (SFC) han sido propuestos como una alternativa a los sistemas convencionales de generación de energía. Durante los últimos años ha habido un auge de los SFC debido a las mejoras tecnológicas en todos los elementos del sistema, y principalmente por el uso de células multiunión III-V que superan el 43% de rendimiento. Las células solares III-V han sido utilizadas con elevada fiabilidad en aplicaciones espaciales sin concentración, pero no existe experiencia de su fiabilidad en ambiente terrestre a altos niveles de concentración solar. Esta falta de experiencia junto al gran interés industrial ha generado la necesidad de evaluar la fiabilidad de las células, y actualmente hay un significativo número de centros de investigación trabajando en esta área. La evaluación de la fiabilidad de este tipo de dispositivos mediante ensayos acelerados es especialmente problemática cuando trabajan a media o alta concentración por la casi imposibilidad de emular las condiciones de trabajo reales de la célula dentro de cámaras climáticas. De hecho, que sepamos, en los resultados de esta Tesis se evalúa por primera vez la Energía de Activación del mecanismo de fallo de las células, así como la garantía en campo de las células de concentración III-V analizadas. Para evaluar la fiabilidad de células solares III-V de muy alta concentración mediante ensayos de vida acelerada se han realizado diversas actividades que han sido descritas en la memoria de la Tesis. En la Primera Parte de la memoria se presenta la parte teórica de la Tesis Doctoral. Tras la Introducción, en el capítulo 2 se muestra el estado del arte en degradación y fiabilidad de células y Sistemas Fotovoltaicos de Concentración. En el capítulo 3 se exponen de forma resumida las definiciones de fiabilidad y funciones estadísticas que se utilizan para la evaluación de la fiabilidad y sus parámetros, las cuales se emplearán posteriormente en los ensayos descritos en este Tesis. La Segunda Parte de la memoria es experimental. En el capítulo 4 se describen los tipos y objetivos de los ensayos acelerados actualmente aplicados a SFC y a las células, así como las modificaciones necesarias que permitan evaluar cuantitativamente la fiabilidad de las células solares de concentración III-V. En base a este análisis se presenta la planificación de los trabajos realizados en esta Tesis Doctoral. A partir de esta planificación y debido a la necesidad de adaptar, mejorar e innovar las técnicas de ensayos de vida acelerada para una adecuada aplicación a este tipo de dispositivos, en el capítulo 5 se muestra la metodología empleada y la instrumentación necesaria para realizar los ensayos de esta Tesis Doctoral. El núcleo de la memoria es el capítulo 6, en él se presentan los resultados de caracterización de las células durante los ensayos de vida acelerada y el análisis de dichos resultados con el objetivo de obtener valores cuantitativos de fiabilidad en condiciones reales de trabajo. Se calcula el Factor de Aceleración de los ensayos acelerados con respecto a las condiciones nominales de funcionamiento a partir de la Energía de Activación obtenida, y se demuestra la validez de la metodología y cálculos empleados, que son la base de la evaluación de la fiabilidad. Finalmente se calculan valores cuantitativos de degradación, fiabilidad y garantía de las células en condiciones nominales en campo durante toda la vida de la célula. Con el desarrollo de esta Tesis Doctoral se ha evaluado la fiabilidad de células III-V de área pequeña, pero es muy interesante generalizar los procedimientos aquí desarrollados para las células III-V comerciales de área grande. Por este motivo, en el capítulo 7 se analiza dicha generalización, incluyendo el modelado térmico mediante elementos finitos de los circuitos de ensayo de las células. En el último capítulo se realiza un resume del trabajo y las aportaciones realizadas, y se identifican las líneas de trabajo a emprender en el futuro.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Los sistemas de concentración fotovoltaica (CPV) parecen ser una de las vías más prometedoras para generar electricidad a gran escala a precios competitivos. La investigación actual se centra en aumentar la eficiencia y la concentración de los sistemas para abaratar costes. Al mismo tiempo se investiga sobre la fiabilidad de los diferentes componentes que integran un sistema de concentración, ya que para que los sistemas de concentración sean competitivos es necesario que tengan una fiabilidad al menos similar a los sistemas basados en células de silicio. En la presente tesis doctoral se ha llevado a cabo el estudio de aspectos avanzados de células solares multi-unión diseñadas para trabajar a concentraciones ultra-altas. Para ello, se ha desarrollado un modelo circuital tridimensional distribuido con el que simular el comportamiento de las células solares triple-unión bajo distintas condiciones de funcionamiento, así mismo se ha realizado una caracterización avanzada de este tipo de células para comprender mejor su modo de operación y así poder contribuir a mejorar su eficiencia. Finalmente, se han llevado a cabo ensayos de vida acelerados en células multiunión comerciales para conocer la fiabilidad de este tipo de células solares. Para la simulación de células solares triple-unión se ha desarrollado en la presente tesis doctoral un modelo circuital tridimensinal distribuido el cuál integra una descripción completa de la unión túnel. De este modo, con el modelo desarrollado, hemos podido simular perfiles de luz sobre la célula solar que hacen que la densidad de corriente fotogenerada sea mayor a la densidad de corriente pico de la unión túnel. El modelo desarrollado también contempla la distribución lateral de corriente en las capas semiconductoras que componen y rodean la unión túnel. Por tanto, se ha podido simular y analizar el efecto que tiene sobre el funcionamiento de la célula solar que los concentradores ópticos produzcan perfiles de luz desuniformes, tanto en nivel de irradiancia como en el contenido espectral de la luz (aberración cromática). Con el objetivo de determinar cuáles son los mecanismos de recombinación que están limitando el funcionamiento de cada subcélula que integra una triple-unión, y así intentar reducirlos, se ha llevado a cabo la caracterización eléctrica de células solares monouni ón idénticas a las subcelulas de una triple-unión. También se ha determinado la curva corriente-tensión en oscuridad de las subcélulas de GaInP y GaAs de una célula dobleunión mediante la utilización de un teorema de reciprocidad electro-óptico. Finalmente, se ha analizado el impacto de los diferentes mecanismos de recombinación en el funcionamiento de la célula solar triple-unión en concentración. Por último, para determinar la fiabilidad de este tipo de células, se ha llevado a cabo un ensayo de vida acelerada en temperatura en células solares triple-unión comerciales. En la presente tesis doctoral se describe el diseño del ensayo, el progreso del mismo y los datos obtenidos tras el análisis de los resultados preliminares. Abstract Concentrator photovoltaic systems (CPV) seem to be one of the most promising ways to generate electricity at competitive prices. Nowadays, the research is focused on increasing the efficiency and the concentration of the systems in order to reduce costs. At the same time, another important area of research is the study of the reliability of the different components which make up a CPV system. In fact, in order for a CPV to be cost-effective, it should have a warranty at least similar to that of the systems based on Si solar cells. In the present thesis, we will study in depth the behavior of multijunction solar cells under ultra-high concentration. With this purpose in mind, a three-dimensional circuital distributed model which is able to simulate the behavior of triple-junction solar cells under different working conditions has been developed. Also, an advanced characterization of these solar cells has been carried out in order to better understand their behavior and thus contribute to improving efficiency. Finally, accelerated life tests have been carried out on commercial lattice-matched triple-junction solar cells in order to determine their reliability. In order to simulate triple-junction solar cells, a 3D circuital distributed model which integrates a full description of the tunnel junction has been developed. We have analyzed the behavior of the multijunction solar cell under light profiles which cause the current density photo-generated in the solar cell to be higher than the tunnel junction’s peak current density. The advanced model developed also takes into account the lateral current spreading through the semiconductor layers which constitute and surround the tunnel junction. Therefore, the effects of non-uniform light profiles, in both irradiance and the spectral content produced by the concentrators on the solar cell, have been simulated and analyzed. In order to determine which recombination mechanisms are limiting the behavior of each subcell in a triple-junction stack, and to try to reduce them when possible, an electrical characterization of single-junction solar cells that resemble the subcells in a triplejunction stack has been carried out. Also, the dark I-V curves of the GaInP and GaAs subcells in a dual-junction solar cell have been determined by using an electro-optical reciprocity theorem. Finally, the impact of the different recombination mechanisms on the behavior of the triple-junction solar cell under concentration has been analyzed. In order to determine the reliability of these solar cells, a temperature accelerated life test has been carried out on commercial triple-junction solar cells. In the present thesis, the design and the evolution of the test, as well as the data obtained from the analysis of the preliminary results, are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Traction prediction modelling, a key factor in farm tractor design, has been driven by the need to find the answer to this question without having to build physical prototypes. A wide range of theories and their respective algorithms can be used in such predictions. The “Tractors and Tillage” research team at the Polytechnic University of Madrid, which engages, among others, in traction prediction for farm tractors, has developed a series of programs based on the cone index as the parameter representative of the terrain. With the software introduced in the present paper, written in Visual Basic, slip can be predicted in two- and four-wheel drive tractors using any one of four models. It includes databases for tractors, front tyres, rear tyres and working conditions (soil cone index and drawbar pull exerted). The results can be exported in spreadsheet format.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The new generation jet engines operate at highly demanding working conditions. Such conditions need very precise design which implies an exhaustive study of the engine materials and behaviour in their extreme working conditions. With this purpose, this work intends to describe a numerically-based calibration of the widely-used Johnson–Cook fracture model, as well as its validation through high temperature ballistic impact tests. To do so, a widely-used turbine casing material is studied. This material is the Firth Vickers 535 martensitic stainless steel. Quasi-static tensile tests at various temperatures in a universal testing machine, as well as dynamic tests in a Split Hopkinson Pressure Bar, are carried out at different triaxialities. Using ABAQUS/Standard and LS-DYNA numerical codes, experimental data are matched. This method allows the researcher to obtain critical data of equivalent plastic strain and triaxility, which allows for more precise calibration of the Johnson–Cook fracture model. Such enhancement allows study of the fracture behaviour of the material across its usage temperature range.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this paper is to design a path following control system for a car-like mobile robot using classical linear control techniques, so that it adapts on-line to varying conditions during the trajectory following task. The main advantages of the proposed control structure is that well known linear control theory can be applied in calculating the PID controllers to full control requirements, while at the same time it is exible to be applied in non-linear changing conditions of the path following task. For this purpose the Frenet frame kinematic model of the robot is linearised at a varying working point that is calculated as a function of the actual velocity, the path curvature and kinematic parameters of the robot, yielding a transfer function that varies during the trajectory. The proposed controller is formed by a combination of an adaptive PID and a feed-forward controller, which varies accordingly with the working conditions and compensates the non-linearity of the system. The good features and exibility of the proposed control structure have been demonstrated through realistic simulations that include both kinematics and dynamics of the car-like robot.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A quantitative temperature accelerated life test on sixty GaInP/GaInAs/Ge triple-junction commercial concentrator solar cells is being carried out. The final objective of this experiment is to evaluate the reliability, warranty period, and failure mechanism of high concentration solar cells in a moderate period of time. The acceleration of the degradation is realized by subjecting the solar cells at temperatures markedly higher than the nominal working temperature under a concentrator Three experiments at three different temperatures are necessary in order to obtain the acceleration factor which relates the time at the stress level with the time at nominal working conditions. . However, up to now only the test at the highest temperature has finished. Therefore, we can not provide complete reliability information but we have analyzed the life data and the failure mode of the solar cells inside the climatic chamber at the highest temperature. The failures have been all of them catastrophic. In fact, the solar cells have turned into short circuits. We have fitted the failure distribution to a two parameters Weibull function. The failures are wear-out type. We have observed that the busbar and the surrounding fingers are completely deteriorate

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En todo proceso de desarrollo de un dispositivo electrónico o equipo cabe la necesidad de evaluar la fiabilidad de sus componentes, es decir, cual es el porcentaje de equipos que tras un determinado periodo de vida mantiene todas sus funcionalidades dentro de especificaciones. La evaluación de la fiabilidad mediante ensayos acelerados es la herramienta que permite una estimación de la vida del dispositivo o equipo de forma previa a su comercialización. La cuantificación de la fiabilidad es crítica para identificar los costos de un determinado periodo de garantía, y para ofrecer a los clientes el nivel de calidad deseado. El objetivo de este Proyecto Fin de Carrera, es el diseño de un sistema automático de instrumentación versátil, para la realización y caracterización de ensayos acelerados, el cual nos sirva para abordar una amplia gama de ensayos con los que evaluar la fiabilidad de los dispositivos electrónicos o equipos. Además del uso industrial donde se evaluará la fiabilidad de forma previa a la comercialización, este sistema se podrá emplear en la docencia de esta área, y fundamentalmente para la realización de ensayos acelerados en investigación de dispositivos electrónicos. La versatilidad de nuestro hardware y aplicación software es un punto a favor, ya que con este sistema de instrumentación se pueden realizar numerosos tipos de ensayos acelerados, sin el problema de tener que cambiar toda la instrumentación, cada vez que se quiera realizar otro ensayo distinto. Los componentes que se elijan para realizar el ensayo acelerado, serán sometidos a un estrés (tensión, corriente, humedad, temperatura…) y se podrá ir observando cómo envejecen, lo que nos permite evaluar la vida del dispositivo en un corto periodo, emulando sus condiciones de trabajo, además de estudiar la fiabilidad también se puede identificar como se degradan sus características principales antes del fallo. El Software utilizado en este Proyecto se ha implementado con un lenguaje de programación gráfico para instrumentación, LabVIEW. La aplicación software se explica de manera muy detallada a lo largo de la memoria, para que su uso y adaptación si fuese necesario no suponga ningún problema para el usuario. En la última parte de esta memoria se encuentra la guía de usuario y un ensayo acelerado planteado como ejemplo. Explicaremos como se han interconectado los equipos a los componentes en los que se va a realizar el ensayo y así se comprobará el correcto funcionamiento del software tomando las medidas necesarias. ABTRACT In all process of development of an electronic device or equipment, we have the need to evaluate the reliability of its components, that is to say, what percentage of equipment that after a certain period of life keeps all of its functionalities within specifications. The evaluation of reliability by means of accelerated tests is the tool that allows an estimation of the lifetime of the device or equipment prior to its marketing. The quantification of reliability is critical to identify the costs of a specific warranty period, and to offer customers the desired quality level. The objective of this Thesis is the design of an automatic very versatile instrument for the realization and characterization of accelerated tests, which will help us to address a wide range of tests to assess the reliability of the devices or electronic equipment. In addition to industrial use where test the reliability before its commercialization, use it can be used in teaching of this area, fundamentally for the realization of accelerated testing in the investigation of electronic devices. The versatility of our hardware and software implementation is a plus, given that this instrumentation system can perform numerous types of accelerated tests, without the problem to have to change everything, every time you want to make another different test. The components that will be chosen to perform the accelerated test, will be subjected to stress (voltage, current, humidity, temperature ...) and you can observe how they age, allowing us to evaluate the life of the device in a short period, emulating their working conditions. In addition to studying the reliability it can also identify how its main characteristics are degraded before failure. The software used in this Thesis has been implemented with a graphical programming language for instrumentation, LabVIEW. This software is explained in great detail throughout the Thesis, so that its use and adaptation, if necessary, will not be a problem for the user. In the last part of this memory we will expose a user guide and test that we have done. We will explain how the equipment has been interconnected to the components in which we are going to perform the test and so we will check the correct operation of the software taking the necessary measures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study of the performance of an innovative receiver for linear Fresnel reflectors is carried out in this paper, and the results are analyzed with a physics perspective of the process. The receiver consists of a bundle of tubes parallel to the mirror arrays, resulting on a smaller cross section for the same receiver width as the number of tubes increases, due to the diminution of their diameter. This implies higher heat carrier fluid speeds, and thus, a more effective heat transfer process, although it conveys higher pumping power as well. Mass flow is optimized for different tubes diameters, different impinging radiation intensities and different fluid inlet temperatures. It is found that the best receiver design, namely the tubes diameter that maximizes the exergetic efficiency for given working conditions, is similar for the cases studied. There is a range of tubes diameters that imply similar efficiencies, which can drive to capital cost reduction thanks to the flexibility of design. In addition, the length of the receiver is also optimized, and it is observed that the optimal length is similar for the working conditions considered. As a result of this study, it is found that this innovative receiver provides an optimum design for the whole day, even though impinging radiation intensity varies notably. Thermal features of this type of receiver could be the base of a new generation of concentrated solar power plants with a great potential for cost reduction, because of the simplicity of the system and the lower weigh of the components, plus the flexibility of using the receiver tubes for different streams of the heat carrier fluid.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta Tesis Doctoral presenta las investigaciones y los trabajos desarrollados durante los años 2008 a 2012 para el análisis y diseño de un patrón primario de ruido térmico de banda ancha en tecnología coaxial. Para ubicar esta Tesis en su campo científico es necesario tomar conciencia de que la realización de mediciones fiables y trazables forma parte del sostenimiento del bienestar de una sociedad moderna y juega un papel crítico en apoyo de la competitividad económica, la fabricación y el comercio, así como de la calidad de vida. En el mundo moderno actual, una infraestructura de medición bien desarrollada genera confianza en muchas facetas de nuestra vida diaria, porque nos permite el desarrollo y fabricación de productos fiables, innovadores y de alta calidad; porque sustenta la competitividad de las industrias y su producción sostenible; además de contribuir a la eliminación de barreras técnicas y de dar soporte a un comercio justo, garantizar la seguridad y eficacia de la asistencia sanitaria, y por supuesto, dar respuesta a los grandes retos de la sociedad moderna en temas tan complicados como la energía y el medio ambiente. Con todo esto en mente se ha desarrollado un patrón primario de ruido térmico con el fin de aportar al sistema metrológico español un nuevo patrón primario de referencia capaz de ser usado para desarrollar mediciones fiables y trazables en el campo de la medida y calibración de dispositivos de ruido electromagnético de radiofrecuencia y microondas. Este patrón se ha planteado para que cumpla en el rango de 10 MHz a 26,5 GHz con las siguientes especificaciones: Salida nominal de temperatura de ruido aproximada de ~ 83 K. Incertidumbre de temperatura de ruido menor que ± 1 K en todo su rango de frecuencias. Coeficiente de reflexión en todo su ancho de banda de 0,01 a 26,5 GHz lo más bajo posible. Se ha divido esta Tesis Doctoral en tres partes claramente diferenciadas. La primera de ellas, que comprende los capítulos 1, 2, 3, 4 y 5, presenta todo el proceso de simulaciones y ajustes de los parámetros principales del dispositivo con el fin de dejar definidos los que resultan críticos en su construcción. A continuación viene una segunda parte compuesta por el capítulo 6 en donde se desarrollan los cálculos necesarios para obtener la temperatura de ruido a la salida del dispositivo. La tercera y última parte, capítulo 7, se dedica a la estimación de la incertidumbre de la temperatura de ruido del nuevo patrón primario de ruido obtenida en el capítulo anterior. Más concretamente tenemos que en el capítulo 1 se hace una exhaustiva introducción del entorno científico en donde se desarrolla este trabajo de investigación. Además se detallan los objetivos que se persiguen y se presenta la metodología utilizada para conseguirlos. El capítulo 2 describe la caracterización y selección del material dieléctrico para el anillo del interior de la línea de transmisión del patrón que ponga en contacto térmico los dos conductores del coaxial para igualar las temperaturas entre ambos y mantener la impedancia característica de todo el patrón primario de ruido. Además se estudian las propiedades dieléctricas del nitrógeno líquido para evaluar su influencia en la impedancia final de la línea de transmisión. En el capítulo 3 se analiza el comportamiento de dos cargas y una línea de aire comerciales trabajando en condiciones criogénicas. Se pretende con este estudio obtener la variación que se produce en el coeficiente de reflexión al pasar de temperatura ambiente a criogénica y comprobar si estos dispositivos resultan dañados por trabajar a temperaturas criogénicas; además se estudia si se modifica su comportamiento tras sucesivos ciclos de enfriamiento – calentamiento, obteniendo una cota de la variación para poder así seleccionar la carga que proporcione un menor coeficiente de reflexión y una menor variabilidad. En el capítulo 4 se parte del análisis de la estructura del anillo de material dieléctrico utilizada en la nota técnica NBS 1074 del NIST con el fin de obtener sus parámetros de dispersión que nos servirán para calcular el efecto que produce sobre el coeficiente de reflexión de la estructura coaxial completa. Además se realiza un estudio posterior con el fin de mejorar el diseño de la nota técnica NBS 1074 del NIST, donde se analiza el anillo de material dieléctrico, para posteriormente realizar modificaciones en la geometría de la zona donde se encuentra éste con el fin de reducir la reflexión que produce. Concretamente se estudia el ajuste del radio del conductor interior en la zona del anillo para que presente la misma impedancia característica que la línea. Y para finalizar se obtiene analíticamente la relación entre el radio del conductor interior y el radio de la transición de anillo térmico para garantizar en todo punto de esa transición la misma impedancia característica, manteniendo además criterios de robustez del dispositivo y de fabricación realistas. En el capítulo 5 se analiza el comportamiento térmico del patrón de ruido y su influencia en la conductividad de los materiales metálicos. Se plantean las posibilidades de que el nitrógeno líquido sea exterior a la línea o que éste penetre en su interior. En ambos casos, dada la simetría rotacional del problema, se ha simulado térmicamente una sección de la línea coaxial, es decir, se ha resuelto un problema bidimensional, aunque los resultados son aplicables a la estructura real tridimensional. Para la simulación térmica se ha empleado la herramienta PDE Toolbox de Matlab®. En el capítulo 6 se calcula la temperatura de ruido a la salida del dispositivo. Se parte del estudio de la aportación a la temperatura de ruido final de cada sección que compone el patrón. Además se estudia la influencia de las variaciones de determinados parámetros de los elementos que conforman el patrón de ruido sobre las características fundamentales de éste, esto es, el coeficiente de reflexión a lo largo de todo el dispositivo. Una vez descrito el patrón de ruido electromagnético se procede, en el capítulo 7, a describir los pasos seguidos para estimar la incertidumbre de la temperatura de ruido electromagnético a su salida. Para ello se utilizan dos métodos, el clásico de la guía para la estimación de la incertidumbre [GUM95] y el método de simulación de Monte Carlo. En el capítulo 8 se describen las conclusiones y lo logros conseguidos. Durante el desarrollo de esta Tesis Doctoral se ha obtenido un dispositivo novedoso susceptible de ser patentado, que ha sido registrado en la Oficina Española de Patentes y Marcas (O.E.P.M.) en Madrid, de conformidad con lo establecido en el artículo 20 de la Ley 11/1986, de 20 de Marzo, de Patentes, con el título Patrón Primario de Ruido Térmico de Banda Ancha (Referencia P-101061) con fecha 7 de febrero de 2011. ABSTRACT This Ph. D. work describes a number of investigations that were performed along the years 2008 to 2011, as a preparation for the study and design of a coaxial cryogenic reference noise standard. Reliable and traceable measurement underpins the welfare of a modern society and plays a critical role in supporting economic competitiveness, manufacturing and trade as well as quality of life. In our modern world, a well developed measurement infrastructure gives confidence in many aspects of our daily life, for example by enabling the development and manufacturing of reliable, high quality and innovative products; by supporting industry to be competitive and sustainable in its production; by removing technical barriers to trade and supporting fair trade; by ensuring safety and effectiveness of healthcare; by giving response to the major challenges in key sectors such energy and environment, etc. With all this in mind we have developed a primary standard thermal noise with the aim of providing the Spanish metrology system with a new primary standard for noise reference. This standard will allow development of reliable and traceable measurements in the field of calibration and measurement of electromagnetic noise RF and microwave devices. This standard has been designed to work in the frequency range from 10 MHz to 26.5 GHz, meeting the following specifications: 1. Noise temperature output is to be nominally ~ 83 K. 2. Noise temperature uncertainty less than ± 1 K in the frequency range from 0.01 to 26.5 GHz. 3. Broadband performance requires as low a reflection coefficient as possible from 0.01 to 26.5 GHz. The present Ph. D. work is divided into three clearly differentiated parts. The first one, which comprises Chapters 1 to 5, presents the whole process of simulation and adjustment of the main parameters of the device in order to define those of them which are critical for the manufacturing of the device. Next, the second part consists of Chapter 6 where the necessary computations to obtain the output noise temperature of the device are carried out. The third and last part, Chapter 7, is devoted to the estimation of the uncertainty related to the noise temperature of the noise primary standard as obtained in the preceding chapter. More specifically, Chapter 1 provides a thorough introduction to the scientific and technological environment where this research takes place. It also details the objectives to be achieved and presents the methodology used to achieve them. Chapter 2 describes the characterization and selection of the bead dielectric material inside the transmission line, intended to connect the two coaxial conductors equalizing the temperature between the two of them and thus keeping the characteristic impedance constant for the whole standard. In addition the dielectric properties of liquid nitrogen are analyzed in order to assess their influence on the impedance of the transmission line. Chapter 3 analyzes the behavior of two different loads and of a commercial airline when subjected to cryogenic working conditions. This study is intended to obtain the variation in the reflection coefficient when the temperature changes from room to cryogenic temperature, and to check whether these devices can be damaged as a result of working at cryogenic temperatures. Also we try to see whether the load changes its behavior after successive cycles of cooling / heating, in order to obtain a bound for the allowed variation of the reflection coefficient of the load. Chapter 4 analyzes the ring structure of the dielectric material used in the NBS technical note 1074 of NIST, in order to obtain its scattering parameters that will be used for computation of its effect upon the reflection coefficient of the whole coaxial structure. Subsequently, we perform a further investigation with the aim of improving the design of NBS technical note 1074 of NIST, and modifications are introduced in the geometry of the transition area in order to reduce the reflection it produces. We first analyze the ring, specifically the influence of the radius of inner conductor of the bead, and then make changes in its geometry so that it presents the same characteristic impedance as that of the line. Finally we analytically obtain the relationship between the inner conductor radius and the radius of the transition from ring, in order to ensure the heat flow through the transition thus keeping the same reflection coefficient, and at the same time meeting the robustness requirements and the feasibility of manufacturing. Chapter 5 analyzes the thermal behavior of the noise standard and its influence on the conductivity of metallic materials. Both possibilities are raised that the liquid nitrogen is kept outside the line or that it penetrates inside. In both cases, given the rotational symmetry of the structure, we have simulated a section of coaxial line, i.e. the equivalent two-dimensional problem has been resolved, although the results are applicable to the actual three-dimensional structure. For thermal simulation Matlab™ PDE Toolbox has been used. In Chapter 6 we compute the output noise temperature of the device. The starting point is the analysis of the contribution to the overall noise temperature of each section making up the standard. Moreover the influence of the variations in the parameters of all elements of the standard is analyzed, specifically the variation of the reflection coefficient along the entire device. Once the electromagnetic noise standard has been described and analyzed, in Chapter 7 we describe the steps followed to estimate the uncertainty of the output electromagnetic noise temperature. This is done using two methods, the classic analytical approach following the Guide to the Estimation of Uncertainty [GUM95] and numerical simulations made with the Monte Carlo method. Chapter 8 discusses the conclusions and achievements. During the development of this thesis, a novel device was obtained which was potentially patentable, and which was finally registered through the Spanish Patent and Trademark Office (SPTO) in Madrid, in accordance with the provisions of Article 20 of Law 11/1986 about Patents, dated March 20th, 1986. It was registered under the denomination Broadband Thermal Noise Primary Standard (Reference P-101061) dated February 7th, 2011.