3 resultados para White, Joseph, 1712 or 13-1777.

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aboveground tropical tree biomass and carbon storage estimates commonly ignore tree height (H). We estimate the effect of incorporating H on tropics-wide forest biomass estimates in 327 plots across four continents using 42 656 H and diameter measurements and harvested trees from 20 sites to answer the following questions: 1. What is the best H-model form and geographic unit to include in biomass models to minimise site-level uncertainty in estimates of destructive biomass? 2. To what extent does including H estimates derived in (1) reduce uncertainty in biomass estimates across all 327 plots? 3. What effect does accounting for H have on plot- and continental-scale forest biomass estimates? The mean relative error in biomass estimates of destructively harvested trees when including H (mean 0.06), was half that when excluding H (mean 0.13). Power- andWeibull-H models provided the greatest reduction in uncertainty, with regional Weibull-H models preferred because they reduce uncertainty in smaller-diameter classes (?40 cm D) that store about one-third of biomass per hectare in most forests. Propagating the relationships from destructively harvested tree biomass to each of the 327 plots from across the tropics shows that including H reduces errors from 41.8Mgha?1 (range 6.6 to 112.4) to 8.0Mgha?1 (?2.5 to 23.0). For all plots, aboveground live biomass was ?52.2 Mgha?1 (?82.0 to ?20.3 bootstrapped 95%CI), or 13%, lower when including H estimates, with the greatest relative reductions in estimated biomass in forests of the Brazilian Shield, east Africa, and Australia, and relatively little change in the Guiana Shield, central Africa and southeast Asia. Appreciably different stand structure was observed among regions across the tropical continents, with some storing significantly more biomass in small diameter stems, which affects selection of the best height models to reduce uncertainty and biomass reductions due to H. After accounting for variation in H, total biomass per hectare is greatest in Australia, the Guiana Shield, Asia, central and east Africa, and lowest in eastcentral Amazonia, W. Africa, W. Amazonia, and the Brazilian Shield (descending order). Thus, if tropical forests span 1668 million km2 and store 285 Pg C (estimate including H), then applying our regional relationships implies that carbon storage is overestimated by 35 PgC (31?39 bootstrapped 95%CI) if H is ignored, assuming that the sampled plots are an unbiased statistical representation of all tropical forest in terms of biomass and height factors. Our results show that tree H is an important allometric factor that needs to be included in future forest biomass estimates to reduce error in estimates of tropical carbon stocks and emissions due to deforestation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El objetivo del PFC es el diseño e implementación de una aplicación que funcione como osciloscopio, analizador de espectro y generador de funciones virtual, todo dentro de la misma aplicacion. Mediante una tarjeta de adquisición de datos tomaremos muestras de señales del mundo real (sistema analógico) para generar datos que puedan ser manipulados por un ordenador (sistema digital). Con esta misma tarjeta también se podrán generar señales básicas, tales como señales senoidales, cuadradas.... y además se ha añadido la funcionalidad de generar señales moduladas en frecuencia, señales tipo Chirp (usadas comúnmente tanto en aplicaciones sonar y radar, como en transmisión óptica) o PRN (ruido pseudo-aleatorio que consta de una secuencia determinista de pulsos que se repite cada periodo, usada comúnmente en receptores GPS), como también señales ampliamente conocidas como el ruido blanco Gaussiano o el ruido blanco uniforme. La aplicación mostrará con detalle las señales adquiridas y analizará de diversas maneras esas señales. Posee la función de enventanado de los tipos de ventana mas comunes, respuesta en frecuencia, transformada de Fourier, etc. La configuración es elegida por el usuario en un entorno amigable y de visualización atractiva. The objective of the PFC is the design and implementation of an application that works as oscilloscope, spectrum analyzer and virtual signal generator, all within the same application. Through a data acquisition card, the user can take samples of real-world signals (analog system) to generate data that can be manipulated by a computer (digital system). This same card can also generate basic signals, such as sine waves, square waves, sawtooth waves.... and further has added other functionalities as frequency modulated signals generation, Chirp signals type generation (commonly used in both sonar and radar applications, such as optical transmission) or PRN (pseudo-random noise sequence comprising a deterministic pulse that repeats every period, commonly used in GPS receivers). It also can generate widely known as Gaussian white noise signals or white noise uniform signals. The application will show in detail the acquired signals and will analyze these signals in different ways selected by the user. Windowing function has the most common window types, frequency response, Fourier transform are examples of what kind of analyzing that can be processed. The configuration is chosen by the user throught friendly and attractive displays and panels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Component-based diagnosis on multiplex platforms is widely used in food allergy but its clinical performance has not been evaluated in nut allergy. Objective: To assess the diagnostic performance of a commercial protein microarray in the determination of specific IgE (sIgE) in peanut, hazelnut, and walnut allergy. Methods: sIgE was measured in 36 peanut-allergic, 36 hazelnut-allergic, and 44 walnut-allergic patients by ISAC 112, and subsequently, sIgE against available components was determined by ImmunoCAP in patients with negative ISAC results. ImmunoCAP was also used to measure sIgE to Ara h 9, Cor a 8, and Jug r 3 in a subgroup of lipid transfer protein (LTP)-sensitized nut-allergic patients (positive skin prick test to LTP-enriched extract). sIgE levels by ImmunoCAP were compared with ISAC ranges. Results: Most peanut-, hazelnut-, and walnut-allergic patients were sensitized to the corresponding nut LTP (Ara h 9, 66.7%; Cor a 8, 80.5%; Jug r 3, 84% respectively). However, ISAC did not detect sIgE in 33.3% of peanut-allergic patients, 13.9% of hazelnut-allergic patients, or 13.6% of walnut-allergic patients. sIgE determination by ImmunoCAP detected sensitization to Ara h 9, Cor a 8, and Jug r 3 in, respectively, 61.5% of peanut-allergic patients, 60% of hazelnut-allergic patients, and 88.3% of walnut-allergic patients with negative ISAC results. In the subgroup of peach LTP?sensitized patients, Ara h 9 sIgE was detected in more cases by ImmunoCAP than by ISAC (94.4% vs 72.2%, P<.05). Similar rates of Cor a 8 and Jug r 3 sensitization were detected by both techniques. Conclusions: The diagnostic performance of ISAC was adequate for hazelnut and walnut allergy but not for peanut allergy. sIgE sensitivity against Ara h 9 in ISAC needs to be improved.