65 resultados para Vigas de concreto armado

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

El presente trabajo se refiere al estudio teórico-experimental del comportamiento de pilares y vigas de hormigón armado reforzados con fibra de carbono o CFRP. El análisis se realiza considerando que los pilares se refuerzan mediante la técnica de adhesión de tejidos de fibra de carbono, generando un efecto de confinamiento. Las vigas se refuerzan mediante la incorporación de barras del mismo material, con refuerzos a cortante. El objetivo es poder comparar el estudio analítico de este tipo de refuerzos con resultados experimentales obtenidos con anterioridad a la realización de este documento, y así poder obtener conclusiones de las posibles diferencias. Hay que señalar que los modelos experimentales no forman parte de este estudio. Los ensayos en pilares fueron realizados en sección cuadrada y circular evaluando la rotura a compresión de las piezas, habiendo sido éstas escaladas con un factor de reducción de 2,3. Los ensayos correspondientes a vigas se realizaron en sección rectangular, centrándose en la evaluación de la rotura a flexión y habiendo sido escaladas igualmente, pero con un factor de reducción de 1:2. El documento se estructura en cuatro capítulos, cuyo contenido se expone de forma concisa a continuación. En el capítulo uno o marco teórico se exponen los principios de comportamiento y tipologías de los pilares y vigas de hormigón armado, las bases teóricas de su refuerzo y confinamiento, así como las diversas técnicas de refuerzo existentes. Se detalla la técnica con FRP, comparando y analizando sus ventajas e inconvenientes. En el capítulo dos se expone el proceso de fabricación, refuerzo y resultados de los modelos experimentales realizados para ambos elementos estructurales. La obtención de los modelos teóricos forma parte del capítulo tres, comparándose con los resultados experimentales en el cuarto capítulo. Finalmente, en el último capítulo se presentan las conclusiones obtenidas al realizar esta comparativa en el refuerzo de vigas y pilares con fibra de carbono. This work refers to the theoretical and experimental study of the behavior of CFRP reinforced concrete columns and beams. The analysis was done considering that the pillars are reinforced by CFRP wrapping technique, resulting in a confinement effect. The beams are reinforced by the addition of bars of the same material, with shear reinforcements. The objective is to compare the analytical study of this type of reinforcement with experimental results obtained prior to the performance of this document, and draw conclusions for any differences. Notice that experimental models are not part of this study. The tests were performed on circular and square section pillars, evaluating compression fracture of the pieces, having been scaled down with a factor of 2.3. The tests were performed on rectangular section beams, focusing on evaluation of the bending fracture and being scaled down equally, but with a factor of 1:2. The document is divided into four chapters, whose content is set out concisely below. The chapter one or theoretical framework sets out the principles of behavior and types of columns and beams of reinforced concrete, the theoretical basis of its reinforcement and confinement, as well as various existing reinforcement techniques. CFRP technique it’s detailed, comparing and analyzing their advantages and disadvantages. Chapter two describes the process of manufacture, reinforcement and results of experimental models made for both structural elements. Chapter three shows the obtaining of the theoretical models, comparing them with the experimental results in the fourth chapter. Finally, the last chapter presents the conclusions to make this comparison in the strengthening of beams and columns with carbon fiber.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los polímeros armados con fibras (FRP) se utilizan en refuerzos de estructuras de hormigón debido sobre todo a sus excelentes propiedades mecánicas, su resistencia a la corrosión y a su ligereza que se traduce en facilidad y ahorro en el transporte, puesta en obra y aplicación, la cual se realiza de forma muy rápida, con pocos operarios y utilizando medios auxiliares ligeros, minimizándose las interrupciones del uso de la estructura y las molestias a los usuarios. Las razones presentadas anteriormente, han despertado un gran inter´es por parte de diferentes grupos de investigación a nivel mundial y que actualmente se encuentran desarrollando nuevas técnicas de aplicación y métodos de cálculo. Sin embargo, las investigaciones realizadas hasta la fecha, muestran un procedimiento bien definido y aceptado en lo referente al cálculo a flexión, lo cual no ocurre con el refuerzo a cortante y aunque se ha demostrado que el refuerzo con FRP es un sistema eficaz para incrementar la capacidad ´ultima frente a esfuerzos cortantes, también se pone de manifiesto la necesidad de más estudios experimentales y teóricos para avanzar en el entendimiento de los mecanismos involucrados para este tipo de refuerzo y establecer un procedimiento de diseño apropiado que maximice las excelentes propiedades de este material. Los modelos que explican el comportamiento del refuerzo a cortante de elementos de hormigón armado son complejos y sin transposición directa a fórmulas ingenieriles. Las normas actualmente en vigor, generalmente, establecen empíricamente la capacidad cortante como la suma de las capacidades del hormigón y el refuerzo transversal de acero. Cuando un elemento es reforzado externamente con FRP, los modelos son evidentemente aun más complejos. Las guías y recomendaciones existentes proponen calcular la capacidad del elemento añadiendo la resistencia aportada por el refuerzo externo de FRP a la ya dada por el hormigón y acero transversal. Sin embargo, la idoneidad de este acercamiento es cuestionable puesto que no tiene en cuenta una posible interacción entre refuerzos. Con base en lo anterior se da origen al tema objeto de este trabajo, el cual está orientado al estudio a cortante de elementos de hormigón armado (HA), reforzados externamente con material compuesto de tejido unidireccional de fibra de carbono y resina epoxi. Inicialmente se hace una completa revisión del estado actual del conocimiento de la resistencia a cortante en elementos de hormigón armado con y sin refuerzo externo de FRP, prestando especial atención en los mecanismos actuantes estudiados hasta la fecha. La bibliografía consultada ha sido exhaustiva y actualizada lo que ha permitido el estudio de los modelos propuestos más importantes, tanto para la descripción del fenómeno de adherencia entre hormigón-FRP como de la valoración del aporte al cortante total hecho por el FRP, a través de sendas bases de datos de ensayos de pull-out y de vigas de hormigón armado ensayadas a cortante. Con base en todo lo anterior, se expusieron los mecanismos actuantes en el aporte a cortante hecho por el FRP en elementos de hormigón armado y la forma como las principales guías de cálculo existentes hasta la fecha los abordan. De igual forma se define un modelo de resistencia de esfuerzos para el FRP y se proponen dos modelos para el cálculo de las tensiones o deformaciones efectivas, de los cuales uno esta basado en el modelo de adherencia propuesto por Oller (2005) y el otro en una regresión multivariante para los mecanismos expuestos. Como complemento del estudio de los trabajos encontrados en la literatura, se lleva acabo un programa experimental que, además de aportar más registros a la exigua base de datos existentes, aporte mayor luz a los puntos que se consideran están deficientemente resueltos. Dentro de este programa se realizaron 32 ensayos sobre 16 vigas de 4.5 m de longitud (dos ensayos por viga), reforzadas a cortante con tejido unidireccional de CFRP. Finalmente, estos estudios han permitido proponer modificaciones a las formulaciones existentes en los códigos y guías en vigor. Abstract Its excellent mechanical properties, as well as its corrosion resistance and light weight, which make it easy to apply and inexpensive to ship to the worksite, are the basis of the extended use of fiber reinforced polymer (FRP) as external strengthening for structures. FRP strengthening is a rapid operation calling for only limited labor and lightweight ancillary equipment, all of which minimizes both the interruption of facility usage and user inconvenience. These advantages have aroused considerable interest in civil engineering science and technology and have led to countless applications the world over. Research studies on the shear strength of FRP-strengthened members have been much fewer in number and more controversial than the research on flexural strengthening, for which a more or less standardized and generally accepted procedure has been established. The research conducted and a host of applications around the world have shown that FRP strengthening is an effective technique for raising ultimate shear strength, but it has also revealed a need for further experimental and theoretical research to advance in the understanding of the mechanisms involved and establish suitable design procedures that optimize the excellent properties of this material The models that explain reinforced concrete (RC) shear strength behavior are complex and cannot be directly transposed to engineering formulas. The standards presently in place generally establish shear capacity empirically as the sum of the capacities of the concrete and the passive reinforcement. When members are externally strengthened with FRP, the models are obviously even more complex. The existing guides and recommendations propose calculating capacity by adding the external strength provided by the FRP to the contributions of the concrete and passive reinforcement. The suitability of this approach is questionable, however, because it fails to consider the interaction between passive reinforcement and external strengthening. The subject of this work is based in above, which is focused on externally shear strengthening for reinforced concrete members with unidirectional carbon fiber sheets bonded with epoxy resin. v Initially a thorough literature review on shear of reinforced concrete beams with and without external FRP strengthening was performed, paying special attention to the acting mechanisms studied to date, which allowed the study of the most important models both to describe the bond phenomenon as well as calculating the FRP shear contribution, through separate databases of pull-out tests and shear tests on reinforced concrete beams externally strengthened with FRP. Based on above, they were exposed the acting mechanisms in a FRP shear strengthening on reinforced concrete beams and how guidelines deal the topic. The same way, it is defined a FRP stress strength model and two more models are proposed for calculating the effective stress, one of these is based on the Oller (2005) bond model and another one is the data best fit, taking into account most of the acting mechanisms. To complement the theoretical part we develop an experimental program that, in addition to providing more records to the meager existing database provide greater understanding to the points considered poorly resolved. The test program included 32 tests of 16 beams (2 per beam) of 4.5 m long, shear strengthened with FRP, externally. Finally, modifications to the existing codes and guidelines are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gran parte de los edificios e infraestructuras que son susceptibles de ser objeto de un atentado terrorista están sustentados por una estructura portante de hormigón armado. El comportamiento de estructuras de hormigón armado está bien caracterizado ante solicitaciones estáticas, por el contrario, existen todavía incertidumbres sobre el comportamiento ante cargas impulsivas como la que provoca una explosión. Por este motivo en este trabajo se estudia un mismo esquema estructural ante dos solicitaciones de distinta velocidad de deformación, con el objeto de comprobar su influencia en el modo de fallo de la estructura. Se parte de una campaña experimental desarrollada por la Agencia de Defensa de Suecia sobre vigas de hormigón armado de alta resistencia, a partir de la cual se desarrollan estudios analíticos y simulaciones numéricas. Se comprueba que ante carga impulsiva las vigas tienen una resistencia mayor que ante carga estática, si bien con cuantías altas de armado pueden presentarse modos de fallo frágiles, lo que debe ser tenido en cuenta en el diseño de estructuras de hormigón armado para que sean seguras ante explosiones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El refuerzo de elementos estructurales sometidos a flexión mediante la utilización de barras (FRP) pretensadas es una técnica novedosa. En el presente trabajo se describe una nueva técnica para efectuar dicho pretensado. Se describen además los resultados obtenidos en una campaña de ensayos con 9 vigas: 3 probetas sin refuerzo, 3 probetas con refuerzo pasivo y 3 probetas con refuerzo activo. Para conseguir una rotura a flexión las vigas fueron reforzadas a cortante con unos anillos de tejido de fibra de carbono. La rotura de las vigas testigo fue dúctil, y las vigas reforzadas rompieron a cortante de forma explosiva. El pretensado de los elementos de refuerzo permitió incrementar la capacidad resistente de las vigas un 170% respecto de la viga testigo, produciéndose además un aumento en la rigidez de los elementos reforzados y una disminución en la fisuración de la viga. Se detectaron deficiencias en la técnica de refuerzo empleada, derivadas principalmente del método de aplicación del adhesivo estructural, que se propone mejorar en próximos trabajos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Una técnica de refuerzo de elementos flectados en general y, en particular, de vigas y forjados de hormigón armado, consiste en la disposición de perfiles metálicos por debajo de los elementos a reforzar y retacados a ellos. En muchos casos este refuerzo se diseña con un planteamiento pasivo, es decir, los perfiles no entran en carga hasta que no se incrementan las acciones sobre el elemento reforzado, o lo hacen sólo ligeramente y de forma cuantitativamente no controlada efectuando el retacado mediante cuñas metálicas. En el presente trabajo se estudia la alternativa del refuerzo de vigas de hormigón armado frente a momentos flectores con un planteamiento activo, introduciendo unas fuerzas (por ejemplo, mediante gatos o barras roscadas) entre el perfil y el elemento a reforzar, y retacando posteriormente el perfil a la viga en los puntos de introducción de las fuerzas, mediante cuñas metálicas, mortero, etc. La propuesta que formulamos en el presente trabajo de investigación para el control de las fuerzas introducidas consiste en la medida de las flechas que se producen en el perfil metálico al hacerlo reaccionar contra la viga. Esto permite el empleo de procedimientos sencillos para la predeformación del perfil que no dispongan de dispositivos de medida de la carga introducida, o bien controlar la veracidad de las medidas de las fuerzas que dan tales dispositivos. La gran fiabilidad que tiene el cálculo de flechas en jácenas metálicas hace que con este procedimiento se puedan conocer con gran precisión las fuerzas introducidas. Las medidas de las flechas se pueden llevar a cabo mediante los procedimientos de instrumentación habituales en pruebas de carga, con una precisión más que suficiente para conocer y controlar con fiabilidad el valor de las fuerzas que el perfil ejerce sobre la viga. Los perfiles necesarios para el refuerzo con esta técnica son netamente inferiores a los que se precisarían con el planteamiento pasivo antes indicado. En el trabajo de investigación se recoge un estudio sobre el número, posición y valor de las fuerzas de refuerzo a introducir, en función de la carga para la que se diseña el refuerzo y la capacidad resistente del elemento a reforzar, y se analizan los valores máximos que pueden tener dichas fuerzas, en función de la capacidad de la pieza frente a momentos de signo contrario a los debidos a las cargas gravitatorias. A continuación se analiza la interacción viga-perfil al incrementarse las cargas sobre la viga desde el instante de la ejecución del refuerzo, interacción que hace variar el valor de las fuerzas que el perfil ejerce sobre la viga. Esta variación permite contar con un incremento en las fuerzas de refuerzo si, con las cargas permanentes presentes al reforzar, no podemos introducirlas inicialmente con el valor necesario, o si se producen pérdidas en las propias fuerzas. Este es uno de los criterios a la hora de seleccionar las características del perfil. Por el contrario, dicha variación puede suponer que en algunos puntos a lo largo del vano se supere la capacidad a flexión frente a momentos de signo contrario a los debidos a las cargas gravitatorias, lo que también debe ser tenido en cuenta. Seguidamente se analizan diferentes aspectos que producen una variación en el valor de las fuerzas de refuerzo, como son las deformaciones diferidas del hormigón (fluencia y retracción), los gradientes de temperatura en la pieza, o la actuación de sobrecargas en los vanos adyacentes. Se concluye los efectos de estos fenómenos, que en ocasiones tienen gran influencia, pueden ser cuantificados por el proyectista, recogiéndose propuestas sencillas para su consideración en casos habituales. Posteriormente recogemos una propuesta de metodología de comprobación del refuerzo, en cuanto a cómo considerar la fisuración y evolución del módulo de deformación de la viga, la introducción de la seguridad, la influencia de las tolerancias de laminación en el perfil sobre el valor calculado de las flechas necesarias en el perfil para introducir las fuerzas iniciales proyectadas, o la situación accidental de fuego, entre otros aspectos. Por último, se exponen las conclusiones más relevantes de la investigación realizada, y se proponen futuras líneas de investigación. One technique for strengthening flexural members in general, and reinforced concrete beams and slabs in particular, entails caulking the underside of these members with steel shapes. This sort of strengthening is often designed from a passive approach; i.e., until the load is increased, the shapes are either not loaded or are only slightly loaded to some unquantified extent by caulking with steel shims. The present study explored the possibility of actively strengthening the capacity of reinforced concrete beams to resist bending moments by applying forces (with jacks or threaded bars, for instance) between the shape and the member to be strengthened. The shape is subsequently caulked under the beam at the points where the forces are applied with steel shims, mortar or similar. The proposal put forward in the present study to monitor the forces applied consists in measuring the deflection on the steel shape as it reacts against the beam. With this technique, the shape can be pre-strained using simple procedures that do not call for devices to measure the force applied, or the accurancy of the respective measurements can be verified. As deflection calculations in steel girders are extremely reliable, the forces applied with this procedure can be very precisely determined. Standard instrumental procedures for load testing can be used to measure deflection with more than sufficient precision to reliably determine and monitor the value of the forces exerted on the beam by the shape. Moreover, the shapes required to strengthen members with this technique are substantially smaller than the ones needed in the aforementioned passive approach. This study addressed the number, position and value of the strengthening forces to be applied in terms of the load for which strengthening was designed and the bearing capacity of the member to be strengthened. The maximum value of such forces was also analysed as a function of the capacity of the member to resist counter-gravity moments. An analysis was then conducted of beam-shape interaction when the load on the beam raises since the instant that strengthening is applied, interaction that alters the forces applied to the beam by the shape. This variation can provide an increment in the forces if we cannot introduce them initially with the value calculated as necessary because they were limited by the permanent loads existing when strengthening, or if losses occur in the forces themselves. This is one of the criteria for defining shape specifications. Conversely, such variation may cause the forces to exceed beam counter-gravity bending strength at some points in the span, a development that must also be taken into consideration. Other factors inducing variations in the strengthening force values were then analysed, including deferred concrete strain (creep and shrinkage), temperature gradients in the member and the live loads acting on adjacent spans. The inference drawn was that these developments, which may on occasion have a heavy impact, can be quantified by the design engineer, particularly in ordinary situations, for which simple procedures are proposed. Methodology is likewise proposed for verifying strength in terms of how to appraise beam's cracking and variations in modulus of deformation; safety concerns; the effect of shape lamination tolerance on the calculated deflection necessary for the shape to apply the design forces; and fire-induced situations, among others. Lastly, the most prominent conclusions are discussed and future lines of research are suggested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El empleo de refuerzos de FRP en vigas de hormigón armado es cada vez más frecuente por sus numerosas ventajas frente a otros métodos más tradicionales. Durante los últimos años, la técnica FRP-NSM, consistente en introducir barras de FRP sobre el recubrimiento de una viga de hormigón, se ha posicionado como uno de los mejores métodos de refuerzo y rehabilitación de estructuras de hormigón armado, tanto por su facilidad de montaje y mantenimiento, como por su rendimiento para aumentar la capacidad resistente de dichas estructuras. Si bien el refuerzo a flexión ha sido ampliamente desarrollado y estudiado hasta la fecha, no sucede lo mismo con el refuerzo a cortante, debido principalmente a su gran complejidad. Sin embargo, se debería dedicar más estudio a este tipo de refuerzo si se pretenden conservar los criterios de diseño en estructuras de hormigón armado, los cuales están basados en evitar el fallo a cortante por sus consecuencias catastróficas Esta ausencia de información y de normativa es la que justifica esta tesis doctoral. En este pro-yecto se van a desarrollar dos metodologías alternativas, que permiten estimar la capacidad resistente de vigas de hormigón armado, reforzadas a cortante mediante la técnica FRP-NSM. El primer método aplicado consiste en la implementación de una red neuronal artificial capaz de predecir adecuadamente la resistencia a cortante de vigas reforzadas con este método a partir de experimentos anteriores. Asimismo, a partir de la red se han llevado a cabo algunos estudios a fin de comprender mejor la influencia real de algunos parámetros de la viga y del refuerzo sobre la resistencia a cortante con el propósito de lograr diseños más seguros de este tipo de refuerzo. Una configuración óptima de la red requiere discriminar adecuadamente de entre los numerosos parámetros (geométricos y de material) que pueden influir en el compor-tamiento resistente de la viga, para lo cual se han llevado a cabo diversos estudios y pruebas. Mediante el segundo método, se desarrolla una ecuación de proyecto que permite, de forma sencilla, estimar la capacidad de vigas reforzadas a cortante con FRP-NSM, la cual podría ser propuesta para las principales guías de diseño. Para alcanzar este objetivo, se plantea un pro-blema de optimización multiobjetivo a partir de resultados de ensayos experimentales llevados a cabo sobre vigas de hormigón armado con y sin refuerzo de FRP. El problema multiobjetivo se resuelve mediante algoritmos genéticos, en concreto el algoritmo NSGA-II, por ser más apropiado para problemas con varias funciones objetivo que los métodos de optimización clásicos. Mediante una comparativa de las predicciones realizadas con ambos métodos y de los resulta-dos de ensayos experimentales se podrán establecer las ventajas e inconvenientes derivadas de la aplicación de cada una de las dos metodologías. Asimismo, se llevará a cabo un análisis paramétrico con ambos enfoques a fin de intentar determinar la sensibilidad de aquellos pa-rámetros más sensibles a este tipo de refuerzo. Finalmente, se realizará un análisis estadístico de la fiabilidad de las ecuaciones de diseño deri-vadas de la optimización multiobjetivo. Con dicho análisis se puede estimar la capacidad resis-tente de una viga reforzada a cortante con FRP-NSM dentro de un margen de seguridad espe-cificado a priori. ABSTRACT The use of externally bonded (EB) fibre-reinforced polymer (FRP) composites has gained acceptance during the last two decades in the construction engineering community, particularly in the rehabilitation of reinforced concrete (RC) structures. Currently, to increase the shear resistance of RC beams, FRP sheets are externally bonded (EB-FRP) and applied on the external side surface of the beams to be strengthened with different configurations. Of more recent application, the near-surface mounted FRP bar (NSM-FRP) method is another technique successfully used to increase the shear resistance of RC beams. In the NSM method, FRP rods are embedded into grooves intentionally prepared in the concrete cover of the side faces of RC beams. While flexural strengthening has been widely developed and studied so far, the same doesn´t occur to shearing strength mainly due to its great complexity. Nevertheless, if design criteria are to be preserved more research should be done to this sort of strength, which are based on avoiding shear failure and its catastrophic consequences. However, in spite of this, accurately calculating the shear capacity of FRP shear strengthened RC beams remains a complex challenge that has not yet been fully resolved due to the numerous variables involved in the procedure. The objective of this Thesis is to develop methodologies to evaluate the capacity of FRP shear strengthened RC beams by dealing with the problem from a different point of view to the numerical modeling approach by using artificial intelligence techniques. With this purpose two different approaches have been developed: one concerned with the use of artificial neural networks and the other based on the implementation of an optimization approach developed jointly with the use of artificial neural networks (ANNs) and solved with genetic algorithms (GAs). With these approaches some of the difficulties concerned regarding the numerical modeling can be overcome. As an alternative tool to conventional numerical techniques, neural networks do not provide closed form solutions for modeling problems but do, however, offer a complex and accurate solution based on a representative set of historical examples of the relationship. Furthermore, they can adapt solutions over time to include new data. On the other hand, as a second proposal, an optimization approach has also been developed to implement simple yet accurate shear design equations for this kind of strengthening. This approach is developed in a multi-objective framework by considering experimental results of RC beams with and without NSM-FRP. Furthermore, the results obtained with the previous scheme based on ANNs are also used as a filter to choose the parameters to include in the design equations. Genetic algorithms are used to solve the optimization problem since they are especially suitable for solving multi-objective problems when compared to standard optimization methods. The key features of the two proposed procedures are outlined and their performance in predicting the capacity of NSM-FRP shear strengthened RC beams is evaluated by comparison with results from experimental tests and with predictions obtained using a simplified numerical model. A sensitivity study of the predictions of both models for the input parameters is also carried out.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La utilización conjunta de los soportes de acero con los forjados de hormigón armado aúna las ventajas constructivas y arquitectónicas de ambos sistemas de ejecución. El principal inconveniente que se presenta es la complejidad de sus nudos. Las uniones estructurales viga-pilar mediante pernos tipo Nelson o Köco aparecen sólo ocasionalmente en el mundo de la edificación. Los casos en los que esto ocurre normalmente corresponden a obras de especial singularidad, a uniones secundarias o a anclajes de reducida responsabilidad estructural. La presente Tesis Doctoral tiene el objetivo principal de aportar una alternativa a las uniones convencionales entre losas o vigas de hormigón armado con pilares metálicos, utilizando para ello los pernos conectores. En este trabajo se establece un campo de aplicación concreto de las estructuras de edificación en el que la utilización de uniones mediante pernos conectores resulta óptima, dada la posibilidad de industrialización de estos nudos, su sencillez y la alta resistencia de los pernos en la transmisión del cortante. Se ha procedido al estudio teórico-analítico de la resistencia de estas uniones y a su posterior comparación experimental. Se presentan las diferencias obtenidas entre los resultados experimentales y los previstos por las formulaciones teóricas, debidas principalmente a las particularidades de las configuraciones de la unión y al efecto del rozamiento. El excelente comportamiento mecánico obtenido en los resultados experimentales induce a presagiar que la configuración de unión que se propone, junto con el método de cálculo aportado, puede llegar a sustituir a las soluciones convencionales utilizadas hasta el momento en las estructuras mixtas de edificación. Los pernos conectores aportan grandes ventajas al campo de la construcción aunque sus soldaduras, pese a la gran seguridad que las caracteriza, son difícilmente comprobables mediante ensayos no destructivos. Los ensayos destructivos no son en absoluto recomendables para las configuraciones de unión estudiadas en esta Tesis. Esto se debe principalmente al reducido número de pernos que configuran las uniones y a la gran responsabilidad que cada perno asume respecto a la seguridad global de la estructura. Los métodos convencionales de inspección presentan grandes dificultades e inconvenientes para comprobar las soldaduras de los pernos, por lo que se han investigado nuevas posibilidades de inspección y control. Esta Tesis plantea un método alternativo para la inspección de las soldaduras de los pernos conectores. El método desarrollado se basa en la acústica y consiste en el cálculo analítico de los modos propios de vibración del perno y su posterior comparación con las frecuencias naturales obtenidas a partir de una medición experimental. La investigación analítica comprende numerosas simulaciones por elementos finitos en las que se varían las condiciones de contorno para simular los defectos de soldadura. La investigación experimental consiste en la medición acústica de los pernos conectores y su posterior ensayo mediante métodos destructivos y no destructivos. Finalmente se han comparado los resultados analíticos con los obtenidos en el laboratorio y se ha obtenido una clara correlación entre las frecuencias calculadas y la calidad de las soldaduras. De este modo se puede averiguar el estado interno de una soldadura a partir de medición de su frecuencia natural de vibración. Se propone un método de inspección acústica que permite comprobar la calidad de las soldaduras de modo sencillo, económico y de fácil ejecución en obra. En conclusión, esta Tesis presenta una nueva configuración de unión mixta mediante pernos conectores y un completo método de calculo y comprobación. Finalmente se ha desarrollado un método no destructivo para la inspección de los pernos que permite garantizar la calidad de sus soldaduras en obra.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Las estructuras de hormigón son susceptibles de sufrir los efectos asociados a las acciones de fatiga cuando estas se ven sometidas a un elevado número de cargas repetidas. Muchas de estas estructuras no requieren armadura transversal para cumplir los condicionantes de dimensionamiento estático como por ejemplo las losas superiores de tableros de puentes, los muros de contención, las losas de transición de puentes, las torres eólicas o las estructuras marítimas. La mayor parte de los códigos de diseño vigentes no incluyen una comprobación específica del nivel de seguridad a cortante de estas estructuras para acciones de fatiga, y aquellas que lo hacen prefieren utilizar expresiones de tipo empírico basadas en curvas S-N que relacionan el número de ciclos resistentes con el valor de la carga aplicada. A pesar de que el empleo de curvas S-N es de gran utilidad desde un punto de vista práctico, estas curvas no permiten comprender el proceso de rotura por cortante para cargas repetidas. El objetivo principal de esta Tesis es el de estudiar el comportamiento a cortante de elementos de hormigón armado sin cercos sometidos a fatiga. Además, el análisis es ampliado al estudio del comportamiento transversal de los voladizos de las losas superiores de tableros de puentes de hormigón que de forma habitual son diseñados sin armadura de cortante. De forma habitual estos elementos se diseñan atendiendo a criterios de dimensionamiento estáticos sin tener en cuenta la resistencia a cortante cuando se ven sometidos a cargas cíclicas. A pesar de que las cargas de fatiga son inferiores a aquellas que producen el fallo estático, es importante tener en cuenta el comportamiento de estos elementos ante cargas repetidas. Los trabajos experimentales existentes en vigas de hormigón armado sin cercos evidenciaron diferencias significativas entre los modos de fallo ante cargas estáticas y cíclicas. Estos trabajos llegaron a la conclusión de que estos elementos diseñados para tener un fallo dúctil por flexión pueden llegar a desarrollar un tipo de fallo frágil por cortante cuando se ven sometidos a cargas repetidas. El proceso de rotura por cortante en elementos de hormigón armado sin cercos sometidos a fatiga es un proceso complejo que debe ser estudiado en profundidad debido al carácter frágil de este tipo de fallo. Los trabajos experimentales permitieron comprobar que el origen de este fallo tiene lugar tras la formación de una fisura de cortante a partir de una fisura de flexión formada durante los primeros ciclos en el vano de cortante. Tras la formación de esta fisura, esta se va propagando hacia la cabeza de compresión hasta que finalmente se produce el fallo como consecuencia de la destrucción de la cabeza de compresión cuando la altura alcanzada por esta es insuficiente para resistir la fuerza de compresión aplicada en esta zona. Por otra parte, la propagación de esta fisura diagonal puede desarrollarse por completo en el instante en el que esta se forma derivando en un tipo de fallo por cortante más frágil que el anterior. El proceso de fatiga es estudiado en esta Tesis mediante un modelo mecánico. Por una parte, se propone un modelo predictivo para determinar el número de ciclos acumulados hasta que se forma la fisura diagonal en función del estado tensional que se tiene en la punta de una fisura crítica de flexión formada en los primeros ciclos. Por otra parte, la resistencia a fatiga tras la formación de la fisura diagonal se analiza teniendo en cuenta el daño por fatiga acumulado en la cabeza de compresión y las variables que afectan a la propagación de esta fisura de cortante. Para la evaluación de la resistencia a fatiga tras la formación de la fisura crítica de cortante en este tipo de elementos, se plantea un modelo teórico basado en conceptos de Mecánica de la Fractura adaptados al hormigón. Este modelo puede ser aplicado a vigas de hormigón armado sin cercos de canto constante o variable siguiendo diferentes procedimientos. Una campaña experimental ha sido llevada a cabo con el objetivo de estudiar el comportamiento a cortante de vigas de hormigón armado sin cercos de canto variable sometidas a cargas estáticas y de fatiga. Se han desarrollado un total de diez ensayos estáticos y de fatiga para diferentes niveles de carga y esbelteces de cortante, teniendo lugar diferentes modos de fallo. Estos elementos fueron diseñados para reproducir, a escala real y de forma simplificada, los voladizos laterales de las losas superiores de tableros de puentes de carretera de hormigón. Los resultados experimentales demostraron que el tipo de fallo desarrollado depende de varios parámetros como por ejemplo el nivel de carga máxima, el nivel de oscilación de tensiones en la armadura longitudinal, la esbeltez de cortante o la calidad del hormigón utilizado entre otros. Para valores similares de esbeltez de cortante, los ensayos de fatiga realizados permitieron comprobar que la rotura por cortante de estos elementos está asociada a niveles de carga máxima elevados, mientras que el fallo por fatiga de la armadura longitudinal tiene mayor probabilidad de ocurrir en elementos sometidos a elevados niveles de oscilación de tensiones en esta armadura. Además, estos ensayos han sido analizados a través del modelo propuesto para tratar de comprender el comportamiento resistente de estos elementos sometidos a cargas de fatiga. Concrete structures are able to suffer fatigue when they are subjected to high number of cyclic loads. Many of these need not shear reinforcement to satisfy static design requirements, such as bridge deck slabs, retaining walls, bridge approach slabs, wind towers or maritime structures among others. Many codes of practice do not include a verification of the shear fatigue safety. Moreover, those which include it still prefer empirical S-N-based approaches that provide the number of cycles as a function of applied forces. S-N models are practical but they do not provide information to understand the shear fatigue process. The main objective of this Thesis is to study shear behaviour of reinforced concrete elements without stirrups subjected to fatigue loads. In addition, the analysis is extended in order to study the transverse behaviour of cantilever slabs of concrete bridges that traditionally are designed without shear reinforcement. These elements usually are designed on the basis of static strength and it is unusual that codes consider fatigue strength of concrete in shear. Accordingly, it is important to take into account the fatigue behaviour of structural members subjected to cyclic loads although these loads are lower than those which produce the static failure. Existing experimental works show important differences between the static and cyclic failure modes of reinforced concrete beams without stirrups. These works concluded that beams without transverse reinforcement, designed to have a ductile failure mode in flexure, can submit a brittle shear failure mode when they are subjected to repeated loads. Shear fatigue failure of reinforced concrete beams without stirrups is a rather complex process from the mechanical viewpoint. Since it leads to a brittle failure mode it should be better understood. Experimental evidence indicates that a diagonal crack first develops from the inclination of flexural cracks in the shear span. Thereafter, the diagonal crack propagates into the compression zone. Failure normally takes place by the destruction of the compression zone when its depth is too small to resist the applied force. The propagation of the diagonal crack can also be instantaneous, leading to sudden diagonal cracking fatigue failure rather than shear-compression failure. Fatigue process is studied in this Thesis on a mechanical basis. On the one hand, a predictive model is derived to obtain the number of cycles up to diagonal cracking, as a function of the stress state at the tip of a critical flexural crack. On the other hand, the residual fatigue strength after diagonal cracking is analyzed taking into account the fatigue damage accumulated by the compression zone and the variables affecting the propagation of the diagonal crack. In order to assess the residual fatigue strength after diagonal cracking of such elements, a theoretical model is proposed based on concepts from fracture mechanics adapted to concrete. This model can be successfully applied for straight or haunched reinforced concrete beams without stirrups following different procedures. In order to achieve a more advanced knowledge in this subject, an experimental campaign has been carried out with the aim of study the shear behaviour of reinforced concrete haunched beams without stirrups subjected to static and fatigue loads. A total of ten static and fatigue tests have been performed with distinct load levels and shear span-to-depth ratios, presenting different failures modes. These elements were designed to reproduce in a simplified form the cantilever slab of concrete bridges at real scale. Experimental results showed that the type of failure depends on several parameters as for example the maximum load level, the stress oscillation level on the longitudinal reinforcement, the shear span-to-depth ratio or the quality of the concrete used among others. For a similar value of the shear span-to-depth ratio, tests evidenced that shear fatigue failure is related to high maximum load levels, while steel fatigue failure is easier to occur in elements subjected to high stress oscillation level on the reinforcement bars. Besides, these tests have been analyzed through the proposed model in order to clarify the structural behaviour of such elements subjected to fatigue loads.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

En este artículo se muestra la aplicación de un método general de cálculo y dimensionamiento en el E.L.U. de estructuras de hormigón armado bidimensionales. El método presentado utiliza las hipótesis y simplificaciones usuales en el cálculo de vigas de hormigón armado, y su planteamiento desarrollado en [12] se particulariza aquí a estructuras tipo laja, con cargas contenidas en su plano medio. Para establecer los avances que permite el método propuesto se resume el estado actual de los procedimientos de dimensionamiento y comprobación tensional de lajas de hormigón armado. A continuación se indican las hipótesis básicas en las que se fundamenta la teoría y se expone la metodología desarrollada para comprobar y dimensionar una sección. Por último se demuestra la utilidad práctica del método mediante su utilización en la optimización del armado de una serie de elementos estructurales tipo membrana.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El uso de vigas planas en edificación se ha generalizado por motivos funcionales.El cálculo automatizado de esfuerzos y armado en ordenador provoca en ocasiones un exceso de confianza en el tratamiento de los detalles de casos particulares.En este articulo se trata el caso de apoyo extremo de vigas de borde y se muestran los efectos que sobre el armado tiene la asimetría de las condiciones de apoyo.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El objeto principal de este trabajo de investigación ha sido determinar si la relación de resistencias entre pilar y viga de valor 1.3, como es por ejemplo el fijado por el Eurocódigo, es suficiente para garantizar un mecanismo de columna fuerte viga débil y por lo tanto un correcto trabajo en el rango inelástico de la estructura. A este respecto y de acuerdo a la escasa literatura especializada al respecto, algunos autores tales como Paulay y Priestly (1992) o Kuntz y Browing (2003), hablan de alcanzar valores de hasta 1.8 los primeros, o valores de hasta cuatro para edificios de hasta 16 platas los segundos. En este trabajo se ha realizado un estudio paramétrico sobre una tipología estructural convencional de pórticos de hormigón armado. Para ello se ha diseñado cuatro prototipos en forma de pórticos planos con 3, 6, 9 y 12 plantas. Mediante el programa de la Universidad de Buffalo del Estado de Nueva York llamado IDARC, se ha realizado un análisis dinámico en el tiempo para los cuatro prototipos, con un catálogo de un total de 28 sismos, registrados en Europa. El programa IDARC permite la realización de un análisis en el que se tiene en cuenta factores como la no-linealidad de los materiales o las reglas histeréticas que se pretende aplicar al modelo. Los resultados del programa aportaran si con la relación de resistencia pilar-viga de 1.3, se consigue un comportamiento tipo columna fuerte viga débil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El objetivo principal de este trabajo ha sido estudiar el comportamiento de vigas de hormigón, reforzadas a cortante con tejidos de fibra de carbono pegados con resinas epoxi. Para conseguir este objetivo se han planteado objetivos parciales como el análisis de la fisuración y de los movimientos en las vigas reforzadas. La metodología empleada ha sido principalmente experimental, realizándose una serie de diez vigas de hormigón en masa o armado. Se han comparado los resultados experimentales con los teóricos, obtenidos mediante la formulación analítica existente, como la recomendada por el fib Bulletin 14. Los resultados obtenidos demuestran que las vigas reforzadas ofrecen un comportamiento significativamente superior al de las vigas sin refuerzo, tanto en el valor de las cargas últimas como en la ductilidad de las piezas. Además se puede concluir que en todos los casos estudiados la rigidez prevista hasta la fisuración de las vigas es superior a la obtenida experimentalmente. Además las vigas reforzadas a cortante con tejido de fibra de carbono poseen una ductilidad superior a la de las vigas sin reforzar

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En esta tesis, se trata del establecimiento de las bases de análisis plástico de piezas de hormigón armado en servicio y estado último procurando sentar los soportes de funcionamiento que concuerdan con la realidad y normativa vigente. El intento de establecer estas bases, con el máximo rigor para su uso, ha llevado a consecuencias lejanas cualitativas y cuantitativas sobre los modelos elásticos y elastoplásticos en uso,-momento tope ect- que, incluyendo lo complejo del problema plástico que se trata, no adoptan formulaciones adecuadas, o los plantemientos analíticos, no son más coherentes con los resultados obtenidos, en el dimensionado, que otros de base más sencilla, limitándose a estrategias de análisis de sección basadas en condicones de deformación -como serían los métodos de Cross y Matrioficiales- , estableciendose un claro divorcio entre mecanismo de cálculo y geometría. Este trabajo, intenta abrir una puerta al análisis de la estructura bajo condiciones puramente de deformación y solo supone en este campo el primer paso de un largo cemino que iría de la pieza a la estructura y de ésta al edificio posteriormente, quedando así sentados los criterios básicos para el análisis plástico global de estructuras. Todo ello a partir de la imposibilidad de avanzar en el análisis de secciones, si no es penetrando en el proceso de plastificación de las mismas y el de sus armaduras, así como el de las zonas de afección de las diferentes plastificaciones locales. La inclusión de esta concepción de análisis, en lo referente a obtener gráficos reales de respuesta interna de la pieza, es posible gracias al uso, en este caso del miniordenador 9825-HP utilizado, en donde se aplica de forma reiterada los consabidos métodos de discretización elementales con los cuales se obtienen decorosas precisiones sobre los resultados. Este estudio, que en ocasiones, alude a normas, más discribir un comportamiento que sentar doctrina. Como se ha realizado solo par forjados se añade una colección de ábacos de utilización practica de éstos. Naturalmente las bases establecidas, se hacen extensivas a cualquier pieza de directriz recta de hormigón armado, en donde geometría y materiales -hormigón y acero- pueden ser variables y están contempladas dentro de programas usados. En el terreno de las conclusiones, los forjados no deben ser asimilados a vigas, como tradicionalmente venía haciendose, ya que los métodos de relajación empledos no coinciden con la realidad. Quedando estos límites plenamente establecidos en el desarrollo del trabajo. Se considera el tema relevante en lo reeferente a un análisis de la estructura tendente a un aprovechamento más adecuado de los materiales en un supuesto futuro de escasez de materia prima, quizás no lejano, y sobretodo en la posible aproximación al modelo matemático, que si bien normativa y bibliografía aludían constantemente, nunca precisaron las bases de su comportamiento.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En los últimos años ha crecido el interés por el uso del hormigón de alta resistencia en la construcción de estructuras resistentes a explosiones y de elementos de protección frente a impactos y explosiones. En el presente trabajo se analiza la capacidad de los modelos numéricos existentes a la hora de reproducir resultados experimentales obtenidos sobre hormigones de alta resistencia sometidos a cargas explosivas y cargas estáticas. Para ello se emplea una campaña experimental desarrollada por la Agencia de Defensa de Suecia sobre vigas de este material. Los resultados obtenidos demuestran la capacidad de las herramientas numéricas para reproducir adecuadamente el comportamiento del hormigón si bien, paradójicamente, proporcionan mejores resultados en régimen dinámico que en régimen estático. Las simulaciones numéricas, junto con el análisis de los resultados experimentales, permiten obtener conclusiones acerca del diferente comportamiento de los elementos estructurales sometidos a altas velocidades de deformación frente a su comportamiento en régimen estático.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El cálculo moderno de edificios frente a acciones sísmicas contempla la posibilidad de comportamiento no lineal de los mismos, en orden a conseguir seguridad y economía en su diseño. La característica del hormigón armado de producir deformaciones plásticas sin llegar a rotura, supone un mecanismo suficientemente aceptable y seguro para absorber la energía generada durante el seísmo. En este artículo se presenta un método de cálculo no lineal de edificios, en el que se permite el desarrollo de rótulas plásticas en los nudos de unión de las vigas a los soportes. El comportamiento de los soportes se considera lineal. La acción sísmica es un conjunto de acelerogramas generados artificialmente en base a un proceso aleatorio tipo ruido de disparo filtrado, según el método de PENZIEN-RUIZ. Los resultados del cálculo se comparan con los obtenidos en un cálculo pseudo-estático aplicando la Norma POS-l.