5 resultados para TRANSMISSION-LINES

em Universidad Politécnica de Madrid


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes two methods to cancel the effect of two kinds of leakage signals which may be presented when an antenna is measured in a planar near-field range. One method tries to reduce leakage bias errors from the receiver¿s quadrature detector and it is based on estimating the bias constant added to every near-field data sample. Then, that constant is subtracted from the data, removing its undesired effect on the far-field pattern. The estimation is performed by back-propagating the field from the scan plane to the antenna under test plane (AUT) and averaging all the data located outside the AUT aperture. The second method is able to cancel the effect of the leakage from faulty transmission lines, connectors or rotary joints. The basis of this method is also a reconstruction process to determine the field distribution on the AUT plane. Once this distribution is known, a spatial filtering is applied to cancel the contribution due to those faulty elements. After that, a near-field-to-far-field transformation is applied, obtaining a new radiation pattern where the leakage effects have disappeared. To verify the effectiveness of both methods, several examples are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, the dynamic response of a hydro power plant for providing secondary regulation reserve is studied in detail. Special emphasis is given to the elastic water column effects both in the penstock and the tailrace tunnel. For this purpose, a nonlinear model based on the analogy between mass and momentum conservation equations of a water conduit and those of wave propagation in transmission lines is used. The influence of the plant configuration and design parameters on the fulfilment of the Spanish Electrical System Operator requirements is analysed

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, the dynamic response of a hydro power plant for providing secondary regulation reserve is studied in detail. S pecial emphasis is given to the elastic water column effects both in the penstock and the tailrace tunnel. For this purpose, a nonline ar model based on the analogy between mass and momentum conservation equations of a water conduit and those of wave propagation in transmission lines is used. The influence of the plant configuration and design parameters on the fulfilment of the Spanish Electrical System Operator requirem ents is analysed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hybrid Stepper Motors are widely used in open-loop position applications. They are the choice of actuation for the collimators in the Large Hadron Collider, the largest particle accelerator at CERN. In this case the positioning requirements and the highly radioactive operating environment are unique. The latter forces both the use of long cables to connect the motors to the drives which act as transmission lines and also prevents the use of standard position sensors. However, reliable and precise operation of the collimators is critical for the machine, requiring the prevention of step loss in the motors and maintenance to be foreseen in case of mechanical degradation. In order to make the above possible, an approach is proposed for the application of an Extended Kalman Filter to a sensorless stepper motor drive, when the motor is separated from its drive by long cables. When the long cables and high frequency pulse width modulated control voltage signals are used together, the electrical signals difer greatly between the motor and drive-side of the cable. Since in the considered case only drive-side data is available, it is therefore necessary to estimate the motor-side signals. Modelling the entire cable and motor system in an Extended Kalman Filter is too computationally intensive for standard embedded real-time platforms. It is, in consequence, proposed to divide the problem into an Extended Kalman Filter, based only on the motor model, and separated motor-side signal estimators, the combination of which is less demanding computationally. The efectiveness of this approach is shown in simulation. Then its validity is experimentally demonstrated via implementation in a DSP based drive. A testbench to test its performance when driving an axis of a Large Hadron Collider collimator is presented along with the results achieved. It is shown that the proposed method is capable of achieving position and load torque estimates which allow step loss to be detected and mechanical degradation to be evaluated without the need for physical sensors. These estimation algorithms often require a precise model of the motor, but the standard electrical model used for hybrid stepper motors is limited when currents, which are high enough to produce saturation of the magnetic circuit, are present. New model extensions are proposed in order to have a more precise model of the motor independently of the current level, whilst maintaining a low computational cost. It is shown that a significant improvement in the model It is achieved with these extensions, and their computational performance is compared to study the cost of model improvement versus computation cost. The applicability of the proposed model extensions is demonstrated via their use in an Extended Kalman Filter running in real-time for closed-loop current control and mechanical state estimation. An additional problem arises from the use of stepper motors. The mechanics of the collimators can wear due to the abrupt motion and torque profiles that are applied by them when used in the standard way, i.e. stepping in open-loop. Closed-loop position control, more specifically Field Oriented Control, would allow smoother profiles, more respectful to the mechanics, to be applied but requires position feedback. As mentioned already, the use of sensors in radioactive environments is very limited for reliability reasons. Sensorless control is a known option but when the speed is very low or zero, as is the case most of the time for the motors used in the LHC collimator, the loss of observability prevents its use. In order to allow the use of position sensors without reducing the long term reliability of the whole system, the possibility to switch from closed to open loop is proposed and validated, allowing the use of closed-loop control when the position sensors function correctly and open-loop when there is a sensor failure. A different approach to deal with the switched drive working with long cables is also presented. Switched mode stepper motor drives tend to have poor performance or even fail completely when the motor is fed through a long cable due to the high oscillations in the drive-side current. The design of a stepper motor output fillter which solves this problem is thus proposed. A two stage filter, one devoted to dealing with the diferential mode and the other with the common mode, is designed and validated experimentally. With this ?lter the drive performance is greatly improved, achieving a positioning repeatability even better than with the drive working without a long cable, the radiated emissions are reduced and the overvoltages at the motor terminals are eliminated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las transiciones en guía de onda son las estructuras utilizadas en microondas para transferir y adaptar la señal que viaja en un determinado sistema de transmisión (por ejemplo, un cable coaxial) a otro sistema de transmisión o a un sistema radiante (por ejemplo, una antena de bocina). Los dos sistemas de transmisión entre los que la transición adapta la señal pueden ser distintos o del mismo tipo pero con alguna de sus dimensiones diferente. Existen diferentes transiciones de guía de onda que dependiendo de su utilidad son diseñadas y construidas con diferentes secciones: circular, rectangular, elíptica o incluso combinaciones de éstas. No es necesario que la sección de la guía presente una forma geométrica conocida pero los estándares que se van a seguir hacen referencia en concreto a secciones rectangulares y circulares. En el trabajo que aquí se desarrolla se pretende optimizar por medio de simulaciones paramétricas una transición entre cable coaxial con conector tipo K y una guía de onda de sección circular que sigue el estándar presentado por Flann, Millitech y Antarfs para la banda WR34. La transición que va a ser objeto de este estudio se denomina transición tapered o transición conformada. Este tipo de transiciones se caracterizan por variar una de sus dimensiones progresivamente hasta llegar al tamaño definido en el estándar correspondiente. La manera de realizar la optimización de la transición se basará en el estudio del parámetro S11 que presente la estructura a lo largo de la banda de trabajo. Ya que se sigue el estándar WR34 la banda de trabajo que éste comprende va de 21,7 a 33 GHz. Se pretende conseguir que la respuesta del parámetro S11 se encuentre por debajo de -20 dB en la banda de WR34 como resultado del diseño para poder contar de esta manera con una buena adaptación. Finalmente se propondrá un criterio a seguir para optimizar este tipo de transiciones siguiendo el objetivo de mejor adaptación teniendo en cuenta el impacto de cada tramo sobre el rango de frecuencias en el que influye y se presentarán las características finales que presenta la transición bajo estudio. En este documento se introduce de manera breve la utilidad de los transformadores de impedancias lambda cuartos en líneas de transmisión, el estado del arte de las diferentes técnicas para su diseño, y la propuesta de diseño y caracterización objeto del presente trabajo. Posteriormente, se presenta el caso de estudio para el diseño de la transición para ser integrada a una bocina de choke. Luego, se introduce el marco teórico del trabajo presentando algunos ejemplos ilustrativos de tramos de guía de onda rectangular y guía de onda circular, introduciendo adaptadores de λ/4 en simulaciones. A continuación, se explica la implementación del modelo bajo estudio en CST (Computer Simulation Technology) Studio Suite. Finalmente se presenta la discusión de los resultados obtenidos, las conclusiones y líneas futuras de trabajo. ABSTRACT. Waveguide transitions are structures used in microwave in order to transfer and adapt the signal that travels from a certain transmission system (e.g. coaxial cable) to other transmission system or to a radiant system (e.g. horn antenna). Both transmission systems between which the transition adapts the signal can be different or from the same type, but with differences in some of their dimensions. There are different waveguide transitions that, depending on their utility, are designed and constructed in different sections: circular, rectangular, elliptic or combinations of the former. The section of the guide does not have to have a known geometric shape, although the standards to be followed in this thesis apply to rectangular and circular sections. In the work here presented, we aim to optimize by means of parametric simulations, a transition between a coaxial cable with a K-type connector and a waveguide with circular section following the standard presented by Flann, Millitech y Antarfs for the band WR34. The transition studied is called tapered transition, which is characterized by the progressive variation of its dimensions, until reaching the defined size of the corresponding standard. The way of optimizing the transition will be based in the study of the parameter S11 presented by the structure along the bandwidth. Since the standard used is the WR34, the bandwidth can be defined from 21.7 up to 33 GHz. It is aimed that the response of the S11 parameter be lower equal than -20dB in the frequency band under study according to the design in order to be well matched. Finally, a criterion to follow is proposed in order to optimize these transitions type, following the better-match objective. That will be done taking into account the impact of each section on the frequency range in which influences and the final characteristics of the studied transition will be presented. In this document, it is briefly introduced the utility of quarter-wave impedance transformers in transmission lines, the state-of-art of the different techniques for their design, and the proposal of design and characterization aimed with this work. Afterwards, the study case for the design of the transition to be integrated with a choke horn antenna will be presented. Later, the theoretical frame work is introduced, giving some illustrative examples of rectangular and circular waveguide sections, and also introducing λ/4 adaptors in the simulations. Subsequently, the implementation of the model under study in CST (Computer Simulation Technology) Studio Suite will be explained. Finally, the discussion of the results, conclusion and future lines of the work are presented.