3 resultados para THEORETICAL PREDICTION
em Universidad Politécnica de Madrid
Resumo:
Experimental research on imposed deformation is generally conducted on small scale laboratory experiments. The attractiveness of field research lies in the possibility to compare results obtained from full scale structures to theoretical prediction. Unfortunately, measurements obtained from real structures are rarely described in literature. The structural response of integral edifices depends significantly on stiffness changes and constraints. The New Airport Terminal Barajas in Madrid, Spain provides with large integral modules, partially post?tensioned concrete frames, cast monolithically over three floor levels and an overall length of approx. 80 m. The field campaign described in this article explains the instrumentation of one of these frames focusing on the influence of imposed deformations such as creep, shrinkage and temperature. The applied monitoring equipment included embedded strain gages, thermocouples, DEMEC measurements and simple displacement measurements. Data was collected throughout construction and during two years of service. A complete data range of five years is presented and analysed. The results are compared with a simple approach to predict the long?term shortening of this concrete structure. Both analytical and experimental results are discussed.
Resumo:
This paper deals with the stability limits of minimum volume and the breaking of axisymmetric liquid columns held by capillary forces between two concentric,circular solid disk of different radii. The problem has been analyzed both theoreti-cally and experimentally. A theoretical analysis concerning the breaking of liquid bridges has been performed by using a one-dimensional slice model already used in liquid bridge problems. Experiments have been carried out by using milli-metric liquid bridges, and minimum volume stability limits as well as the volumes of the drops resulting after breaking have been measured for a large number of liquid bridge configurations. Experimental results being in agreement with theoretical prediction.
Resumo:
The use of seismic hysteretic dampers for passive control is increasing exponentially in recent years for both new and existing buildings. In order to utilize hysteretic dampers within a structural system, it is of paramount importance to have simplified design procedures based upon knowledge gained from theoretical studies and validated with experimental results. Non-linear Static Procedures (NSPs) are presented as an alternative to the force-based methods more common nowadays. The application of NSPs to conventional structures has been well established; yet there is a lack of experimental information on how NSPs apply to systems with hysteretic dampers. In this research, several shaking table tests were conducted on two single bay and single story 1:2 scale structures with and without hysteretic dampers. The maximum response of the structure with dampers in terms of lateral displacement and base shear obtained from the tests was compared with the prediction provided by three well-known NSPs: (1) the improved version of the Capacity Spectrum Method (CSM) from FEMA 440; (2) the improved version of the Displacement Coefficient Method (DCM) from FEMA 440; and (3) the N2 Method implemented in Eurocode 8. In general, the improved version of the DCM and N2 methods are found to provide acceptable accuracy in prediction, but the CSM tends to underestimate the response.