10 resultados para Super Resolution

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present an analysis that shows the Maxwell Fish Eye (MFE) only has super-resolution property for some particular frequencies (for other frequencies, the MFE behaves as conventional imaging lens). These frequencies are directly connected with the Schumann resonance frequencies of spherical symmetric systems. The analysis have been done using a thin spherical waveguide (two concentric spheres with constant index between them), which is a dual form of the MFE (the electrical fields in the MFE can be mapped into the radial electrical fields in the spherical waveguide). In the spherical waveguide the fields are guided inside the space between the concentric spheres. A microwave circuit comprising three elements: the spherical waveguide, the source and the receiver (two coaxial cables) is designed in COMSOL. The super-resolution is demonstrated by calculation of Scaterring (S) parameters for different position of the coaxial cables and different frequencies of the input signal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Respiratory motion is a major source of reduced quality in positron emission tomography (PET). In order to minimize its effects, the use of respiratory synchronized acquisitions, leading to gated frames, has been suggested. Such frames, however, are of low signal-to-noise ratio (SNR) as they contain reduced statistics. Super-resolution (SR) techniques make use of the motion in a sequence of images in order to improve their quality. They aim at enhancing a low-resolution image belonging to a sequence of images representing different views of the same scene. In this work, a maximum a posteriori (MAP) super-resolution algorithm has been implemented and applied to respiratory gated PET images for motion compensation. An edge preserving Huber regularization term was used to ensure convergence. Motion fields were recovered using a B-spline based elastic registration algorithm. The performance of the SR algorithm was evaluated through the use of both simulated and clinical datasets by assessing image SNR, as well as the contrast, position and extent of the different lesions. Results were compared to summing the registered synchronized frames on both simulated and clinical datasets. The super-resolution image had higher SNR (by a factor of over 4 on average) and lesion contrast (by a factor of 2) than the single respiratory synchronized frame using the same reconstruction matrix size. In comparison to the motion corrected or the motion free images a similar SNR was obtained, while improvements of up to 20% in the recovered lesion size and contrast were measured. Finally, the recovered lesion locations on the SR images were systematically closer to the true simulated lesion positions. These observations concerning the SNR, lesion contrast and size were confirmed on two clinical datasets included in the study. In conclusion, the use of SR techniques applied to respiratory motion synchronized images lead to motion compensation combined with improved image SNR and contrast, without any increase in the overall acquisition times.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leonhardt demonstrated (2009) that the 2D Maxwell Fish Eye lens (MFE) can focus perfectly 2D Helmholtz waves of arbitrary frequency, i.e., it can transport perfectly an outward (monopole) 2D Helmholtz wave field, generated by a point source, towards a receptor called "perfect drain" (PD) located at the corresponding MFE image point. The PD has the property of absorbing the complete radiation without radiation or scattering and it has been claimed as necessary to obtain super-resolution (SR) in the MFE. However, a prototype using a "drain" different from the PD has shown λ/5 resolution for microwave frequencies (Ma et al, 2010). Recently, the SR properties of a device equivalent to the MFE, called the Spherical Geodesic Waveguide (SGW) (Miñano et al, 2012) have been analyzed. The reported results show resolution up to λ /3000, for the SGW loaded with the perfect drain, and up to λ /500 f for the SGW without perfect drain. The perfect drain was realized as a coaxial probe loaded with properly calculated impedance. The SGW provides SR only in a narrow band of frequencies close to the resonance Schumann frequencies. Here we analyze the SGW loaded with a small "perfect drain region" (González et al, 2011). This drain is designed as a region made of a material with complex permittivity. The comparative results show that there is no significant difference in the SR properties for both perfect drain designs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently it has been proved theoretically (Miñano et al, 2011) that the super-resolution up to ?/500 can be achieved using an ideal metallic Spherical Geodesic Waveguide (SGW). This SGW is a theoretical design, in which the conductive walls are considered to be lossless conductors with zero thickness. In this paper, we study some key parameters that might influence the super resolution properties reported in (Miñano et al, 2011), such as losses, metal type, the thickness of conductive walls and the deformation from perfect sphere. We implement a realistic SGW in COMSOL multiphysics and analyze its super-resolution properties. The realistic model is designed in accordance with the manufacturing requirements and technological limitations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The previous publications (Miñano et al, 2011) have shown that using a Spherical Geodesic Waveguide (SGW), it can be achieved the super-resolution up to ? /500 close to a set of discrete frequencies. These frequencies are directly connected with the well-known Schumann resonance frequencies of spherical symmetric systems. However, the Spherical Geodesic Waveguide (SGW) has been presented as an ideal system, in which the technological obstacles or manufacturing feasibility and their influence on final results were not taken into account. In order to prove the concept of superresolution experimentally, the Spherical Geodesic Waveguide is modified according to the manufacturing requirements and technological limitations. Each manufacturing process imposes some imperfections which can affect the experimental results. Here, we analyze the influence of the manufacturing limitations on the super-resolution properties of the SGW. Beside the theoretical work, herein, there has been presented the experimental results, as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Perfect drain for the Maxwell Fish Eye (MFE) is a nonmagnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity ? that depends on frequency. However, this material is only a theoretical material, so it can not be used in practical devices. Recently, the perfect drain has been claimed as necessary to achieve super-resolution [Leonhard 2009, New J. Phys. 11 093040], which has increased the interest for practical perfect drains suitable for manufacturing. Here, we analyze the superresolution properties of a device equivalent to the MFE, known as Spherical Geodesic Waveguide (SGW), loaded with the perfect drain. In the SGW the source and drain are implemented with coaxial probes. The perfect drain is realized using a circuit (made of a resistance and a capacitor) connected to the drain coaxial probes. Superresolution analysis for this device is done in Comsol Multiphysics. The results of simulations predict the superresolution up to ? /3000 and optimum power transmission from the source to the drain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leonhardt demonstrated (2009) that the 2D Maxwell Fish Eye lens (MFE) can focus perfectly 2D Helmholtz waves of arbitrary frequency, i.e., it can transport perfectly an outward (monopole) 2D Helmholtz wave field, generated by a point source, towards a "perfect point drain" located at the corresponding image point. Moreover, a prototype with λ/5 superresolution (SR) property for one microwave frequency has been manufactured and tested (Ma et al, 2010). Although this prototype has been loaded with an impedance different from the "perfect point drain", it has shown super-resolution property. However, neither software simulations nor experimental measurements for a broad band of frequencies have yet been reported. Here we present steady state simulations for two cases, using perfect drain as suggested by Leonhardt and without perfect drain as in the prototype. All the simulations have been done using a device equivalent to the MFE, called the Spherical Geodesic Waveguide (SGW). The results show the super-resolution up to λ/3000, for the system loaded with the perfect drain, and up to λ/500 for a not perfect load. In both cases super-resolution only happens for discrete number of frequencies. Out of these frequencies, the SGW does not show super-resolution in the analysis carried out.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The previous publications (Miñano et al, 2011 and Gonzalez et al, 2012) have shown that using a Spherical Geodesic Waveguide (SGW) it can be achieved the super-resolution up to λ/3000, which is far below the classic Abbe diffraction limit, close to a set of discrete microwave frequencies. The SGW was designed and simulated in COMSOL as a thin geodesic waveguide bounded by an ideal and lossless metal. Herein we present the experimental results for a manufactured SGW, slightly modified due to fabrication requirements, showing the super-resolution up to λ/105.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Super-resolution (SR) systems surpassing the Abbe diffraction limit have been theoretically and experimentally demonstrated using a number of different approaches and technologies: using materials with a negative refractive index, utilizing optical super-oscillation, using a resonant metalens, etc. However, recently it has been proved theoretically that in the Maxwell fish-eye lens (MFE), a device made of positive refractive index materials, the same phenomenon takes place. Moreover, using a simpler device equivalent to the MFE called the spherical geodesic waveguide (SGW), an SR of up to λ/3000 was simulated in COMSOL. Until now, only one piece of experimental evidence of SR with positive refraction has been reported (up to λ/5) for an MFE prototype working at microwave frequencies. Here, experimental results are presented for an SGW prototype showing an SR of up to λ/105. The SGW prototype consists of two concentric metallic spheres with an air space in between and two coaxial ports acting as an emitter and a receiver. The prototype has been analyzed in the range 1 GHz to 1.3 GHz.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The capability of a device called the Spherical Geodesic Waveguide (SGW) to produce images with details below the classic Abbe diffraction limit (super-resolution) is analyzed here. The SGW is an optical system equivalent (by means of Transformation Optics) to the Maxwell Fish Eye (MFE) refractive index distribution. Recently, it has been claimed that the necessary condition to get super-resolution in the MFE and the SGW is the use of a Perfect Point Drain (PPD). The PPD is a punctual receptor placed in the focal point that absorbs the incident wave, without reflection or scattering. A microwave circuit comprising three elements, the SGW, the source and the drain (two coaxial lines loaded with specific impedances) is designed and simulated in COMSOL. The super-resolution properties have been analyzed for different position of the source and drain and for two different load impedances: the PPD and the characteristic line impedance. The results show that in both cases super-resolution occurs only for discrete number of frequencies. Out of these frequencies, the SGW does not show SR in the analysis carried out.