10 resultados para Subcooled boiling
em Universidad Politécnica de Madrid
Resumo:
The Bienaventurada mine operates a polymetallic Ag-Pb-Zn (Cu, Au) vein system of the low sulphidation epithermal type. Fluid inclusions, FI, are abundant in quartz, sphalerite and adularia. FI petrography demonstrates typical primary growth zoning which occurs frequently in crystalline quartz, and defines the most common primary FI. These are usually very small, but several types of primary, P, and secondary, S, FI Assemblages (FIAs) comprising FI of measurable size (3 to > 100 μm) can also be identified through careful petrographic work. The fluids are aqueous and undersaturated, and no evidence of CO2 was found; the degree of fill is usually high (~70-80 %) in the L-rich inclusions, but extremely low in V-rich inclusions. The measured microthermometric values are very consistent in the FIAs selected; they are for the most part roughly similar in the P and S assemblages: the median is typically ~258ºC for total homogenization temperatures, Th, and -1.5 ºC for ice melting temperatures, Tm (corresponding to 2.57 wt% NaCl eq). The widespread occurrence of L-rich and V-rich FI in the same FIA and the consistent Th values point to an extensive boiling system along the vein. In these conditions, Th equals T of trapping, and the ores are assumed to have been precipitated from an aqueous low salinity boiling fluid, of likely meteoric origin, at some 250-280º C, under ~500 m hydrostatic head.
Resumo:
The need to refine models for best-estimate calculations, based on good-quality experimental data, has been expressed in many recent meetings in the field of nuclear applications. The modeling needs arising in this respect should not be limited to the currently available macroscopic methods but should be extended to next-generation analysis techniques that focus on more microscopic processes. One of the most valuable databases identified for the thermalhydraulics modeling was developed by the Nuclear Power Engineering Corporation (NUPEC), Japan. From 1987 to 1995, NUPEC performed steady-state and transient critical power and departure from nucleate boiling (DNB) test series based on the equivalent full-size mock-ups. Considering the reliability not only of the measured data, but also other relevant parameters such as the system pressure, inlet sub-cooling and rod surface temperature, these test series supplied the first substantial database for the development of truly mechanistic and consistent models for boiling transition and critical heat flux. Over the last few years the Pennsylvania State University (PSU) under the sponsorship of the U.S. Nuclear Regulatory Commission (NRC) has prepared, organized, conducted and summarized the OECD/NRC Full-size Fine-mesh Bundle Tests (BFBT) Benchmark. The international benchmark activities have been conducted in cooperation with the Nuclear Energy Agency/Organization for Economic Co-operation and Development (NEA/OECD) and Japan Nuclear Energy Safety (JNES) organization, Japan. Consequently, the JNES has made available the Boiling Water Reactor (BWR) NUPEC database for the purposes of the benchmark. Based on the success of the OECD/NRC BFBT benchmark the JNES has decided to release also the data based on the NUPEC Pressurized Water Reactor (PWR) subchannel and bundle tests for another follow-up international benchmark entitled OECD/NRC PWR Subchannel and Bundle Tests (PSBT) benchmark. This paper presents an application of the joint Penn State University/Technical University of Madrid (UPM) version of the well-known subchannel code COBRA-TF, namely CTF, to the critical power and departure from nucleate boiling (DNB) exercises of the OECD/NRC BFBT and PSBT benchmarks
Resumo:
Over the last few years, the Pennsylvania State University (PSU) under the sponsorship of the US Nuclear Regulatory Commission (NRC) has prepared, organized, conducted, and summarized two international benchmarks based on the NUPEC data—the OECD/NRC Full-Size Fine-Mesh Bundle Test (BFBT) Benchmark and the OECD/NRC PWR Sub-Channel and Bundle Test (PSBT) Benchmark. The benchmarks’ activities have been conducted in cooperation with the Nuclear Energy Agency/Organization for Economic Co-operation and Development (NEA/OECD) and the Japan Nuclear Energy Safety (JNES) Organization. This paper presents an application of the joint Penn State University/Technical University of Madrid (UPM) version of the well-known sub-channel code COBRA-TF (Coolant Boiling in Rod Array-Two Fluid), namely, CTF, to the steady state critical power and departure from nucleate boiling (DNB) exercises of the OECD/NRC BFBT and PSBT benchmarks. The goal is two-fold: firstly, to assess these models and to examine their strengths and weaknesses; and secondly, to identify the areas for improvement.
Resumo:
From the 60s to the 90s, a great number of events related to the Emergency Core Cooling Systems Strainers have been happened in all kind of reactors all over the world. Thus, the Nuclear Regulatory Commission of the USA emitted some Bulletins to address the concerns about the adequacy of Emergency Core Cooling Systems (ECCS) strainer performance at boiling water reactors (BWR). In Spain the regulatory body (Consejo de Seguridad Nuclear, CSN) adopted the USA regulation and Cofrentes NPP installed new strainers with a considerable bigger size than the old strainers. The nuclear industry conducted significant and extensive research, guidance development, testing, reviews, and hardware and procedure changes during the 90s to resolve the issues related to debris blockage of BWR strainers. In 2001 the NRC and CSN closed the Bulletins. Thereafter, the strainers issues were moved to the PWR reactors. In 2004 the NRC issued a Generic Letter (GL). It requested the resolution of several effects which were not noted in the past. The GL regarded to be resolved by the PWR reactors but the NRC in USA and the CSN in Spain have requested that the BWR reactors investigate differences between the methodologies used by the BWRs and PWRs. The developments and improvements done for Cofrentes NPP are detailed. Studies for this plant show that the head loss due to the considered debris is at most half of the limited head loss for the ECCS strainer and the NPSH (Net Positive Suction Head) required for the ECCS pumps is at least three times lower than the NPSH available.
Resumo:
The ability to reproduce reduced gravity conditions for long periods is one of the reasons why the orbiting laboratory is so attractive. In this paper several fluid dynamics problem areas are reviewed in which zero-gravity conditions are of great importance. Although emphasis is placed on space processing, there are some older problems also in which gravity masks the phenomcna, impeding a reasonably simple approach to the solution. Three problems are considered: Thermal convection under reduced gravity. The dumping effect ofsurface gravity waves at the outset of convection induced by surface tractions is discussed in particular. The existence of convection is of concern for some satellite thermal control techniques presently used, and for most of the proposed manufacturing processes. Whereas convection should be normally avoided, problems related to the containerless stirring ofa melt constitute an exception. Secondly, gravity and chemical reactions. Although chemical reactions are independent of gravity because of the small mass of the molecules and atoms involved, in many cases the reaction rate dcpends on the arrival of the species to the reaction zone. When the arrival process is buoyancy-controlled, the net specd of the reaction will be affected by the gravity. Thirdly, two-phase flows under reduced gravity provkle interesting problems from boiling heat transfer to degasslng of melts. This part of the paper deals only with the measurement of sound veiocity in a liquid containing bubbles. It is suggested that such measurements should be mude under reduced gravity to provide reliable residís.
Resumo:
Babassu and camelina oils have been transesterified with methanol by the classical homogeneous basic catalysis method with good yields. The babassu fatty acid methyl ester (FAME) has been subjected to fractional distillation at vacuum, and the low boiling point fraction has been blended with two types of fossil kerosene, a straight-run atmospheric distillation cut (hydrotreated) and a commercial Jet-A1. The camelina FAME has been blended with the fossil kerosene without previous distillation. The blends of babassu biokerosene and Jet-A1 have met some of the specifications selected for study of the ASTM D1655 standard: smoke point, density, flash point, cloud point, kinematic viscosity, oxidative stability and lower heating value. On the other hand, the blends of babassu biokerosene and atmospheric distillation cut only have met the density parameter and the oxidative stability. The blends of camelina FAME and atmospheric distillation cut have met the following specifications: density, kinematic viscosity at −20 °C, and lower heating value. With these preliminary results, it can be concluded that it would be feasible to blend babassu and camelina biokerosenes prepared in this way with commercial Jet-A1 up to 10 vol % of the former, if these blends prove to accomplish all the ASTM D1655-09 standards.
Resumo:
Se investiga la compleja mineralogía del Yacimiento de Pallancata (6º productor de plata del mundo) y se establecen las condiciones de formación (P.T) basadas en la petrología de las menas comparada con los datos de mineralogía experimental y en la petrografía y microtermometría de inclusiones fluídas en la ganga silicatada, resultando un depósito típicamente caracterizado como epitermal de sulfuración intermedia.ABSTRACT:Pallancata is a world-class intermediate-sulfidation epithermal deposit, hosted by upper Miocene volcanics of the south-central Peruvian Andes in a sinuous N70ºW, ∼75º SW strike-slip structure, with wide (up to 35 m) pull-apart dilation zones related to bends of the vein strike. The structural evolution of the vein from earlier brecciation to later open space infill resembles the Shila Paula district (Chauvet et al. 2006). Fluid inclusion petrography and microthermometry show that ore deposition is related to protracted boiling of very diluted, mainly meteoric fluids, starting at 250–260 ºC, under ∼300 m hydrostatic head. The mineralogical-petrological study reveals a complex sequence of mineralization (eight stages) and mineral reactions consistent with Ag2S enrichment or Sb2S3 depletion, or both, during cooling over the temperature range 250–200 ºC: pyrite, sphalerite, galena, miargyrite, pyrargyrite-proustite, chalcopyrite, polybasite-pearceite, argentite (now acanthite), and Au–Ag alloy (“electrum”). This Ag2S enrichment and Sb2S3depletion during cooling may be explained by decay of a Ag-rich galena precursor at deeper levels (Pb2S2–AgSbS2 solid solution), which rapidly becomes unstable with decreasing temperature, producing residual (stoichiometric) PbS and more mobile Ag and Sb sulfide phases, which migrated upward and laterally away from the thermal core of the system. The core is still undisclosed by mining works, but the available geochemical evidence (logAg/log Pb ratios decreasing at depth) is consistent with this interpretation, implying a deeper potential resource. Data from sulfide geothermometry, based on mineral equilibria, document the thermal evolution of the system below 200 ºC (stephanite, uytenbogaardtite, jalpaite, stromeyerite, mckinstryite, among others). The end of the most productive stages (3, 4, and 5) is marked by the precipitation of stephanite at temperatures below 197 ± 5 ºC, but precipitation of residual silver continues through the waning stages of the hydrothermal system down to <93.3 ºC (stromeyerite) or in a supergene redistribution (stage 8, acanthite II).
Resumo:
Three different oils: babassu, coconut and palm kernel have been transesterified with methanol. The fatty acid methyl esters (FAME) have been subjected to vacuum fractional distillation, and the low boiling point fractions have been blended with fossil kerosene at three different proportions: 5, 10 and 20% vol.
Resumo:
Historically, the prediction of safety margins has been based on system level thermal-hydraulic calculations employing suitable empirical formulations for assembly specific geometries and fuel-element grid spacers. These works have assessed response, margins, and consequences for the system based on one-dimensional two-fluid or drift-flux type thermalhydraulics formulations with fuel-vendor specific hydraulic losses and heat transfer characteristics for various fuel assemblies, including the so-called hot channel. Analysis of the hot channel gives important information on flow rates, fuel element centerline temperature, fuel sheath temperature, and margin to the departure from nucleate boiling. Given the reliance of the above approaches on empirical formulations obtained from complex and often difficult experiments, there is significant interest in obtaining reliable and accurate results from computation tools which employ more fundamental empirical relationships which can be obtained from subsets of the domain or from other scaled experiments.
Resumo:
En la presente Tesis se realizó un análisis numérico, usando el código comercial Ansys-Fluent, de la refrigeración de una bola de combustible de un reactor de lecho de bolas (PBR, por sus siglas en inglés), ante un escenario de emergencia en el cual el núcleo sea desensamblado y las bolas se dejen caer en una piscina de agua, donde el mecanismo de transferencia de calor inicialmente sería la ebullición en película, implicando la convección y la radiación al fluido. Previamente se realizaron pruebas de validación, comparando los resultados numéricos con datos experimentales disponibles en la literatura para tres geometrías diferentes, lo cual permitió seleccionar los esquemas y modelos numéricos con mejor precisión y menor costo computacional. Una vez identificada la metodología numérica, todas las pruebas de validación fueron ampliamente satisfactorias, encontrándose muy buena concordancia en el flujo de calor promedio con los datos experimentales. Durante estas pruebas de validación se lograron caracterizar numéricamente algunos parámetros importantes en la ebullición en película con los cuales existen ciertos niveles de incertidumbre, como son el factor de acoplamiento entre convección y radiación, y el factor de corrección del calor latente de vaporización. El análisis térmico de la refrigeración de la bola del reactor por ebullición en película mostró que la misma se enfría, a pesar del calor de decaimiento, con una temperatura superficial de la bola que desciende de forma oscilatoria, debido al comportamiento inestable de la película de vapor. Sin embargo, la temperatura de esta superficie tiene una buena uniformidad, notándose que las áreas mejor y peor refrigeradas están localizadas en la parte superior de la bola. Se observó la formación de múltiples domos de vapor en diferentes posiciones circunferenciales, lo cual causa que el área más caliente de la superficie se localice donde se forman los domos más grandes. La separación entre los domos de vapor fue consistente con la teoría hidrodinámica, con la adición de que la separación entre domos se reduce a medida que evolucionan y crecen, debido a la curvatura de la superficie. ABSTRACT A numerical cooling analysis of a PBR fuel pebble, after an emergency scenario in which the nucleus disassembly is made and the pebbles are dropped into a water pool, transmitting heat by film boiling, involving convection and radiation to the fluid, is carried out in this Thesis. First, were performed validation tests comparing the numerical results with experimental works available for three different geometries, which allowed the selection of numerical models and schemes with better precision and lower computational cost. Once identified the numerical methodology, all validation tests were widely satisfactory, finding very good agreement with experimental works in average heat flux. During these validation tests were achieved numerically characterize some important parameters in film boiling with which there are certain levels of uncertainty, such as the coupling factor between convection and radiation, and the correction factor of the latent heat of vaporization. The thermal analysis of pebble cooling by film boiling shows that despite its decay heat, cooling occurs, with pebble surface temperature descending from an oscillatory manner, due to the instability of the vapor film. However, the temperature of this surface has a good uniformity, noting that the best and worst refrigerated area is located at the top of the pebble. The formation of multiple vapor domes at different circumferential positions is observed, which cause that the hottest area of the surface was located where biggest vapor domes were formed. The separation between vapor domes was consistent with the hydrodynamic theory, with the addition that the separation is reduced as the vapor dome evolves and grows, due to the surface curvature.