3 resultados para Stopper
em Universidad Politécnica de Madrid
Resumo:
The analysis of the viability of Hydrogen production without CO2 emissions is one of the most challenging activities that have been initiated for a sustainable energy supply. As one of the tracks to fulfil such objective, direct methane cracking has been analysed experimentally to assess the scientific viability and reaction characterization in a broad temperature range, from 875 to 1700 ?C. The effect of temperature, sweeping/carrier gas fraction proposed in some concepts, methane flow rate, residence time, and tube material and porosity has been analysed. The aggregation of carbon black particles to the reaction tube is the main technological show-stopper that has been identified.
Resumo:
Fourier transform infrared (FTIR) spectroscopy was applied to determine the type of surface treatment and dose used on cork stoppers and to predict the friction between stopper and bottleneck. Agglomerated cork stoppers were finished with two different doses and using two surface treatments: P (paraffin and silicone), 15 and 25 mg/stopper, and S (only silicone), 10 and 15 mg/stopper. FTIR spectra were recorded at five points for each stopper by attenuated total reflectance (ATR). Absorbances at 1,010, 2,916, and 2,963 cm -1 were obtained in each spectrum. Discriminant analysis techniques allowed the treatment, and dose applied to each stopper to be identified from the absorbance values. 91.2% success rates were obtained from individual values and 96.0% from the mean values of each stopper. Spectrometric data also allowed treatment homogeneity to be determined on the stopper surface, and a multiple regression model was used to predict the friction index (If = Fe/Fc) (R 2 = 0.93)
Resumo:
An objective control method for grading cork stoppers is presented using a cork stopper quality index based on porosity, density and elasticity, these being the properties which have the greatest influence on the closure capacity of the stopper. The elasticity of the cork stopper is measured through the relaxation ratio, which is defined by the relationship between the relaxation force exerted by the cork in the bottleneck and the compressive force exerted by a caliper to fit the stopper in the bottle. The relaxation ratio, defined in this way, represents the part of the compression force which is applied to the stopper on insertion and which is recovered in the form of the relaxation force to achieve closure. The calculation of the relaxation ratio involves the measurement of the relaxation force of the fitted stopper. This force has been measured rigorously and precisely using a device developed in the Cork Laboratory at the INIA-CIFOR and which is presented for the first time in this paper.