3 resultados para Starting Process

em Universidad Politécnica de Madrid


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previously degradation studies carried out, over a number of different mortars by the research team, have shown that observed degradation does not exclusively depend on the solution equilibrium pH, nor the aggressive anions relative solubility. In our tests no reason was found that could allow us to explain, why same solubility anions with a lower pH are less aggressive than others. The aim of this paper is to study cement pastes behavior in aggressive environments. As observed in previous research, this cement pastes behaviors are not easily explained only taking into account only usual parameters, pH, solubility etc. Consequently the paper is about studying if solution physicochemical characteristics are more important in certain environments than specific pH values. The paper tries to obtain a degradation model, which starting from solution physicochemical parameters allows us to interpret the different behaviors shown by different composition cements. To that end, the rates of degradation of the solid phases were computed for each considered environment. Three cement have been studied: CEM I 42.5R/SR, CEM II/A-V 42.5R and CEM IV/B-(P-V) 32.5 N. The pastes have been exposed to five environments: sodium acetate/acetic acid 0.35 M, sodium sulfate solution 0.17 M, a solution representing natural water, saturated calcium hydroxide solution and laboratory environment. The attack mechanism was meant to be unidirectional, in order to achieve so; all sides of cylinders were sealed except from the attacked surface. The cylinders were taking out of the exposition environments after 2, 4, 7, 14, 30, 58 and 90 days. Both aggressive solution variations in solid phases and in different depths have been characterized. To each age and depth the calcium, magnesium and iron contents have been analyzed. Hydrated phases evolution studied, using thermal analysis, and crystalline compound changes, using X ray diffraction have been also analyzed. Sodium sulphate and water solutions stabilize an outer pH near to 8 in short time, however the stability of the most pH dependent phases is not the same. Although having similar pH and existing the possibility of forming a plaster layer near to the calcium leaching surface, this stability is greater than other sulphate solutions. Stability variations of solids formed by inverse diffusion, determine the rate of degradation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract?Background: There is no globally accepted open source software development process to define how open source software is developed in practice. A process description is important for coordinating all the software development activities involving both people and technology. Aim: The research question that this study sets out to answer is: What activities do open source software process models contain? The activity groups on which it focuses are Concept Exploration, Software Requirements, Design, Maintenance and Evaluation. Method: We conduct a systematic mapping study (SMS). A SMS is a form of systematic literature review that aims to identify and classify available research papers concerning a particular issue. Results: We located a total of 29 primary studies, which we categorized by the open source software project that they examine and by activity types (Concept Exploration, Software Requirements, Design, Maintenance and Evaluation). The activities present in most of the open source software development processes were Execute Tests and Conduct Reviews, which belong to the Evaluation activities group. Maintenance is the only group that has primary studies addressing all the activities that it contains. Conclusions: The primary studies located by the SMS are the starting point for analyzing the open source software development process and proposing a process model for this community. The papers in our paper pool that describe a specific open source software project provide more regarding our research question than the papers that talk about open source software development without referring to a specific open source software project.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared thermography (IRT) is a safe and non-invasive tool used for examining physiological functions based on skin temperature (Tsk) control. Thermograms from 25 anterior cruciate ligament (ACL) surgically operated patients (2 female, 23 male) were taken with a FLIR infrared camera according to the protocol established by the International Academy of Clinical Thermology (IACT). This work consists of 4 studies. Studies 1 and 3 were related to establish the probable thermal difference among different moments of an ACL rupture after surgery: before starting the rehabilitation (P0), at the end of rehabilitation (P1) and 18 months from the end of rehabilitation (P2). For this purpose, on the other hand, studies 2 and 4 were related to establish the skin thermal difference (Tsk) between the injured and the non-injured leg in P0, P1 and P2. Results of the first study showed significant temperature increases in the posterior thigh area between P0 and P1 probably due to a compensatory mechanism. According to this, we can conclude that temperature of the posterior area of the injured and noninjured leg has increased from the first to the last day of the rehabilitation process. In the second study we found significant temperature differences between the injured and non-injured leg in both stages of rehabilitation (p<.01). On the one hand, the temperature of the injured leg is higher in the anterior view and the temperature of the non-injured leg is higher in the posterior view. By the time the patients had recovered from the reconstruction, thermal imbalances should have not been shown between symmetrical parts, but differences seemed to be still latent.. Study 3 shows that temperatures seem to be higher after a year and a half (P2) than in P1. Study 4 shows how thermal values 18 months later seemed to be normalized between both legs. No significant differences were found between the injured leg and the noninjured leg after one year and a half of the rehabilitation process. Considering results from Study 3 and 4 we can conclude that patients seemed to have recovered from a thermal point of view. The temperature in P2 was higher but symmetrical. RESUMEN La termografía infrarroja (IRT) es una herramienta segura y no invasiva utilizada para examinar funciones fisiológicas que se basan en el control de temperatura de la piel (Tsk). Termogramas de 25 pacientes intervenidos quirúrgicamente del ligamento cruzado anterior (LCA) (2 mujeres, 23 hombres) fueron tomadas con una cámara de infrarrojos FLIR de acuerdo con el protocolo establecido por la Academia Internacional de Termología Clínica (IACT). Este trabajo consiste en 4 estudios. Los estudios 1 y 3 describen la diferencia térmica entre los diferentes momentos tras la operación del ligamento cruzado anterior: antes de comenzar la rehabilitación (P0), al final de la rehabilitación (P1) y 18 meses tras finalizar la rehabilitación (P2). Por otra parte, los estudios 2 y 4 describen la diferencia de temperatura de la piel (Tsk) entre la pierna lesionada y la pierna no lesionada en P0, P1 y P2. Los resultados del primer estudio mostraron aumentos significativos de temperatura en la zona posterior de los muslos entre P0 y P1, probablemente debido a un mecanismo de compensación. De acuerdo con esto, se puede concluir que la temperatura de la zona posterior de la pierna lesionada y no lesionada se ha incrementado desde el primero hasta el último día del proceso de rehabilitación. En el segundo estudio se encontraron diferencias significativas de temperatura entre la pierna lesionada y no lesionada en ambas etapas de la rehabilitación (p<.01). Por un lado, la temperatura de la pierna lesionada es mayor en la vista anterior. Por otro lado, la temperatura de la pierna no lesionada es mayor en la vista posterior. Una vez que los pacientes se han recuperado de todo el proceso, no deberían existir desequilibrios térmicos entre partes simétricas del cuerpo, pero las diferencias todavía estaban latentes. El tercer estudio muestra que la temperatura es más alta en P2 que en P1. El cuarto estudio muestra cómo los valores térmicos entre ambas piernas en P2 se han normalizado entre ambas piernas. No se encontraron diferencias significativas entre la pierna lesionada y la pierna no lesionada después de 18 meses tras el proceso de rehabilitación. Considerando los resultados del studio 3 y 4, podemos concluir que se ha llegado a la recuperación total desde un punto de vista térmico. La temperatura es más elevada en P2 pero simétrica.