63 resultados para Solar cooling system

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a practical implementation of a solar thermophotovoltaic (TPV) system. The system presented in this paper comprises a sunlight concentrator system, a cylindrical cup-shaped absorber/emitter (made of tungsten coated with HfO2), and an hexagonal-shaped water-cooled TPV generator comprising 24 germanium TPV cells, which is surrounding the cylindrical absorber/emitter. This paper focuses on the development of shingled TPV cell arrays, the characterization of the sunlight concentrator system, the estimation of the temperature achieved by the cylindrical emitters operated under concentrated sunlight, and the evaluation of the full system performance under real outdoor irradiance conditions. From the system characterization, we have measured short-circuit current densities up to 0.95 A/cm2, electric power densities of 67 mW/cm2, and a global conversion efficiency of about 0.8%. To our knowledge, this is the first overall solar-to-electricity efficiency reported for a complete solar thermophotovoltaic system. The very low efficiency is mainly due to the overheating of the cells (up to 120 °C) and to the high optical concentrator losses, which prevent the achievement of the optimum emitter temperature. The loss analysis shows that by improving both aspects, efficiencies above 5% could be achievable in the very short term and efficiencies above 10% could be achieved with further improvements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From the 60s to the 90s, a great number of events related to the Emergency Core Cooling Systems Strainers have been happened in all kind of reactors all over the world. Thus, the Nuclear Regulatory Commission of the USA emitted some Bulletins to address the concerns about the adequacy of Emergency Core Cooling Systems (ECCS) strainer performance at boiling water reactors (BWR). In Spain the regulatory body (Consejo de Seguridad Nuclear, CSN) adopted the USA regulation and Cofrentes NPP installed new strainers with a considerable bigger size than the old strainers. The nuclear industry conducted significant and extensive research, guidance development, testing, reviews, and hardware and procedure changes during the 90s to resolve the issues related to debris blockage of BWR strainers. In 2001 the NRC and CSN closed the Bulletins. Thereafter, the strainers issues were moved to the PWR reactors. In 2004 the NRC issued a Generic Letter (GL). It requested the resolution of several effects which were not noted in the past. The GL regarded to be resolved by the PWR reactors but the NRC in USA and the CSN in Spain have requested that the BWR reactors investigate differences between the methodologies used by the BWRs and PWRs. The developments and improvements done for Cofrentes NPP are detailed. Studies for this plant show that the head loss due to the considered debris is at most half of the limited head loss for the ECCS strainer and the NPSH (Net Positive Suction Head) required for the ECCS pumps is at least three times lower than the NPSH available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pumped storage hydro plants (PSHP) can provide adequate energy storage and frequency regulation capacities in isolated power systems having significant renewable energy resources. Due to its high wind and solar potential, several plans have been developed for La Palma Island in the Canary archipelago, aimed at increasing the penetration of these energy sources. In this paper, the performance of the frequency control of La Palma power system is assessed, when the demand is supplied by the available wind and solar generation with the support of a PSHP which has been predesigned for this purpose. The frequency regulation is provided exclusively by the PSHP. Due to topographic and environmental constraints, this plant has a long tail-race tunnel without a surge tank. In this configuration, the effects of pressure waves cannot be neglected and, therefore, usual recommendations for PID governor tuning provide poor performance. A PI governor tuning criterion is proposed for the hydro plant and compared with other criteria according to several performance indices. Several scenarios considering solar and wind energy penetration have been simulated to check the plant response using the proposed criterion. This tuning of the PI governor maintains La Palma system frequency within grid code requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solar thermal power plants are usually installed in locations with high yearly average solar radiation, often deserts. In such conditions, cooling water required for thermodynamic cycles is rarely available. Moreover, when solar radiation is high, ambient temperature is very high as well; this leads to excessive condensation temperature, especially when air-condensers are used, and decreases the plant efficiency. However, temperature variation in deserts is often very high, which drives to relatively low temperatures during the night. This fact can be exploited with the use of a closed cooling system, so that the coolant (water) is chilled during the night and store. Chilled water is then used during peak temperature hours to cool the condenser (dry cooling), thus enhancing power output and efficiency. The present work analyzes the performance improvement achieved by night thermal cool storage, compared to its equivalent air cooled power plant. Dry cooling is proved to be energy-effective for moderately high day–night temperature differences (20 °C), often found in desert locations. The storage volume requirement for different power plant efficiencies has also been studied, resulting on an asymptotic tendency.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The real increase in energy prices and the intention of reducing pollutant emissions in developed countries makes interesting to use solar energy in all the processes where its application is possible. As it is demonstrated in countries sited at latitudes with optimal conditions of solar radiation and temperature, it is possible to use solar energy as heat source for small-scale hatchery [1,2], but beyond, making a design for proper installation; it is possible to use solar energy as main or support energy source in medium and large size incubators . Monitoring of a normal actual process using temperature and relative humidity sensors is necessary to know the actual operating conditions that the solar heating system must be designed and sized for. Moreover, the identification and analysis of temperature and enthalpy gradients inside the incubator is of major importance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Experiences in decentralized rural electrification programmes using solar home systems have suffered difficulties during the operation and maintenance phase, due in many cases, to the underestimation of the maintenance cost, because of the decentralized character of the activity, and also because the reliability of the solar home system components is frequently unknown. This paper reports on the reliability study and cost characterization achieved in a large photovoltaic rural electrification programme carried out in Morocco. The paper aims to determinate the reliability features of the solar systems, focusing in the in-field testing for batteries and photovoltaic modules. The degradation rates for batteries and PV modules have been extracted from the in-field experiments. On the other hand, the main costs related to the operation and maintenance activity have been identified with the aim of establishing the main factors that lead to the failure of the quality sustainability in many rural electrification programmes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

En el campo de la fusión nuclear y desarrollándose en paralelo a ITER (International Thermonuclear Experimental Reactor), el proyecto IFMIF (International Fusion Material Irradiation Facility) se enmarca dentro de las actividades complementarias encaminadas a solucionar las barreras tecnológicas que aún plantea la fusión. En concreto IFMIF es una instalación de irradiación cuya misión es caracterizar materiales resistentes a condiciones extremas como las esperadas en los futuros reactores de fusión como DEMO (DEMOnstration power plant). Consiste de dos aceleradores de deuterones que proporcionan un haz de 125 mA y 40 MeV cada uno, que al colisionar con un blanco de litio producen un flujo neutrónico intenso (1017 neutrones/s) con un espectro similar al de los neutrones de fusión [1], [2]. Dicho flujo neutrónico es empleado para irradiar los diferentes materiales candidatos a ser empleados en reactores de fusión, y las muestras son posteriormente examinadas en la llamada instalación de post-irradiación. Como primer paso en tan ambicioso proyecto, una fase de validación y diseño llamada IFMIFEVEDA (Engineering Validation and Engineering Design Activities) se encuentra actualmente en desarrollo. Una de las actividades contempladas en esta fase es la construcción y operación de una acelarador prototipo llamado LIPAc (Linear IFMIF Prototype Accelerator). Se trata de un acelerador de deuterones de alta intensidad idéntico a la parte de baja energía de los aceleradores de IFMIF. Los componentes del LIPAc, que será instalado en Japón, son suministrados por diferentes países europeos. El acelerador proporcionará un haz continuo de deuterones de 9 MeV con una potencia de 1.125 MW que tras ser caracterizado con diversos instrumentos deberá pararse de forma segura. Para ello se requiere un sistema denominado bloque de parada (Beam Dump en inglés) que absorba la energía del haz y la transfiera a un sumidero de calor. España tiene el compromiso de suministrar este componente y CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) es responsable de dicha tarea. La pieza central del bloque de parada, donde se para el haz de iones, es un cono de cobre con un ángulo de 3.5o, 2.5 m de longitud y 5 mm de espesor. Dicha pieza está refrigerada por agua que fluye en su superficie externa por el canal que se forma entre el cono de cobre y otra pieza concéntrica con éste. Este es el marco en que se desarrolla la presente tesis, cuyo objeto es el diseño del sistema de refrigeración del bloque de parada del LIPAc. El diseño se ha realizado utilizando un modelo simplificado unidimensional. Se han obtenido los parámetros del agua (presión, caudal, pérdida de carga) y la geometría requerida en el canal de refrigeración (anchura, rugosidad) para garantizar la correcta refrigeración del bloque de parada. Se ha comprobado que el diseño permite variaciones del haz respecto a la situación nominal siendo el flujo crítico calorífico al menos 2 veces superior al nominal. Se han realizado asimismo simulaciones fluidodinámicas 3D con ANSYS-CFX en aquellas zonas del canal de refrigeración que lo requieren. El bloque de parada se activará como consecuencia de la interacción del haz de partículas lo que impide cualquier cambio o reparación una vez comenzada la operación del acelerador. Por ello el diseño ha de ser muy robusto y todas las hipótesis utilizadas en la realización de éste deben ser cuidadosamente comprobadas. Gran parte del esfuerzo de la tesis se centra en la estimación del coeficiente de transferencia de calor que es determinante en los resultados obtenidos, y que se emplea además como condición de contorno en los cálculos mecánicos. Para ello por un lado se han buscado correlaciones cuyo rango de aplicabilidad sea adecuado para las condiciones del bloque de parada (canal anular, diferencias de temperatura agua-pared de decenas de grados). En un segundo paso se han comparado los coeficientes de película obtenidos a partir de la correlación seleccionada (Petukhov-Gnielinski) con los que se deducen de simulaciones fluidodinámicas, obteniendo resultados satisfactorios. Por último se ha realizado una validación experimental utilizando un prototipo y un circuito hidráulico que proporciona un flujo de agua con los parámetros requeridos en el bloque de parada. Tras varios intentos y mejoras en el experimento se han obtenido los coeficientes de película para distintos caudales y potencias de calentamiento. Teniendo en cuenta la incertidumbre de las medidas, los valores experimentales concuerdan razonablemente bien (en el rango de 15%) con los deducidos de las correlaciones. Por motivos radiológicos es necesario controlar la calidad del agua de refrigeración y minimizar la corrosión del cobre. Tras un estudio bibliográfico se identificaron los parámetros del agua más adecuados (conductividad, pH y concentración de oxígeno disuelto). Como parte de la tesis se ha realizado asimismo un estudio de la corrosión del circuito de refrigeración del bloque de parada con el doble fin de determinar si puede poner en riesgo la integridad del componente, y de obtener una estimación de la velocidad de corrosión para dimensionar el sistema de purificación del agua. Se ha utilizado el código TRACT (TRansport and ACTivation code) adaptándalo al caso del bloque de parada, para lo cual se trabajó con el responsable (Panos Karditsas) del código en Culham (UKAEA). Los resultados confirman que la corrosión del cobre en las condiciones seleccionadas no supone un problema. La Tesis se encuentra estructurada de la siguiente manera: En el primer capítulo se realiza una introducción de los proyectos IFMIF y LIPAc dentro de los cuales se enmarca esta Tesis. Además se describe el bloque de parada, siendo el diseño del sistema de rerigeración de éste el principal objetivo de la Tesis. En el segundo y tercer capítulo se realiza un resumen de la base teórica así como de las diferentes herramientas empleadas en el diseño del sistema de refrigeración. El capítulo cuarto presenta los resultados del relativos al sistema de refrigeración. Tanto los obtenidos del estudio unidimensional, como los obtenidos de las simulaciones fluidodinámicas 3D mediante el empleo del código ANSYS-CFX. En el quinto capítulo se presentan los resultados referentes al análisis de corrosión del circuito de refrigeración del bloque de parada. El capítulo seis se centra en la descripción del montaje experimental para la obtención de los valores de pérdida de carga y coeficiente de transferencia del calor. Asimismo se presentan los resultados obtenidos en dichos experimentos. Finalmente encontramos un capítulo de apéndices en el que se describen una serie de experimentos llevados a cabo como pasos intermedios en la obtención del resultado experimental del coeficiente de película. También se presenta el código informático empleado para el análisis unidimensional del sistema de refrigeración del bloque de parada llamado CHICA (Cooling and Heating Interaction and Corrosion Analysis). ABSTRACT In the nuclear fusion field running in parallel to ITER (International Thermonuclear Experimental Reactor) as one of the complementary activities headed towards solving the technological barriers, IFMIF (International Fusion Material Irradiation Facility) project aims to provide an irradiation facility to qualify advanced materials resistant to extreme conditions like the ones expected in future fusion reactors like DEMO (DEMOnstration Power Plant). IFMIF consists of two constant wave deuteron accelerators delivering a 125 mA and 40 MeV beam each that will collide on a lithium target producing an intense neutron fluence (1017 neutrons/s) with a similar spectra to that of fusion neutrons [1], [2]. This neutron flux is employed to irradiate the different material candidates to be employed in the future fusion reactors, and the samples examined after irradiation at the so called post-irradiative facilities. As a first step in such an ambitious project, an engineering validation and engineering design activity phase called IFMIF-EVEDA (Engineering Validation and Engineering Design Activities) is presently going on. One of the activities consists on the construction and operation of an accelerator prototype named LIPAc (Linear IFMIF Prototype Accelerator). It is a high intensity deuteron accelerator identical to the low energy part of the IFMIF accelerators. The LIPAc components, which will be installed in Japan, are delivered by different european countries. The accelerator supplies a 9 MeV constant wave beam of deuterons with a power of 1.125 MW, which after being characterized by different instruments has to be stopped safely. For such task a beam dump to absorb the beam energy and take it to a heat sink is needed. Spain has the compromise of delivering such device and CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) is responsible for such task. The central piece of the beam dump, where the ion beam is stopped, is a copper cone with an angle of 3.5o, 2.5 m long and 5 mm width. This part is cooled by water flowing on its external surface through the channel formed between the copper cone and a concentric piece with the latter. The thesis is developed in this realm, and its objective is designing the LIPAc beam dump cooling system. The design has been performed employing a simplified one dimensional model. The water parameters (pressure, flow, pressure loss) and the required annular channel geometry (width, rugoisty) have been obtained guaranteeing the correct cooling of the beam dump. It has been checked that the cooling design allows variations of the the beam with respect to the nominal position, being the CHF (Critical Heat Flux) at least twice times higher than the nominal deposited heat flux. 3D fluid dynamic simulations employing ANSYS-CFX code in the beam dump cooling channel sections which require a more thorough study have also been performed. The beam dump will activateasaconsequenceofthe deuteron beam interaction, making impossible any change or maintenance task once the accelerator operation has started. Hence the design has to be very robust and all the hypotheses employed in the design mustbecarefully checked. Most of the work in the thesis is concentrated in estimating the heat transfer coefficient which is decisive in the obtained results, and is also employed as boundary condition in the mechanical analysis. For such task, correlations which applicability range is the adequate for the beam dump conditions (annular channel, water-surface temperature differences of tens of degrees) have been compiled. In a second step the heat transfer coefficients obtained from the selected correlation (Petukhov- Gnielinski) have been compared with the ones deduced from the 3D fluid dynamic simulations, obtaining satisfactory results. Finally an experimental validation has been performed employing a prototype and a hydraulic circuit that supplies a flow with the requested parameters in the beam dump. After several tries and improvements in the experiment, the heat transfer coefficients for different flows and heating powers have been obtained. Considering the uncertainty in the measurements the experimental values agree reasonably well (in the order of 15%) with the ones obtained from the correlations. Due to radiological reasons the quality of the cooling water must be controlled, hence minimizing the copper corrosion. After performing a bibligraphic study the most adequate water parameters were identified (conductivity, pH and dissolved oxygen concentration). As part of this thesis a corrosion study of the beam dump cooling circuit has been performed with the double aim of determining if corrosion can pose a risk for the copper beam dump , and obtaining an estimation of the corrosion velocitytodimension the water purification system. TRACT code(TRansport and ACTivation) has been employed for such study adapting the code for the beam dump case. For such study a collaboration with the code responsible (Panos Karditsas) at Culham (UKAEA) was established. The work developed in this thesis has supposed the publication of three articles in JCR journals (”Journal of Nuclear Materials” y ”Fusion Engineering and Design”), as well as presentations in more than four conferences and relevant meetings.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The engineering of solar power applications, such as photovoltaic energy (PV) or thermal solar energy requires the knowledge of the solar resource available for the solar energy system. This solar resource is generally obtained from datasets, and is either measured by ground-stations, through the use of pyranometers, or by satellites. The solar irradiation data are generally not free, and their cost can be high, in particular if high temporal resolution is required, such as hourly data. In this work, we present an alternative method to provide free hourly global solar tilted irradiation data for the whole European territory through a web platform. The method that we have developed generates solar irradiation data from a combination of clear-sky simulations and weather conditions data. The results are publicly available for free through Soweda, a Web interface. To our knowledge, this is the first time that hourly solar irradiation data are made available online, in real-time, and for free, to the public. The accuracy of these data is not suitable for applications that require high data accuracy, but can be very useful for other applications that only require a rough estimate of solar irradiation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Esta tesis pretende contribuir al fomento y utilización de la energía solar como alternativa para la producción de agua caliente en el sector agroindustrial. La demanda de agua caliente es un aspecto clave en un gran número de agroindustrias y explotaciones agrarias. Esta demanda presenta una gran variabilidad, tanto en los horarios en que se solicita como en la temperatura del agua del depósito requerida (TADr), difiriendo del perfil de demanda habitual para uso doméstico. Existe una necesidad de profundizar en la influencia que tiene la variación de la TADr en la eficiencia y viabilidad de estos sistemas. El objetivo principal de esta tesis es caracterizar el funcionamiento de un sistema solar térmico (SST) con captador de tubos de vacío (CTV) para producir agua a temperaturas superiores a las habituales en estos sistemas. Se pretende determinar la influencia que la TADr tiene sobre la eficiencia energética del sistema, cuantificar el volumen de agua caliente que es capaz de suministrar en función de la TADr y determinar la rentabilidad del SST como sistema complementario de suministro. Para ello, se ha diseñado, instalado y puesto a punto un sistema experimental de calentamiento de agua, monitorizando su funcionamiento a diferentes TADr bajo condiciones ambientales reales. Los resultados cuantifican cómo el aumento de la TADr provoca una disminución de la energía suministrada al depósito, pudiendo superar diferencias de 1000 Wh m-2 d-1 entre 40 ºC y 80 ºC, para valores de irradiación solar próximos a 8000 Wh m-2 d-1 (la eficiencia del sistema oscila entre 73% y 56%). Esta reducción es consecuencia de la disminución de la eficiencia del captador y del aumento de las pérdidas de calor en las tuberías del circuito. En cuanto al agua suministrada, cuanto mayor es la TADr, mayor es la irradiación solar requerida para que tenga lugar la primera descarga de agua, aumentando el tiempo entre descargas y disminuyendo el número de éstas a lo largo del día. A medida que se incrementa la TADr, se produce una reducción del volumen de agua suministrado a la TADr, por factores como la pérdida de eficiencia del captador, las pérdidas en las tuberías, la energía acumulada en el agua que no alcanza la TADr y la mayor energía extraída del sistema en el agua producida. Para una TADr de 80 ºC, una parte importante de la energía permanece acumulada en el depósito sin alcanzar la TADr al final del día. Para aprovechar esta energía sería necesario disponer de un sistema complementario de suministro, ya que las pérdidas de calor nocturnas en el depósito pueden reducir considerablemente la energía útil disponible al día siguiente. La utilización del sistema solar como sistema único de suministro es inviable en la mayoría de los casos, especialmente a TADr elevadas, al no ajustarse la demanda de agua caliente a la estacionalidad de la producción del sistema solar, y al existir muchos días sin producción de agua caliente por la ausencia de irradiación mínima. Por el contrario, la inversión del sistema solar como sistema complementario para suministrar parte de la demanda térmica de una instalación es altamente recomendable. La energía útil anual del sistema solar estimada oscila entre 1322 kWh m-2 y 1084 kWh m-2. La mayor rentabilidad se obtendría suponiendo la existencia de una caldera eléctrica, donde la inversión se recuperaría en pocos años -entre 5.7 años a 40 ºC y 7.2 años a 80 ºC -. La rentabilidad también es elevada suponiendo la existencia de una caldera de gasóleo, con periodos de recuperación inferiores a 10 años. En una industria ficticia con demanda de 100 kWh d-1 y caldera de gasóleo existente, la inversión en una instalación solar optimizada sería rentable a cualquier TADr, con valores de VAN cercanos a la inversión realizada -12000 € a 80 ºC y 15000€ a 40 ºC- y un plazo de recuperación de la inversión entre 8 y 10 años. Los resultados de este estudio pueden ser de gran utilidad a la hora de determinar la viabilidad de utilización de sistemas similares para suministrar la demanda de agua caliente de agroindustrias y explotaciones agropecuarias, o para otras aplicaciones en las que se demande agua a temperaturas distintas de la habitual en uso doméstico (60 ºC). En cada caso, los rendimientos y la rentabilidad vendrán determinados por la irradiación de la zona, la temperatura del agua requerida y la curva de demanda de los procesos específicos. ABSTRACT The aim of this thesis is to contribute to the development and use of solar energy as an alternative for producing hot water in the agribusiness sector. Hot water supply is a key issue for a great many agribusinesses and agricultural holdings. Both hot water demand times and required tank water temperature (rTWT) are highly variable, where the demand profile tends to differ from domestic use. Further research is needed on how differences in rTWT influence the performance and feasibility of these systems. The main objective of this thesis is to characterize the performance and test the feasibility of an evacuated tube collector (ETC) solar water heating (SWH) system providing water at a higher temperature than is usual for such systems. The aim is to determine what influence the rTWT has on the system’s energy efficiency, quantify the volume of hot water that the system is capable of supplying at the respective rTWT and establish whether SWH is feasible as a booster supply system for the different analysed rTWTs. To do this, a prototype water heating system has been designed, installed and commissioned and its performance monitored at different rTWTs under real operating conditions. The quantitative results show that a higher rTWT results in a lower energy supply to the tank, where the differences may be greater than 1000 Wh m-2 d-1 from 40 ºC to 80 ºC for insolation values of around 8000 Wh m-2 d-1 (system efficiency ranges from 73% to 56%). The drop in supply is due to lower collector efficiency and greater heat losses from the pipe system. As regards water supplied at the rTWT, the insolation required for the first withdrawal of water to take place is greater at higher rTWTs, where the time between withdrawals increases and the number of withdrawals decreases throughout the day. As rTWT increases, the volume of water supplied at the rTWT decreases due to factors such as lower collector efficiency, pipe system heat losses, energy stored in the water at below the rTWT and more energy being extracted from the system by water heating. For a rTWT of 80 ºC, much of the energy is stored in the tank at below the rTWT at the end of the day. A booster supply system would be required to take advantage of this energy, as overnight tank heat losses may significantly reduce the usable energy available on the following day. It is often not feasible to use the solar system as a single supply system, especially at high rTWTs, as, unlike the supply from the solar heating system which does not produce hot water on many days of the year because insolation is below the required minimum, hot water demand is not seasonal. On the other hand, investment in a solar system as a booster system to meet part of a plant’s heat energy demand is highly recommended. The solar system’s estimated annual usable energy ranges from 1322 kWh m-2 to 1084 kWh m-2. Cost efficiency would be greatest if there were an existing electric boiler, where the payback period would be just a few years —from 5.7 years at 40 ºC to 7.2 years at 80 ºC—. Cost efficiency is also high if there is an existing diesel boiler with payback periods of under 10 years. In a fictitious industry with a demand of 100 kWh day-1 and an existing diesel boiler, the investment in the solar plant would be highly recommended at any rTWT, with a net present value similar to investment costs —12000 € at 80 ºC and 15000 € at 40 ºC— and a payback period of 10 years. The results of this study are potentially very useful for determining the feasibility of using similar systems for meeting the hot water demand of agribusinesses and arable and livestock farms or for other applications demanding water at temperatures not typical of domestic demand (60ºC). Performance and cost efficiency will be determined by the regional insolation, the required water temperature and the demand curve of the specific processes in each case.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a reliability analysis of a photovoltaic rural electrification (PVRE) programme is proposed considering the failures in the 13 000 installed Solar Home System (SHS) devices occurring over a long operating period of 5 years. A previous arrangement of the database and a brief explanation of the reliability concepts will serve to introduce the failure distribution of every component, from which the SHS lifetime operating features will be described. An application example will show the usefulness of the obtained results in the forecasting of spare parts during the maintenance period. The conclusions of this study may be useful in the scientific design of PVRE programme maintenance structures, with the goal of shedding some light on the technical management mechanisms in decentralised rural electrification.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En esta tesis se investiga de forma experimental el transporte pasivo de magnitudes físicas en micro-sistemas con carácter de inmediata aplicación industrial, usando métodos innovadores para mejorar la eficiencia de los mismos optimizando parámetros críticos del diseño o encontrar nuevos destinos de posible aplicación. Parte de los resultados obtenidos en estos experimentos han sido publicados en revistas con un índice de impacto tal que pertenecen al primer cuarto del JCR. Primero de todo se ha analizado el efecto que produce en un intercambiador de calor basado en micro-canales el hecho de dejar un espacio entre canales y tapa superior para la interconexión de los mismos. Esto genera efectos tridimensionales que mejoran la exracción de calor del intercambiador y reducen la caída de presión que aparece por el transcurso del fluido a través de los micro-canales, lo que tiene un gran impacto en la potencia que ha de suministrar la bomba de refrigerante. Se ha analizado también la mejora producida en términos de calor disipado de un micro-procesador refrigerado con un ampliamente usado plato de aletas al implementar en éste una cámara de vapor que almacena un fluido bifásico. Se ha desarrollado de forma paralela un modelo numérico para optimizar las nuevas dimensiones del plato de aletas modificado compatibles con una serie de requerimientos de diseño en el que tanto las dimensiones como el peso juegan un papel esencial. Por otro lado, se han estudiado los fenomenos fluido-dinámicos que aparecen aguas abajo de un cuerpo romo en el seno de un fluido fluyendo por un canal con una alta relación de bloqueo. Los resultados de este estudio confirman, de forma experimental, la existencia de un régimen intermedio, caracterizado por el desarrollo de una burbuja de recirculación oscilante entre los regímenes, bien diferenciados, de burbuja de recirculación estacionaria y calle de torbellinos de Karman, como función del número de Reynolds del flujo incidente. Para la obtención, análisis y post-proceso de los datos, se ha contado con la ayuda de un sistema de Velocimetría por Imágenes de Partículas (PIV). Finalmente y como adición a este último punto, se ha estudiado las vibraciones de un cuerpo romo producidas por el desprendimiento de torbellinos en un canal de alta relación de bloqueo con la base obtenida del estudio anterior. El prisma se mueve con un movimiento armónico simple para un intervalo de números de Reynolds y este movimiento se transforma en vibración alrededor de su eje a partir de un ciero número de Reynolds. En relación al fluido, el régimen de desprendimiento de torbellinos se alcanza a menores números de Reynolds que en el caso de tener el cuerpo romo fijo. Uniendo estos dos registros de movimientos y variando la relación de masas entre prisma y fluido se obtiene un mapa con diferentes estados globales del sistema. Esto no solo tiene aplicación como método para promover el mezclado sino también como método para obtener energía a partir del movimiento del cuerpo en el seno del fluido. Abstract In this thesis, experimental research focused on passive scalar transport is performed in micro-systems with marked sense of industrial application, using innovative methods in order to obtain better performances optimizing critical design parameters or finding new utilities. Part of the results obtained in these experiments have been published into high impact factor journals belonged to the first quarter of the Journal Citation Reports (JCR). First of all the effect of tip clearance in a micro-channel based heat sink is analyzed. Leaving a gap between channels and top cover, letting the channels communicate each other causes three-dimensional effects which improve the heat transfer between fluid and heat sink and also reducing the pressure drop caused by the fluid passing through the micro-channels which has a great impact on the total cooling pumping power needed. It is also analyzed the enhancement produced in terms of dissipated heat in a micro-processor cooling system by improving the predominantly used fin plate with a vapour chamber based heat spreader which contains a two-phase fluid inside. It has also been developed at the same time a numerical model to optimize the new fin plate dimensions compatible with a series of design requirements in which both size and wight plays a very restrictive role. On the other hand, fluid-dynamics phenomena that appears downstream of a bluff body in the bosom of a fluid flow with high blockage ratio has been studied. This research experimentally confirms the existence of an intermediate regime characterized by an oscillating closed recirculation bubble intermediate regime between the steady closed recirculation bubble regime and the vortex shedding regime (Karman street like regime) as a function of the incoming flow Reynolds number. A particle image velocimetry technique (PIV) has been used in order to obtain, analyze and post-process the fluid-dynamic data. Finally and as an addition to the last point, a study on the vortexinduced vibrations (VIV) of a bluff body inside a high blockage ratio channel has been carried out taking advantage of the results obtained with the fixed square prism. The prism moves with simple harmonic motion for a Reynolds number interval and this movement becomes vibrational around its axial axis after overcoming at definite Reynolds number. Regarding the fluid, vortex shedding regime is reached at Reynolds numbers lower than the previous critical ones. Merging both movement spectra and varying the square prism to fluid mass ratio, a map with different global states is reached. This is not only applicable as a mixing enhancement technique but as an energy harvesting method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Juno, the second mission in the NASA New Frontiers Program, will both be a polar Jovian orbiter, and use solar arrays for power, moving away from previous use of radioisotope power systems (RPSs) in spite of the weak solar light reaching Jupiter. The power generation at Jupiter is critical, and a conductive tether could be an alternative source of power. A current-carrying tether orbiting in a magnetized ionosphere/plasmasphere will radiate waves. A magnitude of interest for both power generation and signal emission is the wave impedance. Jupiter has the strongest magnetic field in the Solar Planetary System and its plasma density is low everywhere. This leads to an electron plasma frequency smaller than the electron cyclotron frequency, and a high Alfven velocity. Unlike the low Earth orbit (LEO) case, the electron skin depth and the characteristic size of plasma contactors affect the Alfven impedance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Leakage power consumption is a com- ponent of the total power consumption in data cen- ters that is not traditionally considered in the set- point temperature of the room. However, the effect of this power component, increased with temperature, can determine the savings associated with the careful management of the cooling system, as well as the re- liability of the system. The work presented in this paper detects the need of addressing leakage power in order to achieve substantial savings in the energy consumption of servers. In particular, our work shows that, by a careful detection and management of two working regions (low and high impact of thermal- dependent leakage), energy consumption of the data- center can be optimized by a reduction of the cooling budget.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Durante los últimos años la tendencia en el sector de las telecomunicaciones ha sido un aumento y diversificación en la transmisión de voz, video y fundamentalmente de datos. Para conseguir alcanzar las tasas de transmisión requeridas, los nuevos estándares de comunicaciones requieren un mayor ancho de banda y tienen un mayor factor de pico, lo cual influye en el bajo rendimiento del amplificador de radiofrecuencia (RFPA). Otro factor que ha influido en el bajo rendimiento es el diseño del amplificador de radiofrecuencia. Tradicionalmente se han utilizado amplificadores lineales por su buen funcionamiento. Sin embargo, debido al elevado factor de pico de las señales transmitidas, el rendimiento de este tipo de amplificadores es bajo. El bajo rendimiento del sistema conlleva desventajas adicionales como el aumento del coste y del tamaño del sistema de refrigeración, como en el caso de una estación base, o como la reducción del tiempo de uso y un mayor calentamiento del equipo para sistemas portátiles alimentados con baterías. Debido a estos factores, se han desarrollado durante las últimas décadas varias soluciones para aumentar el rendimiento del RFPA como la técnica de Outphasing, combinadores de potencia o la técnica de Doherty. Estas soluciones mejoran las prestaciones del RFPA y en algún caso han sido ampliamente utilizados comercialmente como la técnica de Doherty, que alcanza rendimientos hasta del 50% para el sistema completo para anchos de banda de hasta 20MHz. Pese a las mejoras obtenidas con estas soluciones, los mayores rendimientos del sistema se obtienen para soluciones basadas en la modulación de la tensión de alimentación del amplificador de potencia como “Envelope Tracking” o “EER”. La técnica de seguimiento de envolvente o “Envelope Tracking” está basada en la modulación de la tensión de alimentación de un amplificador lineal de potencia para obtener una mejora en el rendimiento en el sistema comparado a una solución con una tensión de alimentación constante. Para la implementación de esta técnica se necesita una etapa adicional, el amplificador de envolvente, que añade complejidad al amplificador de radiofrecuencia. En un amplificador diseñado con esta técnica, se aumentan las pérdidas debido a la etapa adicional que supone el amplificador de envolvente pero a su vez disminuyen las pérdidas en el amplificador de potencia. Si el diseño se optimiza adecuadamente, puede conseguirse un aumento global en el rendimiento del sistema superior al conseguido con las técnicas mencionadas anteriormente. Esta técnica presenta ventajas en el diseño del amplificador de envolvente, ya que el ancho de banda requerido puede ser menor que el ancho de banda de la señal de envolvente si se optimiza adecuadamente el diseño. Adicionalmente, debido a que la sincronización entre la señal de envolvente y de fase no tiene que ser perfecta, el proceso de integración conlleva ciertas ventajas respecto a otras técnicas como EER. La técnica de eliminación y restauración de envolvente, llamada EER o técnica de Kahn está basada en modulación simultánea de la envolvente y la fase de la señal usando un amplificador de potencia conmutado, no lineal y que permite obtener un elevado rendimiento. Esta solución fue propuesta en el año 1952, pero no ha sido implementada con éxito durante muchos años debido a los exigentes requerimientos en cuanto a la sincronización entre fase y envolvente, a las técnicas de control y de corrección de los errores y no linealidades de cada una de las etapas así como de los equipos para poder implementar estas técnicas, que tienen unos requerimientos exigentes en capacidad de cálculo y procesamiento. Dentro del diseño de un RFPA, el amplificador de envolvente tiene una gran importancia debido a su influencia en el rendimiento y ancho de banda del sistema completo. Adicionalmente, la linealidad y la calidad de la señal de transmitida deben ser elevados para poder cumplir con los diferentes estándares de telecomunicaciones. Esta tesis se centra en el amplificador de envolvente y el objetivo principal es el desarrollo de soluciones que permitan el aumento del rendimiento total del sistema a la vez que satisfagan los requerimientos de ancho de banda, calidad de la señal transmitida y de linealidad. Debido al elevado rendimiento que potencialmente puede alcanzarse con la técnica de EER, esta técnica ha sido objeto de análisis y en el estado del arte pueden encontrarse numerosas referencias que analizan el diseño y proponen diversas implementaciones. En una clasificación de alto nivel, podemos agrupar las soluciones propuestas del amplificador de envolvente según estén compuestas de una o múltiples etapas. Las soluciones para el amplificador de envolvente en una configuración multietapa se basan en la combinación de un convertidor conmutado, de elevado rendimiento con un regulador lineal, de alto ancho de banda, en una combinación serie o paralelo. Estas soluciones, debido a la combinación de las características de ambas etapas, proporcionan un buen compromiso entre rendimiento y buen funcionamiento del amplificador de RF. Por otro lado, la complejidad del sistema aumenta debido al mayor número de componentes y de señales de control necesarias y el aumento de rendimiento que se consigue con estas soluciones es limitado. Una configuración en una etapa tiene las ventajas de una mayor simplicidad, pero debido al elevado ancho de banda necesario, la frecuencia de conmutación debe aumentarse en gran medida. Esto implicará un bajo rendimiento y un peor funcionamiento del amplificador de envolvente. En el estado del arte pueden encontrarse diversas soluciones para un amplificador de envolvente en una etapa, como aumentar la frecuencia de conmutación y realizar la implementación en un circuito integrado, que tendrá mejor funcionamiento a altas frecuencias o utilizar técnicas topológicas y/o filtros de orden elevado, que permiten una reducción de la frecuencia de conmutación. En esta tesis se propone de manera original el uso de la técnica de cancelación de rizado, aplicado al convertidor reductor síncrono, para reducir la frecuencia de conmutación comparado con diseño equivalente del convertidor reductor convencional. Adicionalmente se han desarrollado dos variantes topológicas basadas en esta solución para aumentar la robustez y las prestaciones de la misma. Otro punto de interés en el diseño de un RFPA es la dificultad de poder estimar la influencia de los parámetros de diseño del amplificador de envolvente en el amplificador final integrado. En esta tesis se ha abordado este problema y se ha desarrollado una herramienta de diseño que permite obtener las principales figuras de mérito del amplificador integrado para la técnica de EER a partir del diseño del amplificador de envolvente. Mediante el uso de esta herramienta pueden validarse el efecto del ancho de banda, el rizado de tensión de salida o las no linealidades del diseño del amplificador de envolvente para varias modulaciones digitales. Las principales contribuciones originales de esta tesis son las siguientes: La aplicación de la técnica de cancelación de rizado a un convertidor reductor síncrono para un amplificador de envolvente de alto rendimiento para un RFPA linealizado mediante la técnica de EER. Una reducción del 66% en la frecuencia de conmutación, comparado con el reductor convencional equivalente. Esta reducción se ha validado experimentalmente obteniéndose una mejora en el rendimiento de entre el 12.4% y el 16% para las especificaciones de este trabajo. La topología y el diseño del convertidor reductor con dos redes de cancelación de rizado en cascada para mejorar el funcionamiento y robustez de la solución con una red de cancelación. La combinación de un convertidor redactor multifase con la técnica de cancelación de rizado para obtener una topología que proporciona una reducción del cociente entre frecuencia de conmutación y ancho de banda de la señal. El proceso de optimización del control del amplificador de envolvente en lazo cerrado para mejorar el funcionamiento respecto a la solución en lazo abierto del convertidor reductor con red de cancelación de rizado. Una herramienta de simulación para optimizar el proceso de diseño del amplificador de envolvente mediante la estimación de las figuras de mérito del RFPA, implementado mediante EER, basada en el diseño del amplificador de envolvente. La integración y caracterización del amplificador de envolvente basado en un convertidor reductor con red de cancelación de rizado en el transmisor de radiofrecuencia completo consiguiendo un elevado rendimiento, entre 57% y 70.6% para potencias de salida de 14.4W y 40.7W respectivamente. Esta tesis se divide en seis capítulos. El primer capítulo aborda la introducción enfocada en la aplicación, los amplificadores de potencia de radiofrecuencia, así como los principales problemas, retos y soluciones existentes. En el capítulo dos se desarrolla el estado del arte de amplificadores de potencia de RF, describiéndose las principales técnicas de diseño, las causas de no linealidad y las técnicas de optimización. El capítulo tres está centrado en las soluciones propuestas para el amplificador de envolvente. El modo de control se ha abordado en este capítulo y se ha presentado una optimización del diseño en lazo cerrado para el convertidor reductor convencional y para el convertidor reductor con red de cancelación de rizado. El capítulo cuatro se centra en el proceso de diseño del amplificador de envolvente. Se ha desarrollado una herramienta de diseño para evaluar la influencia del amplificador de envolvente en las figuras de mérito del RFPA. En el capítulo cinco se presenta el proceso de integración realizado y las pruebas realizadas para las diversas modulaciones, así como la completa caracterización y análisis del amplificador de RF. El capítulo seis describe las principales conclusiones de la tesis y las líneas futuras. ABSTRACT The trend in the telecommunications sector during the last years follow a high increase in the transmission rate of voice, video and mainly in data. To achieve the required levels of data rates, the new modulation standards demand higher bandwidths and have a higher peak to average power ratio (PAPR). These specifications have a direct impact in the low efficiency of the RFPA. An additional factor for the low efficiency of the RFPA is in the power amplifier design. Traditionally, linear classes have been used for the implementation of the power amplifier as they comply with the technical requirements. However, they have a low efficiency, especially in the operating range of signals with a high PAPR. The low efficiency of the transmitter has additional disadvantages as an increase in the cost and size as the cooling system needs to be increased for a base station and a temperature increase and a lower use time for portable devices. Several solutions have been proposed in the state of the art to improve the efficiency of the transmitter as Outphasing, power combiners or Doherty technique. However, the highest potential of efficiency improvement can be obtained using a modulated power supply for the power amplifier, as in the Envelope Tracking and EER techniques. The Envelope Tracking technique is based on the modulation of the power supply of a linear power amplifier to improve the overall efficiency compared to a fixed voltage supply. In the implementation of this technique an additional stage is needed, the envelope amplifier, that will increase the complexity of the RFPA. However, the efficiency of the linear power amplifier will increase and, if designed properly, the RFPA efficiency will be improved. The advantages of this technique are that the envelope amplifier design does not require such a high bandwidth as the envelope signal and that in the integration process a perfect synchronization between envelope and phase is not required. The Envelope Elimination and Restoration (EER) technique, known also as Kahn’s technique, is based on the simultaneous modulation of envelope and phase using a high efficiency switched power amplifier. This solution has the highest potential in terms of the efficiency improvement but also has the most challenging specifications. This solution, proposed in 1952, has not been successfully implemented until the last two decades due to the high demanding requirements for each of the stages as well as for the highly demanding processing and computation capabilities needed. At the system level, a very precise synchronization is required between the envelope and phase paths to avoid a linearity decrease of the system. Several techniques are used to compensate the non-linear effects in amplitude and phase and to improve the rejection of the out of band noise as predistortion, feedback and feed-forward. In order to obtain a high bandwidth and efficient RFPA using either ET or EER, the envelope amplifier stage will have a critical importance. The requirements for this stage are very demanding in terms of bandwidth, linearity and quality of the transmitted signal. Additionally the efficiency should be as high as possible, as the envelope amplifier has a direct impact in the efficiency of the overall system. This thesis is focused on the envelope amplifier stage and the main objective will be the development of high efficiency envelope amplifier solutions that comply with the requirements of the RFPA application. The design and optimization of an envelope amplifier for a RFPA application is a highly referenced research topic, and many solutions that address the envelope amplifier and the RFPA design and optimization can be found in the state of the art. From a high level classification, multiple and single stage envelope amplifiers can be identified. Envelope amplifiers for EER based on multiple stage architecture combine a linear assisted stage and a switched-mode stage, either in a series or parallel configuration, to achieve a very high performance RFPA. However, the complexity of the system increases and the efficiency improvement is limited. A single-stage envelope amplifier has the advantage of a lower complexity but in order to achieve the required bandwidth the switching frequency has to be highly increased, and therefore the performance and the efficiency are degraded. Several techniques are used to overcome this limitation, as the design of integrated circuits that are capable of switching at very high rates or the use of topological solutions, high order filters or a combination of both to reduce the switching frequency requirements. In this thesis it is originally proposed the use of the ripple cancellation technique, applied to a synchronous buck converter, to reduce the switching frequency requirements compared to a conventional buck converter for an envelope amplifier application. Three original proposals for the envelope amplifier stage, based on the ripple cancellation technique, are presented and one of the solutions has been experimentally validated and integrated in the complete amplifier, showing a high total efficiency increase compared to other solutions of the state of the art. Additionally, the proposed envelope amplifier has been integrated in the complete RFPA achieving a high total efficiency. The design process optimization has also been analyzed in this thesis. Due to the different figures of merit between the envelope amplifier and the complete RFPA it is very difficult to obtain an optimized design for the envelope amplifier. To reduce the design uncertainties, a design tool has been developed to provide an estimation of the RFPA figures of merit based on the design of the envelope amplifier. The main contributions of this thesis are: The application of the ripple cancellation technique to a synchronous buck converter for an envelope amplifier application to achieve a high efficiency and high bandwidth EER RFPA. A 66% reduction of the switching frequency, validated experimentally, compared to the equivalent conventional buck converter. This reduction has been reflected in an improvement in the efficiency between 12.4% and 16%, validated for the specifications of this work. The synchronous buck converter with two cascaded ripple cancellation networks (RCNs) topology and design to improve the robustness and the performance of the envelope amplifier. The combination of a phase-shifted multi-phase buck converter with the ripple cancellation technique to improve the envelope amplifier switching frequency to signal bandwidth ratio. The optimization of the control loop of an envelope amplifier to improve the performance of the open loop design for the conventional and ripple cancellation buck converter. A simulation tool to optimize the envelope amplifier design process. Using the envelope amplifier design as the input data, the main figures of merit of the complete RFPA for an EER application are obtained for several digital modulations. The successful integration of the envelope amplifier based on a RCN buck converter in the complete RFPA obtaining a high efficiency integrated amplifier. The efficiency obtained is between 57% and 70.6% for an output power of 14.4W and 40.7W respectively. The main figures of merit for the different modulations have been characterized and analyzed. This thesis is organized in six chapters. In Chapter 1 is provided an introduction of the RFPA application, where the main problems, challenges and solutions are described. In Chapter 2 the technical background for radiofrequency power amplifiers (RF) is presented. The main techniques to implement an RFPA are described and analyzed. The state of the art techniques to improve performance of the RFPA are identified as well as the main sources of no-linearities for the RFPA. Chapter 3 is focused on the envelope amplifier stage. The three different solutions proposed originally in this thesis for the envelope amplifier are presented and analyzed. The control stage design is analyzed and an optimization is proposed both for the conventional and the RCN buck converter. Chapter 4 is focused in the design and optimization process of the envelope amplifier and a design tool to evaluate the envelope amplifier design impact in the RFPA is presented. Chapter 5 shows the integration process of the complete amplifier. Chapter 6 addresses the main conclusions of the thesis and the future work.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Assuring the sustainability of quality in photovoltaic rural electrification programmes involves enhancing the reliability of the components of solar home systems as well as the characterization of the overall programme cost structure. Batteries and photovoltaic modules have a great impact on both the reliability and the cost assessment, the battery being the weakest component of the solar home system and consequently the most expensive element of the programme. The photovoltaic module, despite being the most reliable component, has a significant impact cost-wise on the initial investment, even at current market prices. This paper focuses on the in-field testing of both batteries and photovoltaic modules working under real operating conditions within a sample of 41 solar home systems belonging to a large photovoltaic rural electrification programme with more than 13,000 installed photovoltaic systems. Different reliability parameters such as lifetime have been evaluated, taking into account different factors, for example energy consumption rates, or the manufacturing quality of batteries. A degradation model has been proposed relating both loss of capacity and time of operation. The user e solar home system binomial is also analysed in order to understand the meaning of battery lifetime in rural electrification.