6 resultados para Rolle of Stevenstone, John Rolle, Baron, 1750-1842.
em Universidad Politécnica de Madrid
Resumo:
In this paper the very first geochemical and isotopic data related to surface and spring waters and dissolved gases in the area of Hontomín–Huermeces (Burgos, Spain) are presented and discussed. Hontomín–Huermeces has been selected as a pilot site for the injection of pure (>99%) CO2. Injection and monitoring wells are planned to be drilled close to 6 oil wells completed in the 1980s for which detailed stratigraphical logs are available, indicating the presence of a confined saline aquifer at the depth of about 1500 m into which less than 100,000 tons of iquid CO2 will be injected, possibly starting in 2013. The chemical and features of the spring waters suggest that they are related to a shallow hydrogeological system as the concentration of the Total Dissolved Solids approaches 800 mg/L with a Ca2+(Mg2+)-HCO3− composition, similar to that of the surface waters. This is also supported by the oxygen and hydrogen isotopic ratios that have values lying between those of the Global and the Mediterranean Meteoric Water Lines. Some spring waters close to the oil wells are haracterized by relatively high concentrations of NO3− (up to 123 mg/L), unequivocally suggesting an anthropogenic source that adds to the main water–rock interaction processes. The latter can be referred to Ca-Mg-carbonate and, at a minor extent, Al-silicate dissolution, being the outcropping sedimentary rocks characterized by Palaeozoic to Quaternary rocks. Anomalous concentrations of Cl−, SO42−, As, B and Ba were measured in two springs discharging a few hundred meters from the oil wells and in the Rio Ubierna. These contents are significantly higher than those of the whole set of the studied waters and are possibly indicative of mixing processes, although at very low extent, between deep and shallow aquifers. No evidence of deep-seated gases interacting with the Hontomín–Huermeces waters was recognized in the chemistry of the disolved gases. This is likely due to the fact that they are mainly characterized by an atmospheric source as highlighted by the high contents of N2, O2 and Ar and by N2/Ar ratios that approach that of ASW (Air Saturated Water) and possibly masking any contribution related to a deep source. Nevertheless, significant concentrations (up to 63% by vol.) of isotopically negative CO2 (<−17.7‰ V-PDB) were found in some water samples, likely related to a biogenic source. The geochemical and isotopic data of this work are of particular importance when a monitoring program will be established to verify whether CO2 leakages, induced by the injection of this greenhouse gas, may be affecting the quality of the waters in the shallow hydrological circuits at Hontomín–Huermeces. In this respect, carbonate chemistry, the isotopic carbon of dissolved CO2 and TDIC (Total Dissolved Inorganic Carbon) and selected trace elements can be considered as useful parameters to trace the migration of the injected CO2 into near-surface environments.
Resumo:
Fundación Ciudad de la Energía (CIUDEN) is carrying out a project of geological storage of CO2, where CO2 injection tests are planned in saline aquifers at a depth of 1500 m for scientific objectives and project demonstration. Before any CO2 is stored, it is necessary to determine the baseline flux of CO2 in order to detect potential leakage during injection and post-injection monitoring. In November 2009 diffuse flux measurements of CO2 using an accumulation chamber were made in the area selected by CIUDEN for geological storage, located in Hontomin province of Burgos (Spain). This paper presents the tests carried out in order to establish the optimum sampling methodology and the geostatistical analyses performed to determine the range, with which future field campaigns will be planned.
Resumo:
Natural analogs offer a valuable opportunity to investigate the long-term impacts associated with thepotential leakage in geological storage of CO2.Degassing of CO2and radon isotopes (222Rn?220Rn) from soil, gas vents and thermal water dischargeswas investigated in the natural analog of Campo de Calatrava Volcanic Field (CCVF; Central Spain) todetermine the CO2?Rn relationships and to assess the role of CO2as carrier gas for radon. Furthermore,radon measurements to discriminate between shallow and deep gas sources were evaluated under theperspective of their applicability in monitoring programs of carbon storage projects.CO2flux as high as 5000 g m?2d?1and222Rn activities up to 430 kBq m?3were measured;220Rn activi-ties were one order of magnitude lower than those of222Rn. The222Rn/220Rn ratios were used to constrainthe source of the Campo de Calatrava soil gases since a positive correlation between radon isotopic ratiosand CO2fluxes was observed. Thus, in agreement with previous studies, our results indicate a deepmantle-related origin of CO2for both free and soil gases, suggesting that carbon dioxide is an efficientcarrier for Rn. Furthermore, it was ascertained that the increase of222Rn in the soil gases was likely pro-duced by two main processes: (i) direct transport by a carrier gas, i.e., CO2and (ii) generation at shallowlevel due to the presence of relatively high concentrations of dissolved U and Ra in the thermal aquiferof Campo de Calatrava.The diffuse CO2soil flux and radon isotopic surveys carried out in the Campo de Calatrava VolcanicFields can also be applicable to geochemical monitoring programs in CCS (Carbon Capture and Storage)areas as these parameters are useful to: (i) constrain CO2leakages once detected and (ii) monitor both theevolution of the leakages and the effectiveness of subsequent remediation activities. These measurementscan also conveniently be used to detect diffuse leakages.
Resumo:
In memoriam of Professor John Munro was born in Glasgow the 8th of July 1925 and died on Wednesday 27th February 1985. He graduated in Civil Engineering at Glasgow University in 1951
Resumo:
Fundación Ciudad de la Energía (CIUDEN) is carrying out a project of geological storage of CO2, where CO2 injection tests are planned in saline aquifers at a depth of 1500 m for scientific objectives and project demonstration. Before any CO2 is stored, it is necessary to determine the baseline flux of CO2 in order to detect potential leakage during injection and post-injection monitoring. In November 2009 diffuse flux measurements of CO2 using an accumulationchamber were made in the area selected by CIUDEN for geological storage, located in Hontomin province of Burgos (Spain). This paper presents the tests carried out in order to establish the optimum sampling methodology and the geostatistical analyses performed to determine the range, with which future field campaigns will be planned.
Resumo:
From the end of 2013 and during the following two years, 20 kt of CO2sc are planned to be injected in a saline reservoir (1500 m depth) at the Hontomín site (NE Spain). The target aquifers are Lower Jurassic limestone formations which are sealed by Lower Cretaceous clay units at the Hontomín site (NE Spain). The injection of CO2 is part of the activities committed in the Technology Development phase of the EC-funded OXYCFB300 project (European Energy Program for Recovery – EEPR, http://www.compostillaproject.eu), which include CO2 injection strategies, risk assessment, and testing and validating monitoring methodologies and techniques. Among the monitoring works, the project is intended to prove that present-day technology is able to monitor the evolution of injected CO2 in the reservoir and to detect potential leakage. One of the techniques is the measurement of CO2 flux at the soil–atmosphere interface, which includes campaigns before, during and after the injection operations. In this work soil CO2 flux measurements in the vicinity of oil borehole, drilled in the eighties and named H-1 to H-4, and injection and monitoring wells were performed using an accumulation chamber equipped with an IR sensor. Seven surveys were carried out from November 2009 to summer 2011. More than 4000 measurements were used to determine the baseline flux of CO2 and its seasonal variations. The measured values were low (from 5 to 13 g m−2 day−1) and few outliers were identified, mainly located close to the H-2 oil well. Nevertheless, these values cannot be associated to a deep source of CO2, being more likely related to biological processes, i.e. soil respiration. No anomalies were recognized close to the deep fault system (Ubierna Fault) detected by geophysical investigations. There, the CO2 flux is indeed as low as other measurement stations. CO2 fluxes appear to be controlled by the biological activity since the lowest values were recorded during autumn-winter seasons and they tend to increase in warm periods. Two reference CO2 flux values (UCL50 of 5 g m−2 d−1 for non-ploughed areas in autumn–winter seasons and 3.5 and 12 g m−2 d−1 for in ploughed and non-ploughed areas, respectively, in spring–summer time, and UCL99 of 26 g m−2 d−1 for autumn–winter in not-ploughed areas and 34 and 42 g m−2 d−1 for spring–summer in ploughed and not-ploughed areas, respectively) were calculated. Fluxes higher than these reference values could be indicative of possible leakage during the operational and post-closure stages of the storage project.