3 resultados para Resistivity Instrumentation
em Universidad Politécnica de Madrid
Resumo:
Concentrator photovoltaic is an emergent technology that may be a good economical and efficient alternative for the generation of electricity at a competitive cost. However, the reliability of these new solar cells and systems is still an open issue due to the high-irradiation level they are subjected to as well as the electrical and thermal stresses that they are expected to endure. To evaluate the reliability in a short period of time, accelerated aging tests are essential. Thermal aging tests for concentrator photovoltaic solar cells and systems under illumination are not available because no technical solution to the problem of reaching the working concentration inside a climatic chamber has been available. This work presents an automatic instrumentation system that overcomes the aforementioned limitation. Working conditions have been simulated by forward biasing the solar cells to the current they would handle at the working concentration (in this case, 700 and 1050 times the irradiance at one standard sun). The instrumentation system has been deployed for more than 10 000 h in a thermal aging test for III-V concentrator solar cells, in which the generated power evolution at different temperatures has been monitored. As a result of this test, the acceleration factor has been calculated, thus allowing for the degradation evolution at any temperature in addition to normal working conditions to be obtained.
Resumo:
Debido al carácter innovador de los objetivos científico-tecnológicos planteados al inicio de la presente Tesis doctoral, además de la primera recopilación bibliográfica, a lo largo del desarrollo de la misma se ha realizado una actualización bibliográfica continua centrada en los desarrollos relativos a la instrumentación, las aplicaciones y los procesos de interpretación de las técnicas de tomografía eléctrica. Durante el desarrollo del presente trabajo, se han realizado una serie de campañas diferenciadas, tanto por los ambientes geológicos y las condiciones antrópicas en los que se han efectuado los perfiles geoeléctricos, como por la profundidad y los objetivos de la prospección. En esas campañas se han obtenido, mediante el programa Res2DInv, las secciones tomográficas con la configuración de variables por defecto y se ha realizado una interpretación estructural de las mismas. Como parte central del desarrollo de esta investigación se han efectuado varios procesos de optimización: Comparación y optimización de los dispositivos empleados para la medición de perfiles de resistividad de cara a la obtención de secciones tomográficas que presenten la mayor resolución en distintos ambientes geológicos. Selección de los rangos de representación (lineales y logarítmicos) y de la gradación cromática que, pudiendo adoptarse de forma generalizada, permita la mejor interpretación gráfica para usuarios no avanzados. Diseño de criterios para la selección del factor de amortiguamiento, como parámetro crítico en los procesos de inversión tomográfica de perfiles geoeléctricos de superficie, de forma que los modelos resultantes alcancen la mejor relación entre fiabilidad y error respecto a los valores medidos. Paralelamente a los procesos anteriores se ha definido un índice de calidad de la inversión, que es directamente normalizado y que permite evaluar el grado en el que pueden considerarse fiables tanto los valores de resistividad obtenidos como su distribución espacial. El índice desarrollado (IRI) está basado en la influencia que tiene la resistividad inicial del modelo de inversión en los valores de cada una de las celdas de la malla de inversión. Tras un exhaustivo análisis estadístico se ha verificado que, a diferencia de otros índices utilizados hasta la fecha, dicho índice no está afectado ni por la profundidad de investigación y la resolución de los dispositivos, ni por la distribución de resistividades que presente el subsuelo. ABSTRACT Due to the innovative character of the scientific and technological objectives proposed at the beginning of this thesis, in addition to preparatory bibliographic reference, a constant bibliographic update on developments related to instrumentation, applications and interpretation processes for electric tomography has been performed all through the development of the work. Several measuring campaigns were performed during the development of the thesis. These campaigns, in which the geoelectric profiles were measured, varied in several aspects, both in the geological and anthropic conditions, and also in the depth and objectives of the prospection. Tomographic sections were obtained and interpretated by making use of the Res2DInv software configured with the default variables. As part of the core development in this research, several optimization processes have been done: Comparison and optimization of the devices used in the measurement of resistivity profiles. This optimization allows increasing the resolution of tomographic sections in different geological conditions. Selection of the best visual representation for the tomographic sections. This involves the selection of the range of values and type of scale (linear vs. logarithmic) as well as the chromatic graduation. This selection allows improving the interpretation of tomographic sections for the non-expert eye. Devising of criteria for the selection of the damping factor, as the critical parameter in processes of tomographic inversion of superficial geoelectrical profiles. The use of these criteria allows selecting the best factors to obtain the best ratio between reliability and error (in relation to the mean values) for the resulting model. In addition to the aforementioned processes, and as part of the work within this thesis, it has been defined a normalized quality index for inversion. This index allows evaluating the degree of reliability of the obtained resistivity values and spatial distribution. The developed index, termed IRI in the thesis, is based on the influence shown by the initial resistivity of the inversion model on the values of each of the cells of the inversion mesh. After an exhaustive statistical analysis it was verified that the IRI index is neither affected by the investigation depth, nor the resolution of the devices, nor the resistivity’s distribution of the sub soil. This independency is a unique characteristic of the IRI index, not present in other indexes developed and used till date.
Resumo:
Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.