5 resultados para Remotely Monitoring Exercise, Cardiac Rehabiliation
em Universidad Politécnica de Madrid
Resumo:
Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.
Resumo:
Introducción: Diversos cambios ocurren en el sistema cardiovascular materno durante el embarazo, lo que genera un gran estrés sobre este sistema especialmente durante el tercer trimestre, pudiendo acentuarse en presencia de determinados factores de riesgo. Los objetivos de este estudio fueron, valorar las adaptaciones cardiovasculares producidas por un programa específico de ejercicio físico; su seguridad sobre el sistema cardiovascular materno y los resultados del embarazo; y su eficacia en el control de los factores de riesgo cardiovascular. Material y métodos: El diseño del estudio fue un ensayo clínico aleatorizado. 151 gestantes sanas fueron evaluadas mediante un ecocardiograma y un electrocardiograma en la semana 20 y 34 de gestación. Un total de 89 gestantes participaron en un programa de ejercicio físico (GE) desde el primer hasta el tercer trimestre de embarazo, constituido principalmente por 25-30 minutos de trabajo aeróbico (55-60% de la frecuencia cardiaca de reserva), trabajo de fortalecimiento general y específico, y un trabajo de tonificación del suelo pélvico; desarrollado 3 días a la semana con una duración de 55-60 minutos cada sesión. Las gestantes aleatoriamente asignadas al grupo de control (GC; n=62) permanecieron sedentarias durante el embarazo. El estudio fue aprobado por el Comité Ético de investigación clínica del Hospital Universitario de Fuenlabrada. Resultados: Las características basales fueron similares entre ambos grupos. A diferencia del GC, las gestantes del GE evitaron el descenso significativo del gasto cardiaco indexado, entre el 2º y 3ºT de embarazo, y conservaron el patrón geométrico normal del ventrículo izquierdo; mientras que en el GC cambió hacia un patrón de remodelado concéntrico. En la semana 20, las gestantes del GE presentaron valores significativamente menores de frecuencia cardiaca (GC: 79,56±10,76 vs. GE: 76,05±9,34; p=0,04), tensión arterial sistólica (GC: 110,19±10,23 vs. GE: 106,04±12,06; p=0,03); tensión arterial diastólica (GC: 64,56±7,88 vs. GE: 61,81±7,15; p=0,03); tiempo de relajación isovolumétrica (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); y un mayor tiempo de deceleración de la onda E (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). En la semana 34, el GE presentó valores significativamente superiores de volumen sistólico (GC: 51,13±11,85 vs. GE: 56,21±12,79 p=0,04), de llenado temprano del ventrículo izquierdo (E) (GC: 78,38±14,07 vs. GE: 85,30±16,62; p=0,02) y de tiempo de deceleración de la onda E (GC: 130,35±37,11 vs. GE: 146,61±43,40; p=0,04). Conclusión: La práctica regular de ejercicio físico durante el embarazo puede producir adaptaciones positivas sobre el sistema cardiovascular materno durante el tercer trimestre de embarazo, además de ayudar en el control de sus factores de riesgo, sin alterar la salud materno-fetal. ABSTRACT Background: Several changes occur in the maternal cardiovascular system during pregnancy. These changes produce a considerable stress in this system, especially during the third trimester, which can be increased in presence of some risk factors. The aims of this study were, to assess the maternal cardiac adaptations in a specific exercise program; its safety on the maternal cardiovascular system and pregnancy outcomes; and its effectiveness in the control of cardiovascular risk factors. Material and methods: A randomized controlled trial was designed. 151 healthy pregnant women were assessed by an echocardiography and electrocardiography at 20 and 34 weeks of gestation. A total of 89 pregnant women participated in a physical exercise program (EG) from the first to the third trimester of pregnancy. It consisted of 25-30 minutes of aerobic conditioning (55-60% of their heart rate reserve), general and specific strength exercises, and a pelvic floor muscles training; 3 times per weeks during 55-60 minutes per session. Pregnant women randomized allocated to the control group (CG) remained sedentary during pregnancy. The study was approved by the Research Ethics Committee of Hospital Universitario de Fuenlabrada. Results: Baseline characteristics were similar between groups. Difference from the CG, pregnant women from the EG prevented the significant decrease of the cardiac output index, between the 2nd and 3rd trimester of pregnancy, and preserved the normal left ventricular pattern; whereas in the CG shifted to concentric remodeling pattern. At 20 weeks, women in the EG had significant lower heart rate (CG: 79,56±10,76 vs. EG: 76,05±9,34; p=0,04), systolic blood pressure (CG: 110,19±10,23 vs. EG: 106,04±12,06; p=0,03); diastolic blood pressure (CG: 64,56±7,88 vs. EG: 61,81±7,15; p=0,03); isovolumetric relaxation time (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); and a higher deceleration time of E Wave (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). At 34 weeks, the EG had a significant higher stroke volume (CG: 51,13±11,85 vs. EG: 56,21±12,79 p=0,04), early filling of left ventricular (E) (CG: 78,38±14,07 vs. EG: 85,30±16,62; p=0,02) and deceleration time of E wave (CG: 130,35±37,11 vs. EG:146,61±43,40; p=0,04). Conclusion: Physical regular exercise program during pregnancy may produce positive maternal cardiovascular adaptations during the third trimester of pregnancy. In addition, it helps to control the cardiovascular risk factors without altering maternal and fetus health.
Resumo:
This paper describes the design and development of a system for cardio rehabilitation of patients that suffered a myocardial infarction. The proposed solution focuses on exercise prescriptions and the encouragement of healthy behaviors. The innovative strategy of the design takes into account health promotion models to provide safe, assistive exercise training sessions, personalized feedbacks, and educational contents.
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
It is essential to remotely and continuously monitor the movements of individuals in many social areas, for example, taking care of aging people, physical therapy, athletic training etc. Many methods have been used, such as video record, motion analysis or sensor-based methods. Due to the limitations in remote communication, power consumption, portability and so on, most of them are not able to fulfill the requirements. The development of wearable technology and cloud computing provides a new efficient way to achieve this goal. This paper presents an intelligent human movement monitoring system based on a smartwatch, an Android smartphone and a distributed data management engine. This system includes advantages of wide adaptability, remote and long-term monitoring capacity, high portability and flexibility. The structure of the system and its principle are introduced. Four experiments are designed to prove the feasibility of the system. The results of the experiments demonstrate the system is able to detect different actions of individuals with adequate accuracy.