19 resultados para Prestressed concrete

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an analytical model for simulating the bond between steel and concrete, in precast prestressed concrete elements, during the prestressing force release. The model establishes a relationship between bond stress, steel and concrete stress and slip in such concrete structures. This relationship allows us to evaluate the bond stress in the transmission zone, where bond stress is not constant, along the whole prestressing force release process. The model is validated with the results of a series of tests and is extended to evaluate the transmission length. This capability has been checked by comparing the transmission length predicted by the model and one measured experimentally in a series of tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an analytical model for simulating the bond between steel and concrete, in precast prestressed concrete elements, during the prestressing force release. The model establishes a relationship between bond stress, steel and concrete stress and slip in such concrete structures. This relationship allows us to evaluate the bond stress in the transmission zone, where bond stress is not constant, along the whole prestressing force release process. The model is validated with the results of a series of tests, considering different steel indentation depths and concrete covers and is extended to evaluate the transmission length. This capability has been checked by comparing the transmission length predicted by the model and one measured experimentally in two series of tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents two test procedures for evaluating the bond stress–slip and the slip–radial dilation relationships when the prestressing force is transmitted by releasing the steel (wire or strand) in precast prestressed elements. The bond stress–slip relationship is obtained with short length specimens, to guarantee uniform bond stress, for three depths of the wire indentation (shallow, medium and deep). An analytical model for bond stress–slip relationship is proposed and compared with the experimental results. The model is also compared with the experimental results of other researchers. Since numerical models for studying bond-splitting problems in prestressed concrete require experimental data about dilatancy angle (radial dilation), a test procedure is proposed to evaluate these parameters. The obtained values of the radial dilation are compared with the prior estimated by numerical modelling and good agreement is reached

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Damage tolerance of high strength cold-drawn ferritic–austenitic stainless steel wires is assessed by means of tensile fracture tests of cracked wires. The fatigue crack is transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behaviour is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D is used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plane specimens extracted from the cold-drawn wires. Finally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic–austenitic stainless steel wires is compared with that of an elementary plastic collapse model and existing data of two types of high strength eutectoid steel currently used as prestressing steel for concrete.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bond analytical model is proposed in this paper. The model is capable of reproducing the bond stress developed between the steel and concrete, in precast prestressed elements, during the entire process of prestressing force release. The bond stress developed in the transmission zone, where the bond stress is not constant, is also obtained. The steel and concrete stresses as well as the slip between both materials can be also estimated by means of the relation established in the model between these parameters and the bond stress. The model is validated with the results of a series of tests, considering different steel indentation depths and concrete covers and it is extended to evaluate the transmission length. This has been checked by comparing the transmission length predicted by the model and one measured experimentally in two series of tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bond analytical model is proposed in this paper. The model is capable of reproducing the bond stress developed between the steel and concrete, in precast prestressed elements, during the entire process of prestressing force release. The bond stress developed in the transmission zone, where the bond stress is not constant, is also obtained. The steel and concrete stresses as well as the slip between both materials can be also estimated by means of the relation established in the model between these parameters and the bond stress. The model is validated with the results of a series of tests, considering different steel indentation depths and concrete covers and it is extended to evaluate the transmission length. This has been checked by comparing the transmission length predicted by the model and one measured experimentally in two series of tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper a summary of the methods presently used for optimization of prestressed concrete bridge decks is given. By means of linear optimization the sizes of the prestressing cables with a given fixed geometry are obtained. This simple procedure of linear optimization is also used to obtain the ‘best’ cable profile, by combining a series of feasible cable profiles. The results are compared with the ones obtained by other researchers. A step ahead in the field of optimization of prestressed bridge decks is the simultaneous search of the geometry and size of the prestressing cables. A non-linear programming for optimization is used, namely, ‘the steepest gradient method’. The results obtained are compared with the ones computed previously by means of linear programming techniques. Finally, the general problem of structural optimization is considered. This problem consists in finding the sizes and geometries of the prestressing cables as well as the longitudinal variation of the concrete section.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La mayoría de las estructuras de hormigón pretensadas construidas en los últimos 50 años han demostrado una excelente durabilidad cuando su construcción se realiza atendiendo las recomendaciones de un buen diseño así como una buena ejecución y puesta en obra de la estructura. Este hecho se debe en gran parte al temor que despierta el fenómeno de la corrosión bajo tensión típico de las armaduras de acero de alta resistencia. Menos atención se ha prestado a la susceptibilidad a la corrosión bajo tensión de los anclajes de postensado, posiblemente debido a que se han reportado pocos casos de fallos catastróficos. El concepto de Tolerancia al Daño y la Mecánica de la Fractura en estructuras de Ingeniería Civil ha empezado a incorporarse recientemente en algunas normas de diseño y cálculo de estructuras metálicas, sin embargo, aún está lejos de ser asimilado y empleado habitualmente por los ingenieros en sus cálculos cuando la ocasión lo requiere. Este desconocimiento de los aspectos relacionados con la Tolerancia al Daño genera importantes gastos de mantenimiento y reparación. En este trabajo se ha estudiado la aplicabilidad de los conceptos de la Mecánica de la Fractura a los componentes de los sistemas de postensado empleados en ingeniería civil, empleándolo para analizar la susceptibilidad de las armaduras activas frente a la corrosión bajo tensiones y a la pérdida de capacidad portante de las cabezas de anclajes de postensado debido a la presencia de defectos. Con este objeto se han combinado tanto técnicas experimentales como numéricas. Los defectos superficiales en los alambres de pretensado no se presentan de manera aislada si no que existe una cierta continuidad en la dirección axial así como un elevado número de defectos. Por este motivo se ha optado por un enfoque estadístico, que es más apropiado que el determinístico. El empleo de modelos estadísticos basados en la teoría de valores extremos ha permitido caracterizar el estado superficial en alambres de 5,2 mm de diámetro. Por otro lado la susceptibilidad del alambre frente a la corrosión bajo tensión ha sido evaluada mediante la realización de una campaña de ensayos de acuerdo con la actual normativa que ha permitido caracterizar estadísticamente su comportamiento. A la vista de los resultados ha sido posible evaluar como los parámetros que definen el estado superficial del alambre pueden determinar la durabilidad de la armadura atendiendo a su resistencia frente a la corrosión bajo tensión, evaluada mediante los ensayos que especifica la normativa. En el caso de las cabezas de anclaje de tendones de pretensado, los defectos se presentan de manera aislada y tienen su origen en marcas, arañazos o picaduras de corrosión que pueden producirse durante el proceso de fabricación, transporte, manipulación o puesta en obra. Dada la naturaleza de los defectos, el enfoque determinístico es más apropiado que el estadístico. La evaluación de la importancia de un defecto en un elemento estructural requiere la estimación de la solicitación local que genera el defecto, que permite conocer si el defecto es crítico o si puede llegar a serlo, si es que progresa con el tiempo (por fatiga, corrosión, una combinación de ambas, etc.). En este trabajo los defectos han sido idealizados como grietas, de manera que el análisis quedara del lado de la seguridad. La evaluación de la solicitación local del defecto ha sido calculada mediante el empleo de modelos de elementos finitos de la cabeza de anclaje que simulan las condiciones de trabajo reales de la cabeza de anclaje durante su vida útil. A partir de estos modelos numéricos se ha analizado la influencia en la carga de rotura del anclaje de diversos factores como la geometría del anclaje, las condiciones del apoyo, el material del anclaje, el tamaño del defecto su forma y su posición. Los resultados del análisis numérico han sido contrastados satisfactoriamente mediante la realización de una campaña experimental de modelos a escala de cabezas de anclaje de Polimetil-metacrilato en los que artificialmente se han introducido defectos de diversos tamaños y en distintas posiciones. ABSTRACT Most of the prestressed concrete structures built in the last 50 years have demonstrated an excellent durability when they are constructed in accordance with the rules of good design, detailing and execution. This is particularly true with respect to the feared stress corrosion cracking, which is typical of high strength prestressing steel wires. Less attention, however, has been paid to the stress corrosion cracking susceptibility of anchorages for steel tendons for prestressing concrete, probably due to the low number of reported failure cases. Damage tolerance and fracture mechanics concepts in civil engineering structures have recently started to be incorporated in some design and calculation rules for metallic structures, however it is still far from being assimilated and used by civil engineers in their calculations on a regular basis. This limited knowledge of the damage tolerance basis could lead to significant repair and maintenance costs. This work deals with the applicability of fracture mechanics and damage tolerance concepts to the components of prestressed systems, which are used in civil engineering. Such concepts have been applied to assess the susceptibility of the prestressing steel wires to stress corrosion cracking and the reduction of load bearing capability of anchorage devices due to the presence of defects. For this purpose a combination of experimental work and numerical techniques have been performed. Surface defects in prestressing steel wires are not shown alone, though a certain degree of continuity in the axial direction exist. A significant number of such defects is also observed. Hence a statistical approach was used, which is assumed to be more appropriate than the deterministic approach. The use of statistical methods based in extreme value theories has allowed the characterising of the surface condition of 5.2 mm-diameter wires. On the other hand the stress corrosion cracking susceptibility of the wire has been assessed by means of an experimental testing program in line with the current regulations, which has allowed statistical characterisasion of their performances against stress corrosion cracking. In the light of the test results, it has been possible to evaluate how the surface condition parameters could determine the durability of the active metal armour regarding to its resistance against stress corrosion cracking assessed by means of the current testing regulations. In the case of anchorage devices for steel tendons for prestressing concrete, the damage is presented as point defects originating from dents, scratches or corrosion pits that could be produced during the manufacturing proccess, transport, handling, assembly or use. Due to the nature of these defects, in this case the deterministic approach is more appropriate than the statistical approach. The assessment of the relevancy of defect in a structural component requires the computation of the stress intensity factors, which in turn allow the evaluation of whether the size defect is critical or could become critical with the progress of time (due to fatigue, corrosion or a combination of both effects). In this work the damage is idealised as tiny cracks, a conservative hypothesis. The stress intensity factors have been calculated by means of finite element models of the anchorage representing the real working conditions during its service life. These numeric models were used to assess the impact of some factors on the rupture load of the anchorage, such the anchorage geometry, material, support conditions, defect size, shape and its location. The results from the numerical analysis have been succesfully correlated against the results of the experimental testing program of scaled models of the anchorages in poly-methil methacrylate in which artificial damage in several sizes and locations were introduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Under-deck cable-stayed bridges are very effective structural systems for which the strong contribution of the stay cables under live loading allows for the design of very slender decks for persistent and transient loading scenarios. Their behaviour when subjected to seismic excitation is investigated herein and a set of design criteria are presented that relate to the type and arrangement of bearings, the number and configuration of struts, and the transverse distribution of stay cables. The nonlinear behaviour of these bridges when subject to both near-field and far-field accelerograms has been thoroughly investigated through the use of incremental dynamic analyses. An intensity measure that reflects the pertinent contributions to response when several vibration modes are activated was proposed and is shown to be effective for the analysis of this structural type. The under-deck cable-stay system contributes in a very positive manner to reducing the response when the bridges are subject to very strong seismic excitation. For such scenarios, the reduction in the stiffness of the deck because of crack formation, when prestressed concrete decks are used, mobilises the cable system and enhances the overall performance of the system. Sets of natural accelerograms that are compliant with the prescriptions of Eurocode 8 were also applied to propose a set of design criteria for this bridge type in areas prone to earthquakes. Particular attention is given to outlining the optimal strategies for the deployment of bearings

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die grafische Darstellung des Verbundquerschnittes mit einer oberen Betonplatte und einem darunter liegenden Stahlträger war seit seiner Vorstellung in den 1950er Jahren ein Symbol, das weit über die Theorie hinausging und weite Verbreitung in der Praxis des Verbundbrückenbaus fand. Seit den 1970er bzw. 1980er Jahren hat dieses Bild – bedingt durch neue und freiere Formen, Beton und Stahl miteinander zu kombinieren – seine Symbolhaftigkeit verloren. In Deutschland und Spanien wurde der Doppelverbund mit unten liegenden Betonplatten in Bereichen mit negativen Momenten eingeführt, in Frankreich werden Stahlträger auch in vorgespannten Betonquerschnitten eingebettet. Beide Ansätze haben dazu beigetragen, dass in der Gegenwart die Materialien Stahl und Beton im Verbundbau frei miteinander kombiniert werden können. On the development of sections in composite bridges. A comprehensive theory of composite construction was established in Germany by Sattler in 1953. The theoretical image of the composite section with a superior concrete slab and a lower metallic structure was shaped in addition to the analytical resolution. Theory and graphical representation were going to be known together in Europe. This figure was repeated in all theoretical and academic publications, so becoming an authentic icon of the composite section. Its translation to the bridge deck in flexion was obvious: the superior slab defines the tread platform, while the metallic structure was left off-hook at the bottom. Nevertheless, in continuous decks the section is not optimal at all in zones of negative bending moments. But the overcoming of the graphical representation of the theory did not happen immediately. It was produced after a process in which several European countries played an active role and where different mechanisms of technological transference were developed. One approach to this overcoming is the “double composite action”, with a lower concrete slab in areas of a negative bending moment. The first accomplishments, a bridge in Orasje built in 1968 with 134 m span, as well as the publications of the system proposed by Fabrizio de Miranda in 1971 did not extend nor had continuity. Spanish bridges by Fernández Ordoñez and Martínez Calzón used double composite action for the first time in 1979. The German team of Leonhard, Andrä und partners, has used it since the end of the 1980's to solve bridges of great span. Once the technology has been well known thanks to the ASCE International Congress and the Spanish International Meetings organised by the “Colegio de Ingenieros de Caminos”, double composite action has been integrated well into the structural vocabulary everywhere. In France the approach was different. What Michel Virlogeux calls “double floor composite section” was reached as an evolution of prestressed concrete bridges. In an experimental process widely known, the external prestressing allows weight reduction by diminishing the thickness of the concrete webs. The following step, in the 1980's, was the substitution of the webs by metallic elements: stiffened plates, trusses or folded plates. A direct result of this development is the Brass de la Plaine Bridge in the Reunion Island in 2001 with 280 m span. Both approaches have contributed to a freedom of design in composite construction in steel and concrete today.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Residual stresses developed during wire drawing influence the mechanical behavior and durability of steel wires used for prestressed concrete structures, particularly the shape of the stress–strain curve, stress relaxation losses, fatigue life, and environmental cracking susceptibility. The availability of general purpose finite element analysis tools and powerful diffraction techniques (X-rays and neutrons) has made it possible to predict and measure accurately residual stress fields in cold-drawn steel wires. Work carried out in this field in the past decade, shows the prospects and limitations of residual stress measurement, how the stress relaxation losses and environmentally-assisted cracking are correlated with the profile of residual stresses and how the performance of steel wires can be improved by modifying such a stress profile

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La pérdida de tensión por relajación en las armaduras activas afecta de forma importante a las estructuras de hormigón pretensado. Por ello se realizan ensayos de relajación de los alambres y cordones de pretensado tras su fabricación. Después, el material es enrollado y almacenado durante periodos que en ocasiones pueden superar el año de duración. Generalmente se desprecia la influencia que estas operaciones posteriores a la fabricación pueden tener sobre el material. Sin embargo, diversos fabricantes y suministradores han constatado experimentalmente que, en ocasiones, el material almacenado durante un periodo prolongado presenta pérdidas de relajación mayores que inmediatamente tras su fabricación. En este trabajo se realizan ensayos de laboratorio para comprobar la influencia que el radio de enrollamiento y el periodo de almacenamiento tienen sobre las pérdidas de relajación. También se propone un modelo analítico que permite predecir de manera razonablemente aproximada el valor del ensayo de relajación sobre un alambre sometido a un enrollamiento prolongado. Este modelo explica la evolución del perfil de tensiones durante el proceso de enrollamiento- almacenamiento-desenrollamiento, así como la influencia de las tensiones residuales.Stress relaxation losses on active reinforcement have significant impact on prestressed concrete structures. This is why relaxation tests are carried out on prestressing steel wires and strands after being manufactured. Then, these materials are coiled and stored for a long-term period, sometimes in excess of one year. The influence of these operations, carried out after manufacturing, is usually neglected. Nevertheless, some manufacturers and contractors have noticed that, sometimes, when relaxation tests are carried out after a long-term storage, the relaxation losses found are higher than those measured immediately after manufacturing. In this work, lab tests are performed to check the influence of the coiling radius and the period of storage on the relaxation test. In addition to this, an analytical model is presented to predict the results of a relaxation

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En numerosas ocasiones a lo largo de la historia la imaginación de los creadores ha ido por delante de las posibilidades técnicas de cada momento. Así, muchas de estas nuevas ideas han requerido largos periodos de tiempo para materializarse como realidad construida, hasta que el desarrollo tecnológico e industrial hubo alcanzado un grado de madurez suficiente. En el campo de la arquitectura, estas limitaciones técnicas se han ido acotando paulatinamente hasta desembocar en la situación actual en la que cualquier planteamiento formal puede ser representado gráficamente y analizado desde un punto de vista estructural, superádose de este modo la barrera existente históricamente en el tratamiento de las formas. A lo largo del presente tesis doctoral se analiza cómo la formulación del Método de los Elementos Finitos en la década de los cincuenta y las curvas de Bézier en la década de los sesenta del siglo pasado y la posterior generalización de los ordenadores personales y de los programas informáticos asociados (C.A.D. y F.E.M. principalmente) en los estudios de arquitectura e ingeniería a partir de la década de los noventa, posibilitó el desarrollo de cualquier propuesta arquitectónica, por compleja que ésta fuese, provocando una verdadera revolución a nivel formal en el mundo de la arquitectura, especialmente en el campo de la edificación singular o icónica. Se estudia este proceso a través de ocho edificios; cuatro anteriores y otros tantos posteriores a la desaparición de la barrera anteriormente referida, establecida de forma simbólica en la década de los años ochenta del siglo XX: Frontón de Recoletos en Madrid, Edificio Seagram en Nueva York, Habitat ’67 en Montreal, Ópera de Sídney, museo Guggenheim de Bilbao, ampliación del Victoria & Albert Museum en Londres, tanatorio “Meiso no Mori” en Gifu y nueva sede de la CCTV en Pekín. De entre ellos, la Ópera de Sídney, obra del arquitecto danés Jørn Utzon, condensa gran parte de los aspectos relevantes investigados en relación a la influencia que los métodos de representación y análisis estructural ejercen en la concepción y construcción de las obras de arquitectura. Por este motivo y por considerarse un hito de la arquitectura a nivel global se toma como caso de estudio. La idea general del edificio, que data de 1956, se enmarca en una época inmediatamente anterior a la del desarrollo científico y tecnológico anteriormente referido. Esta ausencia de herramientas de diseño disponibles acordes a la complejidad formal de la propuesta planteada condicionó enormente la marcha del proyecto, dilatándose dramáticamente en el tiempo y disparándose su coste hasta el punto de que el propio arquitecto danés fue separado de las obras antes de su conclusión. Además, la solución estructural finalmente construida de las cubiertas dista mucho de la prevista por Utzon inicialmente. Donde él había imaginado unas finas láminas de hormigón flotando sobre el paisaje se materializó una estructura más pesada, formada por costillas pretensadas de hormigón con unas secciones notablemente mayores. La forma también debió ser modificada de modo ostensible respecto a la propuesta inicial. Si este edificio se pretendiese construir en la actualidad, con toda seguridad el curso de los acontecimientos se desarrollaría por senderos muy diferentes. Ante este supuesto, se plantean las siguientes cuestiones: ¿sería posible realizar un análisis estructural de la cubierta laminar planteada por Utzon inicialmente en el concurso con las herramientas disponibles en la actualidad?; ¿sería dicha propuesta viable estructuralmente?. A lo largo de las siguientes páginas se pretende dar respuesta a estas cuestiones, poniendo de relieve el impacto que los ordenadores personales y los programas informáticos asociados han tenido en la manera de concebir y construir edificios. También se han analizado variantes a la solución laminar planteada en la fase de concurso, a través de las cuales, tratando en la medida de lo posible de ajustarse a las sugerencias que Ove Arup y su equipo realizaron a Jørn Utzon a lo largo del dilatado proceso de proyecto, mejorar el comportamiento general de la estructura del edificio. Por último, se ha pretendido partir de cero y plantear, desde una perspectiva contemporánea, posibles enfoques metodológicos aplicables a la búsqueda de soluciones estructurales compatibles con la forma propuesta originalmente por Utzon para las cubiertas de la Ópera de Sídney y que nunca llegó a ser construida (ni analizada), considerando para ello los medios tecnológicos, científicos e industriales disponibles en la actualidad. Abstract On numerous occasions throughout history the imagination of creators has gone well beyond of the technical possibilities of their time. Many new ideas have required a long period to materialize, until the technological and industrial development had time to catch up. In the architecture field, these technical limitations have gradually tightened leading to the current situation in which any formal approach can be represented and analyzed from a structural point of view, thus concluding that the structural analysis and the graphical representation’s barrier in the development of architectural projects has dissappeared. Throughout the following pages it is examined how the development of the Finite Element Method in the fifties and the Bezier curves in the sixties of the last century and the subsequent spread of personal computers and specialized software in the architectural and engineering offices from the nineties, enabled the development of any architectural proposal independently of its complexity. This has caused a revolution at a formal level in architecture, especially in the field of iconic building. This process is analyzed through eight buildings, four of them before and another four after the disappearance of the above mentioned barrier, roughly established in the eighties of the last century: Fronton Recoletos in Madrid, Seagram Building in New York Habitat '67 in Montreal, Sydney Opera House, Guggenheim Museum Bilbao, Victoria & Albert Museum extension in London, Crematorium “Meiso no Mori” in Gifu and the new CCTV headquarters in Beijing. Among them, the Sydney Opera House, designed by Danish architect Jørn Utzon, condenses many of the main aspects previously investigated regarding the impact of representation methods and structural analysis on the design and construction of architectural projects. For this reason and also because it is considered a global architecture milestone, it is selected as a case study. The building’s general idea, which dates from 1956, is framed at a time immediately preceding the above mentioned scientific and technological development. This lack of available design tools in accordance with the proposal’s formal complexity conditioned enormously the project’s progress, leading to a dramatic delay and multiplying the final budget disproportionately to the point that the Danish architect himself was separated from the works before completion. Furthermore, the built structure differs dramatically from the architect’s initial vision. Where Utzon saw a thin concrete shell floating over the landscape a heavier structure was built, consisting of prestressed concrete ribs with a significantly greater size. The geometry also had to be modified. If this building were to built today, the course of events surely would walk very different paths. Given this assumption, a number of questions could then be formulated: Would it be possible to perform a structural analysis of Utzon’s initially proposed competition-free-ways roof’s geometry with the tools available nowadays?; Would this proposal be structurally feasable?. Throughout the following pages it is intended to clarify this issues, highlighting personal computers and associated software’s impact in building design and construction procedures, especially in the field of iconic building. Variants have also been analyzed for the laminar solution proposed in the competition phase, through which, trying as far as possible to comply with the suggestions that Ove Arup and his team did to Jørn Utzon along the lengthy process project, improving the overall performance of the building structure. Finally, we have started from scratch and analyzed, from a contemporary perspective, possible structural solutions compatible with Utzon’s Opera House’s original geometry and vision –proposal that was never built (nor even analyzed)-, taking into consideration the technological, scientific and industrial means currently available.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las piezas pretensadas de hormigón presentan zonas muy solicitadas correspondientes a la zona de transferencia. En muchos casos se ha detectado figuración en tales zonas cuyo origen está ligado a la transferencia de la fuerza de pretensado, pudiendo llegar a causar el rechazo de la pieza. En el caso de las piezas prefabricadas con armaduras pretesas adherentes, no siempre es posible disponer armado transversal para controlar esta fisuración, ya sea por el proceso constructivo, ya sea por disponer en general de secciones transversales muy optimizadas. Recientemente se desarrolló una nueva tipología de piezas de hormigón prefabricado para forjados unidireccionales pretensadas con armadura activa pretesa y sin armadura transversal. La tipología se asimila a una sección en PI invertida, con alas de gran envergadura en comparación con el ancho de nervio, y armadura activa distribuida en las alas. Este diseño parece propenso a la aparición de fisuración en el momento de la transferencia del pretensado. Así, se han producido fallos de carácter frágil: colapso de piezas ya colocadas en obra, separándose la losa inferior de los nervios y cayendo sobre el piso. Las herramientas de análisis usuales han resultado inútiles al aplicarse a la investigación de esta patología. Para afrontar el estudio de los problemas detectados en la tipología, se ha analizado el fenómeno de las tensiones de tracción en la zona de transferencia, usualmente denominadas exfoliación y estallido, así como los métodos de análisis aplicables a elementos pretesos sin armadura transversal. En algunas ocasiones se trata del resultado de trabajos desarrollados para piezas postesadas, o para calcular cuantías de armadura transversal, adaptados a posteriori. También existen métodos desarrollados específicamente para piezas pretesas sin armadura transversal. Junto a los factores considerados en los métodos existentes se han localizado otros, no tenidos en cuenta habitualmente, pero que pueden ser determinantes en piezas no convencionales, como son: la existencia de pretensado superior e inferior, la falta de simetría de la sección transversal, el ancho variable de las piezas, una relación entre el ancho del ala y el espesor de los nervios elevada, la distribución transversal del pretensado en relación al ancho variable. Además, la mayoría de los métodos se han basado en simplificaciones bidimensionales. Para tener en cuenta la influencia de estos factores, se han modelizado piezas en las que varían tanto la geometría de la sección transversal y la cuantía de pretensado, como la ley de adherencia o la distribución de armadura activa en la sección. Estos modelos se han analizado mediante el método de elementos finitos, efectuándose u análisis elástico lineal tridimensional. En general, los métodos existentes no han predicho adecuadamente las tensiones obtenidas mediante elementos finitos. Sobre los resultados obtenidos por elementos finitos se ha desarrollado un ajuste experimental, que presentan un alto grado de correlación y de significación, así como una reducida dispersión y error relativo. En consecuencia, se propone un método de obtención de la tensión máxima de exfoliación, consistente en varias ecuaciones, que tienen en cuenta las peculiaridades de la configuración de las piezas citadas y permiten considerar cualquier ley de adherencia, manteniendo la coherencia con la longitud de transmisión. Las ecuaciones se emplean para la obtención de la tensión máxima de exfoliación en piezas de la tipología estudiada cuya armadura activa se sitúe fuera del núcleo central de la sección transversal. Respecto al estallido, se propone una modificación de los métodos existentes que, comparado con los resultados del análisis por elementos finitos, mejora el valor medio y la dispersión a valores admisibles y del lado de la seguridad. El método considera la geometría de la sección y la distribución del pretensado en la losa inferior. Finalmente, se ofrecen estrategias de diseño para piezas de la tipología o semejantes. End zones of prestressed concrete members are highly stressed. Cracking have often appeared at end zone, and its beginning is related to prestress release. Some members become rejected because of these cracks. Sometimes it is not possible having transverse reinforcement in order to control cracking, when referring to pretensioned precast members. The reason may be the construction process or highly optimized crosssections. A new typology of precast concrete members designed for one-way composite floors was recently developed. The members, without transverse reinforcement, are prestressed with pretensioned wires or strands. This typology is similar to an inverted TT slab, with a large flange related to the web thickness and prestressing reinforcement spread across the flange. This design is highly susceptible to appear cracking at prestress release. Therefore, brittle failures have been reported: fail of slabs laid in place on a construction site, resulting in the separation of the flange from the webs,, and the subsequent fall on the lower floor. Usual analytical methods have been useless to study the failure. End zone tensile stresses have been analysed to study the detected typology problems. These tensile stresses are usually called spalling and bursting (also called splitting in the U.S.). Analysis methods applicable to pretensioned members without transverse reinforcement have been analysed too. Some methods were originally developed for postensioned concrete or for obtaining the amount of transverse reinforcement. In addition, there are methods developed specifically for pretensioned members without transverse reinforcement. Some factors, frequently ignored, have been found, such as lower and upper prestress, lack of symmetry in the cross section, variable width, a high ratio between flange width and web thickness or prestressing reinforcement location related to variable width. They can play a decisive role in non-conventional members. In addition, most methods are based on 2D simplifications. Finite Element modelling has been conducted in order to consider the influence of these factors. A linear 3D approach has been used. The modelled members vary according to cross section geometry, bond behaviour, or prestressing reinforcement location. In general, the obtained tensile stresses don’t agree with existing methods. An experimental adjustment has been conducted on the obtained results, with a high correlation ratio and significance level as well as a low dispersion and relative error. Therefore, a method to obtain the maximum spalling stress is proposed. The proposal consists on some equations that consider the special features of the typology and bond behaviour. Consistency between transmission length and bond behaviour is considered too. The equations are used to calculate maximum spalling stress for the studied typology members whose prestressing reinforcement is located out of the core of the cross section. In relation to bursting, a modification of existing methods is proposed. Compared to finite element results, the proposal improves mean value and dispersion, whose ranges are considered acceptable and secure. The method takes into account cross section geometry and location of prestressing reinforcement across the lower flange. Finally, strategies to design members of this typology or similar are proposed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las exigencias de calidad, tanto en el ámbito de la rehabilitación como en el de las obras de nueva planta, obligan a evitar la fisuración de la tabiquería. Una de sus principales causas es la deformación excesiva de los forjados. Aunque en la mayoría de los casos no tiene efectos estructurales sino solamente estéticos, es necesario tomar precauciones para evitar la fisuración, pues es una de las patologías más frecuentes y en muchos casos motivo de reclamación de los usuarios. El aumento del consumo de los paneles de placa de yeso laminado y lana de roca para la realización de tabiquerías, justifica la necesidad de ahondar en el conocimiento del comportamiento y del mecanismo de fisuración de este material, pues hasta la fecha no se ha encontrado ningún trabajo especificamente dedicado al estudio del comportamiento en fractura de paneles sandwich de placa de yeso laminado y lana de roca en su plano. A la hora de abordar el estudio del comportamiento en fractura del material objeto de esta tesis, es preciso tener en cuenta que se trata de un material compuesto y, como tal, sus propiedades mecánicas y resistentes dependen en gran medida de las de sus componentes. Por tanto, para poder explicar el comportamiento en fractura del panel sandwich, habrá que estudiar también el de sus componentes. Por otro lado, se considera también muy útil disponer de una herramienta de calculo para la simulación de la fractura de paneles sandwich que sea predictiva. Este modelo hará posible facilitar el diseño de tabiquerías que no se fisure con este material, al poder relacionar las flechas que pueden tomar los forjados con su potencial fisuración. Para contrastar y validar un modelo de este tipo, es necesario disponer de suficientes datos experimentales del comportamiento en fractura del panel sandwich de placa de yeso laminado y lana de roca, que se puedan simular numericamente con el mismo. A partir de lo anteriormente expuesto se plantea, en primer lugar, una campaña experimental con el fin de obtener los parámetros necesarios para caracterizar el comportamiento en fractura de los paneles sandwich y sus componentes: placa de yeso laminado y lana de roca, estudiando también, su comportamiento en fractura en Modo Mixto, y el efecto del tamaño en los parámetros del panel. Por otro lado se propone un modelo de cálculo para la simulación de la fractura en Modo Mixto de paneles sandwich de placa de yeso laminado y lana de roca, comprobando la validez del modelo numérico a partir de los resultados experimentales obtenidos en la campaña de ensayos. Finalmente, se aplica el modelo para estudiar la fisuración de tabiquería realizada con el panel sandwich producida por la deformación de forjados unidireccionales realizados con viguetas de hormigón y bovedilla cerámica, por ser esta tipología la más usual en obras de edificación de viviendas. The quality requirements in terms of rehabilitation and new Works, force to prevent cracking on partitions and one of the main causes is the excessive deformation of the floor. In most of the cases, there are any structural damages, only aesthetic effects, but it is necessary to take precautions to avoid cracking because it is one of the most common diseases and in addition is the main reason of user’s complaints. The increased consumption of plasterboard panels and mineral wool used to build partitions, justifies the need to develop a deeper understanding of the cracking behaviour and mechanism, because by now, any specifically work dedicated to the study of fractures behaviour of sandwich plasterboard panels and rock wool has been found. When approaching the study of the fracture behaviour of the material it must bear in mind that we are referring to a composite material and as such, its mechanical and strength properties depend heavily on its components. Therefore, to explain the fracture behaviour of sandwich panels its components must be studied as well. On the other hand, it is also considered very useful to have a calculation tool to simulate the more likely fractures of the sandwich panel in order to predict it. This model used to perform simulations will enable the design of partitions built with these materials without cracks because it will relate the deflections in decks with its potential cracking. To contrast and validate this type of model, it is necessary and imperative to have enough experimental data of the sandwich plasterboard and rock wool fractures in order to enable its numerical simulation with it. On the basis of the above, the question arises firstly an experimental campaign in order to obtain the necessary parameters to characterize the cracking behaviour of sandwich panels and its components: plasterboard and rock wool, studying also its cracking behaviour in a mixed mode fracture and the effect of size parameters of the panel. Furthermore, a calculation model to simulate fractures in mixed mode of the sandwich panels made of plasterboard and rock wool is proposed in order to check the validity of the numerical model, based on experimental results obtained from the test campaign. Finally, this model is applied to study cracking on partitions built with sandwich panels resulting from the unidirectional floor’s deformations built with prestressed concrete beams and slab pottery pieces being this typology the most common one on residential buildings works.