17 resultados para Platina, 1421-1481.

em Universidad Politécnica de Madrid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

El análisis cuantitativo de las fases minerales visibles en probetas pulidas mediante un sistema experto y automático representan un eficaz complemento a las técnicas tradicionales de microscopía de reflexión. El Análisis digital de imagen, ADI, en comparación con las técnicas habitualmente usadas de cuantificación (platina integradora), supone un ahorro enorme de tiempo, a la vez que facilita un potentísimo instrumento para el tratamiento estadístico de las medidas que se realizan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing penetration of wind energy into power systems has pushed grid operators to set new requirements for this kind of generating plants in order to keep acceptable and reliable operation of the system. In addition to the low voltage ride through capability, wind farms are required to participate in voltage support, stability enhancement and power quality improvement. This paper presents a solution for wind farms with fixed-speed generators based on the use of STATCOM with braking resistor and additional series impedances, with an adequate control strategy. The focus is put on guaranteeing the grid code compliance when the wind farm faces an extensive series of grid disturbances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente proyecto de fin de carrera tiene por objeto la conexión de dos zonas en crecimiento urbanístico separadas por el río Tormes, a su paso por la localidad de Salamanca. En concreto, estas dos zonas son los barrios de Tejares y Chamberí, situados en la margen izquierda del río Tormes y el barrio de Huerta Otea, en la margen derecha. Dichas zonas se localizan en el oeste de la ciudad de Salamanca. El importante desarrollo urbanístico en la margen derecha del río Tormes, contemplado por el Plan General de Ordenación Urbanística de Salamanca y Planes Parciales, que consiste en la construcción de nuevas zonas residenciales (El Marín I, El Marín II y La Platina), tiene como consecuencia un incremento de la población y surge la necesidad de conectar ambas poblaciones separadas por el río Tormes. En dicha zona, los puentes existentes actualmente sobre el río Tormes son el Puente de la Autovía A‐62 (aguas abajo) y el Puente de la Universidad (aguas arriba), ambos puentes están separados por una distancia en planta de unos 2 km. Entonces la conexión de esta zona urbana queda limitada a los puentes citados, la posibilidad de comunicación es bastante reducida, teniendo en cuenta que en la zona urbana de Salamanca, los puentes existentes sobre el río Tormes están separados entre sí, por una distancia de unos 400 metros de media, para dar acceso a todas las poblaciones colindantes con el río.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is the result of research whose main objective is to analyse different methods used for the prediction of maximum scour depth and scour extension, and for the design of scour protections in offshore wind farms located in shallow water, using medium and large diameter monopile foundations. Physical agents such as waves, currents and wind play a major role in the design of structures like offshore farms. As a result, the study has highlighted the need for introducing experience backed climate monomials such as the dimensionless wave height parameter (H0) and proposes the use of formulations that can express the extent of scour protections as a function of waves in transitional waters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solar radiation is the most important source of renewable energy in the planet; it's important to solar engineers, designers and architects, and it's also fundamental for efficiently determining irrigation water needs and potential yield of crops, among others. Complete and accurate solar radiation data at a specific region are indispensable. For locations where measured values are not available, several models have been developed to estimate solar radiation. The objective of this paper was to calibrate, validate and compare five representative models to predict global solar radiation, adjusting the empirical coefficients to increase the local applicability and to develop a linear model. All models were based on easily available meteorological variables, without sunshine hours as input, and were used to estimate the daily solar radiation at Cañada de Luque (Córdoba, Argentina). As validation, measured and estimated solar radiation data were analyzed using several statistic coefficients. The results showed that all the analyzed models were robust and accurate (R2 and RMSE values between 0.87 to 0.89 and 2.05 to 2.14, respectively), so global radiation can be estimated properly with easily available meteorological variables when only temperature data are available. Hargreaves-Samani, Allen and Bristow-Campbell models could be used with typical values to estimate solar radiation while Samani and Almorox models should be applied with calibrated coefficients. Although a new linear model presented the smallest R2 value (R2 = 0.87), it could be considered useful for its easy application. The daily global solar radiation values produced for these models can be used to estimate missing daily values, when only temperature data are available, and in hydrologic or agricultural applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new methodology to build parametric models to estimate global solar irradiation adjusted to specific on-site characteristics based on the evaluation of variable im- portance. Thus, those variables higly correlated to solar irradiation on a site are implemented in the model and therefore, different models might be proposed under different climates. This methodology is applied in a study case in La Rioja region (northern Spain). A new model is proposed and evaluated on stability and accuracy against a review of twenty-two already exist- ing parametric models based on temperatures and rainfall in seventeen meteorological stations in La Rioja. The methodology of model evaluation is based on bootstrapping, which leads to achieve a high level of confidence in model calibration and validation from short time series (in this case five years, from 2007 to 2011). The model proposed improves the estimates of the other twenty-two models with average mean absolute error (MAE) of 2.195 MJ/m2 day and average confidence interval width (95% C.I., n=100) of 0.261 MJ/m2 day. 41.65% of the daily residuals in the case of SIAR and 20.12% in that of SOS Rioja fall within the uncertainty tolerance of the pyranometers of the two networks (10% and 5%, respectively). Relative differences between measured and estimated irradiation on an annual cumulative basis are below 4.82%. Thus, the proposed model might be useful to estimate annual sums of global solar irradiation, reaching insignificant differences between measurements from pyranometers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intercultural Approaches to Cities and Spaces in Literature, Film, and New Media: a review of new work by Manzanas and Benito and Lopez-Varela and Net

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Offshore wind industry has exponentially grown in the last years. Despite this growth, there are still many uncertainties in this field. This paper analyzes some current uncertainties in the offshore wind market, with the aim of going one step further in the development of this sector. To do this, some already identified uncertainties compromising offshore wind farm structural design have been identified and described in the paper. Examples of these identified uncertainties are the design of the transition piece and the difficulties for the soil properties characterization. Furthermore, this paper deals with other uncertainties not identified yet due to the limited experience in the sector. To do that, current and most used offshore wind standards and recommendations related to the design of foundation and support structures (IEC 61400-1, 2005; IEC 61400-3, 2009; DNV-OS-J101, Design of Offshore Wind Turbine, 2013 and Rules and Guidelines Germanischer Lloyd, WindEnergie, 2005) have been analyzed. These new identified uncertainties are related to the lifetime and return period, loads combination, scour phenomenon and its protection, Morison e Froude Krilov and diffraction regimes, wave theory, different scale and liquefaction. In fact, there are a lot of improvements to make in this field. Some of them are mentioned in this paper, but the future experience in the matter will make it possible to detect more issues to be solved and improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the last decades, the photovoltaic (PV) modules and their associated architectural materials are increasingly being incorporated into the construction of the building envelope such as façade, roof and skylights in the urban centers. This paper analyzes the-state-of-the-art of the PV elements and construction materials which are advertised as BIPV-products at the most important companies in the world. For this purpose 136 companies and 445 PV elements have been investigated and analyzed from a technical and architectural point of view. Also, the study has been divided into two main groups according to industry which producing the product: BIPV-Modules, which comes from the PV modules manufacturers and consist of standard PV-modules with some variations in its aesthetic features, support or dimensions; and PV-Constructions Elements, which consist of conventional constructive elements with architectural features intentionally manufactured for photovoltaic integration. In advance for conclusions, the solar tile is the most common PV-constructions element, the Si-crystalline is the most widely used PV technology, and the BIPV-urban furniture is the fastest growing market experienced in recent years. However, it is clear the absences of innovative elements which meet at the same time both the constructive purpose as the quality standards of PV technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Linear Fresnel collectors still present a large margin to improve efficiency. Solar fields of this kind installed until current time, both prototypes and commercial plants, are designed with widths and shifts of mirrors that are constant across the solar field. However, the physical processes that limit the width of the mirrors depend on their relative locations to the receiver; the same applies to shading and blocking effects, that oblige to have a minimum shift between mirrors. In this work such phenomena are studied analytically in order to obtain a coherent design, able to improve the efficiency with no increase in cost. A ray tracing simulation along one year has been carried out for a given design, obtaining a moderate increase in radiation collecting efficiency in comparison to conventional designs. Moreover, this analytic theory can guide future designs aiming at fully optimizing linear Fresnel collectors' performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solar radiation estimates with clear sky models require estimations of aerosol data. The low spatial resolution of current aerosol datasets, with their remarkable drift from measured data, poses a problem in solar resource estimation. This paper proposes a new downscaling methodology by combining support vector machines for regression (SVR) and kriging with external drift, with data from the MACC reanalysis datasets and temperature and rainfall measurements from 213 meteorological stations in continental Spain. The SVR technique was proven efficient in aerosol variable modeling. The Linke turbidity factor (TL) and the aerosol optical depth at 550 nm (AOD 550) estimated with SVR generated significantly lower errors in AERONET positions than MACC reanalysis estimates. The TL was estimated with relative mean absolute error (rMAE) of 10.2% (compared with AERONET), against the MACC rMAE of 18.5%. A similar behavior was seen with AOD 550, estimated with rMAE of 8.6% (compared with AERONET), against the MACC rMAE of 65.6%. Kriging using MACC data as an external drift was found useful in generating high resolution maps (0.05° × 0.05°) of both aerosol variables. We created high resolution maps of aerosol variables in continental Spain for the year 2008. The proposed methodology was proven to be a valuable tool to create high resolution maps of aerosol variables (TL and AOD 550). This methodology shows meaningful improvements when compared with estimated available databases and therefore, leads to more accurate solar resource estimations. This methodology could also be applied to the prediction of other atmospheric variables, whose datasets are of low resolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper the power-frequency control of hydropower plants with long penstocks is addressed. In such configuration the effects of pressure waves cannot be neglected and therefore commonly used criteria for adjustment of PID governors would not be appropriate. A second-order Π model of the turbine-penstock based on a lumped parameter approach is considered. A correction factor is introduced in order to approximate the model frequency response to the continuous case in the frequency interval of interest. Using this model, several criteria are analysed for adjusting the PI governor of a hydropower plant operating in an isolated system. Practical criteria for adjusting the PI governor are given. The results are applied to a real case of a small island where the objective is to achieve a generation 100% renewable (wind and hydro). Frequency control is supposed to be provided exclusively by the hydropower plant. It is verified that the usual criterion for tuning the PI controller of isolated hydro plants gives poor results. However, with the new proposed adjustment, the time response is considerably improved

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pumped storage hydro plants (PSHP) can provide adequate energy storage and frequency regulation capacities in isolated power systems having significant renewable energy resources. Due to its high wind and solar potential, several plans have been developed for La Palma Island in the Canary archipelago, aimed at increasing the penetration of these energy sources. In this paper, the performance of the frequency control of La Palma power system is assessed, when the demand is supplied by the available wind and solar generation with the support of a PSHP which has been predesigned for this purpose. The frequency regulation is provided exclusively by the PSHP. Due to topographic and environmental constraints, this plant has a long tail-race tunnel without a surge tank. In this configuration, the effects of pressure waves cannot be neglected and, therefore, usual recommendations for PID governor tuning provide poor performance. A PI governor tuning criterion is proposed for the hydro plant and compared with other criteria according to several performance indices. Several scenarios considering solar and wind energy penetration have been simulated to check the plant response using the proposed criterion. This tuning of the PI governor maintains La Palma system frequency within grid code requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A proposal for an extended formulation of the power coefficient of a wind turbine is presented. This new formulation is a generalization of the Betz–Lanchester expression for the power coefficient as function of the axial deceleration of the wind speed provoked by the wind turbine in operation. The extended power coefficient takes into account the benefits of the power produced and the cost associated to the production of this energy. By the simple model proposed is evidenced that the purely energetic optimum operation condition giving rise to the Betz–Lanchester limit (maximum energy produced) does not coincide with the global optimum operational condition (maximum benefit generated) if cost of energy and degradation of the wind turbine during operation is considered. The new extended power coefficient is a general parameter useful to define global optimum operation conditions for wind turbines, considering not only the energy production but also the maintenance cost and the economic cost associated to the life reduction of the machine.