9 resultados para Plants, Protection of
em Universidad Politécnica de Madrid
Resumo:
Final lenses in laser fusion plants. Challenges for the protection of the final lenses. Plasmonic nanoparticles. Radiation resistance
Resumo:
The HiPER project, phase 4a, is evolving. In this study we present the progress made in the field of neutronics and radiological protection for an integrated design of the facility. In the current model, we take into account the optical systems inside the target bay, as well as the remote handling requirements and related infrastructure, together with different shields. The last reference irradiation scenario, consisting of 20 MJ of neutron yields, 5 yields per burst, one burst every week and 30 years of expected lifetime is considered for this study. We have performed a characterization of the dose rates behavior in the facility, both during operation and between bursts. The dose rates are computed for workers, regarding to maintenance and handling, and also for optical systems, regarding to damage. Furthermore, we have performed a waste management assessment of all the components inside the target bay. Results indicate that remote maintenance is mandatory in some areas. The small beam penetrations in the shields are responsible for some high doses in some specific locations. With regards to optics, the residual doses are as high as prompt doses. It is found that the whole target bay may be fully managed as a waste in 30 years by recycling and/or clearance, with no need for burial.
Resumo:
Analysis of the "European Charter on General Principles for Protection of the Environment and Sustainable Development" The Council of Europe Document CO-DBP (2003) 2
Resumo:
Análisis de la atenuación del oleaje por un carguero funcionando como dique flotante y aplicación a dos casos de protección portuaria y costera. The effectiveness of a bulk carrier working as a detached floating breakwater to protect a stretch of coast and form salients or tombolos is assessed in this paper. Experiments were conducted in the Madrid CEDEX facilities in a 30 m long, 3 m wide, 1/150 scale flume. The bulk carrier ship is 205 m long, 29 m wide and 18 m in height with a draught of 13 m, and has been subjected to irregular waves with significant heights from 2 m to 4 m and peak periods from 6 s to 12 s at a depth of 15 m, all prototype dimensions. Three probes were placed between the wave paddle and the ship to record incident and reflected waves and four probes were placed between the ship and the coastline to measure the transmitted waves. Transmission, reflection and dissipation coefficients (Ct, Cr, Cd) were calculated to determine wave attenuation. Results show good shelter in the lee of the ship with values of Ct under 0.5 for peak periods from 6 s to 11 s. In addition, forces on the mooring chains were measured showing maximum values of about 2000 tons at a 10 speak period. Finally, two analytical models were used to determine the shoreline’s response to the ship’s protection and to assess the possible forming of salients or tombolos. According to the results, salients - but not tombolos - are formed in all tests.
Resumo:
Ozone (O3) phytotoxicity has been reported on a wide range of plant species. However, scarce information has been provided regarding the sensitivity of semi-natural grassland species, especially those from dehesa Mediterranean grasslands, in spite of their great biological diversity and the high O3 levels recorded in the region. A screening study was carried out in open-top chambers (OTCs) to assess the O3-sensitivity of representative therophytes of these ecosystems based on the response of selected growth-related parameters. Three O3 treatments and 3 OTCs per treatment were used. Legume species were very sensitive to O3, because 78% of the tested species showed detrimental effects on their total biomass relative growth rate (RGR) following their exposure to O3. The Trifolium genus was particularly sensitive showing O3-induced adverse effects on most of the assessed parameters. Gramineae plants were less sensitive than Leguminosae species because detrimental effects on total biomass RGR were only observed in 14% of the assessed species. No relationship was found between relative growth rates when growing in clean air and O3 susceptibility. The implications of these effects on the performance of dehesa acidic grasslands and on the definition of ozone critical levels for the protection of semi-natural vegetation are discussed.
Resumo:
The figure of protection "micro-reserves" was created in the Region of Valencia (ANONYMOUS, 1994) with the aim of protecting endangered plant species. This is one of the areas of greatest floristic richness and uniqueness of the western Mediterranean. In this area rare, endemic or threatened vascular flora has a peculiar distribution: they appear to form small fragments spread over the entire region (LAGUNA, 1994; LAGUNA, 2001) The protection of every these small populations of great scientific value has significant challenges. It doesn´t try to protect every species that set out in Annex IV of the by then existing Law 4 / 1989 (repealed in 2007), or to protect to the most ecological level with the creation of Natural Protected Area but an intermediate level: the plant community of small size. According to the decree: “as Micro-Reserve will be declared the natural parcels of land under 20 hectares that contain a high concentration of rare plants, endemic, threatened or of high scientific interest” (ANONYMOUS, 1994) . Of course, the statement of an area as micro-reserve carries certain prohibitions that are harmful to the vegetal community
Resumo:
Phytoextraction is an environmental-friendly and cost-effective technology that uses metal hyperaccumulator plants to remove heavy metals from soils. The metals are absorbed by the roots, transported and accumulated in the aerial parts of the plants, which can be harvested and eliminated. The aim of this work was to study some hyperaccumulator species that could be useful to decontaminate mine soils and also to investigate the bioavailability and uptake of these metals by plants with the addition of organic amendments. Pot experiments were performed with soil samples collected from two mining areas in the north of Madrid, where there was an intense mining activity more than 50 years ago. Three species (Thlaspi arvense, Brassica juncea and Atriplex halimus) were grown under controlled conditions in pots filled with contaminated soils mixed with 0 Mg, 30 Mg and 60 Mg per hectare of two different organic amendments: a commercial compost made of pine bark, peat and wood fiber and other made of horse and sheep manure and wood fiber. Plants were harvested at the end of their crop cycle and were digested in order to measure metal concentration (Zn, Cu and Cd) in roots and shoots. Highest plant metal concentration was observed in pots treated with pine bark amendment and with pure soil due to an increase in metal bioavailability with decreasing pH. Also in those treatments the total plant biomass was lower, even some plants could not germinate. On the contrary, there was a lower metal concentration in plant tissues of pots with manure because its higher pH whereas plant growth was significantly larger so there was an incresing amount of metals removed from soil by plants. Comparing the three species results indicate a higher total metal uptake in A. halimus than B. juncea and T. arvense. In conclusion, results show that pH affects metal bioavailability and uptake by hyperaccumulator plants. Addition of organic amendments could be a successful technique for stabilization of metals in contaminated soils.
Resumo:
The aim of this work was to study some hyperaccumulator species that could be useful to decontaminate mine soils and also to investigate the bioavailability and uptake of these metals by plants with the addition of organic amendments. Pot experiments were performed with soil samples collected from two mining areas in the north of Madrid, where there was an intense mining activity more than 50 years ago. Three species (Thlaspi arvense, Brassica juncea and Atriplex halimus) were grown under controlled conditions in pots filled with contaminated soils mixed with 0 Mg, 30 Mg and 60 Mg per hectare of two different organic amendments: a commercial compost made of pine bark, peat and wood fiber and other made of horse and sheep manure and wood fiber. Plants were harvested at the end of their crop cycle and were digested in order to measure metal concentration (Zn, Cu and Cd) in roots and shoots. Highest plant metal concentration was observed in pots treated with pine bark amendment and with pure soil due to an increase in metal bioavailability with decreasing pH. Also in those treatments the total plant biomass was lower, even some plants could not germinate. On the contrary, there was a lower metal concentration in plant tissues of pots with manure because its higher pH whereas plant growth was significantly larger so there was an incresing amount of metals removed from soil by plants. Comparing the three species results indicate a higher total metal uptake in A. halimus than B. juncea and T. arvense. In conclusion, results show that pH affects metal bioavailability and uptake by hyperaccumulator plants. Addition of organic amendments could be a successful technique for stabilization of metals in contaminated soils.
Resumo:
Esta tesis doctoral presenta un procedimiento integral de control de calidad en centrales fotovoltaicas, que comprende desde la fase inicial de estimación de las expectativas de producción hasta la vigilancia del funcionamiento de la instalación una vez en operación, y que permite reducir la incertidumbre asociada su comportamiento y aumentar su fiabilidad a largo plazo, optimizando su funcionamiento. La coyuntura de la tecnología fotovoltaica ha evolucionado enormemente en los últimos años, haciendo que las centrales fotovoltaicas sean capaces de producir energía a unos precios totalmente competitivos en relación con otras fuentes de energía. Esto hace que aumente la exigencia sobre el funcionamiento y la fiabilidad de estas instalaciones. Para cumplir con dicha exigencia, es necesaria la adecuación de los procedimientos de control de calidad aplicados, así como el desarrollo de nuevos métodos que deriven en un conocimiento más completo del estado de las centrales, y que permitan mantener la vigilancia sobre las mismas a lo largo del tiempo. Además, los ajustados márgenes de explotación actuales requieren que durante la fase de diseño se disponga de métodos de estimación de la producción que comporten la menor incertidumbre posible. La propuesta de control de calidad presentada en este trabajo parte de protocolos anteriores orientados a la fase de puesta en marcha de una instalación fotovoltaica, y las complementa con métodos aplicables a la fase de operación, prestando especial atención a los principales problemas que aparecen en las centrales a lo largo de su vida útil (puntos calientes, impacto de la suciedad, envejecimiento…). Además, incorpora un protocolo de vigilancia y análisis del funcionamiento de las instalaciones a partir de sus datos de monitorización, que incluye desde la comprobación de la validez de los propios datos registrados hasta la detección y el diagnóstico de fallos, y que permite un conocimiento automatizado y detallado de las plantas. Dicho procedimiento está orientado a facilitar las tareas de operación y mantenimiento, de manera que se garantice una alta disponibilidad de funcionamiento de la instalación. De vuelta a la fase inicial de cálculo de las expectativas de producción, se utilizan los datos registrados en las centrales para llevar a cabo una mejora de los métodos de estimación de la radiación, que es la componente que más incertidumbre añade al proceso de modelado. El desarrollo y la aplicación de este procedimiento de control de calidad se han llevado a cabo en 39 grandes centrales fotovoltaicas, que totalizan una potencia de 250 MW, distribuidas por varios países de Europa y América Latina. ABSTRACT This thesis presents a comprehensive quality control procedure to be applied in photovoltaic plants, which covers from the initial phase of energy production estimation to the monitoring of the installation performance, once it is in operation. This protocol allows reducing the uncertainty associated to the photovoltaic plants behaviour and increases their long term reliability, therefore optimizing their performance. The situation of photovoltaic technology has drastically evolved in recent years, making photovoltaic plants capable of producing energy at fully competitive prices, in relation to other energy sources. This fact increases the requirements on the performance and reliability of these facilities. To meet this demand, it is necessary to adapt the quality control procedures and to develop new methods able to provide a more complete knowledge of the state of health of the plants, and able to maintain surveillance on them over time. In addition, the current meagre margins in which these installations operate require procedures capable of estimating energy production with the lower possible uncertainty during the design phase. The quality control procedure presented in this work starts from previous protocols oriented to the commissioning phase of a photovoltaic system, and complete them with procedures for the operation phase, paying particular attention to the major problems that arise in photovoltaic plants during their lifetime (hot spots, dust impact, ageing...). It also incorporates a protocol to control and analyse the installation performance directly from its monitoring data, which comprises from checking the validity of the recorded data itself to the detection and diagnosis of failures, and which allows an automated and detailed knowledge of the PV plant performance that can be oriented to facilitate the operation and maintenance of the installation, so as to ensure a high operation availability of the system. Back to the initial stage of calculating production expectations, the data recorded in the photovoltaic plants is used to improved methods for estimating the incident irradiation, which is the component that adds more uncertainty to the modelling process. The development and implementation of the presented quality control procedure has been carried out in 39 large photovoltaic plants, with a total power of 250 MW, located in different European and Latin-American countries.