9 resultados para Performance of construction materials

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Insulating materials in buildings are one of the main factors that should be taken into account when talking about sustainability since with a correct application it could imply important savings for the citizens. In the course of its life, a building requires a series of supplies to perform the duties it has been built for, generating an impact on the environment. The selection of one material or another will establish partly the global environmental impact of the building. Choosing the right insulating material will determine the building's general degree of sustainability, both in its heating savings (energy consumption) and in the environmental impacts caused by its LCA (greenhouse gas emissions). Therefore, we propose to establish guidelines to characterize the insulating material with a better environmental performance in all the stages of its life cycle, taking into account the construction system, the use of the building and its location.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional teaching methods used for training civil engineers are currently being called into question as a result of the new knowledge and skills now required by the labor market. In addition, the European Higher Education Area is requesting that students be given a greater say in their learning. In the subject called Construction and Building Materials at the Civil Engineering School of the Universidad Politécnica de Madrid, a path was set three academic years ago to lead to an improvement in traditional teaching by introducing active methodologies. The innovations are based on cooperative learning, new technologies, and continuous assessment. The writers’ proposal is to offer their experience as a contribution to the debate on how students can be encouraged to acquire the skills currently demanded from a civil engineer, though not overlooking solid, top-quality training. From the outcomes obtained, it can be concluded that using new teaching techniques to supplement a traditional approach provides more opportunities for students to learn while boosting their motivation. In our case, the introduction of these changes has resulted in an increased pass rate of 29% on average, when such a figure is considered in the light of the mean value of passes during the last decade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El propósito de esta tesis es estudiar la aproximación a los fenómenos de transporte térmico en edificación acristalada a través de sus réplicas a escala. La tarea central de esta tesis es, por lo tanto, la comparación del comportamiento térmico de modelos a escala con el correspondiente comportamiento térmico del prototipo a escala real. Los datos principales de comparación entre modelo y prototipo serán las temperaturas. En el primer capítulo del Estado del Arte de esta tesis se hará un recorrido histórico por los usos de los modelos a escala desde la antigüedad hasta nuestro días. Dentro de éste, en el Estado de la Técnica, se expondrán los beneficios que tiene su empleo y las dificultades que conllevan. A continuación, en el Estado de la Investigación de los modelos a escala, se analizarán artículos científicos y tesis. Precisamente, nos centraremos en aquellos modelos a escala que son funcionales. Los modelos a escala funcionales son modelos a escala que replican, además, una o algunas de las funciones de sus prototipos. Los modelos a escala pueden estar distorsionados o no. Los modelos a escala distorsionados son aquellos con cambios intencionados en las dimensiones o en las características constructivas para la obtención de una respuesta específica por ejemplo, replicar el comportamiento térmico. Los modelos a escala sin distorsión, o no distorsionados, son aquellos que mantienen, en la medida de lo posible, las proporciones dimensionales y características constructivas de sus prototipos de referencia. Estos modelos a escala funcionales y no distorsionados son especialmente útiles para los arquitectos ya que permiten a la vez ser empleados como elementos funcionales de análisis y como elementos de toma de decisiones en el diseño constructivo. A pesar de su versatilidad, en general, se observará que se han utilizado muy poco estos modelos a escala funcionales sin distorsión para el estudio del comportamiento térmico de la edificación. Posteriormente, se expondrán las teorías para el análisis de los datos térmicos recogidos de los modelos a escala y su aplicabilidad a los correspondientes prototipos a escala real. Se explicarán los experimentos llevados a cabo, tanto en laboratorio como a intemperie. Se han realizado experimentos con modelos sencillos cúbicos a diferentes escalas y sometidos a las mismas condiciones ambientales. De estos modelos sencillos hemos dado el salto a un modelo reducido de una edificación acristalada relativamente sencilla. Los experimentos consisten en ensayos simultáneos a intemperie del prototipo a escala real y su modelo reducido del Taller de Prototipos de la Escuela Técnica Superior de Arquitectura de Madrid (ETSAM). Para el análisis de los datos experimentales hemos aplicado las teorías conocidas, tanto comparaciones directas como el empleo del análisis dimensional. Finalmente, las simulaciones nos permiten comparaciones flexibles con los datos experimentales, por ese motivo, hemos utilizado tanto programas comerciales como un algoritmo de simulación desarrollado ad hoc para esta investigación. Finalmente, exponemos la discusión y las conclusiones de esta investigación. Abstract The purpose of this thesis is to study the approximation to phenomena of heat transfer in glazed buildings through their scale replicas. The central task of this thesis is, therefore, the comparison of the thermal performance of scale models without distortion with the corresponding thermal performance of their full-scale prototypes. Indoor air temperatures of the scale model and the corresponding prototype are the data to be compared. In the first chapter on the State of the Art, it will be shown a broad vision, consisting of a historic review of uses of scale models, from antiquity to our days. In the section State of the Technique, the benefits and difficulties associated with their implementation are presented. Additionally, in the section State of the Research, current scientific papers and theses on scale models are reviewed. Specifically, we focus on functional scale models. Functional scale models are scale models that replicate, additionally, one or some of the functions of their corresponding prototypes. Scale models can be distorted or not. Scale models with distortion are considered scale models with intentional changes, on one hand, in dimensions scaled unevenly and, on the other hand, in constructive characteristics or materials, in order to get a specific performance for instance, a specific thermal performance. Consequently, scale models without distortion, or undistorted scale models scaled evenly, are those replicating, to the extent possible, without distortion, the dimensional proportions and constructive configurations of their prototypes of reference. These undistorted and functional scale models are especially useful for architects because they can be used, simultaneously, as functional elements of analysis and as decision-making elements during the design. Although they are versatile, in general, it is remarkable that these types of models are used very little for the study of the thermal performance of buildings. Subsequently, the theories related to the analysis of the experimental thermal data collected from the scale models and their applicability to the corresponding full-scale prototypes, will be explained. Thereafter, the experiments in laboratory and at outdoor conditions are detailed. Firstly, experiments carried out with simple cube models at different scales are explained. The prototype larger in size and the corresponding undistorted scale model have been subjected to same environmental conditions in every experimental test. Secondly, a step forward is taken carrying out some simultaneous experimental tests of an undistorted scale model, replica of a relatively simple lightweight and glazed building construction. This experiment consists of monitoring the undistorted scale model of the prototype workshop located in the School of Architecture (ETSAM) of the Technical University of Madrid (UPM). For the analysis of experimental data, known related theories and resources are applied, such as, direct comparisons, statistical analyses, Dimensional Analysis and last, but not least important, simulations. Simulations allow us, specifically, flexible comparisons with experimental data. Here, apart the use of the simulation software EnergyPlus, a simulation algorithm is developed ad hoc for this research. Finally, the discussion and conclusions of this research are exposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The European construction industry is supposed to consume the 40% of the natural European resources and to generate the 40% of the European solid waste. Conscious of the great damage being suffered by the environment because of construction activity, this work tries to provide the building actors with a new tool to improve the current situation. The tool proposed is a model for the comprehensive evaluation of construction products by determining their environmental level. In this research, the environmental level of a construction product has been defined as its quality of accomplishing the construction requirements needed by causing the minimum ecological impact in its surrounding environment. This information allows building actors to choose suitable materials for building needs and also for the environment, mainly in the project stage or on the building site, contributing to improve the relationship between buildings and environment. For the assessment of the environmental level of construction products, five indicators have been identified regarding their global environmental impact through the product life cycle: CO2 emissions provoked during their production, volume and toxicity of waste generated on the building site, durability and recycling capacity after their useful life. Therefore, the less environmental impact one construction product produces, the higher environmental level performs. The model has been tested in 30 construction products that include environmental criteria in their description. The results obtained will be discussed in this article. Furthermore, this model can lay down guidelines for the selection of ecoefficient construction products and the design of new eco-competitive and eco-committed ones

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The construction industry, one of the most important ones in the development of a country, generates unavoidable impacts on the environment. The social demand towards greater respect for the environment is a high and general outcry. Therefore, the construction industry needs to reduce the impact it produces. Proper waste management is not enough; we must take a further step in environmental management, where new measures need to be introduced for the prevention at source, such as good practices to promote recycling. Following the amendment of the legal frame applicable to Construction and Demolition Waste (C&D waste), important developments have been incorporated in European and International laws, aiming to promote the culture of reusing and recycling. This change of mindset, that is progressively taking place in society, is allowing for the consideration of C&D waste no longer as an unusable waste, but as a reusable material. The main objective of the work presented in this paper is to enhance C&D waste management systems through the development of preventive measures during the construction process. These measures concern all the agents intervening in the construction process as only the personal implication of all of them can ensure an efficient management of the C&D waste generated. Finally, a model based on preventive measures achieves organizational cohesion between the different stages of the construction process, as well as promoting the conservation of raw materials through the use and waste minimization. All of these in order to achieve a C&D waste management system, whose primary goal is zero waste generation

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because of their remarkable mechanical properties, nanocrystalline metals have been the focus of much research in recent years. Refining their grain size to the nanometer range (<100 nm) effectively reduces their dislocation mobility, thus achieving very high yield strength and surface hardness—as predicted by the Hall–Petch relation—as well as higher strain-rate sensitivity. Recent works have additionally suggested that nanocrystalline metals exhibit an even higher compressive strength under shock loading. However, the increase in strength of these materials is generally accompanied by an important reduction in ductility. As an alternative, efforts have been focused on ultrafine crystals, i.e. polycrystals with a grain size in the range of 500 nm to 1 μm, in which “growth twins” (twins introduced inside the grain before deformation) act as barriers against dislocation movement, thus increasing the strength in a similar way as nanocrystals but without significant loss of ductility. Due to their outstanding mechanical properties, both nanocrystalline and nanotwinned ultrafine crystalline steels appear to be relevant candidates for ballistic protection. The aim of the present work is to compare their ballistic performance against coarse-grained steel, as well as to identify the effect of the hybridization with a carbon fiber–epoxy composite layer. Hybridization is proposed as a way to improve the nanocrystalline brittle properties in a similar way as is done with ceramics in other protection systems. The experimental campaign is finally complemented by numerical simulations to help identify some of the intrinsic deformation mechanisms not observable experimentally. As a conclusion, nanocrystalline and nanotwinned ultrafine crystals show a lower energy absorption than coarse-grained steel under ballistic loading, but under equal impact conditions with no penetration, deformation in the impact direction is smaller by nearly 40%. This a priori surprising difference in the energy absorption is rationalized by the more important local contribution of the deviatoric stress vs. volumetric stress under impact than under uniaxial deformation. Ultimately, the deformation advantage could be exploited in the future for personal protection systems where a small deformation under impact is of key importance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tiny increases in the transmittance of optical materials within a CPV module can have an important impact on the economy of a plant. This is certainly true in systems comprising multi-junction solar cells, whose high performance, based on a balanced photocurrent generation among the series-connected junctions, is very sensitive to spectrum variations. Every efficiency point gained causes not only an increase in the kilowatts hour produced, but a higher benefit on it, since the difference between electricity tariff and Levelized Cost of Electricity (LCOE) rises. This work studies the impact on the LCOE of a plant based on modules comprising PMMA lenses of two different types, standard UV blocking grade which is normally used for outdoor applications at high DNI climate and a specialty stabilized UV-enhanced transmittance acrylic (see Figure 1). Energy production will be compared for these two systems throughout the year at different sites to analyze when (season, time of the day) and where the usage of the enhanced PMMA is justified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The field of optical label free biosensors has become a topic of interest during past years, with devices based on the detection of angular or wavelength shift of optical modes [1]. Common parameters to characterize their performance are the Limit of Detection (LOD, defined as the minimum change of refractive index upon the sensing surface that the device is able to detect, and also BioLOD, which represents the minimum amount of target analyte accurately resolved by the system; with units of concentration (common un its are p pm, ng/ml, or nM). LOD gives a first value to compare different biosensors, and is obtained both theoretically (using photonic calculation tools), and experimentally,covering the sensing area with fluids of different refractive indexes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy storage at low maintenance cost is one of the key challenges for generating electricity from the solar energy. This paper presents the theoretical analysis (verified by CFD) of the night time performance of a recently proposed conceptual system that integrates thermal storage (via phase change materials) and thermophotovoltaics for power generation. These storage integrated solar thermophotovoltaic (SISTPV) systems are attractive owing to their simple design (no moving parts) and modularity compared to conventional Concentrated Solar Power (CSP) technologies. Importantly, the ability of high temperature operation of these systems allows the use of silicon (melting point of 1680 K) as the phase change material (PCM). Silicon's very high latent heat of fusion of 1800 kJ/kg and low cost ($1.70/kg), makes it an ideal heat storage medium enabling for an extremely high storage energy density and low weight modular systems. In this paper, the night time operation of the SISTPV system optimised for steady state is analysed. The results indicate that for any given PCM length, a combination of small taper ratio and large inlet hole-to-absorber area ratio are essential to increase the operation time and the average power produced during the night time. Additionally, the overall results show that there is a trade-off between running time and the average power produced during the night time. Average night time power densities as high as 30 W/cm(2) are possible if the system is designed with a small PCM length (10 cm) to operate just a few hours after sun-set, but running times longer than 72 h (3 days) are possible for larger lengths (50 cm) at the expense of a lower average power density of about 14 W/cm(2). In both cases the steady state system efficiency has been predicted to be about 30%. This makes SISTPV systems to be a versatile solution that can be adapted for operation in a broad range of locations with different climate conditions, even being used off-grid and in space applications.