9 resultados para Pelvic floor dysfunction

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To investigate the effect of pelvic floor muscle training (PFMT) taught in a general exercise class during pregnancy on the prevention of urinary incontinence (UI) in nulliparous continent pregnant women. METHODS: This was a unicenter two armed randomized controlled trial. One hundred sixty-nine women were randomized by a central computer system to an exercise group (EG) (exercise class including PFMT) (n = 73) or a control group (CG) (n = 96). 10.1% loss to follow-up: 10 from EG and 7 from CG. The intervention consisted of 70-75 sessions (22 weeks, three times per week, 55-60 min/session including 10 min of PFMT). The CG received usual care (which included follow up by midwifes including information about PFMT). Questions on prevalence and degree of UI were posed before (week 10-14) and after intervention (week 36-39) using the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form (ICIQ-UI SF). RESULTS: At the end of the intervention, there was a statistically significant difference in favor of the EG. Reported frequency of UI [Never: CG: 54/60.7%, EG: 60/95.2% (P < 0.001)]. Amount of leakage [None: CG: 45/60.7%, EG: 60/95.2% (P < 0.001)]. There was also a statistically significant difference in ICIQ-UI SF Score between groups after the intervention period [CG: 2.7 (SD 4.1), EG: 0.2 (SD 1.2) (P < 0.001)]. The estimated effect size was 0.8. CONCLUSION: PFMT taught in a general exercise class three times per week for at least 22 weeks, without former assessment of ability to perform a correct contraction was effective in primary prevention of UI in primiparous pregnant women.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: Diversos cambios ocurren en el sistema cardiovascular materno durante el embarazo, lo que genera un gran estrés sobre este sistema especialmente durante el tercer trimestre, pudiendo acentuarse en presencia de determinados factores de riesgo. Los objetivos de este estudio fueron, valorar las adaptaciones cardiovasculares producidas por un programa específico de ejercicio físico; su seguridad sobre el sistema cardiovascular materno y los resultados del embarazo; y su eficacia en el control de los factores de riesgo cardiovascular. Material y métodos: El diseño del estudio fue un ensayo clínico aleatorizado. 151 gestantes sanas fueron evaluadas mediante un ecocardiograma y un electrocardiograma en la semana 20 y 34 de gestación. Un total de 89 gestantes participaron en un programa de ejercicio físico (GE) desde el primer hasta el tercer trimestre de embarazo, constituido principalmente por 25-30 minutos de trabajo aeróbico (55-60% de la frecuencia cardiaca de reserva), trabajo de fortalecimiento general y específico, y un trabajo de tonificación del suelo pélvico; desarrollado 3 días a la semana con una duración de 55-60 minutos cada sesión. Las gestantes aleatoriamente asignadas al grupo de control (GC; n=62) permanecieron sedentarias durante el embarazo. El estudio fue aprobado por el Comité Ético de investigación clínica del Hospital Universitario de Fuenlabrada. Resultados: Las características basales fueron similares entre ambos grupos. A diferencia del GC, las gestantes del GE evitaron el descenso significativo del gasto cardiaco indexado, entre el 2º y 3ºT de embarazo, y conservaron el patrón geométrico normal del ventrículo izquierdo; mientras que en el GC cambió hacia un patrón de remodelado concéntrico. En la semana 20, las gestantes del GE presentaron valores significativamente menores de frecuencia cardiaca (GC: 79,56±10,76 vs. GE: 76,05±9,34; p=0,04), tensión arterial sistólica (GC: 110,19±10,23 vs. GE: 106,04±12,06; p=0,03); tensión arterial diastólica (GC: 64,56±7,88 vs. GE: 61,81±7,15; p=0,03); tiempo de relajación isovolumétrica (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); y un mayor tiempo de deceleración de la onda E (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). En la semana 34, el GE presentó valores significativamente superiores de volumen sistólico (GC: 51,13±11,85 vs. GE: 56,21±12,79 p=0,04), de llenado temprano del ventrículo izquierdo (E) (GC: 78,38±14,07 vs. GE: 85,30±16,62; p=0,02) y de tiempo de deceleración de la onda E (GC: 130,35±37,11 vs. GE: 146,61±43,40; p=0,04). Conclusión: La práctica regular de ejercicio físico durante el embarazo puede producir adaptaciones positivas sobre el sistema cardiovascular materno durante el tercer trimestre de embarazo, además de ayudar en el control de sus factores de riesgo, sin alterar la salud materno-fetal. ABSTRACT Background: Several changes occur in the maternal cardiovascular system during pregnancy. These changes produce a considerable stress in this system, especially during the third trimester, which can be increased in presence of some risk factors. The aims of this study were, to assess the maternal cardiac adaptations in a specific exercise program; its safety on the maternal cardiovascular system and pregnancy outcomes; and its effectiveness in the control of cardiovascular risk factors. Material and methods: A randomized controlled trial was designed. 151 healthy pregnant women were assessed by an echocardiography and electrocardiography at 20 and 34 weeks of gestation. A total of 89 pregnant women participated in a physical exercise program (EG) from the first to the third trimester of pregnancy. It consisted of 25-30 minutes of aerobic conditioning (55-60% of their heart rate reserve), general and specific strength exercises, and a pelvic floor muscles training; 3 times per weeks during 55-60 minutes per session. Pregnant women randomized allocated to the control group (CG) remained sedentary during pregnancy. The study was approved by the Research Ethics Committee of Hospital Universitario de Fuenlabrada. Results: Baseline characteristics were similar between groups. Difference from the CG, pregnant women from the EG prevented the significant decrease of the cardiac output index, between the 2nd and 3rd trimester of pregnancy, and preserved the normal left ventricular pattern; whereas in the CG shifted to concentric remodeling pattern. At 20 weeks, women in the EG had significant lower heart rate (CG: 79,56±10,76 vs. EG: 76,05±9,34; p=0,04), systolic blood pressure (CG: 110,19±10,23 vs. EG: 106,04±12,06; p=0,03); diastolic blood pressure (CG: 64,56±7,88 vs. EG: 61,81±7,15; p=0,03); isovolumetric relaxation time (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); and a higher deceleration time of E Wave (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). At 34 weeks, the EG had a significant higher stroke volume (CG: 51,13±11,85 vs. EG: 56,21±12,79 p=0,04), early filling of left ventricular (E) (CG: 78,38±14,07 vs. EG: 85,30±16,62; p=0,02) and deceleration time of E wave (CG: 130,35±37,11 vs. EG:146,61±43,40; p=0,04). Conclusion: Physical regular exercise program during pregnancy may produce positive maternal cardiovascular adaptations during the third trimester of pregnancy. In addition, it helps to control the cardiovascular risk factors without altering maternal and fetus health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the inclusion of oat hulls (OH) and sugar beet pulp (SBP) in the diet on gizzard characteristics, apparent ileal nutrient digestibility (AID), and Clostridium perfringens, Enterobacteriaceae, and Lactobacillus proliferation in the ceca were studied in 36 d?old broilers. There were a control diet with a low CF content (1.61%) and 2 additional diets that resulted from the dilution of this feed with 5% of either OH or SBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamic floor loads induced by crowds in gymnasium or stadium structures are commonly modelled by superposition of the individual contributions using reduction factors for the different Fourier coefficients. These Fourier coefficients and the reduction factors are calculated using full scale measurements. Generally the testing is performed on platforms or structures that can be considered rigid, such that the natural frequencies are higher than the frequencies of the spectator movement. In this paper we shall present the testing done on a structure that used to be a gymnasium as well as the procedure used to identify its dynamic properties and a first evaluation of the socalled “group effect”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Accurate delineation of the rectum is of high importance in off-line adaptive radiation therapy since it is a major dose-limiting organ in prostate cancer radiotherapy. The intensity-based deformable image registration (DIR) methods cannot create a correct spatial transformation if there is no correspondence between the template and the target images. The variation of rectal filling, gas, or feces, creates a noncorrespondence in image intensities that becomes a great obstacle for intensity-based DIR. Methods: In this study the authors have designed and implemented a semiautomatic method to create a rectum mask in pelvic computed tomography (CT) images. The method, that includes a DIR based on the demons algorithm, has been tested in 13 prostate cancer cases, each comprising of two CT scans, for a total of 26 CT scans. Results: The use of the manual segmentation in the planning image and the proposed rectum mask method (RMM) method in the daily image leads to an improvement in the DIR performance in pelvic CT images, obtaining a mean value of overlap volume index = 0.89, close to the values obtained using the manual segmentations in both images. Conclusions: The application of the RMM method in the daily image and the manual segmentations in the planning image during prostate cancer treatments increases the performance of the registration in presence of rectal fillings, obtaining very good agreement with a physician's manual contours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is still an open question whether subjective memory complaints (SMC) can actually be considered to be clinically relevant predictors for the development of an objective memory impairment and even dementia. There is growing evidence that suggests that SMC are associated with an increased risk of dementia and with the presence of biological correlates of early Alzheimer's disease. In this paper, in order to shed some light on this issue, we try to discern whether subjects with SMC showed a different profile of functional connectivity compared with subjects with mild cognitive impairment (MCI) and healthy elderly subjects. In the present study, we compare the degree of synchronization of brain signals recorded with magnetoencephalography between three groups of subjects (56 in total): 19 with MCI, 12 with SMC and 25 healthy controls during a memory task. Synchronization likelihood, an index based on the theory of nonlinear dynamical systems, was used to measure functional connectivity. Briefly, results show that subjects with SMC have a very similar pattern of connectivity to control group, but on average, they present a lower synchronization value. These results could indicate that SMC are representing an initial stage with a hypo-synchronization (in comparison with the control group) where the brain system is still not compensating for the failing memory networks, but behaving as controls when compared with the MCI subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Accurate delineation of the rectum is of high importance in off-line adaptive radiation therapy since it is a major dose-limiting organ in prostate cancer radiotherapy. The intensity-based deformable image registration (DIR) methods cannot create a correct spatial transformation if there is no correspondence between the template and the target images. The variation of rectal filling, gas, or feces, creates a noncorrespondence in image intensities that becomes a great obstacle for intensity-based DIR. Methods: In this study the authors have designed and implemented a semiautomatic method to create a rectum mask in pelvic computed tomography (CT) images. The method, that includes a DIR based on the demons algorithm, has been tested in 13 prostate cancer cases, each comprising of two CT scans, for a total of 26 CT scans. Results: The use of the manual segmentation in the planning image and the proposed rectum mask method (RMM) method in the daily image leads to an improvement in the DIR performance in pelvic CT images, obtaining a mean value of overlap volume index = 0.89, close to the values obtained using the manual segmentations in both images. Conclusions: The application of the RMM method in the daily image and the manual segmentations in the planning image during prostate cancer treatments increases the performance of the registration in presence of rectal fillings, obtaining very good agreement with a physician's manual contours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Civil engineering structures such as floor systems with open-plan layout or lightweight footbridges are susceptible to excessive level of vibrations caused by human loading. Active vibration control (AVC) via inertial mass actuators has been shown to be a viable technique to mitigate vibrations, allowing structures to satisfy vibration serviceability limits. Most of the AVC applications involve the use of SISO (single input single-output) strategies based on collocated control. However, in the case of floor structures, in which mostof the vibration modes are locally spatially distributed, SISO or multi-SISO strategies are quite inefficient. In this paper, a MIMO (multi-inputs multi-outputs) control in decentralised and centralised configuration is designed. The design process simultaneously finds the placement of multiple actuators and sensors and the output feedback gains. Additionally, actuator dynamics, actuator nonlinearities and frequency and time weightings are considered into the design process. Results with SISO and decentralised and centralised MIMO control (for a given number of actuators and sensors) are compared, showing the advantages of MIMO control for floor vibration control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoplamiento del sistema informático de control de piso de producción (SFS) con el conjunto de equipos de fabricación (SPE) es una tarea compleja. Tal acoplamiento involucra estándares abiertos y propietarios, tecnologías de información y comunicación, entre otras herramientas y técnicas. Debido a la turbulencia de mercados, ya sea soluciones personalizadas o soluciones basadas en estándares eventualmente requieren un esfuerzo considerable de adaptación. El concepto de acoplamiento débil ha sido identificado en la comunidad de diseño organizacional como soporte para la sobrevivencia de la organización. Su presencia reduce la resistencia de la organización a cambios en el ambiente. En este artículo los resultados obtenidos por la comunidad de diseño organizacional son identificados, traducidos y organizados para apoyar en la solución del problema de integración SFS-SPE. Un modelo clásico de acoplamiento débil, desarrollado por la comunidad de estudios de diseño organizacional, es resumido y trasladado al área de interés. Los aspectos claves son identificados para utilizarse como promotores del acoplamiento débil entre SFS-SPE, y presentados en forma de esquema de referencia. Así mismo, este esquema de referencia es presentado como base para el diseño e implementación de una solución genérica de acoplamiento o marco de trabajo (framework) de acoplamiento, a incluir como etapa de acoplamiento débil entre SFS y SPE. Un ejemplo de validación con varios conjuntos de equipos de fabricación, usando diferentes medios físicos de comunicación, comandos de controlador, lenguajes de programación de equipos y protocolos de comunicación es presentado, mostrando un nivel aceptable de autonomía del SFS. = Coupling shop floor software system (SFS) with the set of production equipment (SPE) becomes a complex task. It involves open and proprietary standards, information and communication technologies among other tools and techniques. Due to market turbulence, either custom solutions or standards based solutions eventually require a considerable effort of adaptation. Loose coupling concept has been identified in the organizational design community as a compensator for organization survival. Its presence reduces organization reaction to environment changes. In this paper the results obtained by the organizational de sign community are identified, translated and organized to support the SFS-SPE integration problem solution. A classical loose coupling model developed by organizational studies community is abstracted and translated to the area of interest. Key aspects are identified to be used as promoters of SFS-SPE loose coupling and presented in a form of a reference scheme. Furthermore, this reference scheme is proposed here as a basis for the design and implementation of a generic coupling solution or coupling framework, that is included as a loose coupling stage between SFS and SPE. A validation example with various sets of manufacturing equipment, using different physical communication media, controller commands, programming languages and wire protocols is presented, showing an acceptable level of autonomy gained by the SFS.