12 resultados para Nuclear saline water conversion plants.

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Germination of macroconidia and/or microconidia of 24 strains of Fusarium solani, F. chlamydosporum, F. culmorum, F. equiseti, F. verticillioides, F. sambucinum, F. oxysporum and F. proliferatum isolated from fluvial channels and sea beds of the south-eastern coast of Spain, and three control strains (F. oxysporum isolated from affected cultures) was studied in distilled water in response to a range of water potentials adjusted with NaCI. (0, -13.79, -41.79, -70.37, -99.56 and -144.54 bars). The vialibility (UFC/ml) of suspension was also tested in three time periods (0,24 and 48h). Conidia always germinated in distilled water. The pattern of conidial germination obseved of F. verticillioides, F. oxysporum, F. proliferatum, F. chlamydosporum and F. culmorum was similar. A great diminution of spore germination was found in -13.79 bars solutions. Spore germination percentage for F. solani isolates was maximal at 48 h. and -13.79 bars with 21.33% spore germination, 16% higher than germination in distilled water. F. equiseti shows the maximum germination percentage in -144.54 bars solution in 24 h time with 12.36% germination. These results did not agree with those obtained in the viability test where maximum germination was found in distilled water. The viability analysis showed the great capacity of F. verticilloides strains to form viable colonies, even in such extreme conditions as -144,54 bars after 24 h F. proliferatum colony formation was prevented in the range of -70.37 bars. These results show the clear affectation of water potential to conidia germination of Fusaria. The ability of certain species of Fusarium to develop a saprophytic life in the salt water of the Mediterraneam Sea could be certain. Successful germination, even under high salty media conditions, suggests taht Fusarium spp. could have a competitive advantage over other soil fungi in crops irrigated with saline water. In the specific case of F. solani, water potential of -13.79 bars affected germination positively. It could indicate that F. solani has an special physiological mechanism of survival in low water potential environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La disponibilidad hídrica es uno de los principales factores que determinan el rendimiento del viñedo en muchas regiones vitícolas, por lo que sus consecuencias han sido ampliamente estudiadas. Sin embargo, para una cantidad de agua de riego determinada, otros aspectos como la frecuencia de aplicación, o la combinación entre el caudal de los goteros y la distancia entre los mismos (es decir, el patrón de distribución de agua en el suelo), pueden jugar un papel relevante, pero estos factores han sido poco estudiados. El objetivo de este trabajo ha sido evaluar las implicaciones agronómicas y fisiológicas de dos frecuencias de riego (IrrF, cada 2 y 4 días) y dos patrones de distribución de agua (DisP, goteros de 2 L h-1 separados 0,6 m vs. goteros de 4 L h-1 separados 1,2 m). El experimento se llevó a cabo durante cuatro temporadas consecutivas en un viñedo cv. Syrah con un suelo arcilloso en el centro de España, y los dos factores fueron evaluados bajo dos condiciones de disponibilidad hídrica (Baja: 20% de ETo y Media: 40% de ETo). El efecto de la frecuencia de riego y el patrón de distribución de agua en la respuesta agronómica del cv. Syrah se ha estudiado en el capítulo 1. La frecuencia de riego y el patrón de distribución de agua en el suelo afectaron a algunos aspectos de los componentes de rendimiento y desarrollo vegetativo en las dos condiciones de disponibilidad hídrica, aunque los efectos observados no fueron los mismos todos los años. Los efectos fueron más evidentes para IrrF en condiciones de baja disponibilidad hídrica y para DisP en condiciones de disponibilidad hídrica media. Dos de los cuatro años del experimento, el pasar de frecuencia de riego de 2 días a 4 días causó un incremento medio de rendimiento del 20% para la situación de baja disponibilidad hídrica. La textura del suelo, sin duda ha condicionado los resultados obtenidos en los tratamientos regados con el 20% de la ETo, ya que regar cada dos días implicaba la aplicación de pequeñas cantidades de agua y se formaban bulbos de riego superficiales, probablemente favoreciendo las pérdidas por evaporación. En el capítulo 2, se ha analizado el efecto de la frecuencia de riego y del patrón de distribución de agua en el estado hídrico de la planta y el intercambio gaseoso a nivel de hoja con el fin de explicar las diferencias observadas en la respuesta agronómica. En lo que respecta a la frecuencia de riego, en condiciones de baja disponibilidad hídrica, las plantas regadas cada 4 días (plantas 4d), mostraron mayores tasas de asimilación neta y conductancia estomática que las plantas regadas cada 2 días (plantas 2d), lo que es consistente con la hipótesis de que con la frecuencia de riego de 2 días se produjo una pérdida de eficiencia del uso del agua, probablemente debido a una mayor evaporación como consecuencia del hecho de que el volumen de suelo mojado creado era pequeño y cerca de la superficie. En condiciones de disponibilidad hídrica media, las diferencias en el intercambio gaseoso a nivel de hoja fueron mucho más pequeñas. Al comienzo del verano cada frecuencia de riego se comportó mejor uno de los días de medida, compensando al final del ciclo de riego de 4 días. Sin embargo, a medida que avanzó el verano y el déficit de agua se hizo más alto, las diferencias significativas aparecieron sólo en el 'día 4' del ciclo de riego, cuando las plantas 2d se comportaron mejor que las plantas regadas 4d que llevaban tres días sin regarse. Estas diferencias fisiológicas fueron menores que en condiciones de baja disponibilidad hídrica y al parecer no suficientes para afectar el comportamiento agronómico. En cuanto al patrón de distribución de agua, el efecto fue poco significativo, pero la mayor densidad de goteros tendió a presentar un mayor intercambio gaseoso a nivel de hoja, especialmente a media mañana. El efecto fue más importante para las condiciones de disponibilidad hídrica media. En el capítulo 3, se han comparado las relaciones entre el intercambio gaseoso a nivel de hoja, el estado hídrico y la demanda atmosférica, con el fin de explicar los cambios en la intensidad de la respuesta fisiológica observados en el Capítulo 2. No se han encontrado diferencias en dichas relaciones para el patrón de distribución de agua, por lo que sólo se ha analizado el efecto de la frecuencia de riego. El estudio se ha centrado fundamentalmente en si las plantas mostraron una respuesta fisiológica diferente a los cambios en el estado hídrico y en la demanda atmosférica según el tiempo transcurrido desde el último riego. Las diferencias observadas explican los resultados obtenidos en los capítulos anteriores, y sugieren la existencia de procesos de aclimatación vinculados a la frecuencia de riego y a la disponibilidad hídrica. Las plantas bajo condiciones de baja disponibilidad hídrica se mostraron más aclimatadas al estrés hídrico que aquellas en condiciones de disponibilidad hídrica media. La frecuencia de riego afectó claramente la relación entre los parámetros de intercambio gaseoso a nivel de hoja, el estado hídrico de la planta y las condiciones atmosféricas, y junto con la cantidad de agua aplicada tuvo implicaciones en el desarrollo de mecanismos de aclimatación que afectaron a la respuesta fisiológica de la planta, afectando a la eficiencia del riego. ABSTRACT Water availability is one of the major factors that determine vineyard performance in many grape growing regions, so its implications have been widely studied before. However, for a given irrigation water amount, other aspects such as application frequency, or emitter spacing and flow rate (i.e., distribution pattern), may play a relevant role, but these factors have been scarcely studied. The aim of this work was to evaluate the agronomic and physiological implications of two irrigation frequencies (IrrF, every 2 and 4 days) and two water distribution patterns (DisP, 2 L h−1 emitters every 0.6 m vs. 4 L h−1 emitters every 1.2 m). The experiment was carried out during four consecutive seasons in a cv. Syrah vineyard with a clay soil in central Spain, and the two factors were evaluated under two water availability conditions (LOW WA: 20% of ETo and MEDIUM WA: 40% of ETo). The effect of irrigation frequency and water distribution pattern on the agronomical response of cv. Syrah was studied in Chapter 1. IrrF and DisP affected some aspects of vegetative development and yield components under both water availability conditions, although the effects observed were not the same every year. The effects were more evident for IrrF under low water availability and for DisP under medium water availability. Two out of the four years of the experiment, the change of irrigation frequency from 2 days to 4 days promoted an average yield increase of 20% for the LOW WA situation. Soil texture certainly conditioned the results obtained under LOW WA conditions, since high frequency irrigation implied applying small amounts of water that resulted in limited superficial water bulbs, which probably favored water evaporation. In Chapter 2, the effect of irrigation frequency and water distribution pattern on plant water status and leaf gas exchange was analyzed to explain the differences observed in the agronomical response. Concerning irrigation frequency, under LOW WA conditions, applying irrigation every 4 days, resulted in higher net assimilation rates and stomatal conductance than doing it every 2 days, supporting the hypothesis that the latter frequency resulted in a water use efficiency loss, probably due to higher evaporation as a consequence of the fact the wetted soil volume created was small and close to the surface. Under MEDIUM WA conditions, differences in leaf gas exchange were much smaller. At the beginning of the summer each irrigation frequency behaved better one of the measurements days, compensating at the end of the 4-day irrigation cycle. However, as the summer progressed and water deficit became higher, significant differences appeared only on ‘day 4’ of the irrigation cycle, when 2d plants behaved better than 4d plants. These physiological differences were smaller than under LOW WA conditions and apparently not sufficient to affect agronomical performance. Regarding water distribution pattern, the effect was less significant but the closest emitter spacing resulted in general terms in a higher leaf gas exchange, especially at midmorning. The effect was more noticeable for MEDIUM WA conditions. In Chapter 3, the relationships between leaf gas exchange and leaf water status and atmospheric demand were compared to explain the changes in the intensity of the physiological response observed in Chapter 2. No differences were found in the relationships for water distribution pattern, so only the effect of irrigation frequency was analyzed focusing on whether the plants have a different physiological response to changes in water status and atmospheric demand according to the time elapsed since the last irrigation. Differences observed in the relationships explained the results obtained in the previous chapters, and point at the occurrence of acclimation processes linked to irrigation frequency and to water availability. Plants under LOW WATER AVAILABILITY conditions seemed to be more acclimated to water stress than those under MEDIUM WATER AVAILABILITY conditions. Irrigation frequency clearly affected the relationship between leaf gas exchange parameters, plant water status and atmospheric conditions, and together with the amount of water applied had implications in the development of acclimation mechanisms that affected plant physiological response, thus affecting irrigation efficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta Tesis Doctoral tiene como principal objetivo el obtener una cadena de tratamientos seguros de aguas seriados que nos permita asegurar la calidad de las aguas para consumo humano en caso de emergencias, de tal forma que se minimicen los efectos de acciones hostiles, como sabotajes o actos terroristas, desastres naturales, etc y buscar soluciones adecuadas para garantizar en este caso la salud. Las plantas de tratamientos de aguas existentes comercialmente no aseguran dicha calidad y la documentación sobre el tema presenta vacíos de conocimiento, contradicciones entre resultados de investigaciones o insostenibilidad de conclusiones de las mismas. Estas carencias nos permiten determinar los aspectos a tratar durante la investigación. Por ello, este objetivo se concretó en tres acciones: Investigar sobre rendimientos de plantas convencionales en eliminación de microorganismos y productos tóxicos y peligrosos. Introducir mejoras que garanticen el rendimiento de las plantas convencionales. Investigar sobre la conveniencia de complementar las instalaciones existentes buscando seguridad y garantía sanitaria. Y se desarrollaron tres líneas de investigación: LI 1 “Inorgánicos”: Investigación sobre la eliminación de los metales boro, cobre y molibdeno mediante procesos de intercambio iónico y de coagulaciónfloculación- decantación. LI 2 “Compuestos Orgánicos Volátiles”: Investigación sobre la eliminación de los compuestos orgánicos 1,1 dicloroetano, 1,2 dicloroetano, clorobenceno, 1,3 dicloropropeno y hexacloro 1,3 butadieno mediante procesos de carbón activo granular y de oxidación avanzada. LI 3 “Plantas portátiles”: Investigación sobre plantas existentes portátiles para verificar su rendimiento teórico y proponer mejoras. Estas líneas de investigación se desarrollaron tanto en el nivel teórico como en el empírico, bien sea en laboratorio como en campo. A lo largo del documento se demuestra que las principales fuentes de contaminación, salvo la degradación de yacimientos naturales, proceden de la actividad humana (efluentes industriales y agrícolas, aguas residuales y actividades beligerantes) que provocan un amplio espectro de enfermedades por lo que dificultan tanto la definición de la fuente como la anticipada detección de la enfermedad. Las principales conclusiones que se obtuvieron están relacionadas con el rendimiento de eliminación de los parámetros tras la aplicación de los procesos y plantas de tratamiento de aguas anteriormente reseñadas. Sin embargo, el verdadero elemento designador de originalidad de esta Tesis Doctoral, tal como se ha reseñado arriba, radica en la definición de un sistema seriado de procesos de tratamiento de aguas que asegura la calidad en caso de emergencia. Éste se define en el siguiente orden: pretratamiento, oxidación, coagulación-floculación-decantación, filtración por arena, intercambio iónico, carbón activo granular, microfiltración, radiación UV, ósmosis inversa, radiación UV y cloración final. The main objective of this Thesis is to obtain a chain of stepwise safe water treatments that allow us to ensure the quality of water for human consumption in case of emergencies, so that the effects of hostile actions, such as sabotage or terrorism, natural disasters, etc. and seek appropriate solutions in this case to ensure health. The existing commercial water treatment plants do not ensure quality, and the documentation on the subject presents knowledge gaps or contradictions. These gaps allow us to determine the issues to be discussed during the investigation. Therefore, this objective was manifested in three actions: Researching yields in commercial plants and microorganisms, or toxic and dangerous products removal. Improvements to ensure the performance of conventional plants. Inquire about the advisability of implementing existing facilities for safety and health guarantee. And three lines of research are developed: LI 1 “Inorganic elements”: Research removing metals iron, copper and molybdenum by ion exchange processes and coagulation-flocculation-decantation. LI 2 “Volatile Organic Compounds”: Research removing organic compounds 1,1 dichloroethane, 1,2 dichloroethane, chlorobenzene, 1,3-dichloropropene and 1,3-butadiene hexachloro through processes of granular activated carbon and advanced oxidation. LI 3 “Compact Water Treatment Plants: Research on existing packaged plants to verify theoretical performance and suggest improvements. These lines of research are developed both theoretically and empirically, both in the laboratory and in the field. Throughout the document, it is evident that the main sources of pollution, other than the degradation of natural deposits, come from human activity (industrial and agricultural effluents, sewage and belligerent activities) which cause a broad spectrum of diseases which hamper both the definition of the source and the early detection of the disease. The main conclusions drawn are related to both the removal efficiency parameters after application of processes and treatment plants outlined above water. However, the real designator of originality of this thesis, such as outlined above, lies in the definition of a serial system water treatment processes assuring quality in case of emergency. This is defined in the following order: pretreatment, oxidation, coagulation-flocculation-sedimentation, sand filtration, ion exchange, granular activated carbon, microfiltration, UV radiation, reverse osmosis, UV radiation and final chlorination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La reutilización de efluentes depurados siempre ha sido una opción en lugares con déficit coyuntural o estructural de recursos hídricos, se haya o no procedido a la regulación y planificación de esta práctica. La necesidad se crea a partir de las demandas de una zona, normalmente riego agrícola, que ven un mejor desarrollo de su actividad por contar con este recurso. España es el país de la UE que más caudal reutiliza, y está dentro de los diez primeros a nivel mundial. La regulación de esta práctica por el RD 1620/2007, ayudó a incorporar la reutilización de efluentes depurados a la planificación hidrológica como parte de los programas de medidas, con objeto de mitigar presiones, como son las extracciones de agua superficial y subterránea, o mejoras medioambientales evitando un vertido. El objeto de este trabajo es conocer la situación de la reutilización de efluentes depurados en España, los diferentes escenarios y planteamientos de esta actividad, el desarrollo del marco normativo y su aplicabilidad, junto a los tratamientos que permiten alcanzar los límites de calidad establecidos en la normativa vigente, en función de los distintos usos. Además, se aporta un análisis de costes de las distintas unidades de tratamiento y tipologías de líneas de regeneración, tanto de las utilizadas después de un tratamiento secundario como de otras opciones de depuración, como son los biorreactores de membrana (MBRs). Para el desarrollo de estos objetivos, en primer lugar, se aborda el conocimiento de la situación de la reutilización en España a través de una base de datos diseñada para cubrir todos los aspectos de esta actividad: datos de la estación depuradora de aguas residuales (EDAR), de la estación regeneradora (ERA), caudales depurados, reutilizados, volúmenes utilizados y ubicación de los distintos usos, tipos de líneas de tratamiento, calidades del agua reutilizada, etc. Las principales fuentes de información son las Confederaciones Hidrográficas (CCHH) a través de las concesiones de uso del agua depurada, las entidades de saneamiento y depuración de las distintas comunidades autónomas (CCAA), ayuntamientos, Planes Hidrológicos de Cuenca (PHC) y visitas a las zonas más emblemáticas. Además, se revisan planes y programas con el fin de realizar una retrospectiva de cómo se ha ido consolidando y desarrollando esta práctica en las distintas zonas de la geografía española. Se han inventariado 322 sistemas de reutilización y 216 tratamientos de regeneración siendo el más extendido la filtración mediante filtro arena seguido de una desinfección mediante hipoclorito, aunque este tratamiento se ha ido sustituyendo por un físico-químico con decantación lamelar, filtro de arena y radiación ultravioleta, tratamiento de regeneración convencional (TRC), y otros tratamientos que pueden incluir membranas, tratamientos de regeneración avanzados (TRA), con dosificación de hipoclorito como desinfección residual, para adaptarse al actual marco normativo. El uso más extendido es el agrícola con el 70% del caudal total reutilizado, estimado en 408 hm3, aunque la capacidad de los tratamientos de regeneración esperada para 2015, tras el Plan Nacional de Reutilización de Aguas (PNRA), es tres veces superior. Respecto al desarrollo normativo, en las zonas donde la reutilización ha sido pionera, las administraciones competentes han ido desarrollando diferentes recomendaciones de calidad y manejo de este tipo de agua. El uso agrícola, y en zonas turísticas, el riego de campos de golf, fueron los dos primeros usos que tuvieron algún tipo de recomendación incluso reglamentación. Esta situación inicial, sin una normativa a nivel estatal ni recomendaciones europeas, creó cierta incertidumbre en el avance de la reutilización tanto a nivel de concesiones como de planificación. En la actualidad sigue sin existir una normativa internacional para la reutilización y regeneración de efluentes depurados. Las recomendaciones de referencia a nivel mundial, y en concreto para el uso agrícola, son las de la OMS (Organización Mundial de la Salud) publicadas 1989, con sus posteriores revisiones y ampliaciones (OMS, 2006). Esta norma combina tratamientos básicos de depuración y unas buenas prácticas basadas en diferentes niveles de protección para evitar problemas sanitarios. Otra normativa que ha sido referencia en el desarrollo del marco normativo en países donde se realiza esta práctica, son las recomendaciones dadas por la Agencia Medioambiente Estadunidense (USEPA, 2012) o las publicadas por el Estado de California (Título 22, 2001). Estas normas establecen unos indicadores y valores máximos dónde el tratamiento de regeneración es el responsable de la calidad final en función del uso. Durante 2015, la ISO trabajaba en un documento para el uso urbano donde se muestra tanto los posibles parámetros que habría que controlar como la manera de actuar para evitar posibles riesgos. Por otro lado, la Comisión Europea (CE) viene impulsando desde el 2014 la reutilización de aguas depuradas dentro del marco de la Estrategia Común de Implantación de la Directiva Marco del Agua, y fundamentalmente a través del grupo de trabajo de “Programas de medidas”. Para el desarrollo de esta iniciativa se está planteando sacar para 2016 una guía de recomendaciones que podría venir a completar el marco normativo de los distintos Estados Miembros (EM). El Real Decreto 1620/2007, donde se establece el marco jurídico de la reutilización de efluentes depurados, tiende más a la filosofía implantada por la USEPA, aunque la UE parece más partidaria de una gestión del riesgo, donde se establecen unos niveles de tolerancia y unos puntos de control en función de las condiciones socioeconómicas de los distintos Estados, sin entrar a concretar indicadores, valores máximos o tratamientos. Sin embargo, en la normativa estadounidense se indican una serie de tratamientos de regeneración, mientras que, en la española, se hacen recomendaciones a este respecto en una Guía sin validez legal. Por tanto, queda sin regular los procesos para alcanzar estos estándares de calidad, pudiendo ser éstos no apropiados para esta práctica. Es el caso de la desinfección donde el uso de hipoclorito puede generar subproductos indeseables. En la Guía de recomendaciones para la aplicación del RD, publicada por el Ministerio de Agricultura y Medioambiente (MAGRAMA) en 2010, se aclaran cuestiones frecuentes sobre la aplicación del RD, prescripciones técnicas básicas para los sistemas de reutilización, y buenas prácticas en función del uso. Aun así, el RD sigue teniendo deficiencias en su aplicación siendo necesaria una revisión de la misma, como en las frecuencias de muestreo incluso la omisión de algunos parámetros como huevos de nematodos que se ha demostrado ser inexistentes tras un tratamiento de regeneración convencional. En este sentido, existe una tendencia a nivel mundial a reutilizar las aguas con fines de abastecimiento, incluir indicadores de presencia de virus o protozoos, o incluir ciertas tecnologías como las membranas u oxidaciones avanzadas para afrontar temas como los contaminantes emergentes. Otro de los objetivos de este trabajo es el estudio de tipologías de tratamiento en función de los usos establecidos en el RD 1620/2007 y sus costes asociados, siendo base de lo establecido a este respecto en la Guía y PNRA anteriormente indicados. Las tipologías de tratamiento propuestas se dividen en líneas con capacidad de desalar y las que no cuentan con una unidad de desalación de aguas salobres de ósmosis inversa o electrodiálisis reversible. Se realiza esta división al tener actuaciones en zonas costeras donde el agua de mar entra en los colectores, adquiriendo el agua residual un contenido en sales que es limitante en algunos usos. Para desarrollar este objetivo se han estudiado las unidades de tratamiento más implantadas en ERAs españolas en cuanto a fiabilidad para conseguir determinada calidad y coste, tanto de implantación como de explotación. El TRC, tiene un coste de implantación de 28 a 48 €.m-3.d y de explotación de 0,06 a 0,09 €. m-3, mientras que, si se precisara desalar, este coste se multiplica por diez en la implantación y por cinco en la explotación. En caso de los usos que requieren de TRA, como los domiciliarios o algunos industriales, los costes serían de 185 a 398 €.m-3.d en implantación y de 0,14 a 0,20 €.m-3 en explotación. En la selección de tecnologías de regeneración, la capacidad del tratamiento en relación al coste es un indicador fundamental. Este trabajo aporta curvas de tendencia coste-capacidad que sirven de herramienta de selección frente a otros tratamientos de regeneración de reciente implantación como son los MBR, u otros como la desalación de agua de mar o los trasvases entre cuencas dentro de la planificación hidrológica. En España, el aumento de las necesidades de agua de alta calidad en zonas con recursos escasos, aumento de zonas sensibles como puntos de captación para potables, zonas de baño o zonas de producción piscícola, y en ocasiones, el escaso terreno disponible para la implantación de nuevas plantas depuradoras (EDARs), han convertido a los MBRs, en una opción dentro del marco de la reutilización de aguas depuradas. En este trabajo, se estudia esta tecnología frente a los TRC y TRA, aportando igualmente curvas de tendencia coste-capacidad, e identificando cuando esta opción tecnológica puede ser más competitiva frente a los otros tratamientos de regeneración. Un MBR es un tratamiento de depuración de fangos activos donde el decantador secundario es sustituido por un sistema de membranas de UF o MF. La calidad del efluente, por tanto, es la misma que el de una EDAR seguida de un TRA. Los MBRs aseguran una calidad del efluente para todos los usos establecidos en el RD, incluso dan un efluente que permite ser directamente tratado por las unidades de desalación de OI o EDR. La implantación de esta tecnología en España ha tenido un crecimiento exponencial, pasando de 13 instalaciones de menos de 5.000 m3. d-1 en el 2006, a más de 55 instalaciones en operación o construcción a finales del 2014, seis de ellas con capacidades por encima de los 15.000 m3. d-1. Los sistemas de filtración en los MBR son los que marcan la operación y diseño de este tipo de instalaciones. El sistema más implantado en España es de membrana de fibra hueca (MFH), sobre todo para instalaciones de gran capacidad, destacando Zenon que cuenta con el 57% de la capacidad total instalada. La segunda casa comercial con mayor número de plantas es Kubota, con membranas de configuración placa plana (MPP), que cuenta con el 30 % de la capacidad total instalada. Existen otras casas comerciales implantadas en MBR españoles como son Toray, Huber, Koch o Microdym. En este documento se realiza la descripción de los sistemas de filtración de todas estas casas comerciales, aportando información de sus características, parámetros de diseño y operación más relevantes. El estudio de 14 MBRs ha posibilitado realizar otro de los objetivos de este trabajo, la estimación de los costes de explotación e implantación de este tipo de sistemas frente a otras alternativas de tratamiento de regeneración. En este estudio han participado activamente ACA y ESAMUR, entidades públicas de saneamiento y depuración de Cataluña y Murcia respectivamente, que cuentan con una amplia experiencia en la explotación de este tipo de sistemas. Este documento expone los problemas de operación encontrados y sus posibles soluciones, tanto en la explotación como en los futuros diseños de este tipo de plantas. El trabajo concluye que los MBRs son una opción más para la reutilización de efluentes depurados, siendo ventajosos en costes, tanto de implantación como de explotación, respecto a EDARs seguidas de TRA en capacidades por encima de los 10.000 m3.d-1. ABSTRACT The reuse of treated effluent has always been an option in places where a situational or structural water deficit exists, whether regulatory and/or planning efforts are completed or not. The need arises from the demand of a sector, commonly agricultural irrigation, which benefits of this new resource. Within the EU, Spain is ahead in the annual volume of reclaimed water, and is among the top ten countries at a global scale. The regulation of this practice through the Royal Decree 1620/2007 has helped to incorporate the water reuse to the hydrological plans as a part of the programme of measures to mitigate pressures such as surface or ground water extraction, or environmental improvements preventing discharges. The object of this study is to gain an overview of the state of the water reuse in Spain, the different scenarios and approaches to this activity, the development of the legal framework and its enforceability, together with the treatments that achieve the quality levels according to the current law, broken down by applications. Additionally, a cost analysis of technologies and regeneration treatment lines for water reclamation is performed, whereas the regeneration treatment is located after a wastewater treatment or other options such as membrane bioreactors (MBR). To develop the abovementioned objectives, the state of water reuse in Spain is studied by means of a database designed to encompass all aspects of the activity: data from the wastewater treatment plants (WWTP), from the water reclamation plants (WRP), the use of reclaimed water, treated water and reclaimed water annual volumes and qualities, facilities and applications, geographic references, technologies, regeneration treatment lines, etc. The main data providers are the River Basin authorities, through the concession or authorization for water reuse, (sanitary and wastewater treatment managers from the territorial governments, local governments, Hydrological Plans of the River Basins and field visits to the main water reuse systems. Additionally, a review of different plans and programmes on wastewater treatment or water reuse is done, aiming to put the development and consolidation process of this activity in the different regions of Spain in perspective. An inventory of 322 reuse systems and 216 regeneration treatments has been gathered on the database, where the most extended regeneration treatment line was sand filtration followed by hypochlorite disinfection, even though recently it is being replaced by physical–chemical treatment with a lamella settling system, depth sand filtration, and a disinfection with ultraviolet radiation and hypochlorite as residual disinfectant, named conventional regeneration treatment (CRT), and another treatment that may include a membrane process, named advanced regeneration treatment (ART), to adapt to legal requirements. Agricultural use is the most extended, accumulating 70% of the reclaimed demand, estimated at 408 hm3, even though the expected total capacity of WRPs for 2015, after the implementation of the National Water Reuse Plan (NWRP) is three times higher. According to the development of the water reuse legal framework, there were pioneer areas where competent authorities developed different quality and use recommendations for this new resource. Agricultural use and golf course irrigation in touristic areas were the first two uses with recommendations and even legislation. The initial lack of common legislation for water reuse at a national or European level created some doubts which affected the implementation of water reuse, both from a planning and a licensing point of view. Currently there is still a lack of common international legislation regarding water reuse, technologies and applications. Regarding agricultural use, the model recommendations at a global scale are those set by the World Health Organization published in 1989, and subsequent reviews and extensions about risk prevention (WHO, 2006). These documents combine wastewater treatments with basic regeneration treatments reinforced by good practices based on different levels of protection to avoid deleterious health effects. Another relevant legal reference for this practices has been the Environmental Protection Agency of the US (USEPA, 2012), or those published by the State of California (Title 22, 2001). These establish indicator targets and maximum thresholds where regeneration treatment lines are responsible for the final quality according to the different uses. During 2015, the ISO has worked on a document aimed at urban use, where the possible parameters to be monitored together with risk prevention have been studied. On the other hand, the European Commission has been promoting the reuse of treated effluents within the Common Implementation Strategy of the Water Framework Directive, mainly through the work of the Programme of Measures Working Group. Within this context, the publication of a recommendation guide during 2016 is intended, as a useful tool to fill in the legal gaps of different Member States on the matter. The Royal Decree 1620/2007, where the water reuse regulation is set, resembles the principles of the USEPA more closely, even though the EU shows a tendency to prioritize risk assessment by establishing tolerance levels and thresholds according to socioeconomic conditions of the different countries, without going into details of indicators, maximum thresholds or treatments. In contrast, in the US law, regeneration treatments are indicated, while in the Spanish legislation, the only recommendations to this respect are compiled in a non-compulsory guide. Therefore, there is no regulation on the different treatment lines used to achieve the required quality standards, giving room for inappropriate practices in this respect. This is the case of disinfection, where the use of hypochlorite may produce harmful byproducts. In the recommendation Guide for the application of the Royal Decree (RD), published by the Ministry of Agriculture and Environment (MAGRAMA) in 2010, clarifications of typical issues that may arise from the application of the RD are given, as well as basic technical parameters to consider in reuse setups, or good practices according to final use. Even so, the RD still presents difficulties in its application and requires a review on issues such as the sampling frequency of current quality parameters or even the omission of nematode eggs indicator, which have been shown to be absent after CRT. In this regard, there is a global tendency to employ water reuse for drinking water, including indicators for the presence of viruses and protozoans, or to include certain technologies such as membranes or advanced oxidation processes to tackle problems like emerging pollutants. Another of the objectives of this study is to provide different regeneration treatment lines to meet the quality requirements established in the RD 1620/2007 broken down by applications, and to estimate establishment and operational costs. This proposal has been based on what is established in the above mentioned Guide and NWRP. The proposed treatment typologies are divided in treatment trains with desalination, like reverse osmosis or reversible electrodialisis, and those that lack this treatment for brackish water. This separation is done due to coastal facilities, where sea water may permeate the collecting pipes, rising salt contents in the wastewater, hence limiting certain uses. To develop this objective a study of the most common treatment units set up in Spanish WRPs is conducted in terms of treatment train reliability to obtain an acceptable relationship between the required quality and the capital and operational costs. The CRT has an establishment cost of 28 to 48 €.m-3.d and an operation cost of 0.06 to 0.09 €.m-3, while, if desalination was required, these costs would increase tenfold for implementation and fivefold for operation. In the cases of uses that require ART, such as residential or certain industrial uses, the costs would be of 185 to 398 €.m-3.d for implementation and of 0.14 to 0.20 €.m-3 for operation. When selecting regeneration treatment lines, the relation between treatment capacity and cost is a paramount indicator. This project provides cost-capacity models for regeneration treatment trains. These may serve as a tool when selecting between different options to fulfill water demands with MBR facilities, or others such as sea water desalination plants or inter-basin water transfer into a water planning framework. In Spain, the requirement for high quality water in areas with low resource availability, the increasing number of sensitive zones, such as drinking water extraction, recreational bathing areas, fish protected areas and the lack of available land to set up new WWTPs, have turned MBRs into a suitable option for water reuse. In this work this technology is analyzed in contrast to CRT and ART, providing cost-capacity models, and identifying when and where this treatment option may outcompete other regeneration treatments. An MBR is an activated sludge treatment where the secondary settling is substituted by a membrane system of UF or MF. The quality of the effluent is, therefore, comparable to that of a WWTP followed by an ART. MBRs ensure a sufficient quality level for the requirements of the different uses established in the RD, even producing an effluent that can be directly treated in OI or EDR processes. The implementation of this technology in Spain has grown exponentially, growing from 13 facilities with less than 5000 m3.d-1 in 2006 to above 55 facilities operating by the end of 2014, 6 of them with capacities over 15000 m3.d-1. The membrane filtration systems for MBR are the ones that set the pace of operation and design of this type of facilities. The most widespread system in Spain is the hollow fiber membrane configuration, especially on high flow capacities, being Zenon commercial technology, which mounts up to 57% of the total installed capacity, the main contributor. The next commercial technology according to plant number is Kubota, which uses flat sheet membrane configuration, which mounts up to 30% of the total installed capacity. Other commercial technologies exist within the Spanish MBR context, such as Toray, Huber, Koch or Microdym. In this document an analysis of all of these membrane filtration systems is done, providing information about their characteristics and relevant design and operation parameters. The study of 14 full scale running MBRs has enabled to pursue another of the objectives of this work: the estimation of the implementation and operation costs of this type of systems in contrast to other regeneration alternatives. Active participation of ACA and ESAMUR, public wastewater treatment and reuse entities of Cataluña and Murcia respectively, has helped attaining this objective. A number of typical operative problems and their possible solutions are discussed, both for operation and plant design purposes. The conclusion of this study is that MBRs are another option to consider for water reuse, being advantageous in terms of both implementation and operational costs, when compared with WWTPs followed by ART, when considering flow capacities above 10000 m3.d-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El accidente de pérdida de refrigerante (LOCA) en un reactor nuclear es uno de los accidentes Base de Diseño más preocupantes y estudiados desde el origen del uso de la tecnología de fisión en la industria productora de energía. El LOCA ocupa, desde el punto de vista de los análisis de seguridad, un lugar de vanguardia tanto en el análisis determinista (DSA) como probabilista (PSA), cuya diferenciada perspectiva ha ido evolucionando notablemente en lo que al crédito a la actuación de las salvaguardias y las acciones del operador se refiere. En la presente tesis se aborda el análisis sistemático de de las secuencias de LOCA por pequeña y mediana rotura en diferentes lugares de un reactor nuclear de agua a presión (PWR) con fallo total de Inyección de Seguridad de Alta Presión (HPSI). Tal análisis ha sido desarrollado en base a la metodología de Análisis Integrado de Seguridad (ISA), desarrollado por el Consejo de Seguridad Nuclear (CSN) y consistente en la aplicación de métodos avanzados de simulación y PSA para la obtención de Dominios de Daño, que cuantifican topológicamente las probabilidades de éxito y daño en función de determinados parámetros inciertos. Para la elaboración de la presente tesis, se ha hecho uso del código termohidráulico TRACE v5.0 (patch 2), avalado por la NRC de los EEUU como código de planta para la simulación y análisis de secuencias en reactores de agua ligera (LWR). Los objetivos del trabajo son, principalmente: (1) el análisis exhaustivo de las secuencias de LOCA por pequeña-mediana rotura en diferentes lugares de un PWR de tres lazos de diseño Westinghouse (CN Almaraz), con fallo de HPSI, en función de parámetros de gran importancia para los transitorios, tales como el tamaño de rotura y el tiempo de retraso en la respuesta del operador; (2) la obtención y análisis de los Dominios de Daño para transitorios de LOCA en PWRs, de acuerdo con la metodología ISA; y (3) la revisión de algunos de los resultados genéricos de los análisis de seguridad para secuencias de LOCA en las mencionadas condiciones. Los resultados de la tesis abarcan tres áreas bien diferenciadas a lo largo del trabajo: (a) la fenomenología física de las secuencias objeto de estudio; (b) las conclusiones de los análisis de seguridad practicados a los transitorios de LOCA; y (c) la relevancia de las consecuencias de las acciones humanas por parte del grupo de operación. Estos resultados, a su vez, son de dos tipos fundamentales: (1) de respaldo del conocimiento previo sobre el tipo de secuencias analizado, incluido en la extensa bibliografía examinada; y (2) hallazgos en cada una de las tres áreas mencionadas, no referidos en la bibliografía. En resumidas cuentas, los resultados de la tesis avalan el uso de la metodología ISA como método de análisis alternativo y sistemático para secuencias accidentales en LWRs. ABSTRACT The loss of coolant accident (LOCA) in nuclear reactors is one of the most concerning and analized accidents from the beginning of the use of fission technology for electric power production. From the point of view of safety analyses, LOCA holds a forefront place in both Deterministic (DSA) and Probabilistic Safety Analysis (PSA), which have significantly evolved from their original state in both safeguard performance credibility and human actuation. This thesis addresses a systematic analysis of small and medium LOCA sequences, in different places of a nuclear Pressurized Water Reactor (PWR) and with total failure of High Pressure Safety Injection (HPSI). Such an analysis has been grounded on the Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Regulatory Body (CSN). ISA involves the application of advanced methods of simulation and PSA for obtaining Damage Domains that topologically quantify the likelihood of success and damage regarding certain uncertain parameters.TRACE v5.0 (patch 2) code has been used as the thermalhydraulic simulation tool for the elaboration of this work. Nowadays, TRACE is supported by the US NRC as a plant code for the simulation and analysis of sequences in light water reactors (LWR). The main objectives of the work are the following ones: (1) the in-depth analysis of small and medium LOCA sequences in different places of a Westinghouse three-loop PWR (Almaraz NPP), with failed HPSI, regarding important parameters, such as break size or delay in operator response; (2) obtainment and analysis of Damage Domains related to LOCA transients in PWRs, according to ISA methodology; and (3) review some of the results of generic safety analyses for LOCA sequences in those conditions. The results of the thesis cover three separated areas: (a) the physical phenomenology of the sequences under study; (b) the conclusions of LOCA safety analyses; and (c) the importance of consequences of human actions by the operating crew. These results, in turn, are of two main types: (1) endorsement of previous knowledge about this kind of sequences, which is included in the literature; and (2) findings in each of the three aforementioned areas, not reported in the reviewed literature. In short, the results of this thesis support the use of ISA-like methodology as an alternative method for systematic analysis of LWR accidental sequences.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the dynamic response of a hydro power plant for providing secondary regulation reserve is studied in detail. Special emphasis is given to the elastic water column effects both in the penstock and the tailrace tunnel. For this purpose, a nonlinear model based on the analogy between mass and momentum conservation equations of a water conduit and those of wave propagation in transmission lines is used. The influence of the plant configuration and design parameters on the fulfilment of the Spanish Electrical System Operator requirements is analysed

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the dynamic response of a hydro power plant for providing secondary regulation reserve is studied in detail. S pecial emphasis is given to the elastic water column effects both in the penstock and the tailrace tunnel. For this purpose, a nonline ar model based on the analogy between mass and momentum conservation equations of a water conduit and those of wave propagation in transmission lines is used. The influence of the plant configuration and design parameters on the fulfilment of the Spanish Electrical System Operator requirem ents is analysed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The advantages of fast-spectrum reactors consist not only of an efficient use of fuel through the breeding of fissile material and the use of natural or depleted uranium, but also of the potential reduction of the amount of actinides such as americium and neptunium contained in the irradiated fuel. The first aspect means a guaranteed future nuclear fuel supply. The second fact is key for high-level radioactive waste management, because these elements are the main responsible for the radioactivity of the irradiated fuel in the long term. The present study aims to analyze the hypothetical deployment of a Gen-IV Sodium Fast Reactor (SFR) fleet in Spain. A nuclear fleet of fast reactors would enable a fuel cycle strategy different than the open cycle, currently adopted by most of the countries with nuclear power. A transition from the current Gen-II to Gen-IV fleet is envisaged through an intermediate deployment of Gen-III reactors. Fuel reprocessing from the Gen-II and Gen-III Light Water Reactors (LWR) has been considered. In the so-called advanced fuel cycle, the reprocessed fuel used to produce energy will breed new fissile fuel and transmute minor actinides at the same time. A reference case scenario has been postulated and further sensitivity studies have been performed to analyze the impact of the different parameters on the required reactor fleet. The potential capability of Spain to supply the required fleet for the reference scenario using national resources has been verified. Finally, some consequences on irradiated final fuel inventory are assessed. Calculations are performed with the Monte Carlo transport-coupled depletion code SERPENT together with post-processing tools.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Spanish Young Generation in Nuclear (Jóvenes Nucleares, JJNN) is a non-profrt organization that depends on the Spanish Nuclear Society (Sociedad Nuclear Española, SNE).Since one of rts main goals is to spread the knowledge about nuclear power,severa! technical tours to facilities wrth an importan!role in the nuclear fuel cycle have been organized for the purpose ofleaming about the different stages of the Spanish tuel cycle. Spanish Young Generation in Nuclear had the opportunity to visit ENUSA Fuel Assembly Factory in Juzbado (Salamanca, Spain), Where it could be understood the front-end cycle which involves the uranium supply and storage, design and manufacturing of fuel bundles for European nuclear power plants. Alterwards, due to the tour of Almaraz NPP (PWR) and Santa María de Garoña NPP (BWR), rt could be comprehended how to obtain energy from this fuel in two different types of reactors.Furthermore,in these two plants, the facilities related to the back-end cycle could be toured. lt was possible to watch the Spent FuelPools, where the fuel bundles are stored under water until their activity is reduced enough to transport them to an Individual Temporary Storage Facility orto the Centralized Temporary Storage. Finally, a technical tour to ENSA Heavy Components Factory (ENSA) was accomplished, Where it could be experienced at first hand how different Nuclear Steam Supply System (NSSS) components and other nuclear elements, such as racks or shipping and storage casks for spent nuclear fuel, are manulactured. All these perlonned technical tours were a complete success thanks to a generous care and know-how of the wor1

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Four European fuel cycle scenarios involving transmutation options (in coherence with PATEROS and CPESFR EU projects) have been addressed from a point of view of resources utilization and economic estimates. Scenarios include: (i) the current fleet using Light Water Reactor (LWR) technology and open fuel cycle, (ii) full replacement of the initial fleet with Fast Reactors (FR) burning U?Pu MOX fuel, (iii) closed fuel cycle with Minor Actinide (MA) transmutation in a fraction of the FR fleet, and (iv) closed fuel cycle with MA transmutation in dedicated Accelerator Driven Systems (ADS). All scenarios consider an intermediate period of GEN-III+ LWR deployment and they extend for 200 years, looking for long term equilibrium mass flow achievement. The simulations were made using the TR_EVOL code, capable to assess the management of the nuclear mass streams in the scenario as well as economics for the estimation of the levelized cost of electricity (LCOE) and other costs. Results reveal that all scenarios are feasible according to nuclear resources demand (natural and depleted U, and Pu). Additionally, we have found as expected that the FR scenario reduces considerably the Pu inventory in repositories compared to the reference scenario. The elimination of the LWR MA legacy requires a maximum of 55% fraction (i.e., a peak value of 44 FR units) of the FR fleet dedicated to transmutation (MA in MOX fuel, homogeneous transmutation) or an average of 28 units of ADS plants (i.e., a peak value of 51 ADS units). Regarding the economic analysis, the main usefulness of the provided economic results is for relative comparison of scenarios and breakdown of LCOE contributors rather than provision of absolute values, as technological readiness levels are low for most of the advanced fuel cycle stages. The obtained estimations show an increase of LCOE ? averaged over the whole period ? with respect to the reference open cycle scenario of 20% for Pu management scenario and around 35% for both transmutation scenarios. The main contribution to LCOE is the capital costs of new facilities, quantified between 60% and 69% depending on the scenario. An uncertainty analysis is provided around assumed low and high values of processes and technologies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The supercritical Rankine power cycle offers a net improvement in plant efficiency compared with a subcritical Rankine cycle. For fossil power plants the minimum supercritical steam turbine size is about 450MW. A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013, confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe. In this context, this analysis is focused on integrating a line-focus solar field with a supercritical Rankine power cycle. For this purpose two heat transfer fluids were assessed: direct steam generation and molten salt Hitec XL. To isolate solar field from high pressure supercritical water power cycle, an intermediate heat exchanger was installed between linear solar collectors and balance of plant. Due to receiver selective coating temperature limitations, turbine inlet temperature was fixed 550ºC. The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output. Plant performance was assessed at design-point in the supercritical power plant (between 43-45% net plant efficiency depending on balance of plantconfiguration), and in the subcritical plant configuration (~40% net plant efficiency). Regarding the balance of plant configuration, direct reheating was adopted as the optimum solution to avoid any intermediate heat exchanger. One direct reheating stage between high pressure turbine and intermediate pressure turbine is the common practice; however, General Electric ultrasupercritical(350 bar) fossil power plants also considered doubled-reheat applications. In this study were analyzed heat balances with single-reheat, double-reheat and even three reheating stages. In all cases were adopted the proper reheating solar field configurations to limit solar collectors pressure drops. As main conclusion, it was confirmed net plant efficiency improvements in supercritical Rankine line-focus (parabolic or linear Fresnel) solar plant configurations are mainly due to the following two reasons: higher number of feed-water preheaters (up to seven)delivering hotter water at solar field inlet, and two or even three direct reheating stages (550ºC reheating temperature) in high or intermediate pressure turbines. However, the turbine manufacturer should confirm the equipment constrains regarding reheating stages and number of steam extractions to feed-water heaters.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El estudio de los ciclos del combustible nuclear requieren de herramientas computacionales o "códigos" versátiles para dar respuestas al problema multicriterio de evaluar los actuales ciclos o las capacidades de las diferentes estrategias y escenarios con potencial de desarrollo en a nivel nacional, regional o mundial. Por otra parte, la introducción de nuevas tecnologías para reactores y procesos industriales hace que los códigos existentes requieran nuevas capacidades para evaluar la transición del estado actual del ciclo del combustible hacia otros más avanzados y sostenibles. Brevemente, esta tesis se centra en dar respuesta a las principales preguntas, en términos económicos y de recursos, al análisis de escenarios de ciclos de combustible, en particular, para el análisis de los diferentes escenarios del ciclo del combustible de relativa importancia para España y Europa. Para alcanzar este objetivo ha sido necesaria la actualización y el desarrollo de nuevas capacidades del código TR_EVOL (Transition Evolution code). Este trabajo ha sido desarrollado en el Programa de Innovación Nuclear del CIEMAT desde el año 2010. Esta tesis se divide en 6 capítulos. El primer capítulo ofrece una visión general del ciclo de combustible nuclear, sus principales etapas y los diferentes tipos utilizados en la actualidad o en desarrollo para el futuro. Además, se describen las fuentes de material nuclear que podrían ser utilizadas como combustible (uranio y otros). También se puntualizan brevemente una serie de herramientas desarrolladas para el estudio de estos ciclos de combustible nuclear. El capítulo 2 está dirigido a dar una idea básica acerca de los costes involucrados en la generación de electricidad mediante energía nuclear. Aquí se presentan una clasificación de estos costos y sus estimaciones, obtenidas en la bibliografía, y que han sido evaluadas y utilizadas en esta tesis. Se ha incluido también una breve descripción del principal indicador económico utilizado en esta tesis, el “coste nivelado de la electricidad”. El capítulo 3 se centra en la descripción del código de simulación desarrollado para el estudio del ciclo del combustible nuclear, TR_EVOL, que ha sido diseñado para evaluar diferentes opciones de ciclos de combustibles. En particular, pueden ser evaluados las diversos reactores con, posiblemente, diferentes tipos de combustibles y sus instalaciones del ciclo asociadas. El módulo de evaluaciones económica de TR_EVOL ofrece el coste nivelado de la electricidad haciendo uso de las cuatro fuentes principales de información económica y de la salida del balance de masas obtenido de la simulación del ciclo en TR_EVOL. Por otra parte, la estimación de las incertidumbres en los costes también puede ser efectuada por el código. Se ha efectuado un proceso de comprobación cruzada de las funcionalidades del código y se descrine en el Capítulo 4. El proceso se ha aplicado en cuatro etapas de acuerdo con las características más importantes de TR_EVOL, balance de masas, composición isotópica y análisis económico. Así, la primera etapa ha consistido en el balance masas del ciclo de combustible nuclear actual de España. La segunda etapa se ha centrado en la comprobación de la composición isotópica del flujo de masas mediante el la simulación del ciclo del combustible definido en el proyecto CP-ESFR UE. Las dos últimas etapas han tenido como objetivo validar el módulo económico. De este modo, en la tercera etapa han sido evaluados los tres principales costes (financieros, operación y mantenimiento y de combustible) y comparados con los obtenidos por el proyecto ARCAS, omitiendo los costes del fin del ciclo o Back-end, los que han sido evaluado solo en la cuarta etapa, haciendo uso de costes unitarios y parámetros obtenidos a partir de la bibliografía. En el capítulo 5 se analizan dos grupos de opciones del ciclo del combustible nuclear de relevante importancia, en términos económicos y de recursos, para España y Europa. Para el caso español, se han simulado dos grupos de escenarios del ciclo del combustible, incluyendo estrategias de reproceso y extensión de vida de los reactores. Este análisis se ha centrado en explorar las ventajas y desventajas de reprocesado de combustible irradiado en un país con una “relativa” pequeña cantidad de reactores nucleares. Para el grupo de Europa se han tratado cuatro escenarios, incluyendo opciones de transmutación. Los escenarios incluyen los reactores actuales utilizando la tecnología reactor de agua ligera y ciclo abierto, un reemplazo total de los reactores actuales con reactores rápidos que queman combustible U-Pu MOX y dos escenarios del ciclo del combustible con transmutación de actínidos minoritarios en una parte de los reactores rápidos o en sistemas impulsados por aceleradores dedicados a transmutación. Finalmente, el capítulo 6 da las principales conclusiones obtenidas de esta tesis y los trabajos futuros previstos en el campo del análisis de ciclos de combustible nuclear. ABSTRACT The study of the nuclear fuel cycle requires versatile computational tools or “codes” to provide answers to the multicriteria problem of assessing current nuclear fuel cycles or the capabilities of different strategies and scenarios with potential development in a country, region or at world level. Moreover, the introduction of new technologies for reactors and industrial processes makes the existing codes to require new capabilities to assess the transition from current status of the fuel cycle to the more advanced and sustainable ones. Briefly, this thesis is focused in providing answers to the main questions about resources and economics in fuel cycle scenario analyses, in particular for the analysis of different fuel cycle scenarios with relative importance for Spain and Europe. The upgrade and development of new capabilities of the TR_EVOL code (Transition Evolution code) has been necessary to achieve this goal. This work has been developed in the Nuclear Innovation Program at CIEMAT since year 2010. This thesis is divided in 6 chapters. The first one gives an overview of the nuclear fuel cycle, its main stages and types currently used or in development for the future. Besides the sources of nuclear material that could be used as fuel (uranium and others) are also viewed here. A number of tools developed for the study of these nuclear fuel cycles are also briefly described in this chapter. Chapter 2 is aimed to give a basic idea about the cost involved in the electricity generation by means of the nuclear energy. The main classification of these costs and their estimations given by bibliography, which have been evaluated in this thesis, are presented. A brief description of the Levelized Cost of Electricity, the principal economic indicator used in this thesis, has been also included. Chapter 3 is focused on the description of the simulation tool TR_EVOL developed for the study of the nuclear fuel cycle. TR_EVOL has been designed to evaluate different options for the fuel cycle scenario. In particular, diverse nuclear power plants, having possibly different types of fuels and the associated fuel cycle facilities can be assessed. The TR_EVOL module for economic assessments provides the Levelized Cost of Electricity making use of the TR_EVOL mass balance output and four main sources of economic information. Furthermore, uncertainties assessment can be also carried out by the code. A cross checking process of the performance of the code has been accomplished and it is shown in Chapter 4. The process has been applied in four stages according to the most important features of TR_EVOL. Thus, the first stage has involved the mass balance of the current Spanish nuclear fuel cycle. The second stage has been focused in the isotopic composition of the mass flow using the fuel cycle defined in the EU project CP-ESFR. The last two stages have been aimed to validate the economic module. In the third stage, the main three generation costs (financial cost, O&M and fuel cost) have been assessed and compared to those obtained by ARCAS project, omitting the back-end costs. This last cost has been evaluated alone in the fourth stage, making use of some unit cost and parameters obtained from the bibliography. In Chapter 5 two groups of nuclear fuel cycle options with relevant importance for Spain and Europe are analyzed in economic and resources terms. For the Spanish case, two groups of fuel cycle scenarios have been simulated including reprocessing strategies and life extension of the current reactor fleet. This analysis has been focused on exploring the advantages and disadvantages of spent fuel reprocessing in a country with relatively small amount of nuclear power plants. For the European group, four fuel cycle scenarios involving transmutation options have been addressed. Scenarios include the current fleet using Light Water Reactor technology and open fuel cycle, a full replacement of the initial fleet with Fast Reactors burning U-Pu MOX fuel and two fuel cycle scenarios with Minor Actinide transmutation in a fraction of the FR fleet or in dedicated Accelerator Driven Systems. Finally, Chapter 6 gives the main conclusions obtained from this thesis and the future work foreseen in the field of nuclear fuel cycle analysis.