5 resultados para Negative probe detuning

em Universidad Politécnica de Madrid


Relevância:

80.00% 80.00%

Publicador:

Resumo:

With a thin coating of low-work-function material, thermionic emission in the cathodic segment of bare tethers might be much greater than orbital-motion-limited (OML) ion collection current. The space charge of the emitted electrons decreases the electric field that accelerates them outwards, and could even reverse it for high enough emission, producing a potential hollow. In this work, at the conditions of high bias and relatively low emission that make the potential monotonic, an asymptotic analysis is carried out, extending the OML ion-collection analysis to investigate the probe response due to electrons emitted by the negatively biased cylindrical probe. At given emission, the space charge effect from emitted electrons increases with decreasing magnitude of negative probe bias. Although emitted electrons present negligible space charge far away from the probe, their effect cannot be neglected in the global analysis for the sheath structure and two thin layers in between sheath and the quasineutral region. The space-charge-limited condition is located. It is found that thermionic emission increases the range of probe radius for OML validity and is greatly more effective than ion collection for cathodic contact of tethers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An asymptotic analysis of the Langmuir-probe problem in a quiescent, fully ionized plasma in a strong magnetic field is performed, for electron cyclotron radius and Debye length much smaller than probe radius, and this not larger than either ion cyclotron radius or mean free path. It is found that the electric potential, which is not confined to a sheath, controls the diffusion far from the probe; inside the magnetic tube bounded by the probe cross section the potential overshoots to a large value before decaying to its value in the body of the plasma. The electron current is independent of the shape of the body along the field and increases with ion temperature; due to the overshoot in the potential, (1) the current at negative voltages does not vary exponentially, (2) its magnitude is strongly reduced by the field, and (3) the usual sharp knee at space potential, disappears. In the regions of the C-V diagram studied the ion current is negligible or unaffected by the field. Some numerical results are presented.The theory, which fails beyond certain positive voltage, fields useful results for weak fields, too.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A theory is presented for an end effect in the current response of a highly negative, cylindrical Langmuir probe in a collisionless plasma flow. Under conditions where the ratio of probe radius to debye length is small and the ion-acoustic Mach number is large, the current exhibits a strong peak when the probe axis is brought into alignment with the flow direction. Closed formulas are given for the maximum and angular half-width of the peak, and universal graphical results are presented for the entire peak structure. The theory shows very good agreement with experimental data. The use of the end effect for diagnostic purposes, in particular, for the determination of the ion temperature, is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Collisional analysis of electron collection by a probe in a strongly magnetized, fully ionized plasma is carried out. A solution to the complete set of macroscopic equations with classical transport coefficients that is wholly consistent in the domain is determined; R and le are probe radius and electron gyroradius, respectively. If R2/le 2 is large compared with mi/3me probe large compared with ion gyroradius, ion–electron energy exchange—rather than electron heat diffusion—keeps electrons isothermal. For smaller probes at negative bias, however, electron cooling occurs in the plasma beyond the sheath, with a potential overshoot lying well away from it. The probe characteristic in the electron-retarding range may then mimic the characteristic for a two electron-temperature plasma and lead to an overestimate of electron temperature; the validity of these results for other transport models is discussed

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electron-retarding range of the current-voltage characteristic of a flat Langmuir probe perpendicular to a strong magnetic field in a fully ionized plasma is analysed allowing for anomalous (Bohm) cross-field transport and temperature changes in the collection process. With probe size and ion thermal gyroradius comparable, and smaller than the electron mean free path, there is an outer quasineutral region with ion viscosity determinant in allowing nonambipolar parallel and cross flow. A potential overshoot lying either at the base or inside the quasineutral region both makes ions follow Boltzmann's law at negative bias and extends the electron-retarding range to probe bias e(j)p ~ +2Too. Electron heating and cooling occur roughly at positive and negative bias, with a re-minimum around efa ~ - 2 7 ^ ; far from the probe heat conduction cools and heats electrons at and radially away from the probe axis, respectively. The potential overshoot with no thermal effects would reduce the electron current Ie, making the In Ie versus 4>p graph downwards-concave,but cooling further reduces Ie substantially, and may tilt the slope upwards past the temperature minimum. The domain of strict validity of our analysis is narrow in case of low ion mass (deuterium), breaking down with the ion Boltzmann law.