16 resultados para NV-homographs

em Universidad Politécnica de Madrid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Predictions about electric energy needs, based on current electric energy models, forecast that the global energy consumption on Earth for 2050 will double present rates. Using distributed procedures for control and integration, the expected needs can be halved. Therefore implementation of Smart Grids is necessary. Interaction between final consumers and utilities is a key factor of future Smart Grids. This interaction is aimed to reach efficient and responsible energy consumption. Energy Residential Gateways (ERG) are new in-building devices that will govern the communication between user and utility and will control electric loads. Utilities will offer new services empowering residential customers to lower their electric bill. Some of these services are Smart Metering, Demand Response and Dynamic Pricing. This paper presents a practical development of an ERG for residential buildings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extended 3D distributed model based on distributed circuit units for the simulation of triple‐junction solar cells under realistic conditions for the light distribution has been developed. A special emphasis has been put in the capability of the model to accurately account for current mismatch and chromatic aberration effects. This model has been validated, as shown by the good agreement between experimental and simulation results, for different light spot characteristics including spectral mismatch and irradiance non‐uniformities. This model is then used for the prediction of the performance of a triple‐junction solar cell for a light spot corresponding to a real optical architecture in order to illustrate its suitability in assisting concentrator system analysis and design process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here, a novel and efficient strategy for moving object detection by non-parametric modeling on smart cameras is presented. Whereas the background is modeled using only color information, the foreground model combines color and spatial information. The application of a particle filter allows the update of the spatial information and provides a priori information about the areas to analyze in the following images, enabling an important reduction in the computational requirements and improving the segmentation results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A video-aware unequal loss protection (ULP) system for protecting RTP video streaming in bursty packet loss networks is proposed. Just considering the relevance of the frame, the state of the channel and the bitrate constraints of the protection bitstream, our algorithm selects in real time the most suitable frames to be protected through forward error correction (FEC) techniques. It benefits from a wise RTP encapsulation that allows working at a frame level without requiring any further process than that of parsing RTP headers, so it is perfectly suitable to be included in commercial transmitters. The simulation results show how our proposed ULP technique outperforms non-smart schemes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advances in solid-state lighting have overcome common limitations on optical wireless such as power needs due to light dispersion. It's been recently proposed the modification of lamp's drivers to take advantages of its switching behaviour to include data links maintaining the illumination control they provide. In this paper, a remote access application using visible light communications is presented that provides wireless access to a remote computer using a touchscreen as user interface

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An infrared optical wireless system is presented, consisting on autonomous remote nodes communicating with a central node. The network is designed for telecommand/telemetry purposes, comprising a large number of nodes at a low data rate. Simultaneous access is granted by using CDMA techniques, and an appropriate selection of the code family can also keep power consumption to a minimum

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we show that the effect of jitter due to driver and LED is the limiting factor in the baud rate in L-PPM formats for VLC systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multijunction solar cells present a certain reflectivity on its surface that lowers its light absorption. This reflectivity produces a loss in electrical efficiency and thus a loss in global energy production for CPV systems. We present here an optical design for recovering this portion of reflected light, and thus leading to a system efficiency increase. This new design is based on an external confinement cavity, an optical element able to redirect the light reflected by the cell towards its surface again. We have proven the excellent performance of these cavities integrated in CPV modules offering outstanding results: 33.2% module electrical efficiency @Tcell  =  25 °C and relative efficiency and Isc gains of over 6%

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Fresnel Köhler (FK) concentrator was first presented in 2008. Since then, various CPV companies have adopted this technology as base for their future commercial product. The key for this rapid penetration is a mixture of simplicity (the FK is essentially a Fresnel lens concentrator, a technology that dominates the market) and excellent performance: high concentration without giving up large manufacturing∕aiming tolerances, enabling high efficiency even at the array level. All these features together have a great potential to lower energy costs. This work shows recent results and progress regarding this device, covering new design features, measurements and tests along with first performance achievements at the array level (pilot 6.5 Kwp plant). The work also discusses the potential impact of the FK enhanced performance on the Levelized Cost Of Electricity (LCOE)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Getting a lower energy cost has always been a challenge for concentrated photovoltaic. The FK concentrator enhances the performance (efficiency, acceptance angle and manufacturing tolerances) of the conventional CPV system based on a Fresnel primary stage and a secondary lens, while keeping its simplicity and potentially low‐cost manufacturing. At the same time F‐XTP (Fresnel lens+reflective prism), at the first glance has better cost potential but significantly higher sensitivity to manufacturing errors. This work presents comparison of these two approaches applied to two main technologies of Fresnel lens production (PMMA and Silicone on Glass) and effect of standard deformations that occur under real operation conditions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present an adaptive multi-camera system for real time object detection able to efficiently adjust the computational requirements of video processing blocks to the available processing power and the activity of the scene. The system is based on a two level adaptation strategy that works at local and at global level. Object detection is based on a Gaussian mixtures model background subtraction algorithm. Results show that the system can efficiently adapt the algorithm parameters without a significant loss in the detection accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyze the effect of packet losses in video sequences and propose a lightweight Unequal Error Protection strategy which, by choosing which packet is discarded, reduces strongly the Mean Square Error of the received sequence

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multimedia distribution through wireless networks in the home environment presents a number of advantages which have fueled the interest of industry in recent years, such as simple connectivity and data delivery to a variety of devices. Together with High-Definition (HD) contents, multimedia wireless networks have been proposed for several applications, such as IPTV and Digital TV distribution for multiple devices in the home environment. For these scenarios, we propose a multicast distribution system for High-Definition video over 802.11 wireless networks based on rate-limited packet retransmission. We develop a limited rate ARQ system that retransmits packets according to the importance of their content (prioritization scheme) and according to their delay limitations (delay control). The performance of our proposed ARQ system is evaluated and compared with a similarly rate-limited ARQ algorithm. The results show a higher packet recovery rate and improvements in video quality for our proposed system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabajo presenta un estudio de campo sobre confort térmico basado en la concepción adaptativa, para la determinación de las temperaturas y rangos de confort térmico de sujetos habituados a espacios enfriados mecánicamente en viviendas con aire acondicionado (AA) en el clima cálido y húmedo de la ciudad de Maracaibo (Venezuela) y las consecuentes implicaciones energéticas que tiene la satisfacción de esa demanda de confortabilidad en el sector residencial de la ciudad. Para la estimación de la temperatura de confort (Tc) y el rango de temperaturas de confort se aplican diferentes metodologías de análisis estadístico, las cuales son comparadas con las respectivas calculadas con el índice PMV; se analizan también otros aspectos asociados a la confortabilidad térmica, tales como las respuestas en las diferentes escalas de valoración de la confortabilidad, las preferencias, experiencias y expectativas térmicas de los sujetos. Las implicaciones energéticas se determinan en base al consumo de la energía eléctrica residencial debido exclusivamente a la variación de la Tc, entre la obtenida inicialmente en espacios naturalmente ventilados (NV) en Maracaibo (Bravo y Gonzalez 2001a) y la determinada ahora en espacios con AA. Para ello, se utiliza una metodología que es el resultado de la modificación parcial de la propuesta por Yamtraipat et al (2006). Entre los resultados y conclusiones derivadas de este estudio se encuentra que el 57 % de las personas prefieren las mismas condiciones confortables experimentadas en los ambientes con AA y solamente un 30 % prefieren experimentar ambientes ligeramente fríos y ligeramente calientes. Mientras tanto, las estimaciones de la Tc, y el respectivo rango, varían de acuerdo a la metodología empleada. Con la convencional metodología adaptativa, la Tc se estima en 25 °C en un amplio rango de 6 °C, entre 22 °C y 28 °C; mientras que con la metodología denominada “método de los promedios de los intervalos de las sensaciones térmicas” (Gómez-Azpeitia et al, 2007), la misma Tc se estima en 24 °C, en un rango estrecho de 22,5 °C a 25,5 °C y en un rango ampliado de 21 °C a 27 °C (amplitud 6 °C), donde se encuentran las tres cuartas partes de las personas del estudio. Ambas Tc son muy próximas a la temperatura operativa optima de 24,5 °C (rango de 23 °C a 26 °C) establecida por las normas internacionales ISO 7730:1994 y ASHRAE 55:1992 para el verano en climas templados. Sin embargo, la Tc estimada con los valores de PMV resulta ser superior en 1 °C y 2 °C a la Tc estimada con la metodología adaptativa (25 °C) y con el metodo de los promedios de los intervalos (24 °C), respectivamente. Con la metodología aplicada y la muestra del estudio se estima que de haberse registrado una Tbsint igual o próxima a 28 C (equivalente a la Tc en espacios NV en Maracaibo) en todos los espacios medidos (con Tbsint entre 19 C y 29 C), el ahorro total de la energía anual seria de 1.648,1 GWh en un ano respecto al consumo de AA en el año 2007 (2.522,3 GWh en un ano), mientras que el ahorro de energía asumiendo Tbsint de 24 C y de 25 C, resultan en 651,9 GWh en un ano y 425,7 GWh en un ano, respectivamente. Esto significa respectivos consumos adiciones de energía eléctrica equivalentes al 60,4 % y 74,2 %. Finalmente, los hábitos o conductas adoptadas por las personas de este estudio, sumado a las predominantes manifestaciones de confortabilidad en ambientes enfriados mecánicamente, redundan en mayores adaptaciones a condiciones de frio y exigencias de temperaturas de confort más bajas, con su consecuente consumo energético para proveerlas. ABSTRACT This investigation presents a study on thermal comfort following the adaptive approach for the determination of the thermal comfort temperatures and ranges of subjects accustomed to mechanically refrigerated spaces in dwellings with air conditioning (AA) systems in the hot and humid weather of the city of Maracaibo (Venezuela) and the ensuing energy use implications it has on the satisfaction of such demand of comfortability in the residential sector of the city. For the estimation of the comfort temperature (Tc) and the range of comfort temperatures different statistical analysis methodologies were used, which are then compared to the respective values calculated with the PMV index, also discusses other aspects related with thermal comfortability were analyzed, such as the responses on the different scales of perception of thermal comfortability, preferences, experiences and expectations of the analyzed subjects. The energetic implications are determined through the residential energy consumption related exclusively with the variation of the Tc between the originally calculated for naturally ventilated (NV) spaces in Maracaibo (Bravo y Gonzalez 2001a) and the one calculated on the present study with AA. For this, a new methodology was developed by partially modifying the Yamtraipat et al (2006) proposal. Among the results and conclusions of this study are that 57 % of the studied subjects prefer the same comfortable conditions experienced on AA environments and only a 30 % prefer to experience slightly cooler or warmer environments. Also, estimations of the Tc and its respective range vary according to the used methodology. With the conventional adaptive methodology, the Tc is estimated in 25 °C with a wide range of 6 °C, between 22 °C and 28 °C, while using the “thermal sensation intervals averages method” (Gomez-Azpeitia et al, 2007) the Tc is estimated in 24 °C on a narrow range between 22.5 °C and 25.5 °C and a widened range of 21 °C to 27 °C (6 °C in amplitude), a range where . of the studied subjects are located. Both Tc are very close to the optimum operation temperature of 24.5 °C (with a range between 23 °C and 26 °C) established on the ISO 7730:1994 and ASHRAE 55:1992 international norms for the summer on warm climates. However, the estimated Tc with the PMV indexes results to be 1 °C and 2 °C above the Tc estimated with the adaptive methodology (25 °C) and the thermal sensation intervals averages method (24 °C), respectively. With the applied methodology and this study sample, its estimated that if a Tbsint equal or close to 28 °C (equivalent to the Tc in NV spaces in Maracaibo) was registered in all measured spaces (with Tbsint between 19 °C and 29 °C) the total yearly energy savings would be of 1.648,1 GWh in a year with respect to the AA consumption in the year 2007 (2.522.3 GWh in a year), while the energy savings assuming a Tbinst of 24 °C and 25 °C result in 651.9 GWh and 425.7 Gwh in a year, respectively. This means that the respective additional electrical energy consumption amount to 60.4 % and 74.2 %, respectively. Finally, the habits or behaviors adopted by the subjects analyzed on this study, added to the predominant manifestations of comfortability in mechanically refrigerated environments result in greater adaptations to colder conditions and lower thermal comfort temperature demands, with the consequential increase in power consumption to meet them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A real-time surveillance system for IP network cameras is presented. Motion, part-body, and whole-body detectors are efficiently combined to generate robust and fast detections, which feed multiple compressive trackers. The generated trajectories are then improved using a reidentification strategy for long term operation.