2 resultados para Monitoring. beach profiles. Ponta Negra. Sedimentology. Hydrodynamics

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Equations for extreme runup worked out from several experimental studies are compared. Infragraviatory oscillations dominate the swash in a dissipative state but not in intermediate - reflective states. Therefore two kinds of equation depending on either significant wave height, H-0, or the Iribarren number, xi(0), should be used. Through a sand bed physical model with a uniform sand bed slope, equations are proposed for both beach states, and results are compared with precedent field and physical model experiments. Once the equations are chosen, the time-longshore variability in a medium - long term time scale of the foreshore slope is evaluated in two extreme cases relating to the Spanish coast. The Salinas beach on the North coast (Bay of Biscay) displayed a permanent dissipative beach state with small variations in the beach foreshore slope both along the shore and in time, so foreshore slope deviations in a medium-long term period were irrelevant and extreme runup is predicted with the wave height worked out from the design return period. Peniscola beach on the East coast (Mediterranean sea) displayed an intermediate state. If only time variations are analysed, variations in determining extreme runup are irrelevant. In contrast, significant differences were found when the longshore variations were studied in this Mediterranean beach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent research has shown large differences between the expected and the actual energy consumption in buildings. The differences have been attributed partially, to the assumptions made during the design phase of buildings when simulation methods are employed. More accurate occupancy profiles on building operation could help to carry out more precise building performance calculations. This study focuses on the post-occupancy evaluation of two apartments, one renovated and one non renovated, in Madrid within the same building complex. The aim of this paper is to present an application of the mixed-methods methodology (Creswell, 2007) to assess thermal comfort and occupancy practices used in the case studies, and to discuss the shortcomings and opportunities associated with it. The mixed-methods methodology offers strategies for integrating qualitative and quantitative methods to investigate complex phenomena. This approach is expected to contribute to the growing knowledge of occupants’ behaviour and building performance by explaining the differences observed between energy consumption and thermal comfort in relation to people’s saving and comfort practices and the related experiences, preferences and values.