5 resultados para Mm3 Force-field
em Universidad Politécnica de Madrid
Resumo:
This paper presents the development of a new parallel robot designed for helping with bone milling surgeries. The robot is a small modular wrist with 2 active degrees of freedom, and it is proposed to be used as an orientation device located at the end of a robotic arm designed for bone milling processes. A generic kinematic geometry is proposed for this device. This first article shows the developments on the workspace optimization and the analysis of the force field required to complete a reconstruction of the inferior jawbone. The singularities of the mechanism are analyzed, and the actuator selection is justified with the torque requirements and the study of the force space. The results obtained by the simulations allow building a first prototype using linear motors. Bone milling experiment video is shown as additional material.
Resumo:
El estudio de la influencia de perturbaciones de distinta naturaleza en configuraciones de puentes líquidos apoyados en dos discos coaxiales en rotación encuentra una importante motivación en el uso de dicha configuración en la fabricación de cristales semiconductores ultra-puros por la denominada técnica de zona flotante, en la que la rotación de los discos se utiliza para alcanzar temperaturas uniformes. El presente estudio muestra los resultados obtenidos mediante la aplicación de un método numérico en el análisis de la estabilidad de puentes líquidos en isorrotación sometidos al efecto de una fuerza axial uniforme (gravedad axial) y una excentricidad entre el eje de giro y el eje de los discos. Se analiza el efecto de la aplicación de estos factores tanto de forma conjunta como por separado. Aunque existen numerosos estudios previos sobre puentes líquidos sometidos a diversos efectos, el análisis del efecto combinado de la rotación con excentricidad y gravedad axial no ha sido realizado con anterioridad. Este estudio permite además entender los resultados del experimento a bordo de la misión TEXUS-23, en el que un puente líquido sujeto entre dos discos circulares y coaxiales es sometido al efecto de una rotación creciente en torno a un eje desplazado respecto al eje de los discos. Aunque en el experimento no se impone una fuerza axial controlada, la desestabilización y rotura del puente se produce de forma notablemente asimétrica, lo que no puede ser explicado con los estudios precedentes y sugiere una posible presencia de una aceleración axial residual. Se ha desarrollado por tanto un método de análisis de imágenes que permite comparar las formas obtenidas en el experimento con las calculadas numéricamente. En este estudio se muestran los detalles del procesado realizado en las imágenes de la misión TEXUS-23, y los resultados de su comparación con el análisis numérico, que permiten determinar el valor de la gravedad axial que mejor reproduce los resultados del experimento. Estos resultados ponen de manifiesto la importancia del conocimiento y la modelización de efectos cuya presencia (intencionada o no) afectan de forma visible a la estabilidad y la morfología de los puentes líquidos. ABSTRACT The study of the influence of various disturbances in configurations consisting of a liquid bridge supported by two co-axial disks in rotation has an important motivation in the use of this configuration in the fabrication of ultrapure semiconductor crystals via the so-called floating zone technique, in which the rotation of the disks is used to achieve a uniform temperature field. The present study shows the results obtained through the application of a numerical method in the analysis of the stability of liquid bridges in isorotation under the effect of a uniform axial force field (axial gravity) and an offset between the rotation axis and the axis of the supporting disks (eccentricity). The analysis studies the effect of both the combined and separate application of these factors. Although there are numerous studies on liquid bridges subject to various effects, the analysis of the combined effect of rotation with eccentricity and axial gravity has not been done before. Furthermore, this study allows us to understand the results from the experiment aboard the TEXUS-23 mission, in which a liquid bridge supported between two circular-shaped, co-axial disks is subject to the effect of an increasing rotation around an axis with an offset with respect to the axis of the disks. Although the experiment conditions do not include a controlled axial force field, the instability and breakage of the bridge occurs with a marked asymmetry, which cannot be explained by previous studies and suggests the possible presence of a residual axial gravity. Therefore, an image analysis method has been developed which allows to compare the shapes obtained in the experiment with those calculated with the numerical method. This study shows the details of the processing performed on the images from the TEXUS-23 mission and the results from their comparison with the numerical analysis, which allow to determine the axial gravity value which best recovers the experimental results. These results highlight the importance of the understanding and modelling of effects which, when present (intentionally or not), noticeably affect the stability and shape of the liquid bridges.
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
A kinetic approach is used to develop a theory of electrostatic probes in a fully ionized plasma in the presence of a magnetic field. A consistent asymptotic expansion is obtained assuming that the electron Larmor radius is small compared to the radius of the probe. The order of magnitude of neglected terms is given. It is found that the electric potential within the tube of force defined by the cross section of the probe decays non-mono tonic ally from the probe; this bump disappears at a certain probe voltage and the theory is valid up to this voltage. The transition region, which extends beyond plasma potential, is not exponential. The possible saturation of the electron current is discussed. Restricted numerical results are given; they seem to be useful for weaker magnetic fields down to the zero-field limit. Extensions of the theory a r e considered.
Resumo:
An eiectrodynamic Tether is a long thin conductive string deployed from a spacecraft. A part of the ED tether near one end, which is rendered positive by the Electromotive force (EMF)along the tether, collects electrons from the ambient plasma. In the frame of reference moving with theter, ions flow toward the tether, get deflected near the tether by its high positive potential and create a wake. Due to the asymmetry of plasma distribution and the weak but significant Geomagnetic field, the conventional probe theory becomes almost inapplicable. Computational work for the prediction of current collection is thus necessiated.. In this paper, we analyze effects of magnetic field on velocity distribution funtion at a point that is far from the tether, and discuss a new way to treat electrons at computational boundary. Three cases with different magnetic field are simulated and compiled so as to provide a part of the pre-flight prediction of the space experiment by NASA ProSEDS, which is planned September 2002.