13 resultados para Metallic nanocontacts

em Universidad Politécnica de Madrid


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present and discuss an algorithm to identify and characterize the long icosahedral structures (staggered pentagonal nanowires with 1-5-1-5 atomic structure) that appear in Molecular Dynamics simulations of metallic nanowires of different species subjected to stretching. The use of this algorithm allows the identification of pentagonal rings forming the icosahedral structure as well as the determination of its number np , and the maximum length of the pentagonal nanowire Lpm. The algorithm is tested with some ideal structures to show its ability to discriminate between pentagonal rings and other ring structures. We applied the algorithm to Ni nanowires with temperatures ranging between 4K and 865K, stretched along the [111], [100] and [110] directions. We studied statistically the formation of pentagonal nanowires obtaining the distributions of length Lpm and number of rings np as function of the temperature. The Lpm distribution presents a peaked shape, with peaks located at fixed distances whose separation corresponds to the distance between two consecutive pentagonal rings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analysis of the transport of electric current in a jet of an electrically conducting liquid discharging from a metallic tube into a gas or a vacuum, and subject to an electric field due to a high voltage applied between the tube and a far electrode. The flow, the surface charge and the electric field are computed in the current transfer region of the jet, where conduction current in the liquid becomes surface current due to the convection of electric charge accumulated at its surface. The electric current computed as a function of the flow rate of the liquid injected through the tube increases first as the square root of this flow rate, levels to a nearly constant value when the flow rate is increased and finally sets to a linear increase when the flow rate is further increased. The current increases linearly with the applied voltage at small and moderate values of this variable, and faster than linearly at high voltages. The characteristic length and structure of the current transfer region are determined. Order-of-magnitude estimates for jets which are only weakly stretched by the electric stresses are worked out that qualitatively account for some of the numerical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have dealt with the possibility of increasing light absorption by using the so-called electric field enhancement taking place within the grooves of metallic gratings. In order to evaluate the potential improvements derived from the absorption increase, we employ a simplified model to analyze the low-injection behaviour of a solar cell with a metallic grating back-reflector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser shock processing (LSP) is being increasingly applied as an effective technology for the improvement of metallic materials surface properties in different types of components as a means of enhancement of their corrosion and fatigue life behavior. As reported in previous contributions by the authors, a main effect resulting from the application of the LSP technique consists on the generation of relatively deep compression residual stresses field into metallic alloy pieces allowing an improved mechanical behaviour, explicitly the life improvement of the treated specimens against wear, crack growth and stress corrosion cracking. Additional results accomplished by the authors in the line of practical development of the LSP technique at an experimental level (aiming its integral assessment from an interrelated theoretical and experimental point of view) are presented in this paper. Concretely, follow-on experimental results on the residual stress profiles and associated surface properties modification successfully reached in typical materials (especially Al and Ti alloys) under different LSP irradiation conditions are presented along with a practical correlated analysis on the protective character of the residual stress profiles obtained under different irradiation strategies and the evaluation of the corresponding induced properties as material specific volume reduction at the surface, microhardness and wear resistance. Additional remarks on the improved character of the LSP technique over the traditional “shot peening” technique in what concerns depth of induced compressive residual stresses fields are also made through the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

•Introduction •Process Experimental Setup •Experimental Procedure •Experimental Results for Al2024 - T351, Ti6Al4V and AISI 316L - Surface Roughness and Compactation - Residual stresses - Tensile Strength - Fatigue Life •Discussion and Outlook - Prospects for technological applications of LSP

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Outline: • Introduction • Process Experimental Setup • Experimental Procedure • Experimental Results for Al2024-T351 and Ti6Al4V - Residual stresses - Tensile Strength - Fatigue Life • Discussion and Outlook - Prospects for technological applications of LSP

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser shock processing (LSP) is increasingly applied as an effective technology for the improvement of metallic materials mechanical properties in different types of components as a means of enhancement of their fatigue life behavior. As reported in previous contributions by the authors, a main effect resulting from the application of the LSP technique consists on the generation of relatively deep compression residual stresses fields into metallic components allowing an improved mechanical behaviour, explicitly the life improvement of the treated specimens against wear, crack growth and stress corrosion cracking. Additional results accomplished by the authors in the line of practical development of the LSP technique at an experimental level (aiming its integral assessment from an interrelated theoretical and experimental point of view) are presented in this paper. Concretely, experimental results on the residual stress profiles and associated mechanical properties modification successfully reached in typical materials under different LSP irradiation conditions are presented. In this case, the specific behavior of a widely used material in high reliability components (especially in nuclear and biomedical applications) as AISI 316L is analyzed, the effect of possible “in-service” thermal conditions on the relaxation of the LSP effects being specifically characterized. I.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser shock processing (LSP) is being increasingly applied as an effective technology for the improvement of metallic materials mechanical and surface properties in different types of components as a means of enhancement of their corrosion and fatigue life behavior. As reported in previous contributions by the authors, a main effect resulting from the application of the LSP technique consists on the generation of relatively deep compression residual stresses field into metallic alloy pieces allowing an improved mechanical behaviour, explicitly the life improvement of the treated specimens against wear, crack growth and stress corrosion cracking. Additional results accomplished by the authors in the line of practical development of the LSP technique at an experimental level (aiming its integral assessment from an interrelated theoretical and experimental point of view) are presented in this paper. Concretely, follow-on experimental results on the residual stress profiles and associated surface properties modification successfully reached in typical materials (especially Al and Ti alloys characteristic of high reliability components in the aerospace, nuclear and biomedical sectors) under different LSP irradiation conditions are presented along with a practical correlated analysis on the protective character of the residual stress profiles obtained under different irradiation strategies. Additional remarks on the improved character of the LSP technique over the traditional “shot peening” technique in what concerns depth of induced compressive residual stresses fields are also made through the paper

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents a novel temperature sensor, which consists of an interdigitated comb electrode structure with a micrometric-scale size, nanometric metallic layer, and nematic liquid crystal (NLC) film. This sensor exploits the permittivity dependence of the NLC with temperature and principle of electrical conductivity above the percolation threshold in thin film metallic layers. The latter has been demonstrated to increase the temperature sensitivity considerably. The high impedance input reduces the power dissipation, and the high enough voltage output makes it easy to measure the output signal with high precision. The operation principle and fabrication process as well as the characterization of the temperature sensor are presented. Experimental results show that the device offers a sensitivity of 9 mV/°C and is dependent on the applied voltage. This is six times greater than the same structure without the use of a nanometric layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first demonstration of fabrication of submicron lateral resolution molecularly imprinted polymer (MIP) patterns by photoinduced local polymerization within metal subwavelength apertures is reported. The size of the photopolymerized MIP features is finely tuned by the dose of 532 nm radiation. Rhodamine 123 (R123) has been selected as a fluorescent model template to prove the recognition capability of the MIP nanostructures, which has been evaluated by fluorescence lifetime imaging microscopy (FLIM) with single photon timing measurements. The binding selectivity provided by the imprinting effect has been confirmed in the presence of compounds structurally related to R123. These results pave the way to the development of nanomaterial architectures with biomimetic artificial recognition properties for environmental, clinical and food testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser shock processing (LSP) is increasingly applied as an effective technology for the improvement of metallic materials mechanical properties in different types of components as a means of enhancement of their fatigue life behavior. As reported in previous contributions by the authors, a main effect resulting from the application of the LSP technique consists on the generation of relatively deep compression residual stresses fields into metallic components allowing an improved mechanical behaviour, explicitly the life improvement of the treated specimens against wear, crack growth and stress corrosion cracking. Additional results accomplished by the authors in the line of practical development of the LSP technique at an experimental level (aiming its integral assessment from an interrelated theoretical and experimental point of view)are presented in this paper. Concretely, experimental results on the residual stress profiles and associated mechanical properties modification successfully reached in typical materials under different LSP irradiation conditions are presented. In this case, the specific behavior of a widely used material in high reliability components (especially in nuclear and biomedical applications) as AISI 316L is analyzed, the effect of possible “in-service” thermal conditions on the relaxation of the LSP effects being specifically characterized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser peening has recently emerged as a useful technique to overcome detrimental effects associated to another well-known surface modification processes such as shot peening or grit blasting used in the biomedical field. It is worth to notice that besides the primary residual stress effect, thermally induced effects might also cause subtle surface and subsurface microstructural changes that might influence corrosion resistance. Moreover, since maximum loads use to occur at the surface, they could also play a critical role in the fatigue strength. In this work, plates of Ti-6Al-4V alloy of 7 mm in thickness were modified by laser peening without using a sacrificial outer layer. Irradiation by a Q-switched Nd-YAG laser (9.4 ns pulse length) working in fundamental harmonic at 2.8 J/pulse and with water as confining medium was used. Laser pulses with a 1.5 mm diameter at an equivalent overlapping density (EOD) of 5000 cm-2 were applied. Attempts to analyze the global induced effects after laser peening were addressed by using the contacting and non-contacting thermoelectric power (TEP) techniques. It was demonstrated that the thermoelectric method is entirely insensitive to surface topography while it is uniquely sensitive to subtle variations in thermoelectric properties, which are associated with the different material effects induced by different surface modification treatments. These results indicate that the stress-dependence of the thermoelectric power in metals produces sufficient contrast to detect and quantitatively characterize regions under compressive residual stress based on their thermoelectric power contrast with respect to the surrounding intact material. However, further research is needed to better separate residual stress effects from secondary material effects, especially in the case of low-conductivity engineering materials like titanium alloys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En los últimos años, y asociado al desarrollo de la tecnología MEMS, la técnica de indentación instrumentada se ha convertido en un método de ensayo no destructivo ampliamente utilizado para hallar las características elástico-plásticas de recubrimientos y capas delgadas, desde la escala macroscópica a la microscópica. Sin embargo, debido al complejo mecanismo de contacto debajo de la indentación, es urgente proponer un método más simple y conveniente para obtener unos resultados comparables con otras mediciones tradicionales. En este estudio, el objetivo es mejorar el procedimiento analítico para extraer las propiedades elástico-plásticas del material mediante la técnica de indentación instrumentada. La primera parte se centra en la metodología llevada a cabo para medir las propiedades elásticas de los materiales elásticos, presentándose una nueva metodología de indentación, basada en la evolución de la rigidez de contacto y en la curva fuerza-desplazamiento del ensayo de indentación. El método propuesto permite discriminar los valores de indentación experimental que pudieran estar afectados por el redondeo de la punta del indentador. Además, esta técnica parece ser robusta y permite obtener valores fiables del modulo elástico. La segunda parte se centra en el proceso analítico para determinar la curva tensión-deformación a partir del ensayo de indentación, empleando un indentador esférico. Para poder asemejar la curva tension-deformación de indentación con la que se obtendría de un ensayo de tracción, Tabor determinó empíricamente un factor de constricción de la tensión () y un factor de constricción de la deformación (). Sin embargo, la elección del valor de y  necesitan una derivación analítica. Se describió analíticamente una nueva visión de la relación entre los factores de constricción de tensión y la deformación basado en la deducción de la ecuación de Tabor. Un modelo de elementos finitos y un diseño experimental se realizan para evaluar estos factores de constricción. A partir de los resultados obtenidos, las curvas tension-deformación extraidas de los ensayos de indentación esférica, afectadas por los correspondientes factores de constricción de tension y deformación, se ajustaron a la curva nominal tensión-deformación obtenida de ensayos de tracción convencionales. En la última parte, se estudian las propiedades del revestimiento de cermet Inconel 625-Cr3C2 que es depositado en el medio de una aleación de acero mediante un láser. Las propiedades mecánicas de la matriz de cermet son estudiadas mediante la técnica de indentación instrumentada, haciendo uso de las metodologías propuestas en el presente trabajo. In recent years, along with the development of MEMS technology, instrumented indentation, as one type of a non-destructive measurement technique, is widely used to characterize the elastic and plastic properties of metallic materials from the macro to the micro scale. However, due to the complex contact mechanisms under the indentation tip, it is necessary to propose a more convenient and simple method of instrumented indention to obtain comparable results from other conventional measurements. In this study, the aim is to improve the analytical procedure for extracting the elastic plastic properties of metallic materials by instrumented indentation. The first part focuses on the methodology for measuring the elastic properties of metallic materials. An alternative instrumented indentation methodology is presented. Based on the evolution of the contact stiffness and indentation load versus the depth of penetration, the possibility of obtaining the actual elastic modulus of an elastic-plastic bulk material through instrumented sharp indentation tests has been explored. The proposed methodology allows correcting the effect of the rounding of the indenter tip on the experimental indentation data. Additionally, this technique does not seem too sensitive to the pile-up phenomenon and allows obtaining convincing values of the elastic modulus. In the second part, an analytical procedure is proposed to determine the representative stress-strain curve from the spherical indentation. Tabor has determined the stress constraint factor (stress CF), and strain constraint factor (strain CF), empirically but the choice of a value for and is debatable and lacks analytical derivation. A new insight into the relationship between stress and strain constraint factors is analytically described based on the formulation of Tabor’s equation. Finite element model and experimental tests have been carried out to evaluate these constraint factors. From the results, representative stress-strain curves using the proposed strain constraint factor fit better with the nominal stress-strain curve than those using Tabor’s constraint factors. In the last part, the mechanical properties of an Inconel 625-Cr3C2 cermet coating which is deposited onto a medium alloy steel by laser cladding has been studied. The elastic and plastic mechanical properties of the cermet matrix are studied using depth-sensing indentation (DSI) on the micro scale.