6 resultados para Metallic Structures

em Universidad Politécnica de Madrid


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ultrasonic transducers have often been used in the development of sensory systems for robotics applications. In most cases, these sensory systems are based on the determination of times of flight for signals from every transducer. In this work we have used piezoresistive and piezoelectric materials to measure the instant and position collision in metallic structures by using the difference of the times of propagation of an acoustic wave when it is produced over a ferromagnetic (iron, steel or another material) based structure. An immediate application of the proposed method is the detection and location of impacts over the metallic links of an industrial robot or the collision position in a metallic structure for an automated inspection

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La mayoría de las estructuras de hormigón pretensadas construidas en los últimos 50 años han demostrado una excelente durabilidad cuando su construcción se realiza atendiendo las recomendaciones de un buen diseño así como una buena ejecución y puesta en obra de la estructura. Este hecho se debe en gran parte al temor que despierta el fenómeno de la corrosión bajo tensión típico de las armaduras de acero de alta resistencia. Menos atención se ha prestado a la susceptibilidad a la corrosión bajo tensión de los anclajes de postensado, posiblemente debido a que se han reportado pocos casos de fallos catastróficos. El concepto de Tolerancia al Daño y la Mecánica de la Fractura en estructuras de Ingeniería Civil ha empezado a incorporarse recientemente en algunas normas de diseño y cálculo de estructuras metálicas, sin embargo, aún está lejos de ser asimilado y empleado habitualmente por los ingenieros en sus cálculos cuando la ocasión lo requiere. Este desconocimiento de los aspectos relacionados con la Tolerancia al Daño genera importantes gastos de mantenimiento y reparación. En este trabajo se ha estudiado la aplicabilidad de los conceptos de la Mecánica de la Fractura a los componentes de los sistemas de postensado empleados en ingeniería civil, empleándolo para analizar la susceptibilidad de las armaduras activas frente a la corrosión bajo tensiones y a la pérdida de capacidad portante de las cabezas de anclajes de postensado debido a la presencia de defectos. Con este objeto se han combinado tanto técnicas experimentales como numéricas. Los defectos superficiales en los alambres de pretensado no se presentan de manera aislada si no que existe una cierta continuidad en la dirección axial así como un elevado número de defectos. Por este motivo se ha optado por un enfoque estadístico, que es más apropiado que el determinístico. El empleo de modelos estadísticos basados en la teoría de valores extremos ha permitido caracterizar el estado superficial en alambres de 5,2 mm de diámetro. Por otro lado la susceptibilidad del alambre frente a la corrosión bajo tensión ha sido evaluada mediante la realización de una campaña de ensayos de acuerdo con la actual normativa que ha permitido caracterizar estadísticamente su comportamiento. A la vista de los resultados ha sido posible evaluar como los parámetros que definen el estado superficial del alambre pueden determinar la durabilidad de la armadura atendiendo a su resistencia frente a la corrosión bajo tensión, evaluada mediante los ensayos que especifica la normativa. En el caso de las cabezas de anclaje de tendones de pretensado, los defectos se presentan de manera aislada y tienen su origen en marcas, arañazos o picaduras de corrosión que pueden producirse durante el proceso de fabricación, transporte, manipulación o puesta en obra. Dada la naturaleza de los defectos, el enfoque determinístico es más apropiado que el estadístico. La evaluación de la importancia de un defecto en un elemento estructural requiere la estimación de la solicitación local que genera el defecto, que permite conocer si el defecto es crítico o si puede llegar a serlo, si es que progresa con el tiempo (por fatiga, corrosión, una combinación de ambas, etc.). En este trabajo los defectos han sido idealizados como grietas, de manera que el análisis quedara del lado de la seguridad. La evaluación de la solicitación local del defecto ha sido calculada mediante el empleo de modelos de elementos finitos de la cabeza de anclaje que simulan las condiciones de trabajo reales de la cabeza de anclaje durante su vida útil. A partir de estos modelos numéricos se ha analizado la influencia en la carga de rotura del anclaje de diversos factores como la geometría del anclaje, las condiciones del apoyo, el material del anclaje, el tamaño del defecto su forma y su posición. Los resultados del análisis numérico han sido contrastados satisfactoriamente mediante la realización de una campaña experimental de modelos a escala de cabezas de anclaje de Polimetil-metacrilato en los que artificialmente se han introducido defectos de diversos tamaños y en distintas posiciones. ABSTRACT Most of the prestressed concrete structures built in the last 50 years have demonstrated an excellent durability when they are constructed in accordance with the rules of good design, detailing and execution. This is particularly true with respect to the feared stress corrosion cracking, which is typical of high strength prestressing steel wires. Less attention, however, has been paid to the stress corrosion cracking susceptibility of anchorages for steel tendons for prestressing concrete, probably due to the low number of reported failure cases. Damage tolerance and fracture mechanics concepts in civil engineering structures have recently started to be incorporated in some design and calculation rules for metallic structures, however it is still far from being assimilated and used by civil engineers in their calculations on a regular basis. This limited knowledge of the damage tolerance basis could lead to significant repair and maintenance costs. This work deals with the applicability of fracture mechanics and damage tolerance concepts to the components of prestressed systems, which are used in civil engineering. Such concepts have been applied to assess the susceptibility of the prestressing steel wires to stress corrosion cracking and the reduction of load bearing capability of anchorage devices due to the presence of defects. For this purpose a combination of experimental work and numerical techniques have been performed. Surface defects in prestressing steel wires are not shown alone, though a certain degree of continuity in the axial direction exist. A significant number of such defects is also observed. Hence a statistical approach was used, which is assumed to be more appropriate than the deterministic approach. The use of statistical methods based in extreme value theories has allowed the characterising of the surface condition of 5.2 mm-diameter wires. On the other hand the stress corrosion cracking susceptibility of the wire has been assessed by means of an experimental testing program in line with the current regulations, which has allowed statistical characterisasion of their performances against stress corrosion cracking. In the light of the test results, it has been possible to evaluate how the surface condition parameters could determine the durability of the active metal armour regarding to its resistance against stress corrosion cracking assessed by means of the current testing regulations. In the case of anchorage devices for steel tendons for prestressing concrete, the damage is presented as point defects originating from dents, scratches or corrosion pits that could be produced during the manufacturing proccess, transport, handling, assembly or use. Due to the nature of these defects, in this case the deterministic approach is more appropriate than the statistical approach. The assessment of the relevancy of defect in a structural component requires the computation of the stress intensity factors, which in turn allow the evaluation of whether the size defect is critical or could become critical with the progress of time (due to fatigue, corrosion or a combination of both effects). In this work the damage is idealised as tiny cracks, a conservative hypothesis. The stress intensity factors have been calculated by means of finite element models of the anchorage representing the real working conditions during its service life. These numeric models were used to assess the impact of some factors on the rupture load of the anchorage, such the anchorage geometry, material, support conditions, defect size, shape and its location. The results from the numerical analysis have been succesfully correlated against the results of the experimental testing program of scaled models of the anchorages in poly-methil methacrylate in which artificial damage in several sizes and locations were introduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Con esta tesis ”Desarrollo de una Teoría Uniforme de la Difracción para el Análisis de los Campos Electromagnéticos Dispersados y Superficiales sobre un Cilindro” hemos iniciado una nueva línea de investigación que trata de responder a la siguiente pregunta: ¿cuál es la impedancia de superficie que describe una estructura de conductor eléctrico perfecto (PEC) convexa recubierta por un material no conductor? Este tipo de estudios tienen interés hoy en día porque ayudan a predecir el campo electromagnético incidente, radiado o que se propaga sobre estructuras metálicas y localmente convexas que se encuentran recubiertas de algún material dieléctrico, o sobre estructuras metálicas con pérdidas, como por ejemplo se necesita en determinadas aplicaciones aeroespaciales, marítimas o automovilísticas. Además, desde un punto de vista teórico, la caracterización de la impedancia de superficie de una estructura PEC recubierta o no por un dieléctrico es una generalización de varias soluciones que tratan ambos tipos de problemas por separado. En esta tesis se desarrolla una teoría uniforme de la difracción (UTD) para analizar el problema canónico del campo electromagnético dispersado y superficial en un cilindro circular eléctricamente grande con una condición de contorno de impedancia (IBC) para frecuencias altas. Construir una solución basada en UTD para este problema canónico es crucial en el desarrollo de un método UTD para el caso más general de una superficie arbitrariamente convexa, mediante el uso del principio de localización de los campos electromagnéticos a altas frecuencias. Esta tesis doctoral se ha llevado a cabo a través de una serie de hitos que se enumeran a continuación, enfatizando las contribuciones a las que ha dado lugar. Inicialmente se realiza una revisión en profundidad del estado del arte de los métodos asintóticos con numerosas referencias. As í, cualquier lector novel puede llegar a conocer la historia de la óptica geométrica (GO) y la teoría geométrica de la difracción (GTD), que dieron lugar al desarrollo de la UTD. Después, se investiga ampliamente la UTD y los trabajos más importantes que pueden encontrarse en la literatura. As í, este capítulo, nos coloca en la posición de afirmar que, hasta donde nosotros conocemos, nadie ha intentado antes llevar a cabo una investigación rigurosa sobre la caracterización de la impedancia de superficie de una estructura PEC recubierta por un material dieléctrico, utilizando para ello la UTD. Primero, se desarrolla una UTD para el problema canónico de la dispersión electromagnética de un cilindro circular eléctricamente grande con una IBC uniforme, cuando es iluminado por una onda plana con incidencia oblicua a frecuencias altas. La solución a este problema canónico se construye a partir de una solución exacta mediante una expansión de autofunciones de propagación radial. Entonces, ésta se convierte en una nueva expansión de autofunciones de propagación circunferencial muy apropiada para cilindros grandes, a través de la transformación de Watson. De esta forma, la expresión del campo se reduce a una integral que se evalúa asintóticamente, para altas frecuencias, de manera uniforme. El resultado se expresa según el trazado de rayos descrito en la UTD. La solución es uniforme porque tiene la importante propiedad de mantenerse continua a lo largo de la región de transición, a ambos lados de la superficie del contorno de sombra. Fuera de la región de transición la solución se reduce al campo incidente y reflejado puramente ópticos en la región iluminada del cilindro, y al campo superficial difractado en la región de sombra. Debido a la IBC el campo dispersado contiene una componente contrapolar a causa de un acoplamiento entre las ondas TEz y TMz (donde z es el eje del cilindro). Esta componente contrapolar desaparece cuando la incidencia es normal al cilindro, y también en la región iluminada cuando la incidencia es oblicua donde el campo se reduce a la solución de GO. La solución UTD presenta una muy buena exactitud cuando se compara numéricamente con una solución de referencia exacta. A continuación, se desarrolla una IBC efectiva para el cálculo del campo electromagnético dispersado en un cilindro circular PEC recubierto por un dieléctrico e iluminado por una onda plana incidiendo oblicuamente. Para ello se derivan dos impedancias de superficie en relación directa con las ondas creeping y de superficie TM y TE que se excitan en un cilindro recubierto por un material no conductor. Las impedancias de superficie TM y TE están acopladas cuando la incidencia es oblicua, y dependen de la geometría del problema y de los números de onda. Además, se ha derivado una impedancia de superficie constante, aunque con diferente valor cuando el observador se encuentra en la zona iluminada o en la zona de sombra. Después, se presenta una solución UTD para el cálculo de la dispersión de una onda plana con incidencia oblicua sobre un cilindro eléctricamente grande y convexo, mediante la generalización del problema canónico correspondiente al cilindro circular. La solución asintótica es uniforme porque se mantiene continua a lo largo de la región de transición, en las inmediaciones del contorno de sombra, y se reduce a la solución de rayos ópticos en la zona iluminada y a la contribución de las ondas de superficie dentro de la zona de sombra, lejos de la región de transición. Cuando se usa cualquier material no conductor se excita una componente contrapolar que tiende a desaparecer cuando la incidencia es normal al cilindro y en la región iluminada. Se discuten ampliamente las limitaciones de las fórmulas para la impedancia de superficie efectiva, y se compara la solución UTD con otras soluciones de referencia, donde se observa una muy buena concordancia. Y en tercer lugar, se presenta una aproximación para una impedancia de superficie efectiva para el cálculo de los campos superficiales en un cilindro circular conductor recubierto por un dieléctrico. Se discuten las principales diferencias que existen entre un cilindro PEC recubierto por un dieléctrico desde un punto de vista riguroso y un cilindro con una IBC. Mientras para un cilindro de impedancia se considera una impedancia de superficie constante o uniforme, para un cilindro conductor recubierto por un dieléctrico se derivan dos impedancias de superficie. Estas impedancias de superficie están asociadas a los modos de ondas creeping TM y TE excitadas en un cilindro, y dependen de la posición y de la orientación del observador y de la fuente. Con esto en mente, se deriva una solución UTD con IBC para los campos superficiales teniendo en cuenta las dependencias de la impedancia de superficie. La expansión asintótica se realiza, mediante la transformación de Watson, sobre la representación en serie de las funciones de Green correspondientes, evitando as í calcular las derivadas de orden superior de las integrales de tipo Fock, y dando lugar a una solución rápida y precisa. En los ejemplos numéricos realizados se observa una muy buena precisión cuando el cilindro y la separación entre el observador y la fuente son grandes. Esta solución, junto con el método de los momentos (MoM), se puede aplicar para el cálculo eficiente del acoplamiento mutuo de grandes arrays conformados de antenas de parches. Los métodos propuestos basados en UTD para el cálculo del campo electromagnético dispersado y superficial sobre un cilindro PEC recubierto de dieléctrico con una IBC efectiva suponen un primer paso hacia la generalización de una solución UTD para superficies metálicas convexas arbitrarias cubiertas por un material no conductor e iluminadas por una fuente electromagnética arbitraria. ABSTRACT With this thesis ”Development of a Uniform Theory of Diffraction for Scattered and Surface Electromagnetic Field Analysis on a Cylinder” we have initiated a line of investigation whose goal is to answer the following question: what is the surface impedance which describes a perfect electric conductor (PEC) convex structure covered by a material coating? These studies are of current and future interest for predicting the electromagnetic (EM) fields incident, radiating or propagating on locally smooth convex parts of highly metallic structures with a material coating, or by a lossy metallic surfaces, as for example in aerospace, maritime and automotive applications. Moreover, from a theoretical point of view, the surface impedance characterization of PEC surfaces with or without a material coating represents a generalization of independent solutions for both type of problems. A uniform geometrical theory of diffraction (UTD) is developed in this thesis for analyzing the canonical problem of EM scattered and surface field by an electrically large circular cylinder with an impedance boundary condition (IBC) in the high frequency regime, by means of a surface impedance characterization. The construction of a UTD solution for this canonical problem is crucial for the development of the corresponding UTD solution for the more general case of an arbitrary smooth convex surface, via the principle of the localization of high frequency EM fields. The development of the present doctoral thesis has been carried out through a series of landmarks that are enumerated as follows, emphasizing the main contributions that this work has given rise to. Initially, a profound revision is made in the state of art of asymptotic methods where numerous references are given. Thus, any reader may know the history of geometrical optics (GO) and geometrical theory of diffraction (GTD), which led to the development of UTD. Then, the UTD is deeply investigated and the main studies which are found in the literature are shown. This chapter situates us in the position to state that, as far as we know, nobody has attempted before to perform a rigorous research about the surface impedance characterization for material-coated PEC convex structures via UTD. First, a UTD solution is developed for the canonical problem of the EM scattering by an electrically large circular cylinder with a uniform IBC, when it is illuminated by an obliquely incident high frequency plane wave. A solution to this canonical problem is first constructed in terms of an exact formulation involving a radially propagating eigenfunction expansion. The latter is converted into a circumferentially propagating eigenfunction expansion suited for large cylinders, via the Watson transformation, which is expressed as an integral that is subsequently evaluated asymptotically, for high frequencies, in a uniform manner. The resulting solution is then expressed in the desired UTD ray form. This solution is uniform in the sense that it has the important property that it remains continuous across the transition region on either side of the surface shadow boundary. Outside the shadow boundary transition region it recovers the purely ray optical incident and reflected ray fields on the deep lit side of the shadow boundary and to the modal surface diffracted ray fields on the deep shadow side. The scattered field is seen to have a cross-polarized component due to the coupling between the TEz and TMz waves (where z is the cylinder axis) resulting from the IBC. Such cross-polarization vanishes for normal incidence on the cylinder, and also in the deep lit region for oblique incidence where it properly reduces to the GO or ray optical solution. This UTD solution is shown to be very accurate by a numerical comparison with an exact reference solution. Then, an effective IBC is developed for the EM scattered field on a coated PEC circular cylinder illuminated by an obliquely incident plane wave. Two surface impedances are derived in a direct relation with the TM and TE surface and creeping wave modes excited on a coated cylinder. The TM and TE surface impedances are coupled at oblique incidence, and depend on the geometry of the problem and the wave numbers. Nevertheless, a constant surface impedance is found, although with a different value when the observation point lays in the lit or in the shadow region. Then, a UTD solution for the scattering of an obliquely incident plane wave on an electrically large smooth convex coated PEC cylinder is introduced, via a generalization of the canonical circular cylinder problem. The asymptotic solution is uniform because it remains continuous across the transition region, in the vicinity of the shadow boundary, and it recovers the ray optical solution in the deep lit region and the creeping wave formulation within the deep shadow region. When a coating is present a cross-polar field term is excited, which vanishes at normal incidence and in the deep lit region. The limitations of the effective surface impedance formulas are discussed, and the UTD solution is compared with some reference solutions where a very good agreement is met. And in third place, an effective surface impedance approach is introduced for determining surface fields on an electrically large coated metallic circular cylinder. Differences in analysis of rigorouslytreated coated metallic cylinders and cylinders with an IBC are discussed. While for the impedance cylinder case a single constant or uniform surface impedance is considered, for the coated metallic cylinder case two surface impedances are derived. These are associated with the TM and TE creeping wave modes excited on a cylinder and depend on observation and source positions and orientations. With this in mind, a UTD based method with IBC is derived for the surface fields by taking into account the surface impedance variation. The asymptotic expansion is performed, via the Watson transformation, over the appropriate series representation of the Green’s functions, thus avoiding higher-order derivatives of Fock-type integrals, and yielding a fast and an accurate solution. Numerical examples reveal a very good accuracy for large cylinders when the separation between the observation and the source point is large. Thus, this solution could be efficiently applied in mutual coupling analysis, along with the method of moments (MoM), of large conformal microstrip array antennas. The proposed UTD methods for scattered and surface EM field analysis on a coated PEC cylinder with an effective IBC are considered the first steps toward the generalization of a UTD solution for large arbitrarily convex smooth metallic surfaces covered by a material coating and illuminated by an arbitrary EM source.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A través de los años las estructuras de hormigón armado han ido aumentando su cuota de mercado, sustituyendo a las estructuras de fábrica de piedra o ladrillo y restándole participación a las estructuras metálicas. Uno de los primeros problemas que surgieron al ejecutar las estructuras de hormigón armado, era cómo conectar una fase de una estructura de este tipo a una fase posterior o a una modificación posterior. Hasta los años 80-90 las conexiones de una fase de una estructura de hormigón armado, con otra posterior se hacían dejando en la primera fase placas de acero con garrotas embebidas en el hormigón fresco o barras grifadas recubiertas de poliestireno expandido. Una vez endurecido el hormigón se podían conectar nuevas barras, para la siguiente fase mediante soldadura a la placa de la superficie o enderezando las barras grifadas, para embeberlas en el hormigón fresco de la fase siguiente. Estos sistemas requerían conocer la existencia y alcance de la fase posterior antes de hormigonar la fase previa. Además requerían un replanteo muy exacto y complejo de los elementos de conexión. Otro problema existente en las estructuras de hormigón era la adherencia de un hormigón fresco a un hormigón endurecido previamente, ya que la superficie de contacto de ambos hormigones suponía un punto débil, con una adherencia baja. A partir de los años 80, la industria química de la construcción experimentó un gran avance en el desarrollo de productos capaces de generar una buena adherencia sobre el hormigón endurecido. Este avance tecnológico tenía aplicación tanto en la adherencia del hormigón fresco sobre el hormigón endurecido, como en la adherencia de barras post-instaladas en agujeros de hormigón endurecido. Este sistema se denominó “anclajes adherentes de barras de acero en hormigón endurecido”. La forma genérica de ejecutarlos es hacer una perforación cilíndrica en el soporte de hormigón, con una herramienta especifica como un taladro, limpiar la perforación, llenarla del material adherente y finalmente introducir la barra de acero. Los anclajes adherentes se dividen en anclajes cementosos y anclajes químicos, siendo estos últimos los más habituales, fiables, resistentes y fáciles de ejecutar. El uso del anclaje adherente de barras de acero en hormigón endurecido se ha extendido por todo el espectro productivo, siendo muy habitual tanto en construcción de obras de hormigón armado de obra civil y edificación, como en obras industriales, instalaciones o fijación de elementos. La ejecución de un anclaje de una barra de acero en hormigón endurecido depende de numerosas variables, que en su conjunto, o de forma aislada pueden afectar de forma notable a la resistencia del anclaje. Nos referimos a variables de los anclajes, que a menudo no se consideran tales como la dirección de la perforación, la máquina de perforación y el útil de perforación utilizado, la diferencia de diámetros entre el diámetro del taladro y la barra, el tipo de material de anclaje, la limpieza del taladro, la humedad del soporte, la altura del taladro, etc. La utilización en los últimos años de los hormigones Autocompactables, añade una variable adicional, que hasta ahora apenas ha sido estudiada. En línea con lo apuntado, la presente tesis doctoral tiene como objetivo principal el estudio de las condiciones de ejecución en la resistencia de los anclajes en hormigón convencional y autocompactable. Esta investigación se centra principalmente en la evaluación de la influencia de una serie de variables sobre la resistencia de los anclajes, tanto en hormigón convencional como en un hormigón autocompactable. Para este estudio ha sido necesaria la fabricación de dos soportes de hormigón sobre los cuales desarrollar los ensayos. Uno de los bloques se ha fabricado con hormigón convencional y el otro con hormigón autocompactable. En cada pieza de hormigón se han realizado 174 anclajes con barras de acero, variando los parámetros a estudiar, para obtener resultados de todas las variables consideradas. Los ensayos a realizar en ambos bloques son exactamente iguales, para poder comparar la diferencia entre un anclaje en un soporte de hormigón con vibrado convencional (HVC) y un hormigón autocompactante (HAC). De cada tipo de ensayo deseado se harán dos repeticiones en la misma pieza. El ensayo de arrancamiento de las barras se realizara con un gato hidráulico hueco, con un sistema de instrumentación de lectura y registro de datos en tiempo real. El análisis de los resultados, realizado con una potente herramienta estadística, ha permitido determinar y evaluar numéricamente la influencia de los variables consideradas en la resistencia de los anclajes realizados. Así mismo ha permitido diferenciar los resultados obtenidos en los hormigones convencionales y autocompactantes, tanto desde el punto de vista de la resistencia mecánica, como de las deformaciones sufridas en el arrancamiento. Se define la resistencia mecánica de un anclaje, como la fuerza desarrollada en la dirección de la barra, para hacer su arrancamiento del soporte. De la misma forma se considera desplazamiento, a la separación entre un punto fijo de la barra y otro del soporte, en la dirección de la barra. Dichos puntos se determinan cuando se ha terminado el anclaje, en la intersección de la superficie plana del soporte, con la barra. Las conclusiones obtenidas han permitido establecer qué variables afectan a la ejecución de los anclajes y en qué cuantía lo hacen, así como determinar la diferencia entre los anclajes en hormigón vibrado convencional y hormigón autocompactante, con resultados muy interesantes, que permiten valorar la influencia de dichas variables. Dentro de las conclusiones podemos destacar tres grupos, que denominaremos como de alta influencia, baja influencia y sin influencia. En todos los casos hay que hacer el estudio en términos de carga y de desplazamiento. Podemos considerar como de alta influencia, en términos de carga las variables de máquina de perforación y el material de anclaje. En términos de desplazamiento podemos considerar de alta influencia además de la máquina de perforación y el material de anclaje, el diámetro del taladro, así como la limpieza y humedad del soporte. Podemos considerar de baja influencia, en términos de carga las variables de tipo de hormigón, dirección de perforación, limpieza y humedad del soporte. En términos de desplazamiento podemos considerar de baja influencia el tipo de hormigón y la dirección de perforación. Podemos considerar en el apartado de “sin influencia”, en términos de carga las variables de diámetro de perforación y altura del taladro. En términos de desplazamiento podemos considerar como “sin influencia” la variable de altura del taladro. Podemos afirmar que las diferencias entre los valores de carga aumentan de forma muy importante en términos de desplazamiento. ABSTRACT Over the years the concrete structures have been increasing their market share, replacing the masonry structures of stone or brick and subtracting as well the participation of the metallic structures. One of the first problems encountered in the implementing of the reinforced concrete structures was connecting a phase structure of this type at a later stage or a subsequent amendment. Until the 80s and 90s the connections of one phase of a reinforced concrete structure with a subsequent first phase were done by leaving the steel plates embedded in the fresh concrete using hooks or bent bars coated with expanded polystyrene. Once the concrete had hardened new bars could be connected to the next stage by welding them to the surface plate or by straightening the bent bars to embed them in the fresh concrete of the next phase. These systems required a previous knowledge of the existence and scope of the subsequent phase before concreting the previous one. They also required a very precise and complex rethinking of the connecting elements. Another existing problem in the concrete structures was the adhesion of a fresh concrete to a previously hardened concrete, since the contact surface of both concretes leaded to a weak point with low adherence. Since the 80s, the chemicals construction industry experienced a breakthrough in the development of products that generate a good grip on the concrete. This technological advance had its application both in the grip on one hardened fresh concrete and in the adhesion of bar post-installed in holes of hardened concrete. This system was termed as adherent anchors of steel bars in hardened concrete. The generic way of executing this system is by firstly drilling a cylindrical hole in the concrete support using a specific tool such as a drill. Then, cleaning the bore and filling it with bonding material to lastly, introduce the steel bar. These adherent anchors are divided into cement and chemical anchors, the latter being the most common, reliable, durable and easy to run. The use of adhesive anchor of steel bars in hardened concrete has spread across the production spectrum turning itself into a very common solution in both construction of reinforced concrete civil engineering and construction, and industrial works, installations and fixing elements as well. The execution of an anchor of a steel bar in hardened concrete depends on numerous variables which together or as a single solution may significantly affect the strength of the anchor. We are referring to variables of anchors which are often not considered, such as the diameter difference between the rod and the bore, the drilling system, cleansing of the drill, type of anchor material, the moisture of the substrate, the direction of the drill, the drill’s height, etc. During recent years, the emergence of self-compacting concrete adds an additional variable which has hardly been studied so far. According to mentioned this thesis aims to study the main performance conditions in the resistance of conventional and self-compacting concrete anchors. This research is primarily focused on the evaluation of the influence of several variables on the strength of the anchoring, both in conventional concrete and self-compacting concrete. In order to complete this study it has been required the manufacture of two concrete supports on which to develop the tests. One of the blocks has been manufactured with conventional concrete and the other with self-compacting concrete. A total of 174 steel bar anchors have been made in each one of the concrete pieces varying the studied parameters in order to obtain results for all variables considered. The tests to be performed on both blocks are exactly the same in order to compare the difference between an anchor on a stand with vibrated concrete (HVC) and a self-compacting concrete (SCC). Each type of test required two repetitions in the same piece. The pulling test of the bars was made with a hollow jack and with an instrumentation system for reading and recording data in real time. The use of a powerful statistical tool in the analysis of the results allowed to numerically determine and evaluate the influence of the variables considered in the resistance of the anchors made. It has likewise enabled to differentiate the results obtained in the self-compacting and conventional concretes, from both the outlook of the mechanical strength and the deformations undergone by uprooting. The mechanical strength of an anchor is defined as the strength undergone in a direction of the bar to uproot it from the support. Likewise, the movement is defined as the separation between a fixed point of the bar and a fixed point from the support considering the direction of the bar. These points are only determined once the anchor is finished, with the bar, at the intersection in the flat surface of the support. The conclusions obtained have established which variables affect the execution of the anchors and in what quantity. They have also permitted to determine the difference between the anchors in vibrated concrete and selfcompacting concrete with very interesting results that also allow to assess the influence of these mentioned variables. Three groups are highlighted among the conclusions called high influence, low influence and no influence. In every case is necessary to perform the study in terms of loading and movement. In terms of loading, there are considered as high influence two variables: drilling machinery and anchorage material. In terms of movement, there are considered as high influence the drilling diameter and the cleaning and moisture of the support, besides the drilling machinery and the anchorage material. Variables such as type of concrete, drilling direction and cleaning and moisture of the support are considered of low influence in terms of load. In terms of movement, the type of concrete and the direction of the drilling are considered variables of low influence. Within the no influence section in terms of loading, there are included the diameter of the drilling and the height of the drill. In terms of loading, the height of the drill is considered as a no influence variable. We can affirm that the differences among the loading values increase significantly in terms of movement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This doctoral thesis explores some of the possibilities that near-field optics can bring to photovoltaics, and in particular to quantum-dot intermediate band solar cells (QD-IBSCs). Our main focus is the analytical optimization of the electric field distribution produced in the vicinity of single scattering particles, in order to produce the highest possible absorption enhancement in the photovoltaic medium in their surroundings. Near-field scattering structures have also been fabricated in laboratory, allowing the application of the previously studied theoretical concepts to real devices. We start by looking into the electrostatic scattering regime, which is only applicable to sub-wavelength sized particles. In this regime it was found that metallic nano-spheroids can produce absorption enhancements of about two orders of magnitude on the material in their vicinity, due to their strong plasmonic resonance. The frequency of such resonance can be tuned with the shape of the particles, allowing us to match it with the optimal transition energies of the intermediate band material. Since these metallic nanoparticles (MNPs) are to be inserted inside the cell photovoltaic medium, they should be coated by a thin insulating layer to prevent electron-hole recombination at their surface. This analysis is then generalized, using an analytical separation-of-variables method implemented in Mathematica7.0, to compute scattering by spheroids of any size and material. This code allowed the study of the scattering properties of wavelengthsized particles (mesoscopic regime), and it was verified that in this regime dielectric spheroids perform better than metallic. The light intensity scattered from such dielectric spheroids can have more than two orders of magnitude than the incident intensity, and the focal region in front of the particle can be shaped in several ways by changing the particle geometry and/or material. Experimental work was also performed in this PhD to implement in practice the concepts studied in the analysis of sub-wavelength MNPs. A wet-coating method was developed to self-assemble regular arrays of colloidal MNPs on the surface of several materials, such as silicon wafers, amorphous silicon films, gallium arsenide and glass. A series of thermal and chemical tests have been performed showing what treatments the nanoparticles can withstand for their embedment in a photovoltaic medium. MNPs arrays are then inserted in an amorphous silicon medium to study the effect of their plasmonic near-field enhancement on the absorption spectrum of the material. The self-assembled arrays of MNPs constructed in these experiments inspired a new strategy for fabricating IBSCs using colloidal quantum dots (CQDs). Such CQDs can be deposited in self-assembled monolayers, using procedures similar to those developed for the patterning of colloidal MNPs. The use of CQDs to form the intermediate band presents several important practical and physical advantages relative to the conventional dots epitaxially grown by the Stranski-Krastanov method. Besides, this provides a fast and inexpensive method for patterning binary arrays of QDs and MNPs, envisioned in the theoretical part of this thesis, in which the MNPs act as antennas focusing the light in the QDs and therefore boosting their absorption

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La aparición de la fatiga ha sido ampliamente investigada en el acero y en otros materiales metálicos, sin embargo no se conoce en tanta profundidad en el hormigón estructural. Esto crea falta de uniformidad y enfoque en el proceso de verificación de estructuras de hormigón para el estado límite último de la fatiga. A medida que se llevan a cabo más investigaciones, la información sobre los parámetros que afectan a la fatiga en el hormigón comienzan a ser difundidos e incluso los que les afectan de forma indirecta. Esto conlleva a que se estén incorporando en las guías de diseño de todo el mundo, a pesar de que la comprobación del estado límite último no se trata por igual entre los distintos órganos de diseño. Este trabajo presentará un conocimiento básico del fenómeno de la fatiga, qué lo causa y qué condiciones de carga o propiedades materiales amplían o reducen la probabilidad de fallo por fatiga. Cuatro distintos códigos de diseño serán expuestos y su proceso de verificación ha sido examinado, comparados y valorados cualitativa y cuantitativamente. Una torre eólica, como ejemplo, fue analizada usando los procedimientos de verificación como se indica en sus respectivos códigos de referencia. The occurrence of fatigue has been extensively researched in steel and other metallic materials it is however, not as broadly understood in concrete. This produces a lack of uniformity in the approach and process in the verification of concrete structures for the ultimate limit state of fatigue. As more research is conducted and more information is known about the parameters which cause, propagate, and indirectly affect fatigue in concrete, they are incorporated in design guides around the world. Nevertheless, this ultimate limit state verification is not addressed equally by various design governing bodies. This report presents a baseline understanding of what the phenomenon of fatigue is, what causes it, and what loading or material conditions amplify or reduce the likelihood of fatigue failure. Four different design codes are exposed and their verification process has been examined, compared and evaluated both qualitatively and quantitatively. Using a wind turbine tower structure as case study, this report presents calculated results following the verification processes as instructed in the respective reference codes.