30 resultados para Mechanical Test Equipment.

em Universidad Politécnica de Madrid


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Some laboratory tests consisting on quasi-static compression and puncture forces carried out on twelve varieties of apricot during 1990 and 1991 were effective in sorting them. These mechanical properties show a high correlation w i th the ethylene production rate per fruit, so allowing to discriminate between ripeness levels at harvest. In this study it is also demonstrated that puncture seems to be the less variable mechanical test. The values (N/mm) obtained with it show a highly significant correlation with compression resistance and with quasi-static compression damage of the fruits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La mejora en la eficiencia energética y la reducción de la tasa de fallos en los contactos lubricados son aspectos que resultan de gran interés en numerosos sectores de la industria, y plantean en estos momentos nuevas dificultades operativas y retos para un futuro próximo. Los avances tecnológicos han incrementado las exigencias técnicas que se requieren a los aceites para cumplir su función al extender sus variables operativas a un mayor espectro de aplicaciones, tanto de condiciones de funcionamiento como a la gran variedad de nuevos materiales constitutivos de los engranajes en los que se tiene que utilizar. Por ello, actualmente se está incentivado el desarrollo de nuevos procedimientos que permitan comprender el comportamiento de este tipo de contactos lubricados, con el fin de lograr mejoras técnicas en su diseño y la correcta selección del aceite. En esta Tesis Doctoral se presenta una metodología de cálculo numérico que permite simular el comportamiento de contactos elastohidrodinámicos (EHD) puntuales, como puede ser el caso de un rodamiento. La resolución de este problema presenta diversas complejidades matemáticas y exige el desarrollo de un elaborado procedimiento de cálculo basado en técnicas multinivel. Para hacer del procedimiento una herramienta válida en un gran número de condiciones de funcionamiento y tipos de lubricantes, se ha tenido en cuenta en el cálculo la posible aparición de comportamientos no-Newtonianos del lubricante y fenómenos de generación y disipación de calor, provocados por el movimiento relativo del fluido y las superficies en contacto. Para la validación del procedimiento, se han contrastado los resultados numéricos obtenidos con nuestro método, con los resultados numéricos y experimentales publicados por otros autores y con valores experimentales propios medidos en un equipo de ensayo de contacto puntual tipo MTM. El desarrollo de este programa ha dotado a la División de Ingeniería de Máquinas de una herramienta que ha permitido, y sobre todo va permitir, evaluar la importancia de cada uno de los parámetros reológicos en los diferentes problemas que va a tener que abordar, evaluación que hasta el momento se realizaba con métodos aproximados que describen la fenomenología con mucha menos precisión. A la hora de emplear nuestro procedimiento numérico para simular situaciones reales, nos hemos encontrado con el obstáculo de que es muy complicado encontrar, en la bibliografía y bases de datos, los parámetros que caracterizan el comportamiento reológico del lubricante en las condiciones de presión, temperatura y grado de cizallamiento habituales en las que se trabaja en este tipo de contactos, y las pocas medidas que existen para estas condiciones de funcionamiento son poco fiables. Por ello como complemento al objetivo principal de esta Tesis hemos desarrollado una metodología para caracterizar los lubricantes en estas condiciones extremas. Dicha metodología está basada en la buena descripción que hace nuestro programa del coeficiente de fricción, lo que nos ha permitido obtener los parámetros reológicos del III lubricante a partir de las medidas experimentales del coeficiente de fricción generado en un equipo MTM lubricado con el lubricante que se desea caracterizar. Madrid, Octubre de 2012 IV Improving energy efficiency and reducing the failure rate in lubricated contacts are issues that are of great interest in many sectors of industry, and right now posed operational difficulties and new challenges for the near future. Technological advances have increased the technical demands required to oils to fulfil its role by extending its operational variables to a wider range of applications, both operating conditions and to the wide variety of new materials which constitute the gear in which must be used. For this reason, has being encouraged currently to develop new procedures to understand the behaviour of this type of lubricated contacts, in order to achieve improvements in design techniques and the correct oil selection. In this Thesis we present a numerical methodology to simulate the puntual elastohydrodynamic contact behaviour (EHD), such as a roller bearing. The resolution of this problem presents various mathematical complexities and requires the development of an elaborate calculation procedure based on multilevel techniques. To make the procedure a valid tool in a wide range of operating conditions and types of lubricants, has been taken into account in calculating the possible occurrence of non-Newtonian behaviour of the lubricant and phenomena of generation and dissipation of heat, caused by the fluid relative motion and contacting surfaces. For the validation of the method, we have compared the numerical results obtained with our method with numerical and experimental results published by other authors also with own experimental values measured on point-contact test equipment MTM. The development of this program has provided the Machines Engineering Division of a tool that has allowed, and especially will allow to evaluate the importance of each of the rheological parameters on the various problems that will have to be addressed, evaluation performed hitherto described methods that phenomenology approximated with much less accuracy. When using our numerical procedure to simulate real situations we have encountered the obstacle that is very difficult to find, in the literature and database, parameters characterizing the rheological behaviour of the lubricant in the usual conditions of pressure, temperature and shear rate in which you work in this type of contact, and the few measures that exist for these operating conditions are unreliable. Thus in addition to the main objective of this thesis, we have developed a methodology to characterize the lubricants in these extreme conditions. This methodology is based on the good description, which makes our program, of the coefficient of friction, that allowed us to obtain the lubricant rheological parameters from experimental measurements of the friction coefficient generated on lubricated MTM equipment with the lubricant to be characterized.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mealiness, a textural disorder that produces quality loss, combines softness and absence of juiciness. The only one (destructive) test to measure it, combines information from a mechanical test on fruit probes to classify the samples according to instrumental mealiness. Time-domain laser reflectance spectroscopy (TDRS) is able to assess simultaneously and independently the absorption of the light inside the irradiated body (µa coefficient) and the scattering of the photons across the tissues (µS, transport scattering coeff.) measured at each wavelength. Using VIS&NIR lasers as light sources, TDRS was applied to Golden Delicious and Cox apples (n=90), conforming batches of untreated samples and storage-treated (20°C&95%RH) to induce mealiness development. The collected database was clustered into different groups according to their instrumental mealiness. Optical variables were used to build discriminant functions, achieving classification scores 75-89% of correctly identified mealy apples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The latest technology and architectural trends have significantly improved the use of a large variety of glass products in construction which, in function of their own characteristocs, allow to design and calculate structural glass elements under safety conditions. This paper presents the evaluation and analysis of the damping properties of rectangular laminated glass plates of 1.938 m x 0.876 m with different thickness depending on the number of PVB interlayers arranged. By means of numerical simulation and experimental verification, using modal analysis, natural frequencies and damping of the glass plates were calculated, both under free boundary conditions and operational conditions for the impact test equipment used in the experimental program, as the European standard UNE-EN 12600:2003 specifies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El objetivo de este trabajo es conocer las posibles modificaciones que puede producir en el comportamiento de las estructuras de hormigón armado (EHA) el hecho de que sean utilizadas como estructuras termoactivas, ya sea como intercambiadores en contacto con el terreno, o como sistema de distribución de calor utilizando la inercia térmica de los elementos de hormigón del edificio, basándose en el uso de energías renovables. Las EHA termoactivas se caracterizan por la incorporación en su interior de tubos de polietileno por los que circulan fluidos a temperaturas medias, que pueden incidir en el comportamiento mecánico de los elementos estructurales debido a dos efectos fundamentales: el incremento de temperatura que se produce en el interior de la EHA y la perturbación provocada por la incorporación de los tubos de polietileno. Con este fin, se ha realizado una campaña experimental de probetas de hormigón, estudiando los dos efectos por separado, por un lado se ha evaluado el comportamiento de probetas de hormigón tipo H-25 y tipo H-30 sometidas a cuatro temperaturas diferentes: 20ºC, 40ºC, 70ºC y 100ºC, ensayando la resistencia a compresión y la resistencia a anclaje/adherencia mediante ensayo “pull-out”; y, por otro lado, se ha evaluado el comportamiento de probetas de hormigón tipo H-25 y tipo H-30, elaboradas con dos tipos de molde (cilíndrico y cúbico), en las que se ha colocado tubos de polietileno en su interior en distintas posiciones, ensayando su resistencia a compresión. Los resultados de los ensayos han puesto de manifiesto que aunque se produce una disminución en la resistencia a compresión, y a arrancamiento, del hormigón, al ser sometido a aumentos de temperatura, esta disminución de la propiedades mecánicas es inferior al 20% al no superar esta tecnología los 70ºC; y respecto a la variación de la resistencia a compresión de probetas cilíndricas y cúbicas, debidas a la incorporación de los tubos de polietileno, se observa que si la posición de los mismos es paralela a la dirección de la carga tampoco se ven comprometidas las propiedad mecánicas del hormigón en valores superiores al 20%. ABSTRACT The aim of this project is to study the effects of using concrete structures as thermo-active constructions, either as energy foundations or other kind of thermo-active ground structures, or as a thermally activated building structure utilizing its own thermal mass conductivity and storage capacity to heat and cool buildings, based on renewable or “free” energy sources. The pipes, filled with a heat carrier fluid, that are embedded into the building´s concrete elements may bring on two different adverse effects on concrete structures. In one hand, the consequence of thermal variations and, on the other hand, because of the fact that the pipes are inside of the concrete mortar and in direct contact with the reinforcing steel bars. For this reason, different types of specimens and testing procedures have been proposed to discuss the effects of temperature (20º, 40ºC, 70ºC y 100ºC) on the performance of two different hardened concrete: H-25 and H-30, and the effects of having the pipes embedded in different positions inside of specimens made of two types of concrete, H-25 and H-30, and with two kind of cast, cylindrical and cubical. The experimental program includes the use of compressive strength test and also pull-out test, in order to investigate the interfacial adhesion quality and interfacial properties between steel bar and concrete. The results of the mechanical test showed that the increase of temperature in hardened concrete specimens lower than 70ºC, and the introduction of embedded pipes placed in parallel to the load, in cylindrical or cubic specimens, does not jeopardize the mechanical properties of concrete with strength decreases higher than 20%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En la actualidad gran parte de las industrias utilizan o desarrollan plataformas, las cuales integran un número cada vez más elevado de sistemas complejos. El mantenimiento centralizado permite optimizar el mantenimiento de estas plataformas, por medio de la integración de un sistema encargado de gestionar el mantenimiento de todos los sistemas de la plataforma. Este Trabajo Fin de Máster (TFM) desarrolla el concepto de mantenimiento centralizado para sistemas complejos, aplicable a plataformas formadas por sistemas modulares. Está basado en la creciente demanda de las diferentes industrias en las que se utilizan este tipo de plataformas, como por ejemplo la industria aeronáutica, del ferrocarril y del automóvil. Para ello este TFM analiza el Estado del Arte de los sistemas de mantenimiento centralizados en diferentes industrias, además desarrolla los diferentes tipos de arquitecturas de sistemas, las técnicas de mantenimiento aplicables, así como los sistemas y técnicas de mantenimiento basados en funciones de monitorización y auto diagnóstico denominadas Built-In-Test Equipment (BITE). Adicionalmente, este TFM incluye el desarrollo e implementación de un modelo de un Entorno de Mantenimiento Centralizado en LabVIEW. Este entorno está formado por el modelo de un Sistema Patrón, así como el modelo del Sistema de Mantenimiento Centralizado y la interfaces entre ellos. El modelo del Sistema de Mantenimiento Centralizado integra diferentes funciones para el diagnóstico y aislamiento de los fallos. Así mismo, incluye una función para el análisis estadístico de los datos de fallos almacenados por el propio sistema, con el objetivo de proporcionar capacidades de mantenimiento predictivo a los sistemas del entorno. Para la implementación del modelo del Entorno de Mantenimiento Centralizado se han utilizado recursos de comunicaciones vía TCP/IP, modelización y almacenamiento de datos en ficheros XML y generación automática de informes en HTML. ABSTRACT. Currently several industries are developing or are making use of multi system platforms. These platforms are composed by many complex systems. The centralized maintenance allows the maintenance optimization, integrating a maintenance management system. This system is in charge of managing the maintenance dialog with the different and multiple platforms. This Master Final Project (TFM) develops the centralized maintenance concept for platforms integrated by modular and complex systems. This TFM is based on the demand of the industry that uses or develops multi system platforms, as aeronautic, railway, and automotive industries. In this way, this TFM covers and analyzes several aspects of the centralized maintenance systems like the State of the Art, for several industries. Besides this work develops different systems architecture types, maintenance techniques, and techniques and systems based on Built-in-test Equipment functions. Additionally, this TFM includes a LabVIEW Centralized System Environment model. This model is composed by a Standard System, the Centralized Maintenance System and the corresponding interfaces. Several diagnostic and fault isolation functions are integrated on the Centralized Maintenance Systems, as well a statistic analysis function, that provides with predictive maintenance capacity, based on the failure data stored by the system. Among others, the following resources have been used for the Centralized System Environment model development: TCP/IP communications, XML file data modelization and storing, and also automatic HTML reports generation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Damages -reduced in fruit packing lines is a major cause of grace reduction and quality loos in fresh marks: fruit. Fruit must be treated gently during in sir handling to improve their qualityin order to get a good price in a competitive market. The correct post-hardvest handling in fruit packing lines is a prerequisite to cut down the heavy post-harvest losses. Fruit packing lines must be evaluated, studying their design, the impacts applied to the fruits, the characteristics of the materials, etc. This study establishes the possibility of carrying out modifications and tests in a packing line during a long period of time. For this purpose, an experimental fruit packing line has been designed and located in the Agricultural Engineering Department of the Polythecnic University of Madrid with the aim of improving mechanical devices and fruit handling conditions to minimize damage to fruit. The experimental line consists of several transporting belts, one rollers transporter, one sizer, one elevator, one singularizer, and three trays to receive the calibrated fruit. The line has a length of 6.15 m and a width cf 1.9 m. Movement of the different components is regulated by electric motors with variable velocity electronically controlled. The height of the transfer points is variable and can be easily modified. The experimental line has been calibrated using two instrumented spheres IS 100 (8.8 cm Ø and6.2cm Ø). Average acceleration values obtained in all the transfers of the experimental line lay under 80 g's, although there is big variation for some of them being some values above 100 g's.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

After construction of the LYSS (Light cYcling Stressing Source) in early 2014, several CPV receivers, with and without secondary optical element (SOE) have been aged under fast transient illumination cycling,. The test plan for Madrid consisted of 50000 cycles. Receivers with poor heat spreaders showed low reliability but those with thicker metal layers passed the test well. The operation of LYSS along 8 months, after more than 250000 cycles, did not show any significant failure, except lamp reposition every 120 hours, in average. The equipment seems valid for unveiling weak receiver designs with respect to intensive illumination, in steady and transient modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Doctoral Thesis entitled Contribution to the analysis, design and assessment of compact antenna test ranges at millimeter wavelengths aims to deepen the knowledge of a particular antenna measurement system: the compact range, operating in the frequency bands of millimeter wavelengths. The thesis has been developed at Radiation Group (GR), an antenna laboratory which belongs to the Signals, Systems and Radiocommunications department (SSR), from Technical University of Madrid (UPM). The Radiation Group owns an extensive experience on antenna measurements, running at present four facilities which operate in different configurations: Gregorian compact antenna test range, spherical near field, planar near field and semianechoic arch system. The research work performed in line with this thesis contributes the knowledge of the first measurement configuration at higher frequencies, beyond the microwaves region where Radiation Group features customer-level performance. To reach this high level purpose, a set of scientific tasks were sequentially carried out. Those are succinctly described in the subsequent paragraphs. A first step dealed with the State of Art review. The study of scientific literature dealed with the analysis of measurement practices in compact antenna test ranges in addition with the particularities of millimeter wavelength technologies. Joint study of both fields of knowledge converged, when this measurement facilities are of interest, in a series of technological challenges which become serious bottlenecks at different stages: analysis, design and assessment. Thirdly after the overview study, focus was set on Electromagnetic analysis algorithms. These formulations allow to approach certain electromagnetic features of interest, such as field distribution phase or stray signal analysis of particular structures when they interact with electromagnetic waves sources. Properly operated, a CATR facility features electromagnetic waves collimation optics which are large, in terms of wavelengths. Accordingly, the electromagnetic analysis tasks introduce an extense number of mathematic unknowns which grow with frequency, following different polynomic order laws depending on the used algorithmia. In particular, the optics configuration which was of our interest consisted on the reflection type serrated edge collimator. The analysis of these devices requires a flexible handling of almost arbitrary scattering geometries, becoming this flexibility the nucleus of the algorithmia’s ability to perform the subsequent design tasks. This thesis’ contribution to this field of knowledge consisted on reaching a formulation which was powerful at the same time when dealing with various analysis geometries and computationally speaking. Two algorithmia were developed. While based on the same principle of hybridization, they reached different order Physics performance at the cost of the computational efficiency. Inter-comparison of their CATR design capabilities was performed, reaching both qualitative as well as quantitative conclusions on their scope. In third place, interest was shifted from analysis - design tasks towards range assessment. Millimetre wavelengths imply strict mechanical tolerances and fine setup adjustment. In addition, the large number of unknowns issue already faced in the analysis stage appears as well in the on chamber field probing stage. Natural decrease of dynamic range available by semiconductor millimeter waves sources requires in addition larger integration times at each probing point. These peculiarities increase exponentially the difficulty of performing assessment processes in CATR facilities beyond microwaves. The bottleneck becomes so tight that it compromises the range characterization beyond a certain limit frequency which typically lies on the lowest segment of millimeter wavelength frequencies. However the value of range assessment moves, on the contrary, towards the highest segment. This thesis contributes this technological scenario developing quiet zone probing techniques which achieves substantial data reduction ratii. Collaterally, it increases the robustness of the results to noise, which is a virtual rise of the setup’s available dynamic range. In fourth place, the environmental sensitivity of millimeter wavelengths issue was approached. It is well known the drifts of electromagnetic experiments due to the dependance of the re sults with respect to the surrounding environment. This feature relegates many industrial practices of microwave frequencies to the experimental stage, at millimeter wavelengths. In particular, evolution of the atmosphere within acceptable conditioning bounds redounds in drift phenomena which completely mask the experimental results. The contribution of this thesis on this aspect consists on modeling electrically the indoor atmosphere existing in a CATR, as a function of environmental variables which affect the range’s performance. A simple model was developed, being able to handle high level phenomena, such as feed - probe phase drift as a function of low level magnitudes easy to be sampled: relative humidity and temperature. With this model, environmental compensation can be performed and chamber conditioning is automatically extended towards higher frequencies. Therefore, the purpose of this thesis is to go further into the knowledge of millimetre wavelengths involving compact antenna test ranges. This knowledge is dosified through the sequential stages of a CATR conception, form early low level electromagnetic analysis towards the assessment of an operative facility, stages for each one of which nowadays bottleneck phenomena exist and seriously compromise the antenna measurement practices at millimeter wavelengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los polímeros armados con fibras (FRP) se utilizan en refuerzos de estructuras de hormigón debido sobre todo a sus excelentes propiedades mecánicas, su resistencia a la corrosión y a su ligereza que se traduce en facilidad y ahorro en el transporte, puesta en obra y aplicación, la cual se realiza de forma muy rápida, con pocos operarios y utilizando medios auxiliares ligeros, minimizándose las interrupciones del uso de la estructura y las molestias a los usuarios. Las razones presentadas anteriormente, han despertado un gran inter´es por parte de diferentes grupos de investigación a nivel mundial y que actualmente se encuentran desarrollando nuevas técnicas de aplicación y métodos de cálculo. Sin embargo, las investigaciones realizadas hasta la fecha, muestran un procedimiento bien definido y aceptado en lo referente al cálculo a flexión, lo cual no ocurre con el refuerzo a cortante y aunque se ha demostrado que el refuerzo con FRP es un sistema eficaz para incrementar la capacidad ´ultima frente a esfuerzos cortantes, también se pone de manifiesto la necesidad de más estudios experimentales y teóricos para avanzar en el entendimiento de los mecanismos involucrados para este tipo de refuerzo y establecer un procedimiento de diseño apropiado que maximice las excelentes propiedades de este material. Los modelos que explican el comportamiento del refuerzo a cortante de elementos de hormigón armado son complejos y sin transposición directa a fórmulas ingenieriles. Las normas actualmente en vigor, generalmente, establecen empíricamente la capacidad cortante como la suma de las capacidades del hormigón y el refuerzo transversal de acero. Cuando un elemento es reforzado externamente con FRP, los modelos son evidentemente aun más complejos. Las guías y recomendaciones existentes proponen calcular la capacidad del elemento añadiendo la resistencia aportada por el refuerzo externo de FRP a la ya dada por el hormigón y acero transversal. Sin embargo, la idoneidad de este acercamiento es cuestionable puesto que no tiene en cuenta una posible interacción entre refuerzos. Con base en lo anterior se da origen al tema objeto de este trabajo, el cual está orientado al estudio a cortante de elementos de hormigón armado (HA), reforzados externamente con material compuesto de tejido unidireccional de fibra de carbono y resina epoxi. Inicialmente se hace una completa revisión del estado actual del conocimiento de la resistencia a cortante en elementos de hormigón armado con y sin refuerzo externo de FRP, prestando especial atención en los mecanismos actuantes estudiados hasta la fecha. La bibliografía consultada ha sido exhaustiva y actualizada lo que ha permitido el estudio de los modelos propuestos más importantes, tanto para la descripción del fenómeno de adherencia entre hormigón-FRP como de la valoración del aporte al cortante total hecho por el FRP, a través de sendas bases de datos de ensayos de pull-out y de vigas de hormigón armado ensayadas a cortante. Con base en todo lo anterior, se expusieron los mecanismos actuantes en el aporte a cortante hecho por el FRP en elementos de hormigón armado y la forma como las principales guías de cálculo existentes hasta la fecha los abordan. De igual forma se define un modelo de resistencia de esfuerzos para el FRP y se proponen dos modelos para el cálculo de las tensiones o deformaciones efectivas, de los cuales uno esta basado en el modelo de adherencia propuesto por Oller (2005) y el otro en una regresión multivariante para los mecanismos expuestos. Como complemento del estudio de los trabajos encontrados en la literatura, se lleva acabo un programa experimental que, además de aportar más registros a la exigua base de datos existentes, aporte mayor luz a los puntos que se consideran están deficientemente resueltos. Dentro de este programa se realizaron 32 ensayos sobre 16 vigas de 4.5 m de longitud (dos ensayos por viga), reforzadas a cortante con tejido unidireccional de CFRP. Finalmente, estos estudios han permitido proponer modificaciones a las formulaciones existentes en los códigos y guías en vigor. Abstract Its excellent mechanical properties, as well as its corrosion resistance and light weight, which make it easy to apply and inexpensive to ship to the worksite, are the basis of the extended use of fiber reinforced polymer (FRP) as external strengthening for structures. FRP strengthening is a rapid operation calling for only limited labor and lightweight ancillary equipment, all of which minimizes both the interruption of facility usage and user inconvenience. These advantages have aroused considerable interest in civil engineering science and technology and have led to countless applications the world over. Research studies on the shear strength of FRP-strengthened members have been much fewer in number and more controversial than the research on flexural strengthening, for which a more or less standardized and generally accepted procedure has been established. The research conducted and a host of applications around the world have shown that FRP strengthening is an effective technique for raising ultimate shear strength, but it has also revealed a need for further experimental and theoretical research to advance in the understanding of the mechanisms involved and establish suitable design procedures that optimize the excellent properties of this material The models that explain reinforced concrete (RC) shear strength behavior are complex and cannot be directly transposed to engineering formulas. The standards presently in place generally establish shear capacity empirically as the sum of the capacities of the concrete and the passive reinforcement. When members are externally strengthened with FRP, the models are obviously even more complex. The existing guides and recommendations propose calculating capacity by adding the external strength provided by the FRP to the contributions of the concrete and passive reinforcement. The suitability of this approach is questionable, however, because it fails to consider the interaction between passive reinforcement and external strengthening. The subject of this work is based in above, which is focused on externally shear strengthening for reinforced concrete members with unidirectional carbon fiber sheets bonded with epoxy resin. v Initially a thorough literature review on shear of reinforced concrete beams with and without external FRP strengthening was performed, paying special attention to the acting mechanisms studied to date, which allowed the study of the most important models both to describe the bond phenomenon as well as calculating the FRP shear contribution, through separate databases of pull-out tests and shear tests on reinforced concrete beams externally strengthened with FRP. Based on above, they were exposed the acting mechanisms in a FRP shear strengthening on reinforced concrete beams and how guidelines deal the topic. The same way, it is defined a FRP stress strength model and two more models are proposed for calculating the effective stress, one of these is based on the Oller (2005) bond model and another one is the data best fit, taking into account most of the acting mechanisms. To complement the theoretical part we develop an experimental program that, in addition to providing more records to the meager existing database provide greater understanding to the points considered poorly resolved. The test program included 32 tests of 16 beams (2 per beam) of 4.5 m long, shear strengthened with FRP, externally. Finally, modifications to the existing codes and guidelines are proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of three different aging methods (immersion in hot water, freeze–thaw cycles and wet–dry cycles) on the mechanical properties of GRC were studied and compared. Test results showed that immersion in hot water may be an unreliable method for modified GRC formulations, with it being in probability a very harmful procedure. A new aging method, mixing freeze–thaw cycles and wet–dry cycles, seems to be the most accurate simulation of weather conditions that produce a noticeable change in GRC mechanical properties. Future work should be carried out to find a correlation between real weather and the proposed aging method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Following the success achieved in previous research projects usin non-destructive methods to estimate the physical and mechanical aging of particle and fibre boards, this paper studies the relationships between aging, physical and mechanical changes, using non-destructive measurements of oriented strand board (OSB). 184 pieces of OSB board from a French source were tested to analyze its actual physical and mechanical properties. The same properties were estimated using acoustic non-destructive methods (ultrasound and stress wave velocity) during a physical laboratory aging test. Measurements were recorded of propagation wave velocity with the sensors aligned, edge to edge, and forming an angle of 45 degrees, with both sensors on the same face of the board. This is because aligned measures are not possible on site. The velocity results are always higher in 45 degree measurements. Given the results of statistical analysis, it can be concluded that there is a strong relationship between acoustic measurements and the decline in physical and mechanical properties of the panels due to aging. The authors propose several models to estimate the physical and mechanical properties of board, as well as their degree of aging. The best results are obtained using ultrasound, although the difference in comparison with the stress wave method is not very significant. A reliable prediction of the degree of deterioration (aging) of board is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

EWT back contact solar cells are manufactured from very thin silicon wafers. These wafers are drilled by means of a laser process creating a matrix of tiny holes with a density of approximately 125 holes per square centimeter. Their influence in the stiffness and mechanical strength has been studied. To this end, both wafers with and without holes have been tested with the ring on ring test. Numerical simulations of the tests have been carried out through the Finite Element Method taking into account the non-linearities present in the tests. It's shown that one may use coarse meshes without holes to simulate the test and after that sub models are used for the estimation of the stress concentration around the holes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical stability of EWT solar cells deteriorates when holes are created in the wafer. Nevertheless, the chemical etching after the hole generation process improves the mechanical strength by removing part of the damage produced in the drilling process. Several sets of wafers with alkaline baths of different duration have been prepared. The mechanical strength has been measured by the ring on ring bending test and the failure stresses have been obtained through a FE simulation of the test. This paper shows the comparison of these groups of wafers in order to obtain an optimum value of the decreased thickness produced by the chemical etching

Relevância:

30.00% 30.00%

Publicador:

Resumo:

EWT solar cells start from drilled wafers with approximately 100 holes/cm2. These holes act as stress concentrators leading to a reduction in the mechanical strength of this type of wafers. The viability of cells with higher density of holes has been studied. To this end, sets of wafers with different density of holes have been characterized. The ring on ring test has been employed and FE models have been developed to simulate the test. The statistical evaluation permits to draw conclusions about the reduction of the strength depending on the density of holes. Moreover, the stress concentration around the holes has been studied by means of the FE method employing the sub-modeling technique. The maximum principal stress of EWT wafers with twice the density of holes of commercial ones is almost the same. However, the mutual interaction between the stress concentration effects around neighboring holes is only observed for wafers with a density of 200 holes/cm2