23 resultados para Measurement system

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Structural health monitoring (SHM) systems have excellent potential to improve the regular operation and maintenance of structures. Wireless networks (WNs) have been used to avoid the high cost of traditional generic wired systems. The most important limitation of SHM wireless systems is time-synchronization accuracy, scalability, and reliability. A complete wireless system for structural identification under environmental load is designed, implemented, deployed, and tested on three different real bridges. Our contribution ranges from the hardware to the graphical front end. System goal is to avoid the main limitations of WNs for SHM particularly in regard to reliability, scalability, and synchronization. We reduce spatial jitter to 125 ns, far below the 120 μs required for high-precision acquisition systems and much better than the 10-μs current solutions, without adding complexity. The system is scalable to a large number of nodes to allow for dense sensor coverage of real-world structures, only limited by a compromise between measurement length and mandatory time to obtain the final result. The system addresses a myriad of problems encountered in a real deployment under difficult conditions, rather than a simulation or laboratory test bed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Metrological confirmation process must be designed and implemented to ensure that metrological characteristics of the measurement system meet metrological requirements of the measurement process. The aim of this paper is to present an alternative method to the traditional metrological requirements about the relationship between tolerance and measurement uncertainty, to develop such confirmation processes. The proposed way to metrological confirmation considers a given inspection task of the measurement process into the manufacturing system, and it is based on the Index of Contamination of the Capability, ICC. Metrological confirmation process is then developed taking into account the producer risks and economic considerations on this index. As a consequence, depending on the capability of the manufacturing process, the measurement system will be or will not be in adequate state of metrological confirmation for the measurement process.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

So far, the majority of reports on on-line measurement considered soil properties with direct spectral responses in near infrared spectroscopy (NIRS). This work reports on the results of on-line measurement of soil properties with indirect spectral responses, e.g. pH, cation exchange capacity (CEC), exchangeable calcium (Caex) and exchangeable magnesium (Mgex) in one field in Bedfordshire in the UK. The on-line sensor consisted of a subsoiler coupled with an AgroSpec mobile, fibre type, visible and near infrared (vis–NIR) spectrophotometer (tec5 Technology for Spectroscopy, Germany), with a measurement range 305–2200 nm to acquire soil spectra in diffuse reflectance mode. General calibration models for the studied soil properties were developed with a partial least squares regression (PLSR) with one-leave-out cross validation, using spectra measured under non-mobile laboratory conditions of 160 soil samples collected from different fields in four farms in Europe, namely, Czech Republic, Denmark, Netherland and UK. A group of 25 samples independent from the calibration set was used as independent validation set. Higher accuracy was obtained for laboratory scanning as compared to on-line scanning of the 25 independent samples. The prediction accuracy for the laboratory and on-line measurements was classified as excellent/very good for pH (RPD = 2.69 and 2.14 and r2 = 0.86 and 0.78, respectively), and moderately good for CEC (RPD = 1.77 and 1.61 and r2 = 0.68 and 0.62, respectively) and Mgex (RPD = 1.72 and 1.49 and r2 = 0.66 and 0.67, respectively). For Caex, very good accuracy was calculated for laboratory method (RPD = 2.19 and r2 = 0.86), as compared to the poor accuracy reported for the on-line method (RPD = 1.30 and r2 = 0.61). The ability of collecting large number of data points per field area (about 12,800 point per 21 ha) and the simultaneous analysis of several soil properties without direct spectral response in the NIR range at relatively high operational speed and appreciable accuracy, encourage the recommendation of the on-line measurement system for site specific fertilisation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a new methodology for measurement of the instantaneous average exhaust mass flow rate in reciprocating internal combustion engines to be used to determinate real driving emissions on light duty vehicles, as part of a Portable Emission Measurement System (PEMS). Firstly a flow meter, named MIVECO flow meter, was designed based on a Pitot tube adapted to exhaust gases which are characterized by moisture and particle content, rapid changes in flow rate and chemical composition, pulsating and reverse flow at very low engine speed. Then, an off-line methodology was developed to calculate the instantaneous average flow, considering the ?square root error? phenomenon. The paper includes the theoretical fundamentals, the developed flow meter specifications, the calibration tests, the description of the proposed off-line methodology and the results of the validation test carried out in a chassis dynamometer, where the validity of the mass flow meter and the methodology developed are demonstrated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This Doctoral Thesis entitled Contribution to the analysis, design and assessment of compact antenna test ranges at millimeter wavelengths aims to deepen the knowledge of a particular antenna measurement system: the compact range, operating in the frequency bands of millimeter wavelengths. The thesis has been developed at Radiation Group (GR), an antenna laboratory which belongs to the Signals, Systems and Radiocommunications department (SSR), from Technical University of Madrid (UPM). The Radiation Group owns an extensive experience on antenna measurements, running at present four facilities which operate in different configurations: Gregorian compact antenna test range, spherical near field, planar near field and semianechoic arch system. The research work performed in line with this thesis contributes the knowledge of the first measurement configuration at higher frequencies, beyond the microwaves region where Radiation Group features customer-level performance. To reach this high level purpose, a set of scientific tasks were sequentially carried out. Those are succinctly described in the subsequent paragraphs. A first step dealed with the State of Art review. The study of scientific literature dealed with the analysis of measurement practices in compact antenna test ranges in addition with the particularities of millimeter wavelength technologies. Joint study of both fields of knowledge converged, when this measurement facilities are of interest, in a series of technological challenges which become serious bottlenecks at different stages: analysis, design and assessment. Thirdly after the overview study, focus was set on Electromagnetic analysis algorithms. These formulations allow to approach certain electromagnetic features of interest, such as field distribution phase or stray signal analysis of particular structures when they interact with electromagnetic waves sources. Properly operated, a CATR facility features electromagnetic waves collimation optics which are large, in terms of wavelengths. Accordingly, the electromagnetic analysis tasks introduce an extense number of mathematic unknowns which grow with frequency, following different polynomic order laws depending on the used algorithmia. In particular, the optics configuration which was of our interest consisted on the reflection type serrated edge collimator. The analysis of these devices requires a flexible handling of almost arbitrary scattering geometries, becoming this flexibility the nucleus of the algorithmia’s ability to perform the subsequent design tasks. This thesis’ contribution to this field of knowledge consisted on reaching a formulation which was powerful at the same time when dealing with various analysis geometries and computationally speaking. Two algorithmia were developed. While based on the same principle of hybridization, they reached different order Physics performance at the cost of the computational efficiency. Inter-comparison of their CATR design capabilities was performed, reaching both qualitative as well as quantitative conclusions on their scope. In third place, interest was shifted from analysis - design tasks towards range assessment. Millimetre wavelengths imply strict mechanical tolerances and fine setup adjustment. In addition, the large number of unknowns issue already faced in the analysis stage appears as well in the on chamber field probing stage. Natural decrease of dynamic range available by semiconductor millimeter waves sources requires in addition larger integration times at each probing point. These peculiarities increase exponentially the difficulty of performing assessment processes in CATR facilities beyond microwaves. The bottleneck becomes so tight that it compromises the range characterization beyond a certain limit frequency which typically lies on the lowest segment of millimeter wavelength frequencies. However the value of range assessment moves, on the contrary, towards the highest segment. This thesis contributes this technological scenario developing quiet zone probing techniques which achieves substantial data reduction ratii. Collaterally, it increases the robustness of the results to noise, which is a virtual rise of the setup’s available dynamic range. In fourth place, the environmental sensitivity of millimeter wavelengths issue was approached. It is well known the drifts of electromagnetic experiments due to the dependance of the re sults with respect to the surrounding environment. This feature relegates many industrial practices of microwave frequencies to the experimental stage, at millimeter wavelengths. In particular, evolution of the atmosphere within acceptable conditioning bounds redounds in drift phenomena which completely mask the experimental results. The contribution of this thesis on this aspect consists on modeling electrically the indoor atmosphere existing in a CATR, as a function of environmental variables which affect the range’s performance. A simple model was developed, being able to handle high level phenomena, such as feed - probe phase drift as a function of low level magnitudes easy to be sampled: relative humidity and temperature. With this model, environmental compensation can be performed and chamber conditioning is automatically extended towards higher frequencies. Therefore, the purpose of this thesis is to go further into the knowledge of millimetre wavelengths involving compact antenna test ranges. This knowledge is dosified through the sequential stages of a CATR conception, form early low level electromagnetic analysis towards the assessment of an operative facility, stages for each one of which nowadays bottleneck phenomena exist and seriously compromise the antenna measurement practices at millimeter wavelengths.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The contributions of driver behaviour as well as surrounding infrastructure are decisive on pollutant emissions from vehicles in real traffic situations. This article deals with the preliminary study of the interaction between the dynamic variables recorded in a vehicle (driving pattern) and pollutant emissions produced over a given urban route. It has been established a “dynamic performance index”-DPI, which is calculated from some driving pattern parameters, which in turn depends on traffic congestion level and route characteristics, in order to determine whether the driving has been aggressive, normal or calm. Two passenger cars instrumented with a portable activity measurement system -to record dynamic variables- and on-board emission measurement equipment have been used. This study has shown that smooth driving patterns can reduce up to 80% NOX emissions and up to 20% of fuel in the same route

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a method for the identification of different partial discharges (PDs) sources through the analysis of a collection of PD signals acquired with a PD measurement system. This method, robust and sensitive enough to cope with noisy data and external interferences, combines the characterization of each signal from the collection, with a clustering procedure, the CLARA algorithm. Several features are proposed for the characterization of the signals, being the wavelet variances, the frequency estimated with the Prony method, and the energy, the most relevant for the performance of the clustering procedure. The result of the unsupervised classification is a set of clusters each containing those signals which are more similar to each other than to those in other clusters. The analysis of the classification results permits both the identification of different PD sources and the discrimination between original PD signals, reflections, noise and external interferences. The methods and graphical tools detailed in this paper have been coded and published as a contributed package of the R environment under a GNU/GPL license.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

streets in local residential areas in large cities, real traffic tests for pollutant emissions and fuel consumption have been carried out in Madrid city centre. Emission concentration and car activity were simultaneously measured by a Portable Emissions Measurement System. Real life tests carried out at different times and on different days were performed with a turbo-diesel engine light vehicle equipped with an oxidizer catalyst and using different driving styles with a previously trained driver. The results show that by reducing the speed limit from 50 km h-1 to 30 km h-1, using a normal driving style, the time taken for a given trip does not increase, but fuel consumption and NOx, CO and PM emissions are clearly reduced. Therefore, the main conclusion of this work is that reducing the speed limit in some narrow streets in residential and commercial areas or in a city not only increases pedestrian safety, but also contributes to reducing the environmental impact of motor vehicles and reducing fuel consumption. In addition, there is also a reduction in the greenhouse gas emissions resulting from the combustion of the fuel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La corrosión bajo tensiones (SCC) es un problema de gran importancia en las aleaciones de aluminio de máxima resistencia (serie Al-Zn-Mg-Cu). La utilización de tratamientos térmicos sobremadurados, en particular el T73, ha conseguido prácticamente eliminar la susceptibilidad a corrosión bajo tensiones en dichas aleaciones pero a costa de reducir su resistencia mecánica. Desde entonces se ha tratado de optimizar simultáneamente ambos comportamientos, encontrándose para ello diversos inconvenientes entre los que destacan: la dificultad de medir experimentalmente el crecimiento de grieta por SCC, y el desconocimiento de las causas y el mecanismo por el cual se produce la SCC. Los objetivos de esta Tesis son mejorar el sistema de medición de grietas y profundizar en el conocimiento de la SCC, con el fin de obtener tratamientos térmicos que aúnen un óptimo comportamiento tanto en SCC como mecánico en las aleaciones de aluminio de máxima resistencia utilizadas en aeronáutica. Para conseguir los objetivos anteriormente descritos se han realizado unos cuarenta tratamientos térmicos diferentes, de los cuales la gran mayoría son nuevos, para profundizar en el conocimiento de la influencia de la microestructura (fundamentalmente, de los precipitados coherentes) en el comportamiento de las aleaciones Al-Zn-Mg-Cu, y estudiar la viabilidad de nuevos tratamientos apoyados en el conocimiento adquirido. Con el fin de obtener unos resultados aplicables a productos o semiproductos de aplicación aeronáutica, los tratamientos térmicos se han realizado a trozos grandes de una plancha de 30 mm de espesor de la aleación de aluminio 7475, muy utilizada en las estructuras aeronáuticas. Asimismo con el objeto de conseguir una mayor fiabilidad de los resultados obtenidos se han utilizado, normalmente, tres probetas de cada tratamiento para los diferentes ensayos realizados. Para la caracterización de dichos tratamientos se han utilizado diversas técnicas: medida de dureza y conductividad eléctrica, ensayos de tracción, calorimetría diferencial de barrido (DSC), metalografía, fractografía, microscopia electrónica de transmisión (MET) y de barrido (MEB), y ensayos de crecimiento de grieta en probeta DCB, que a su vez han permitido hacer una estimación del comportamiento en tenacidad del material. Las principales conclusiones del estudio realizado se pueden resumir en las siguientes: Se han diseñado y desarrollado nuevos métodos de medición de grieta basados en el empleo de la técnica de ultrasonidos, que permiten medir el crecimiento de grieta por corrosión bajo tensiones con la precisión y fiabilidad necesarias para valorar adecuadamente la susceptibilidad a corrosión bajo tensiones. La mejora de medida de la posición del frente de grieta ha dado lugar, entre otras cosas, a la definición de un nuevo ensayo a iniciación en probetas preagrietadas. Asimismo, se ha deducido una nueva ecuación que permite calcular el factor de intensidad de tensiones existente en punta de grieta en probetas DCB teniendo en cuenta la influencia de la desviación del plano de crecimiento de la grieta del plano medio de la probeta. Este aspecto ha sido determinante para poder explicar los resultados experimentales obtenidos ya que el crecimiento de la grieta por un plano paralelo al plano medio de la probeta DCB pero alejado de él reduce notablemente el factor de intensidades de tensiones que actúa en punta de grieta y modifica las condiciones reales del ensayo. Por otro lado, se han identificado los diferentes constituyentes de la microestructura de precipitación de todos los tratamientos térmicos estudiados y, en especial, se ha conseguido constatar (mediante MET y DSC) la existencia de zonas de Guinier-Preston del tipo GP(II) en la microestructura de numerosos tratamientos térmicos (no descrita en la bibliografía para las aleaciones del tipo de la estudiada) lo que ha permitido establecer una nueva interpretación de la evolución de la microestructura en los diferentes tratamientos. Al hilo de lo anterior, se han definido nuevas secuencias de precipitación para este tipo de aleaciones, que han permitido entender mejor la constitución de la microestructura y su relación con las propiedades en los diferentes tratamientos térmicos estudiados. De igual manera, se ha explicado el papel de los diferentes microconstituyentes en diversas propiedades mecánicas (propiedades a tracción, dureza y tenacidad KIa); en particular, el estudio realizado de la relación de la microestructura con la tenacidad KIa es inédito. Por otra parte, se ha correlacionado el comportamiento en corrosión bajo tensiones, tanto en la etapa de incubación de grieta como en la de propagación, con las características medidas de los diferentes constituyentes microestructurales de los tratamientos térmicos ensayados, tanto de interior como de límite de grano, habiéndose obtenido que la microestructura de interior de grano tiene una mayor influencia en el comportamiento en corrosión bajo tensiones que la de límite de grano. De forma especial, se ha establecido la importancia capital, y muy negativa, de la presencia en la microestructura de zonas de Guinier-Preston en el crecimiento de la grieta por corrosión bajo tensiones. Finalmente, como consecuencia de todo lo anterior, se ha propuesto un nuevo mecanismo por el que se produce la corrosión bajo tensiones en este tipo de aleaciones de aluminio, y que de forma muy resumida se puede concretar lo siguiente: la acumulación de hidrógeno (formado, básicamente, por un proceso corrosivo de disolución anódica) delante de la zonas GP (en especial, de las zonas GP(I)) próximas a la zona libre de precipitados que se desarrolla alrededor del límite de grano provoca enfragilización local y causa el rápido crecimiento de grieta característico de algunos tratamientos térmicos de este tipo de aleaciones. ABSTRACT The stress corrosion cracking (SCC) is a major problem in the aluminum alloys of high resistance (series Al-Zn-Mg-Cu). The use of overaged heat treatments, particularly T73 has achieved virtually eliminate the susceptibility to stress corrosion cracking in such alloys but at the expense of reducing its mechanical strength. Since then we have tried to simultaneously optimize both behaviors, several drawbacks found for it among them: the difficulty of measuring experimentally the SCC crack growth, and ignorance of the causes and the mechanism by which SCC occurs. The objectives of this thesis are to improve the measurement system of cracks and deeper understanding of the SCC, in order to obtain heat treatments that combine optimum performance in both SCC and maximum mechanical strength in aluminum alloys used in aerospace To achieve the above objectives have been made about forty different heat treatments, of which the vast majority are new, to deepen the understanding of the influence of microstructure (mainly of coherent precipitates) in the behavior of the alloys Al -Zn-Mg-Cu, and study the feasibility of new treatments supported by the knowledge gained. To obtain results for products or semi-finished aircraft application, heat treatments were performed at a large pieces plate 30 mm thick aluminum alloy 7475, widely used in aeronautical structures. Also in order to achieve greater reliability of the results obtained have been used, normally, three specimens of each treatment for various tests. For the characterization of these treatments have been used several techniques: measurement of hardness and electrical conductivity, tensile testing, differential scanning calorimetry (DSC), metallography, fractography, transmission (TEM) and scanning (SEM) electron microscopy, and crack growth tests on DCB specimen, which in turn have allowed to estimate the behavior of the material in fracture toughness. The main conclusions of the study can be summarized as follows: We have designed and developed new methods for measuring crack based on the use of the ultrasound technique, for measuring the growth of stress corrosion cracks with the accuracy and reliability needed to adequately assess the susceptibility to stress corrosion. Improved position measurement of the crack front has resulted, among other things, the definition of a new initiation essay in pre cracked specimens. Also, it has been inferred a new equation to calculate the stress intensity factor in crack tip existing in DCB specimens considering the influence of the deviation of the plane of the crack growth of the medium plane of the specimen. This has been crucial to explain the experimental results obtained since the crack growth by a plane parallel to the medium plane of the DCB specimen but away from it greatly reduces the stress intensity factor acting on the crack tip and modifies the actual conditions of the essay. Furthermore, we have identified the various constituents of the precipitation microstructure of all heat treatments studied and, in particular note has been achieved (by TEM and DSC) the existence of the type GP (II) of Guinier-Preston zones in the microstructure of several heat treatments (not described in the literature for alloys of the type studied) making it possible to establish a new interpretation of the evolution of the microstructure in the different treatments. In line with the above, we have defined new precipitation sequences for these alloys, which have allowed a better understanding of the formation of the microstructure in relation to the properties of different heat treatments studied. Similarly, explained the role of different microconstituents in various mechanical properties (tensile properties, hardness and toughness KIa), in particular, the study of the relationship between the tenacity KIa microstructure is unpublished. Moreover, has been correlated to the stress corrosion behavior, both in the incubation step as the crack propagation, with the measured characteristics of the various microstructural constituents heat treatments tested, both interior and boundary grain, having obtained the internal microstructure of grain has a greater influence on the stress corrosion cracking behavior in the grain boundary. In a special way, has established the importance, and very negative, the presence in the microstructure of Guinier-Preston zones in crack growth by stress corrosion. Finally, following the above, we have proposed a new mechanism by which stress corrosion cracking occurs in this type of aluminum alloy, and, very briefly, one can specify the following: the accumulation of hydrogen (formed basically by a corrosive process of anodic dissolution) in front of the GP zones (especially the GP (I) zones) near the precipitates free zone that develops around grain boundary causes local embrittlement which characterizes rapid crack growth of some heat treatments such alloys.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este proyecto fin de carrera tiene como finalidad el diseño e implementación de un sistema multicanal de medida de temperaturas con termopares con procesado digital. Se ha realizado un prototipo de cuatro canales con conexión de termopar, que es el tipo de sensor utilizado para realizar dichas medidas. La tensión generada por el termopar es procesada mediante un conversor de termopar a digital con salida en interfaz modo serie o SPI (Serial Peripheral Interface). El control de dicha comunicación se realiza por medio de un Array de Puertas Lógicas Programables o FPGA (Field Programmable Gate Array), en concreto se ha utilizado una plataforma de desarrollo modelo Virtex-5 de la empresa Xilinx. Esta tarjeta se ha programado también para el procesado software y la posterior comunicación serie con el PC, el cual consta de una interfaz de usuario donde se muestran los resultados de las medidas en tiempo real. El proyecto ha sido desarrollado en colaboración con una empresa privada dedicada principalmente al diseño electrónico. La finalidad de este prototipo es el estudio de una actualización del bloque de medida para el control de las curvas de temperatura de un equipo de reparación aeronáutica. En esta memoria se describe el proceso realizado para el desarrollo del prototipo, incluye la presentación de los estudios realizados y la información necesaria para llevar a cabo el diseño, la fabricación y la programación de los diferentes bloques que componen el sistema. ABSTRACT. The aim of this project is to implement a multichannel temperature measurement system with digital processing, using thermocouples. A four-channel prototype with thermocouple connection has been built. The thermocouple voltage is converted to digital line using a Thermocouple-to-Digital Converter with a Serial Perpheral Interface (SPI) output. The master which controls this communication is embedded in a Field Programmable Gate Array (FPGA), specifically the Xilinx Virtex-5 model. This FPGA also has the code for software temperature processing and the prototype to PC serial communication embedded. The PC user interface displays the measurement results in real time. This project has been developed at a private electronics design company. The company wants to study an update to change the analogue temperature controller equipment to a digital one. So this prototype studies a digital version of the temperature measurement block. The processes accomplished for the prototype development are detailed in the next pages of this document. It includes the studies and information needed to develop the design, manufacturing process and programming of the blocks which integrate with the global system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabajo presenta un estudio sobre el funcionamiento y aplicaciones de las células de combustible de membrana tipo PEM, o de intercambio de protones, alimentadas con hidrógeno puro y oxigeno obtenido de aire comprimido. Una vez evaluado el proceso de dichas células y las variables que intervienen en el mismo, como presión, humedad y temperatura, se presenta una variedad de métodos para la instrumentación de tales variables así como métodos y sistemas para la estabilidad y control de las mismas, en torno a los valores óptimos para una mayor eficacia en el proceso. Tomando como variable principal a controlar la temperatura del proceso, y exponiendo los valores concretos en torno a 80 grados centígrados entre los que debe situarse, es realizado un modelo del proceso de calentamiento y evolución de la temperatura en función de la potencia del calentador resistivo en el dominio de la frecuencia compleja, y a su vez implementado un sistema de medición mediante sensores termopar de tipo K de respuesta casi lineal. La señal medida por los sensores es amplificada de manera diferencial mediante amplificadores de instrumentación INA2126, y es desarrollado un algoritmo de corrección de error de unión fría (error producido por la inclusión de nuevos metales del conector en el efecto termopar). Son incluidos los datos de test referentes al sistema de medición de temperatura , incluyendo las desviaciones o error respecto a los valores ideales de medida. Para la adquisición de datos y implementación de algoritmos de control, es utilizado un PC con el software Labview de National Instruments, que permite una programación intuitiva, versátil y visual, y poder realizar interfaces de usuario gráficas simples. La conexión entre el hardware de instrumentación y control de la célula y el PC se realiza mediante un interface de adquisición de datos USB NI 6800 que cuenta con un amplio número de salidas y entradas analógicas. Una vez digitalizadas las muestras de la señal medida, y corregido el error de unión fría anteriormente apuntado, es implementado en dicho software un controlador de tipo PID ( proporcional-integral-derivativo) , que se presenta como uno de los métodos más adecuados por su simplicidad de programación y su eficacia para el control de este tipo de variables. Para la evaluación del comportamiento del sistema son expuestas simulaciones mediante el software Matlab y Simulink determinando por tanto las mejores estrategias para desarrollar el control PID, así como los posibles resultados del proceso. En cuanto al sistema de calentamiento de los fluidos, es empleado un elemento resistor calentador, cuya potencia es controlada mediante un circuito electrónico compuesto por un detector de cruce por cero de la onda AC de alimentación y un sistema formado por un elemento TRIAC y su circuito de accionamiento. De manera análoga se expone el sistema de instrumentación para la presión de los gases en el circuito, variable que oscila en valores próximos a 3 atmosferas, para ello es empleado un sensor de presión con salida en corriente mediante bucle 4-20 mA, y un convertidor simple corriente a tensión para la entrada al sistema de adquisición de datos. Consecuentemente se presenta el esquema y componentes necesarios para la canalización, calentamiento y humidificación de los gases empleados en el proceso así como la situación de los sensores y actuadores. Por último el trabajo expone la relación de algoritmos desarrollados y un apéndice con información relativa al software Labview. ABTRACT This document presents a study about the operation and applications of PEM fuel cells (Proton exchange membrane fuel cells), fed with pure hydrogen and oxygen obtained from compressed air. Having evaluated the process of these cells and the variables involved on it, such as pressure, humidity and temperature, there is a variety of methods for implementing their control and to set up them around optimal values for greater efficiency in the process. Taking as primary process variable the temperature, and exposing its correct values around 80 degrees centigrade, between which must be placed, is carried out a model of the heating process and the temperature evolution related with the resistive heater power on the complex frequency domain, and is implemented a measuring system with thermocouple sensor type K performing a almost linear response. The differential signal measured by the sensor is amplified through INA2126 instrumentation amplifiers, and is developed a cold junction error correction algorithm (error produced by the inclusion of additional metals of connectors on the thermocouple effect). Data from the test concerning the temperature measurement system are included , including deviations or error regarding the ideal values of measurement. For data acquisition and implementation of control algorithms, is used a PC with LabVIEW software from National Instruments, which makes programming intuitive, versatile, visual, and useful to perform simple user interfaces. The connection between the instrumentation and control hardware of the cell and the PC interface is via a USB data acquisition NI 6800 that has a large number of analog inputs and outputs. Once stored the samples of the measured signal, and correct the error noted above junction, is implemented a software controller PID (proportional-integral-derivative), which is presented as one of the best methods for their programming simplicity and effectiveness for the control of such variables. To evaluate the performance of the system are presented simulations using Matlab and Simulink software thereby determining the best strategies to develop PID control, and possible outcomes of the process. As fluid heating system, is employed a heater resistor element whose power is controlled by an electronic circuit comprising a zero crossing detector of the AC power wave and a system consisting of a Triac and its drive circuit. As made with temperature variable it is developed an instrumentation system for gas pressure in the circuit, variable ranging in values around 3 atmospheres, it is employed a pressure sensor with a current output via 4-20 mA loop, and a single current to voltage converter to adequate the input to the data acquisition system. Consequently is developed the scheme and components needed for circulation, heating and humidification of the gases used in the process as well as the location of sensors and actuators. Finally the document presents the list of algorithms and an appendix with information about Labview software.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La medida de la presión sonora es un proceso de extrema importancia para la ingeniería acústica, de aplicación en numerosas áreas de esta disciplina, como la acústica arquitectónica o el control de ruido. Sobre todo en esta última, es necesario poder efectuar medidas precisas en condiciones muy diversas. Por otra parte, la ubicuidad de los dispositivos móviles inteligentes (smartphones, tabletas, etc.), dispositivos que integran potencia de procesado, conectividad, interactividad y una interfaz intuitiva en un tamaño reducido, abre la posibilidad de su uso como sistemas de medida de calidad y de coste bajo. En este Proyecto se pretende utilizar las capacidades de entrada y salida, procesado, conectividad inalámbrica y geolocalización de los dispositivos móviles basados en iOS, en concreto el iPhone, para implementar un sistema de medidas acústicas que iguale o supere las prestaciones de los sonómetros existentes en el mercado. SonoPhone permitirá, mediante la conexión de un micrófono de medida adecuado, la realización de medidas de acuerdo a las normas técnicas en vigor, así como la posibilidad de programar, configurar y almacenar o trasmitir las medidas realizadas, que además estarán geolocalizadas con el GPS integrado en el dispositivo móvil. También se permitirá enviar los datos de la medida a un almacenamiento remoto en la nube. La aplicación tiene una estructura modular en la que un módulo de adquisición de datos lee la señal del micrófono, un back-end efectúa el procesado necesario, y otros módulos permiten la calibración del dispositivo y programar y configurar las medidas, así como su almacenamiento y transmisión en red. Una interfaz de usuario (GUI) permite visualizar las medidas y efectuar las configuraciones deseadas por el usuario, todo ello en tiempo real. Además de implementar la aplicación, se ha realizado una prueba de funcionamiento para determinar si el hardware del iPhone es adecuado para la medida de la presión acústica de acuerdo a las normas internacionales. Sound pressure measurement is an extremely important process in the field of acoustic engineering, with applications in numerous subfields, like for instance building acoustics and noise control, where it is necessary to be able to accurately measure sound pressure in very diverse (and sometimes adverse) conditions. On the other hand, the growing ubiquity of mobile devices such as smartphones or tablets, which combine processing power, connectivity, interactivity and an intuitive interface in a small size, makes it possible to use these devices as quality low-cost measurement systems. This Project aims to use the input-output capabilities of iOS-based mobile devices, in particular the iPhone, together with their processing power, wireless connectivity and geolocation features, to implement an acoustic measurement system that rivals the performance of existing devices. SonoPhone allows, with the addition of an adequate measurement microphone, to carry out measurements that comply with current technical regulations, as well as programming, configuring, storing and transmitting the results of the measurement. These measurements will be geolocated using the integrated GPS, and can be transmitted effortlessly to a remote cloud storage. The application is structured in modular fashion. A data acquisition module reads the signal from the microphone, while a back-end module carries out the necessary processing. Other modules permit the device to be calibrated, or control the configuration of the measurement and its storage or transmission. A Graphical User Interface (GUI) allows visual feedback on the measurement in progress, and provides the user with real-time control over the measurement parameters. Not only an application has been developed; a laboratory test was carried out with the goal of determining if the hardware of the iPhone permits the whole system to comply with international regulations regarding sound level meters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents ASYTRAIN, a new tool to teach and learn antennas, based on the use of a modular building kit and a low cost portable antenna measurement system that lets the students design and build different types of antennas and observe their characteristics while learning the insights of the subjects. This tool has a methodology guide for try-and-test project development and, makes the students be active antenna engineers instead of passive learners. This experimental learning method arises their motivation during the antenna courses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a method for the identification of different partial discharges (PDs) sources through the analysis of a collection of PD signals acquired with a PD measurement system. This method, robust and sensitive enough to cope with noisy data and external interferences, combines the characterization of each signal from the collection, with a clustering procedure, the CLARA algorithm. Several features are proposed for the characterization of the signals, being the wavelet variances, the frequency estimated with the Prony method, and the energy, the most relevant for the performance of the clustering procedure. The result of the unsupervised classification is a set of clusters each containing those signals which are more similar to each other than to those in other clusters. The analysis of the classification results permits both the identification of different PD sources and the discrimination between original PD signals, reflections, noise and external interferences. The methods and graphical tools detailed in this paper have been coded and published as a contributed package of the R environment under a GNU/GPL license.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las sondas eléctricas se emplean habitualmente en la diagnosis de plasmas. La presente tesis aborda la operación de las sondas colectoras y emisoras de Langmuir en plasmas fríos de baja densidad. El estudio se ha centrado en la determinación del potencial de plasma, Vsp, mediante el potencial flotante de una sonda emisora. Esta técnica consiste en la medida del potencial de la sonda correspondiente a la condición de corriente neta igual a cero, el cual se denomina potencial flotante, VF. Este potencial se desplaza hacia el potencial del plasma según aumenta la emisión termoiónica de la sonda, hasta que se satura cerca de Vsp. Los experimentos llevados a cabo en la pluma de plasma de un motor iónico y en un plasma de descarga de glow muestran que la corriente de electrones termoiónicos es mayor que la corriente de electrones recogidos para una sonda polarizada por debajo del potencial del plasma, resultado inconsistente con la teoría tradicionalmente aceptada. Para investigar estos resultados se ha introducido el parámetro R, definido como el cociente entre la corriente de electrones emitidos y recogidos por la sonda. Este parámetro, que está relacionado con la diferencia de potencial VF - Vsp, también es útil para la descripción de los modos de operación de la sonda emisora (débil, fuerte y más allá del fuerte). Los resultados experimentales evidencian que, al contrario de lo que indica la teoría, R es mayor que la unidad. Esta discrepancia se puede solucionar introduciendo una población efectiva de electrones. Con dicha población, el nuevo modelo para la corriente total de la sonda reproduce los datos experimentales. El origen de este grupo electrónico es todavía una cuestión abierta, pero podría estar originada por una nueva estructura de potencial cerca de la sonda cuando ésta trabaja en el régimen de emisión fuerte. Para explicar dicha estructura de potencial, se propone un modelo unidimensional compuesto por un mínimo de potencial cerca de la superficie de la sonda. El análisis numérico indica que este pozo de potencial aparece para muy altas temperaturas de la sonda, reduciendo la cantidad de electrones emitidos que alcanzan el plasma y evitando así cualquier posible perturbación de éste. Los aspectos experimentales involucrados en el método del potencial flotante también se han estudiado, incluyendo cuestiones como las diferentes técnicas de obtención del VF, el cociente señal-ruido, el acoplamiento de la señal de los equipos utilizados para la obtención de las curvas I-V o la evidencia experimental de los diferentes modos de operación de la sonda. Estas evidencias empíricas se encuentran en todos los aspectos de operación de la sonda: la recolección de electrones, el potencial flotante, la precisión en las curvas I-V y la emisión electrónica. Ésta última también se estudia en la tesis, debido a que un fenómeno de super emisión tiene lugar en el régimen de emisión fuerte. En este modo de operación, las medidas experimentales indican que las corrientes termoiónicas de electrones son mayores que aquéllas predichas por la ecuación de Richardson-Dushman clásica. Por último, la diagnosis de plasmas usando sondas eléctrica bajo presencia de granos de polvo (plasmas granulares) en plasmas fríos de baja densidad también se ha estudiado, mediante la aplicación numérica de la técnica del potencial flotante de la sonda emisora en un plasma no convencional. Los resultados apuntan a que el potencial flotante de una sonda emisora se vería afectado por altas densidades de polvo o grandes partículas. ABSTRACT Electric probes are widely employed for plasma diagnostics. This dissertation concerns the operation of collecting and emissive Langmuir probes in low density cold plasmas. The study is focused on the determination of the plasma potential, Vsp, by means of the floating potential of emissive probes. This technique consists of the measurement of the probe potential, corresponding to the zero net probe current, which is the so-called floating potential, VF . This potential displaces towards the plasma potential as the thermionic electron emission increases, until it saturates near Vsp. Experiments carried out in the plasma plume of an ion thruster and in a glow discharge plasma show the thermionic electron current of the emissive Langmuir probe is higher than the collected electron current, for a probe with a bias potential below Vsp, which is inconsistent with the traditional accepted theory. To investigate these results, a parameter R is introduced as the ratio between the emitted and the collected electron current. This parameter, which is related to the difference VF - Vsp, is also useful for the description of the operation modes of the emissive Langmuir probe (weak, strong and beyond strong). The experimental results give an inconsistency of R > 1, which is solved by a modification of the theory for emissive probes, with the introduction of an effective electron population. With this new electron group, the new model for the total probe current agrees with the experimental data. The origin of this electron group remains an open question, but it might be originated by a new potential structure near the emissive probe when it operates in the strong emission regime. A simple one-dimension model composed by a minimum of potential near the probe surface is discussed for strongly emitting emissive probes. The results indicate that this complex potential structure appears for very high probe temperatures and the potential well might reduce the emitted electrons population reaching the plasma bulk. The experimental issues involved in the floating potential method are also studied, as the different obtaining techniques of VF, the signal-to-noise ratio, the signal coupling of the I-V curve measurement system or the experimental evidence of the probe operation modes. These empirical proofs concern all the probe operation aspects: the electron collection, the floating potential, the I-V curve accuracy as well as the electron emission. This last issue is also investigated in this dissertation, because a super emission takes place in the strong emission regime. In this operation mode, the experimental results indicate that the thermionic electron currents might be higher than those predicted by the classical Richardson-Dushman equation. Finally, plasma diagnosis using electric probes in the presence of dust grains (dusty plasmas) in low density cold plasmas is also addressed. The application of the floating potential technique of the emissive probe in a non-conventional complex plasma is numerically investigated, whose results point out the floating potential of the emissive probe might be shifted for high dust density or large dust particles.