6 resultados para Measurement range
em Universidad Politécnica de Madrid
Resumo:
So far, the majority of reports on on-line measurement considered soil properties with direct spectral responses in near infrared spectroscopy (NIRS). This work reports on the results of on-line measurement of soil properties with indirect spectral responses, e.g. pH, cation exchange capacity (CEC), exchangeable calcium (Caex) and exchangeable magnesium (Mgex) in one field in Bedfordshire in the UK. The on-line sensor consisted of a subsoiler coupled with an AgroSpec mobile, fibre type, visible and near infrared (vis–NIR) spectrophotometer (tec5 Technology for Spectroscopy, Germany), with a measurement range 305–2200 nm to acquire soil spectra in diffuse reflectance mode. General calibration models for the studied soil properties were developed with a partial least squares regression (PLSR) with one-leave-out cross validation, using spectra measured under non-mobile laboratory conditions of 160 soil samples collected from different fields in four farms in Europe, namely, Czech Republic, Denmark, Netherland and UK. A group of 25 samples independent from the calibration set was used as independent validation set. Higher accuracy was obtained for laboratory scanning as compared to on-line scanning of the 25 independent samples. The prediction accuracy for the laboratory and on-line measurements was classified as excellent/very good for pH (RPD = 2.69 and 2.14 and r2 = 0.86 and 0.78, respectively), and moderately good for CEC (RPD = 1.77 and 1.61 and r2 = 0.68 and 0.62, respectively) and Mgex (RPD = 1.72 and 1.49 and r2 = 0.66 and 0.67, respectively). For Caex, very good accuracy was calculated for laboratory method (RPD = 2.19 and r2 = 0.86), as compared to the poor accuracy reported for the on-line method (RPD = 1.30 and r2 = 0.61). The ability of collecting large number of data points per field area (about 12,800 point per 21 ha) and the simultaneous analysis of several soil properties without direct spectral response in the NIR range at relatively high operational speed and appreciable accuracy, encourage the recommendation of the on-line measurement system for site specific fertilisation.
Resumo:
This paper explains the progress accomplished in the WP03 of the Terasense Project (TERAHERTZ TECHNOLOGY FOR ELECTROMAGNETIC SENSING APPLICATIONS) approved in the 2008 CONSOLIDERINGENIO program (project CSD2008-0068). The Radiation and Sensor Measurement Lab (RSMLab) is a laboratory based in the existing antenna measurement laboratories at UPM, UC3 and UNiOvi and the new capacities to extend the measurement range from the millimetre wave to the THz region. This laboratory is intended to be shared in more than one place and with more than one institution, in such a way that we could take advantage of other research financial sources and contributions from other institutions with interest in the same field of measurements. One important task will be the international links between the RSMLab and other European and international institutions dedicated to the antenna and sensor measurement in the same frequency range.
Resumo:
In recent years, the technology for measuring the diameter and height of standing trees has improved significantly. These enhancements allow estimation of the volume of standing trees using stem taper equations, which traditionally have been constructed with data from felled trees, in an accurate and economically feasible way. A nondestructive method was evaluated with data from 38 pines and was validated with data from another 38 pines, both in the Northern Iberian Range (Spain). The electronic dendrometer Criterion RD1000 (Laser Technology Inc.) and the laser hypsometer TruPulse (Laser Technology Inc.) were used due to their accuracy and interoperability. The methodology was valid (unbiased and precise) measuring from a distance similar to the height of the tree. In this distance, statistical criteria and plots based on the residuals showed no clear advantage in volume estimation with models fitted with data from destructive methods against models fitted with data from the proposed non-destructive technique. This methodology can be considered useful for individual volume estimation and for developing taper equations.
Resumo:
The verification of compliance with a design specification in manufacturing requires the use of metrological instruments to check if the magnitude associated with the design specification is or not according with tolerance range. Such instrumentation and their use during the measurement process, has associated an uncertainty of measurement whose value must be related to the value of tolerance tested. Most papers dealing jointly tolerance and measurement uncertainties are mainly focused on the establishment of a relationship uncertainty-tolerance without paying much attention to the impact from the standpoint of process cost. This paper analyzes the cost-measurement uncertainty, considering uncertainty as a productive factor in the process outcome. This is done starting from a cost-tolerance model associated with the process. By means of this model the existence of a measurement uncertainty is calculated in quantitative terms of cost and its impact on the process is analyzed.
Resumo:
In this paper a model for the measuring process of sonic anemometers (ultrasound pulse based) is presented. The differential equations that describe the travel of ultrasound pulses are solved in the general case of non-steady, non-uniform atmospheric flow field. The concepts of instantaneous line-average and travelling pulse-referenced average are established and employed to explain and calculate the differences between the measured turbulent speed (travelling pulse-referenced average) and the line-averaged one. The limit k1l=1 established by Kaimal in 1968, as the maximum value which permits the neglect of the influence of the sonic measuring process on the measurement of turbulent components is reviewed here. Three particular measurement cases are analysed: A non-steady, uniform flow speed field, a steady, non-uniform flow speed field and finally an atmospheric flow speed field. In the first case, for a harmonic time-dependent flow field, Mach number, M (flow speed to sound speed ratio) and time delay between pulses have revealed themselves to be important parameters in the behaviour of sonic anemometers, within the range of operation. The second case demonstrates how the spatial non-uniformity of the flow speed field leads to an influence of the finite transit time of the pulses (M≠0) even in the absence of non-steady behaviour of the wind speed. In the last case, a model of the influence of the sonic anemometer processes on the measurement of wind speed spectral characteristics is presented. The new solution is compared to the line-averaging models existing in the literature. Mach number and time delay significantly distort the measurement in the normal operational range. Classical line averaging solutions are recovered when Mach number and time delay between pulses go to zero in the new proposed model. The results obtained from the mathematical model have been applied to the calculation of errors in different configurations of practical interest, such as an anemometer located on a meteorological mast and the transfer function of a sensor in an atmospheric wind. The expressions obtained can be also applied to determine the quality requirements of the flow in a wind tunnel used for ultrasonic anemometer calibrations.
Resumo:
The accelerometers used for the measurement of microvibrations or microgravity applications, such as active control of space structures, attitude control, scientific payloads, or even on-Earth testing of structures at very low-excitation levels, require a dedicated calibration procedure that includes the gravitational effects. Otherwise, on-Earth calibrations can be inaccurate due to the collateral projection of the local gravity onto the sensitive axis. An on-Earth calibration technique for the 107102s amplitude range and 0-100-Hz frequency range is described. Special attention has been given to the modeling of gravitational effects on the response of the calibration device and the accelerometer itself. The sensitivity and resolution tests performed on piezoelectric accelerometers showthe accuracy andthe potential of thistechnique. Typical scale factorun certainty, which hasbeen carefully analyzed, is of the order of 2% at acceleration levels of 10sg.