19 resultados para Measurement in Bacteriology
em Universidad Politécnica de Madrid
Resumo:
Cold-drawn steel rods and wires retain significant residual stresses as a consequence of the manufacturing process. These residual stresses are known to be detrimental for the mechanical properties of the wires and their durability in aggressive environments. Steel makers are aware of the problem and have developed post-drawing processes to try and reduce the residual stresses on the wires. The present authors have studied this problem for a number of years and have performed a detailed characterization of the residual stress state inside cold-drawn rods, including both experimental and numerical techniques. High-energy synchrotron sources have been particularly useful for this research. The results have shown how residual stresses evolve as a consequence of cold-drawing and how they change with subsequent post-drawing treatments. The authors have been able to measure for the first time a complete residual strain profile along the diameter in both phases (ferrite and cementite) of a cold-drawn steel rod.
Resumo:
Irrigation management in large crop fields is a very important practice. Since the farm management costs and the crop results are directly connected with the environmental moisture, water control optimization is a critical factor for agricultural practices, as well as for the planet sustainability. Usually, the crop humidity is measured through the water stress index (WSI), using imagery acquired from satellites or airplanes. Nevertheless, these tools have a significant cost, lack from availability, and dependability from the weather. Other alternative is to recover to ground tools, such as ground vehicles and even static base stations. However, they have an outstanding impact in the farming process, since they can damage the cultivation and require more human effort. As a possible solution to these issues, a rolling ground robot have been designed and developed, enabling non-invasive measurements within crop fields. This paper addresses the spherical robot system applied to intra-crop moisture measurements. Furthermore, some experiments were carried out in an early stage corn field in order to build a geo-referenced WSI map.
Resumo:
When aqueous suspensions of gold nanorods are irradiated with a pulsing laser (808 nm), pressure waves appear even at low frequencies (pulse repetition rate of 25 kHz). We found that the pressure wave amplitude depends on the dynamics of the phenomenon. For fixed concentration and average laser current intensity, the amplitude of the pressure waves shows a trend of increasing with the pulse slope and the pulse maximum amplitude.We postulate that the detected ultrasonic pressure waves are a sort of shock waves that would be generated at the beginning of each pulse, because the pressure wave amplitude would be the result of the positive interference of all the individual shock waves.
Resumo:
During the last five years, in order to improve understanding of content related to "Coordinate Metrology", the Laboratorio de Metrología y Metrotecnia (LMM) from the Polytechnic University of Madrid offers its PhD students, as a course work, the construction of a virtual instrument. This virtual instrument simulates the imaging of a part to be measured by optical dimensional metrology instruments (microscopes, profile projectors, vision machines). The LMM provides students with images similar to those they would obtain with real instrumentation for the instrument adjustment and calibration process. Working with these images, students should determine the adjustment parameters of the virtual instrument. Once these parameters are set, the student can perform the proper calibration of the virtual instrument. Beyond this process, the instrument is already able to perform traceable measurement. In order to do that, LMM offers students some images of parts. Students should perform some measurements using those images and estimate the corresponding uncertainties.
Resumo:
This paper explains the progress accomplished in the WP03 of the Terasense Project (TERAHERTZ TECHNOLOGY FOR ELECTROMAGNETIC SENSING APPLICATIONS) approved in the 2008 CONSOLIDERINGENIO program (project CSD2008-0068). The Radiation and Sensor Measurement Lab (RSMLab) is a laboratory based in the existing antenna measurement laboratories at UPM, UC3 and UNiOvi and the new capacities to extend the measurement range from the millimetre wave to the THz region. This laboratory is intended to be shared in more than one place and with more than one institution, in such a way that we could take advantage of other research financial sources and contributions from other institutions with interest in the same field of measurements. One important task will be the international links between the RSMLab and other European and international institutions dedicated to the antenna and sensor measurement in the same frequency range.
Resumo:
In the field of dimensional metrology, the use of optical measuring machines requires the handling of a large number of measurement points, or scanning points, taken from the image of the measurand. The presence of correlation between these measurement points has a significant influence on the uncertainty of the result. The aim of this work is the development of an estimation procedure for the uncertainty of measurement in a geometrically elliptical shape, taking into account the correlation between the scanning points. These points are obtained from an image produced using a commercial flat bed scanner. The characteristic parameters of the ellipse (coordinates of the center, semi-axes and the angle of the semi-major axis with regard to the horizontal) are determined using a least squares fit and orthogonal distance regression. The uncertainty is estimated using the information from the auto-correlation function of the residuals and is propagated through the fitting algorithm according to the rules described in Evaluation of Measurement Data—Supplement 2 to the ‘Guide to the Expression of Uncertainty in Measurement’—Extension to any number of output quantities. By introducing the concept of cut-off length, it can be observed how it is possible to take into account the presence of the correlation in the estimation of uncertainty in a very simple way while avoiding underestimation.
Resumo:
Dynamic weighing systems based on load cells are commonly used to estimate crop yields in the field. There is lack of data, however, regarding the accuracy of such weighing systems mounted on harvesting machinery, especially on that used to collect high value crops such as fruits and vegetables. Certainly, dynamic weighing systems mounted on the bins of grape harvesters are affected by the displacement of the load inside the bin when moving over terrain of changing topography. In this work, the load that would be registered in a grape harvester bin by a dynamic weighing system based on the use of a load cell was inferred by using the discrete element method (DEM). DEM is a numerical technique capable of accurately describing the behaviour of granular materials under dynamic situations and it has been proven to provide successful predictions in many different scenarios. In this work, different DEM models of a grape harvester bin were developed contemplating different influencing factors. Results obtained from these models were used to infer the output given by the load cell of a real bin. The mass detected by the load cell when the bin was inclined depended strongly on the distribution of the load within the bin, but was underestimated in all scenarios. The distribution of the load was found to be dependent on the inclination of the bin caused by the topography of the terrain, but also by the history of inclination (inclination rate, presence of static periods, etc.) since the effect of the inertia of the particles (i.e., representing the grapes) was not negligible. Some recommendations are given to try to improve the accuracy of crop load measurement in the field.
Resumo:
En este trabajo, materiales de tipo alúmina/Y-TZP (ZrO2 tetragonal, estabilizada con 3 mol. % Y2O3), como sistema cerámico popular por sus mejoradas propiedades mecánicas en comparación con las cerámicas de alúmina puras, han sido estudiados en términos de propiedades mecánicas y tensiones residuales. El novedoso método de colado en cinta, consistente en el apilamiento de cintas de cerámica verde a temperatura ambiente y el uso de bajas presiones, se ha escogido para la presente investigación con el fin de poder aprovechar al máximo el futuro desarrollo de materiales laminados de alúmina-óxido de circonio. Se han determinado las propiedades de los materiales obtenidos por este nuevo método de procesamiento comparándolas con las de los materiales obtenidos por “slip casting”, con el fin de analizar si el método propuesto afecta a la microestructura y, por tanto, a las propiedades mecánicas y tensiones residuales propias de estos materiales. Para analizar la idoneidad del proceso de fabricación, utilizado para evitar la presencia de discontinuidades en las intercaras entre las láminas así como otros fenómenos que puedan interferir con las propiedades mecánicas, se estudiaron materiales cerámicos con la misma composición en cintas. Por otra parte también se analizó el efecto de la adición de óxido de circonio sobre la aparición de tensiónes residuales en cerámicas Al2O3/Y-TZP, teniendo en cuenta su notable influencia sobre las propiedades microestructurales y mecánicas de los materiales, así como el requisito de co-sinterización de capas con diferentes materiales compuestos en materiales laminados. La caracterización del material incluye la determinación de la densidad, el análisis de la microestructura, la obtención de las propiedades mecánicas (módulo de elasticidad, dureza, resistencia a la flexión y tenacidad de fractura) así como de las tensiones residuales. En combinación con otros métodos de medida tradicionales, la nanoindentación también se empleó como una técnica adicional para la medida del módulo de elasticidad y de la dureza. Por otro lado, diferentes técnicas de difracción con neutrones, tanto las basadas en longitud de onda constante (CW) como en tiempo de vuelo (TOF), han sido empleadas para la medición fiable de la deformación residual a través del grosor en muestras a granel. Las tensiones residuales fueron determinadas con elevada precisión, aplicando además métodos de análisis apropiados, como por ejemplo el refinamiento de Rietveld. Las diferentes fases en cerámicas sinterizadas, especialmente las de zirconia, se examinaron con detalle mediante el análisis de Rietveld, teniendo en cuenta el complicado polimorfismo del Óxido de Zirconio (ZrO2) así como las posibles transformaciones de fase durante el proceso de fabricación. Los efectos del contenido de Y-TZP en combinación con el nuevo método de procesamiento sobre la microestructura, el rendimiento mecánico y las tensiones residuales de los materiales estudiados (Al2O3/Y-TZP) se resumen en el presente trabajo. Finalmente, los mecanismos de endurecimiento, especialmente los relacionados con las tensiones residuales, son igualmente discutidos. In present work, Alumina/Y-TZP (tetragonal ZrO2 stabilized with 3 mol% Y2O3) materials, as an popular ceramic system with improved mechanical properties compared with the pure alumina ceramics, have been studied in terms of mechanical properties and residual stresses. The novel tape casting method, which involved the stacking of green ceramics tapes at room temperature and using low pressures, is selected for manufacturing and investigation, in order to take full advantage of the future development of alumina-zirconia laminated materials. Features of materials obtained by the new processing method are determined and compared with those of materials obtained by conventional slip casting in a plaster mold, in order to study whether the proposed method of processing affects microstructure and thereby the mechanical properties and residual stresses characteristics of materials. To analyse the adequacy of the manufacturing process used to avoid the presence of discontinuities at the interfaces between the sheets and other phenomena that interfere with the mechanical properties, ceramic materials with the same composition in tapes were investigated. Moreover, the effect of addition of zirconia on residual stress development of Al2O3/Y-TZP ceramics were taken into investigations, considering its significantly influence on the microstructure and mechanical properties of materials as well as the requirement of co-sintering of layers with different composites in laminated materials. The characterization includes density, microstructure, mechanical properties (elastic modulus, hardness, flexure strength and fracture toughness) and residual stresses. Except of the traditional measurement methods, nanoindentation technique was also used as an additional measurement of the elastic modulus and hardness. Neutron diffraction, both the constant-wavelength (CW) and time-of-flight (TOF) neutron diffraction techniques, has been used for reliable through-thickness residual strain measurement in bulk samples. Residual stresses were precisely determined combined with appropriate analysis methods, e.g. the Rietveld refinement. The phase compositions in sintered ceramics especially the ones of zirconia were accurately examined by Rietveld analysis, considering the complex polymorph of ZrO2 and the possible phase transformation during manufacturing process. Effects of Y-TZP content and the new processing method on the microstructure, mechanical performance and residual stresses were finally summarized in present studied Al2O3/Y-TZP materials. The toughening mechanisms, especially the residual stresses related toughening, were theoretically discussed.
Resumo:
In this paper a model for the measuring process of sonic anemometers (ultrasound pulse based) is presented. The differential equations that describe the travel of ultrasound pulses are solved in the general case of non-steady, non-uniform atmospheric flow field. The concepts of instantaneous line-average and travelling pulse-referenced average are established and employed to explain and calculate the differences between the measured turbulent speed (travelling pulse-referenced average) and the line-averaged one. The limit k1l=1 established by Kaimal in 1968, as the maximum value which permits the neglect of the influence of the sonic measuring process on the measurement of turbulent components is reviewed here. Three particular measurement cases are analysed: A non-steady, uniform flow speed field, a steady, non-uniform flow speed field and finally an atmospheric flow speed field. In the first case, for a harmonic time-dependent flow field, Mach number, M (flow speed to sound speed ratio) and time delay between pulses have revealed themselves to be important parameters in the behaviour of sonic anemometers, within the range of operation. The second case demonstrates how the spatial non-uniformity of the flow speed field leads to an influence of the finite transit time of the pulses (M≠0) even in the absence of non-steady behaviour of the wind speed. In the last case, a model of the influence of the sonic anemometer processes on the measurement of wind speed spectral characteristics is presented. The new solution is compared to the line-averaging models existing in the literature. Mach number and time delay significantly distort the measurement in the normal operational range. Classical line averaging solutions are recovered when Mach number and time delay between pulses go to zero in the new proposed model. The results obtained from the mathematical model have been applied to the calculation of errors in different configurations of practical interest, such as an anemometer located on a meteorological mast and the transfer function of a sensor in an atmospheric wind. The expressions obtained can be also applied to determine the quality requirements of the flow in a wind tunnel used for ultrasonic anemometer calibrations.
Resumo:
The energy and specific energy absorbed in the main cell compartments (nucleus and cytoplasm) in typical radiobiology experiments are usually estimated by calculations as they are not accessible for a direct measurement. In most of the work, the cell geometry is modelled using the combination of simple mathematical volumes. We propose a method based on high resolution confocal imaging and ion beam analysis (IBA) in order to import realistic cell nuclei geometries in Monte-Carlo simulations and thus take into account the variety of different geometries encountered in a typical cell population. Seventy-six cell nuclei have been imaged using confocal microscopy and their chemical composition has been measured using IBA. A cellular phantom was created from these data using the ImageJ image analysis software and imported in the Geant4 Monte-Carlo simulation toolkit. Total energy and specific energy distributions in the 76 cell nuclei have been calculated for two types of irradiation protocols: a 3 MeV alpha particle microbeam used for targeted irradiation and a 239Pu alpha source used for large angle random irradiation. Qualitative images of the energy deposited along the particle tracks have been produced and show good agreement with images of DNA double strand break signalling proteins obtained experimentally. The methodology presented in this paper provides microdosimetric quantities calculated from realistic cellular volumes. It is based on open-source oriented software that is publicly available.
Resumo:
Fiber optic sensors have some advantages in subjects related with electrical current and magnetic field measurement. In spite of the optical fiber utilization advantages we have to take into account undesirable effects, which are present in real non-ideal optical fibers. In telecommunication and sensor application fields the presence of inherent and induced birefringence is crucial. The presence of birefringence may cause an undesirable change in the polarization state. In order to compensate the linear birefringence a promising method has been chosen. This method employs orthogonal polarization conjugation in the back propagation direction of the light wave in the fiber. A study and a simulation of an experimental setup are realized with the advantage of a significant sensitivity improvement.
Resumo:
Fiber optic sensors have some advantages in subjects related with electrical current and magnetic field measurement. In spite of the optical fiber utilization advantages we have to take into account undesirable effects, which are present in real non-ideal optical fibers. In telecommunication and sensor application fields the presence of inherent and induced birefringence is crucial. The presence of birefringence may cause an undesirable change in the polarization state. In order to compensate the linear birefringence a promising method has been chosen. This method employs orthogonal polarization conjugation in the back propagation direction of the light wave in the fiber. A study and a simulation of an experimental setup are realized with the advantage of a significant sensitivity improvement.
Resumo:
La medida de la presión sonora es un proceso de extrema importancia para la ingeniería acústica, de aplicación en numerosas áreas de esta disciplina, como la acústica arquitectónica o el control de ruido. Sobre todo en esta última, es necesario poder efectuar medidas precisas en condiciones muy diversas. Por otra parte, la ubicuidad de los dispositivos móviles inteligentes (smartphones, tabletas, etc.), dispositivos que integran potencia de procesado, conectividad, interactividad y una interfaz intuitiva en un tamaño reducido, abre la posibilidad de su uso como sistemas de medida de calidad y de coste bajo. En este Proyecto se pretende utilizar las capacidades de entrada y salida, procesado, conectividad inalámbrica y geolocalización de los dispositivos móviles basados en iOS, en concreto el iPhone, para implementar un sistema de medidas acústicas que iguale o supere las prestaciones de los sonómetros existentes en el mercado. SonoPhone permitirá, mediante la conexión de un micrófono de medida adecuado, la realización de medidas de acuerdo a las normas técnicas en vigor, así como la posibilidad de programar, configurar y almacenar o trasmitir las medidas realizadas, que además estarán geolocalizadas con el GPS integrado en el dispositivo móvil. También se permitirá enviar los datos de la medida a un almacenamiento remoto en la nube. La aplicación tiene una estructura modular en la que un módulo de adquisición de datos lee la señal del micrófono, un back-end efectúa el procesado necesario, y otros módulos permiten la calibración del dispositivo y programar y configurar las medidas, así como su almacenamiento y transmisión en red. Una interfaz de usuario (GUI) permite visualizar las medidas y efectuar las configuraciones deseadas por el usuario, todo ello en tiempo real. Además de implementar la aplicación, se ha realizado una prueba de funcionamiento para determinar si el hardware del iPhone es adecuado para la medida de la presión acústica de acuerdo a las normas internacionales. Sound pressure measurement is an extremely important process in the field of acoustic engineering, with applications in numerous subfields, like for instance building acoustics and noise control, where it is necessary to be able to accurately measure sound pressure in very diverse (and sometimes adverse) conditions. On the other hand, the growing ubiquity of mobile devices such as smartphones or tablets, which combine processing power, connectivity, interactivity and an intuitive interface in a small size, makes it possible to use these devices as quality low-cost measurement systems. This Project aims to use the input-output capabilities of iOS-based mobile devices, in particular the iPhone, together with their processing power, wireless connectivity and geolocation features, to implement an acoustic measurement system that rivals the performance of existing devices. SonoPhone allows, with the addition of an adequate measurement microphone, to carry out measurements that comply with current technical regulations, as well as programming, configuring, storing and transmitting the results of the measurement. These measurements will be geolocated using the integrated GPS, and can be transmitted effortlessly to a remote cloud storage. The application is structured in modular fashion. A data acquisition module reads the signal from the microphone, while a back-end module carries out the necessary processing. Other modules permit the device to be calibrated, or control the configuration of the measurement and its storage or transmission. A Graphical User Interface (GUI) allows visual feedback on the measurement in progress, and provides the user with real-time control over the measurement parameters. Not only an application has been developed; a laboratory test was carried out with the goal of determining if the hardware of the iPhone permits the whole system to comply with international regulations regarding sound level meters.
Resumo:
Mealiness is a negative attribute of sensory texture, characterised by the lack of juiciness decrease in the total amount of of water content of tissues. Peach mealy textures are known as \ and leatheriness. Besides the lack of juiciness and flavour, that characterises mealy fruits, in associated with internal browning near the stone and an incapacity of ripening although there i ripe appearance. It is considered as a physiological disorder that appears in stone fruits probably < unbalanced pectolitic enzyme activity during storage. Since January 1996, a wide EC Project entitled: "Mealiness in fruits. Consumer perception and i detection" is being carried out. Within it, the Physical Properties Laboratory (ETSIA-UPM) working to develop instrumental procedures to detect mealiness in different types of fruits (s contributions by Barreiro to AgEng). The results obtained have shown to correlate well with \ measurements in apples (Barreiro et al), also we have succeeded in identifying individual mealy j the basis of instrumental measurement in peaches. The definition of these texture categories will be used in further studies as a base for new individual classification.
Resumo:
Este proyecto está dividido en dos partes, una de ellas dedicada al estudio del sistema de adquisición NetdB y su aplicación a prácticas de Acústica Arquitectónica y la otra dedicada a la evaluación de la herramienta OneNote 2010 y su aplicación al proceso enseñanza – aprendizaje. Se estructura en cinco secciones bien definidas que se comentan a continuación: La primera sección, fundamentos teóricos, se centrará en explicar los distintos parámetros medidos y su relación con la acústica. Para ello se definirán los conceptos teóricos básicos que ayudarán al seguimiento del proyecto en su totalidad. La segunda sección está dedicada al sistema de adquisición NetdB, y en ella se explican sus características, el conexionado del equipo y la configuración del mismo con el software dBBati. En la tercera sección se describen las medidas realizadas con el sistema de adquisición NetdB, basadas en la normativa nacional e internacional vigente. Estas medidas son: - Medición del tiempo de reverberación en recintos ordinarios, según la Norma UNE-EN ISO 3382-2. - Medición del coeficiente de absorción sonora en cámara reverberante, según la Norma UNE-EN ISO 354. - Medición “in situ” del aislamiento a ruido aéreo, según las normas UNE-EN ISO 140-4 y UNE-EN ISO 717-1. En cada una de las medidas se describe el objetivo, los equipos utilizados, la conexión entre los distintos equipos, el ensayo realizado según la norma correspondiente, los cálculos y resultados obtenidos y las conclusiones finales de la medida. En la cuarta sección se describe la herramienta OneNote 2010, detallándose su estructura, configuración y la evaluación de su aplicación al proceso enseñanza – aprendizaje. Por último, se darán unas conclusiones finales, en las que se recapitularán los resultados de las valoraciones obtenidos durante la realización del proyecto. ABSTRACT. This project is divided into two parts, one of them dealing with the study of NetdB acquisition system and its application on Architectural Acoustics practices and the other dedicated to the evaluation of the OneNote 2010 tool and its application on the teaching-learning process. The structure of the project consists of five clearly defined sections as stated hereunder: 1. Theoretical fundamentals, based on the explanation of the different parameters subject to measurement and their relation to acoustics. To this end, basic theoretical concepts will be clearly defined, which will help the follow-up of the project as a whole. 2. NetdB acquisition system: whereby features will be clearly defined, as well as the equipment connection and its configuration within the dBBati software. 3. Description of the measures carried out on the NetdB acquisition system under current regulations both national and international, being those measures as follows: - Reverberation Time measurement in ordinary premises, according to the UNE-EN ISO 3382-2 standard. - Sound absorption ratio measurement in reverberating chamber, according to the UNE-EN ISO 354 standard. - “In situ” sound proofing air traffic, according to UNE-EN ISO 140-4 and UNE-EN ISO 717-1 standards. Each of the measures stated above comprises the description of the following issues: its aim, the equipment in use, the connection among different equipment, the test carried out under the corresponding standard, the calculations and results obtained and finally the conclusions reached at. 4. OneNote 2010 tool: full description detailing its structure, configuration as well as the evaluation of its application on the teaching-learning process. Finally, the report will give the final conclusions by means of recapitulating the results of the different assessments obtained along the process.