6 resultados para Measure in the experimental work

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluation of three solar and daylighting control systems based on Calumen II, Ecotect and Radiance simulation programs to obtain an energy efficient and healthy interior in the experimental building prototype SDE10

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper shows the results of the new steps that have been done in the development of the tidal energy converter GESMEY. These are the design, construction and trials into the sea of a 1/10 scale prototype and also the construction with the same scale of the buoy BOSCEM, that anchors the device and lets it in the correct work position and depth, along the two directions of the flow that the daily tidal cycle have. Inside the paper is described the objectives and the methodology of the experimental trials that were ca rry out the last summer with the scale prototype. GESMEY is a new type of tidal energy converter (TEC) that has the capability to exploit currents in waters over forty meters by itself and it gets only using its internal ballast system the necessary equilibrium between hy drostatics and hydrodynamics forces to make the emersion and the immersion procedures without any other help. Finally the paper shows the description of the results obtained over the performance of the devices along the immersion, emersion and floating transport manoeuvres and afterwards the results, that were obtained along the generation power tests that were carried out, are shown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

NADPH: protochlorophyllide oxido reductase (POR) A is a key enzyme of chlorophyll biosynthesis in angiosperms. It is nucleus-encoded, synthesized as a larger precursor in the cytosol and imported into the plastids in a substrate-dependent manner. Plastid envelope membrane proteins, called protochlorophyllide dependent translocon proteins, Ptcs, have been identified that interact with pPORA during import. Amongthem are a 16-kDa ortholog of the previously characterized outer envelope protein Oep16 (named Ptc16) and a33-kDa protein (Ptc33) related to the GTP-binding proteins Toc33 and Toc34 of Arabidopsis. In the present work, we studied the interactions and roles of Ptc16 and Ptc33 during pPORA import. Radio labeled Ptc16/Oep16 was synthesized from a corresponding cDNA and imported into isolated Arabidopsis plastids. Crosslinking experiments revealed that import of35S-Oep16/Ptc16 is stimulated by GTP.35S-Oep16/Ptc16forms larger complexes with Toc33 but not Toc34. Plastids of the ppi1 mutant of Arabidopsis lacking Toc33, were unable to import pPORA in darkness but imported the small subunit precursor of ribulose-1,5-bisphosphate carboxylase/oxygenase (pSSU), precursor ferredoxin (pFd) as well as pPORB which is a close relative of pPORA. In white light, partial suppressions of pSSU, pFd and pPORB import were observed. Our results unveil a hitherto unrecognized role of Toc33 in pPORA import and suggest photo oxidative membrane damage, induced by excess Pchlide accumulating in ppi1 chloroplasts because of the lack of pPORA import, to be the cause of the general drop of protein import.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Theoretical models for the thermal response of vertical geothermal boreholes often assume that the characteristic time of variation of the heat injection rate is much larger than the characteristic diffusion time across the borehole. In this case, heat transfer inside the borehole and in its immediate surroundings is quasi-steady in the first approximation, while unsteady effects enter only in the far field. Previous studies have exploited this disparity of time scales, incorporating approximate matching conditions to couple the near-borehole region with the outer unsteady temperatura field. In the present work matched asymptotic expansion techniques are used to analyze the heat transfer problem, delivering a rigorous derivation of the true matching condition between the two regions and of the correct definition of the network of thermal resistances that represents the quasi-steady solution near the borehole. Additionally, an apparent temperature due to the unsteady far field is identified that needs to be taken into account by the near-borehole region for the correct computation of the heat injection rate. This temperature differs from the usual mean borehole temperature employed in the literatura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Residual stresses developed during wire drawing influence the mechanical behavior and durability of steel wires used for prestressed concrete structures, particularly the shape of the stress–strain curve, stress relaxation losses, fatigue life, and environmental cracking susceptibility. The availability of general purpose finite element analysis tools and powerful diffraction techniques (X-rays and neutrons) has made it possible to predict and measure accurately residual stress fields in cold-drawn steel wires. Work carried out in this field in the past decade, shows the prospects and limitations of residual stress measurement, how the stress relaxation losses and environmentally-assisted cracking are correlated with the profile of residual stresses and how the performance of steel wires can be improved by modifying such a stress profile

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12°C-36°C and a maximum horizontal radiation of 1020 W/m2. Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 °C lower on the facade, while the bare wall temperature was 15 °C higher. The living wall module temperature was 1.6 °C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature.