11 resultados para Joachimstalsches Gymnasium
em Universidad Politécnica de Madrid
Resumo:
Leonardo da Vinci Gymnasium [Proyecto]
Resumo:
Proyecto de concurso para el gimnasio de la Escuela Técnica Superior de Arquitectura, Madrid
Resumo:
The dynamic floor loads induced by crowds in gymnasium or stadium structures are commonly modelled by superposition of the individual contributions using reduction factors for the different Fourier coefficients. These Fourier coefficients and the reduction factors are calculated using full scale measurements. Generally the testing is performed on platforms or structures that can be considered rigid, such that the natural frequencies are higher than the frequencies of the spectator movement. In this paper we shall present the testing done on a structure that used to be a gymnasium as well as the procedure used to identify its dynamic properties and a first evaluation of the socalled “group effect”.
Resumo:
This work explores the automatic recognition of physical activity intensity patterns from multi-axial accelerometry and heart rate signals. Data collection was carried out in free-living conditions and in three controlled gymnasium circuits, for a total amount of 179.80 h of data divided into: sedentary situations (65.5%), light-to-moderate activity (17.6%) and vigorous exercise (16.9%). The proposed machine learning algorithms comprise the following steps: time-domain feature definition, standardization and PCA projection, unsupervised clustering (by k-means and GMM) and a HMM to account for long-term temporal trends. Performance was evaluated by 30 runs of a 10-fold cross-validation. Both k-means and GMM-based approaches yielded high overall accuracy (86.97% and 85.03%, respectively) and, given the imbalance of the dataset, meritorious F-measures (up to 77.88%) for non-sedentary cases. Classification errors tended to be concentrated around transients, what constrains their practical impact. Hence, we consider our proposal to be suitable for 24 h-based monitoring of physical activity in ambulatory scenarios and a first step towards intensity-specific energy expenditure estimators
Resumo:
The commercial centre VIALIA and the new railway station of the AVE (high speed train) in Malaga was inaugurated in November 2006, just on the place of the former railway station. The new railway station with an investment of 134,7 million Euros occupies a surface of 51.377 m2, five times the surface of the former station. The enclosure is the biggest intermodal and commercial centre of Spain which comprises a parking of 21.000 m2 for 1300 parking places, one commercial area and a hotel with a total extension constructed of approximately 100.000 m2. The spaces of leisure contain cinemas, shops, restaurants, bowling, gymnasium, swimming pool and zones of passenger's traffic.
Resumo:
The commercial centre VIALIA and the new railway station of the AVE (high speed train) in Malaga was inaugurated in November 2006, just on the place of the former railway station. The new railway station with an investment of 134,7 million Euros occupies a surface of 51.377 m2, five times the surface of the former station. The enclosure is the biggest intermodal and commercial centre of Spain which comprises a parking of 21.000 m2 for 1300 parking places, one commercial area and a hotel with a total extension constructed of approximately 100.000 m2. The spaces of leisure contain cinemas, shops, restaurants, bowling, gymnasium, swimming pool and zones of passenger's traffic.
Resumo:
Applications based on Wireless Sensor Networks for Internet of Things scenarios are on the rise. The multiple possibilities they offer have spread towards previously hard to imagine fields, like e-health or human physiological monitoring. An application has been developed for its usage in scenarios where data collection is applied to smart spaces, aiming at its usage in fire fighting and sports. This application has been tested in a gymnasium with real, non-simulated nodes and devices. A Graphic User Interface has been implemented to suggest a series of exercises to improve a sportsman/woman s condition, depending on the context and their profile. This system can be adapted to a wide variety of e-health applications with minimum changes, and the user will interact using different devices, like smart phones, smart watches and/or tablets.
Resumo:
Crowd induced dynamic loading in large structures, such as gymnasiums or stadium, is usually modelled as a series of harmonic loads which are defined in terms of their Fourier coefficients. Different values of these coefficients that were obtained from full scale measurements can be found in codes. Recently, an alternative has been proposed, based on random generation of load time histories that take into account phase lag among individuals inside the crowd. This paper presents the testing done on a structure designed to be a gymnasium. Two series of dynamic test were performed on the gym slab. For the first test an electrodynamic shaker was placed at several locations and during the second one people located inside a marked area bounced and jumped guided by different metronome rates. A finite element model (FEM) is presented and a comparison of numerically predicted and experimentally observed vibration modes and frequencies has been used to assess its validity. The second group of measurements will be compared with predictions made using the FEM model and three alternatives for crowd induced load modelling.
Resumo:
Crowd induced dynamic loading in large structures, such as gymnasiums or stadiums, is usually modelled as a series of harmonic loads which are defined in terms of their Fourier coefficients. Different values of these Fourier coefficients that were obtained from full scale measurements can be found in codes. Recently, an alternative has been proposed, based on random generation of load time histories that take into account phase lags among individuals inside the crowd. Generally the testing is performed on platforms or structures that can be considered rigid because their natural frequencies are higher than the excitation frequencies associated with crowd loading. In this paper we shall present the testing done on a structure designed to be a gymnasium, which has natural frequencies within that range. In this test the gym slab was instrumented with acceleration sensors and different people jumped on a force plate installed on the floor. Test results have been compared with predictions based on the two abovementioned load modelling alternatives and a new methodology for modelling jumping loads has been proposed in order to reduce the difference between experimental and numerical results at high frequency range.
Resumo:
The interest for modelling of human actions acting on structures has been recurrent since the first accidents on suspension bridges in the nineteenth century like Broughton (1831) in the U.K. or Angers (1850) in France. Stadiums, gymnasiums are other type of structure where the human induced vibration is very important. In these structures appear particular phenomenon like the interaction person-structure (lock-in), the person-person synchronization, and the influence of the mass and damping of the people in the structure behaviour. This work focuses on the latter topic. The dynamic characteristic of a structure can be changed due to the presence of people on it. In order to evaluate these property modifications several testing have been carried out on a structure designed to be a gymnasium. For the test an electro-dynamic shaker was installed in a fixed point of the gym slab and different groups of people were located around the shaker. In each test the number of people was changed and also their posture (standing and sitting). Test data were analyzed and processed to verify modifications in the structure behaviour.
Resumo:
In this paper we present the tests on a structure designed to be a gymnasium, which has natural frequencies within that range. In these tests the gym slab was instrumented with acceleration sensors and different people jumped on a force plate installed on the floor. The test results have been compared with predictions based on the two existing load modelling alternatives (Sim and SCI Guide) and two new methodologies for modelling jumping loads has been proposed. The results of the force plate trials were analysed in an attempt to better characterize the profile of the jump force and determine how best to approximate it. In the first proposed methodology the study is carried out in the frequency domain using an average power spectral density of the jumps. In the second proposed methodology, the jump force is decomposed into the summation of one peak with a large period and a number of peaks with smaller periods. Utilizing a similar model to that of the Sim model, the approximation will still be comprised of the summation of two quadratic cosine functions.