4 resultados para Intensity Difference Fluctuations
em Universidad Politécnica de Madrid
Resumo:
The problem of determination of the turbulence onset in natural convection on heated inclined plates in an air environment has been experimentally revisited. The transition has been detected by using hot wire velocity measurements. The onset of turbulence has been considered to take place where velocity fluctuations (measured through turbulence intensity) start to grow. Experiments have shown that the onset depends not only on the Grashof number defined in terms of the temperature difference between the heated plate and the surrounding air. A correlation between dimensionless Grashof and Reynolds numbers has been obtained, fitting quite well the experimental data.
Resumo:
We propose a new method for ranking alternatives in multicriteria decision-making problems when there is imprecision concerning the alternative performances, component utility functions and weights. We assume decision maker?s preferences are represented by an additive multiattribute utility function, in which weights can be modeled by independent normal variables, fuzzy numbers, value intervals or by an ordinal relation. The approaches are based on dominance measures or exploring the weight space in order to describe which ratings would make each alternative the preferred one. On the one hand, the approaches based on dominance measures compute the minimum utility difference among pairs of alternatives. Then, they compute a measure by which to rank the alternatives. On the other hand, the approaches based on exploring the weight space compute confidence factors describing the reliability of the analysis. These methods are compared using Monte Carlo simulation.
Resumo:
Cyclic fluctuations of the atmospheric temperature on the dam site, of the water temperature in the reservoir and of the intensity of solar radiation on the faces of the dam cause significant stresses in the body of concrete dams. These stresses can be evaluated first by introducing in analysis models a linear temperature distribution statically equivalent to the real temperature distribution in the dam; the stress valúes obtained from this first step must be complemented (especially in the área of dam faces) with the stress valúes resuiting from the difference between the real temperature law and the linear law at each node. In the case of arch gravity dams, and because of their characteristics of arch dam featuring a thick section, both types of temperature-induced stresses are of similar importance. Thermal stress valúes are directly linked to a series of factors: atmospheric and water temperature and intensity of solar radiation at dam site, site latitude, azimuth of the dam, as well as geometrical characteristics of the dam and thermal properties of concrete. This thesis first presents a complete study of the physical phenomenon of heat exchange between the environment and the dam itself, and establishes the participation scheme of all parameters involved in the problem considered. A detailed documental review of available methods and techniques is then carried out both for the estimation of environmental thermal loads and for the evaluation of the stresses induced by these loads. Variation ranges are also established for the main parameters. The definition of the geometrical parameters of the dam is provided based on the description of a wide set of arch gravity dams built in Spain and abroad. As a practical reference of the parameters defining the thermal action of the environment, a set of zones, in which thermal parameters reach homogeneous valúes, was established for Spain. The mean valué and variation range of atmospheric temperature were then determined for each zone, based on a series of historical valúes. Summer and winter temperature increases caused by solar radiation were also defined for each zone. Since the hypothesis of thermal stratification in the reservoir has been considered, máximum and mínimum temperature valúes reached at the bottom of the reservoir were determined for each climatic zone, as well as the law of temperature variation in function of depth. Various dam-and-foundation configurations were analysed by means of finite element 3D models, in which the dam and foundation were each submitted to different load combinations. The seasonal thermal behaviour of sections of variable thickness was analysed through the application of numerical techniques to one-dimensional models. Contrasting the results of both analyses led to conclusions on the influence of environmental thermal action on the stress conditions of the structure. Las oscilaciones periódicas de la temperatura ambiente en el emplazamiento y de la temperatura del agua en el embalse, así como de la incidencia de la radiación solar sobre los paramentos de la presa, son causa de tensiones importantes en el cuerpo de las presas de hormigón. Estas tensiones pueden ser evaluadas en primer lugar introduciendo en los modelos tridimensionales de análisis, distribuciones lineales de temperatura estáticamente equivalentes a las correspondientes distribuciones reales en el cuerpo de la presa; las tensiones así obtenidas han de complementarse (sobre todo en las cercanías de los paramentos) con tensiones cuyo origen está en la temperatura diferencia entre la ley real y la lineal en cada punto. En el caso de las presas arco-gravedad y en razón de su doble característica de presas arco y de sección gruesa, ambas componentes de la tensión inducida por la temperatura son de magnitud similar. Los valores de estas tensiones de origen térmico están directamente relacionados con la temperatura del emplazamiento y del embalse, con la intensidad de la insolación, con la latitud y el azimut de la presa, con las características geométricas de la estructura y con las propiedades térmicas del hormigón. En esta tesis se realiza, en primer lugar, un estudio completo del fenómeno físico del intercambio de calor entre el medio ambiente y el cuerpo de la presa, estableciendo el mecanismo de participación de todos los parámetros que configuran el problema. En segundo lugar se realiza a cabo una revisión documental detallada de los métodos y técnicas utilizables tanto en la estimación de las cargas térmicas ambientales como en la evaluación de las tensiones inducidas por dichas cargas. En tercer lugar se establecen rangos de variación para los principales parámetros que configuran el problema. Los parámetros geométricos de la presa se definen a partir de la descripción de un amplio conjunto de presas arco-gravedad tanto españolas como del resto del mundo. Como referencia práctica de los parámetros que definen la acción térmica ambiental se establecen en España un conjunto de zonas caracterizadas por que, en cada una de ellas, los parámetros térmicos alcanzan valores homogéneos. Así, y en base a series de valores históricos, se establecen la media y la amplitud de la variación anual de la temperatura ambiental en cada una de las zonas. Igualmente, se han definido para cada zona los incrementos de temperatura que, en invierno y en verano, produce la insolación. En relación con el agua del embalse y en la hipótesis de estratificación térmica de este, se han definido los valores, aplicables en cada una de las zonas, de las temperaturas máxima y mínima en el fondo así como la ley de variación de la temperatura con la profundidad. Utilizando modelos tridimensionales de elementos finitos se analizan diferentes configuraciones de la presa y la cimentación sometidas, cada una de ellas, a diferentes combinaciones de carga. Aplicando técnicas numéricas a modelos unidimensionales se analiza el comportamiento térmico temporal de secciones de espesor variable. Considerando conjuntamente los resultados de los análisis anteriores se obtienen conclusiones parametrizadas de detalle sobre la influencia que tiene en el estado tensional de la estructura la consideración de la acción térmica ambiental.
Resumo:
A time division multiplexing (TDM) array for passive multiplexing of identical fibre, optic intensity sensors has been demonstrated. Microbending loss sensors are introduced in fibre optic rings and pressure information is directly detected, demultiplexed and demodulated from the relative amplitude of the first two pulses produced on each ring. Several dynamic ranges from 6 dB to 14 dB are shown. A comparison between both fibre optic ring and Mach-Zehnder structure impulse responses is carried out and the consequences derived from second- and higher-order recirculating ring pulses are also evaluated. This technique can be applied to those TDM intensity sensing schemes which require low cost, high number of identical sensors, and suffer high element loss and undersirable intensity fluctuations at low frequencies.