26 resultados para Infrared termography

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we show room temperature operation of a quantum well infrared photodetector (QWIP) using lateral conduction through ohmic contacts deposited at both sides of two n-doped quantum wells. To reduce the dark current due to direct conduction in the wells, we apply an electric field between the quantum wells and two pinch-off Schottky gates, in a fashion similar to a field effect device. Since the normal incidence absorption is strongly reduced in intersubband transitions in quantum wells, we first analyze the response of a detector based on quantum dots (QD). This QD device shows photocurrent signal up to 150 K when it is processed in conventional vertical detector. However, it is possible to observe room temperature signal when it is processed in a lateral structure. Finally, the room temperature photoresponse of the QWIP is demonstrated, and compared with theory. An excellent agreement between the estimated and measured characteristics of the device is found

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of high efficiency laser diodes (LD) and light emitting diodes (LED) covering the 1.0 to 1.55 μm region of the spectra using GaAs heteroepitaxy has been long pursued. Due to the lack of materials that can be grown lattice-macthed to GaAs with bandgaps in the 1.0 to 1.55 μm region, quantum wells (QW) or quantum dots (QD) need be used. The most successful approach with QWs has been to use InGaAs, but one needs to add another element, such as N, to be able to reach 1.3/1.5μm. Even though LDs have been successfully demonstrated with the QW approach, using N leads to problems with compositional homogeneity across the wafer, and limited efficiency due to strong non-radiative recombination. The alternative approach of using InAs QDs is an attractive option, but once again, to reach the longest wavelengths one needs very large QDs and control over the size distribution and band alignment. In this work we demonstrate InAs/GaAsSb QDLEDs with high efficiencies, emitting from 1.1 to 1.52 μm, and we analyze the band alignment and carrier loss mechanisms that result from the presence of Sb in the capping layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum dot infrared photodetectors (QDIPs) are very attractive for many applications such as infrared imaging, remote sensing and gas sensing, thanks to its promising features such as high temperature operation, normal incidence response and low dark current [1]. However, the key issue is to obtain a high-quality active region which requires an optimization of the nanostructure. By using GaAsSb capping layer, InAs QDs have improved their optical emission in the range between 1.15 and 1.3 m (at Sb composition of 14 %), due to a reduction of a compressive strain in QD and an increment of a QD height [2]. In this work, we have demonstrated strong and narrow intraband photoresponses at ~ 5 m from GaAsSb-capped InAs/GaAs QDIPs under normal light-incidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared thermography IR is a technique, which allows us to get rapidly and non-invasive thermal images from objects or human beings. (Barnes, 1967). In Medicine, its usefulness as diagnosis tool was accepted decades ago (BenEliyahu, 1990), but other techniques with a higher efficiency -such as magnetic resonance or x-rays- ousted it. Nevertheless, the technological improvements on thermographic cameras and new studies on sport injuries are reinforcing new applications (Ring, 2006)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal response of skin temperature (Tsk) has been studied during exercise and immediately after (Merla, 2010). However, more studies about the influence of exercise on Tsk through the time are required to understand the impact of physical activity on thermoregulatory system and metabolism

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La termografía infrarroja (TI) es una técnica no invasiva y de bajo coste que permite, con el simple acto de tomar una fotografía, el registro sin contacto de la energía que irradia el cuerpo humano (Akimov & Son’kin, 2011, Merla et al., 2005, Ng et al., 2009, Costello et al., 2012, Hildebrandt et al., 2010). Esta técnica comenzó a utilizarse en el ámbito médico en los años 60, pero debido a los malos resultados como herramienta diagnóstica y la falta de protocolos estandarizados (Head & Elliot, 2002), ésta se dejó de utilizar en detrimento de otras técnicas más precisas a nivel diagnóstico. No obstante, las mejoras tecnológicas de la TI en los últimos años han hecho posible un resurgimiento de la misma (Jiang et al., 2005, Vainer et al., 2005, Cheng et al., 2009, Spalding et al., 2011, Skala et al., 2012), abriendo el camino a nuevas aplicaciones no sólo centradas en el uso diagnóstico. Entre las nuevas aplicaciones, destacamos las que se desarrollan en el ámbito de la actividad física y el deporte, donde recientemente se ha demostrado que los nuevos avances con imágenes de alta resolución pueden proporcionar información muy interesante sobre el complejo sistema de termorregulación humana (Hildebrandt et al., 2010). Entre las nuevas aplicaciones destacan: la cuantificación de la asimilación de la carga de trabajo físico (Čoh & Širok, 2007), la valoración de la condición física (Chudecka et al., 2010, 2012, Akimov et al., 2009, 2011, Merla et al., 2010), la prevención y seguimiento de lesiones (Hildebrandt et al., 2010, 2012, Badža et al., 2012, Gómez Carmona, 2012) e incluso la detección de agujetas (Al-Nakhli et al., 2012). Bajo estas circunstancias, se acusa cada vez más la necesidad de ampliar el conocimiento sobre los factores que influyen en la aplicación de la TI en los seres humanos, así como la descripción de la respuesta de la temperatura de la piel (TP) en condiciones normales, y bajo la influencia de los diferentes tipos de ejercicio. Por consiguiente, este estudio presenta en una primera parte una revisión bibliográfica sobre los factores que afectan al uso de la TI en los seres humanos y una propuesta de clasificación de los mismos. Hemos analizado la fiabilidad del software Termotracker, así como su reproducibilidad de la temperatura de la piel en sujetos jóvenes, sanos y con normopeso. Finalmente, se analizó la respuesta térmica de la piel antes de un entrenamiento de resistencia, velocidad y fuerza, inmediatamente después y durante un período de recuperación de 8 horas. En cuanto a la revisión bibliográfica, hemos propuesto una clasificación para organizar los factores en tres grupos principales: los factores ambientales, individuales y técnicos. El análisis y descripción de estas influencias deben representar la base de nuevas investigaciones con el fin de utilizar la TI en las mejores condiciones. En cuanto a la reproducibilidad, los resultados mostraron valores excelentes para imágenes consecutivas, aunque la reproducibilidad de la TP disminuyó ligeramente con imágenes separadas por 24 horas, sobre todo en las zonas con valores más fríos (es decir, zonas distales y articulaciones). Las asimetrías térmicas (que normalmente se utilizan para seguir la evolución de zonas sobrecargadas o lesionadas) también mostraron excelentes resultados pero, en este caso, con mejores valores para las articulaciones y el zonas centrales (es decir, rodillas, tobillos, dorsales y pectorales) que las Zonas de Interés (ZDI) con valores medios más calientes (como los muslos e isquiotibiales). Los resultados de fiabilidad del software Termotracker fueron excelentes en todas las condiciones y parámetros. En el caso del estudio sobre los efectos de los entrenamientos de la velocidad resistencia y fuerza en la TP, los resultados muestran respuestas específicas según el tipo de entrenamiento, zona de interés, el momento de la evaluación y la función de las zonas analizadas. Los resultados mostraron que la mayoría de las ZDI musculares se mantuvieron significativamente más calientes 8 horas después del entrenamiento, lo que indica que el efecto del ejercicio sobre la TP perdura por lo menos 8 horas en la mayoría de zonas analizadas. La TI podría ser útil para cuantificar la asimilación y recuperación física después de una carga física de trabajo. Estos resultados podrían ser muy útiles para entender mejor el complejo sistema de termorregulación humano, y por lo tanto, para utilizar la TI de una manera más objetiva, precisa y profesional con visos a mejorar las nuevas aplicaciones termográficas en el sector de la actividad física y el deporte Infrared Thermography (IRT) is a safe, non-invasive and low-cost technique that allows the rapid and non-contact recording of the irradiated energy released from the body (Akimov & Son’kin, 2011; Merla et al., 2005; Ng et al., 2009; Costello et al., 2012; Hildebrandt et al., 2010). It has been used since the early 1960’s, but due to poor results as diagnostic tool and a lack of methodological standards and quality assurance (Head et al., 2002), it was rejected from the medical field. Nevertheless, the technological improvements of IRT in the last years have made possible a resurgence of this technique (Jiang et al., 2005; Vainer et al., 2005; Cheng et al., 2009; Spalding et al., 2011; Skala et al., 2012), paving the way to new applications not only focused on the diagnose usages. Among the new applications, we highlighted those in physical activity and sport fields, where it has been recently proven that a high resolution thermal images can provide us with interesting information about the complex thermoregulation system of the body (Hildebrandt et al., 2010), information than can be used as: training workload quantification (Čoh & Širok, 2007), fitness and performance conditions (Chudecka et al., 2010, 2012; Akimov et al., 2009, 2011; Merla et al., 2010; Arfaoui et al., 2012), prevention and monitoring of injuries (Hildebrandt et al., 2010, 2012; Badža et al., 2012, Gómez Carmona, 2012) and even detection of Delayed Onset Muscle Soreness – DOMS- (Al-Nakhli et al., 2012). Under this context, there is a relevant necessity to broaden the knowledge about factors influencing the application of IRT on humans, and to better explore and describe the thermal response of Skin Temperature (Tsk) in normal conditions, and under the influence of different types of exercise. Consequently, this study presents a literature review about factors affecting the application of IRT on human beings and a classification proposal about them. We analysed the reliability of the software Termotracker®, and also its reproducibility of Tsk on young, healthy and normal weight subjects. Finally, we examined the Tsk thermal response before an endurance, speed and strength training, immediately after and during an 8-hour recovery period. Concerning the literature review, we proposed a classification to organise the factors into three main groups: environmental, individual and technical factors. Thus, better exploring and describing these influence factors should represent the basis of further investigations in order to use IRT in the best and optimal conditions to improve its accuracy and results. Regarding the reproducibility results, the outcomes showed excellent values for consecutive images, but the reproducibility of Tsk slightly decreased with time, above all in the colder Regions of Interest (ROI) (i.e. distal and joint areas). The side-to-side differences (ΔT) (normally used to follow the evolution of some injured or overloaded ROI) also showed highly accurate results, but in this case with better values for joints and central ROI (i.e. Knee, Ankles, Dorsal and Pectoral) than the hottest muscle ROI (as Thigh or Hamstrings). The reliability results of the IRT software Termotracker® were excellent in all conditions and parameters. In the part of the study about the effects on Tsk of aerobic, speed and strength training, the results of Tsk demonstrated specific responses depending on the type of training, ROI, moment of the assessment and the function of the considered ROI. The results showed that most of muscular ROI maintained warmer significant Tsk 8 hours after the training, indicating that the effect of exercise on Tsk last at least 8 hours in most of ROI, as well as IRT could help to quantify the recovery status of the athlete as workload assimilation indicator. Those results could be very useful to better understand the complex skin thermoregulation behaviour, and therefore, to use IRT in a more objective, accurate and professional way to improve the new IRT applications for the physical activity and sport sector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

So far, no experimental data of the infrared and Raman spectra of 13C isotopologue of dimethyl ether are available. With the aim of providing some clues of its low-lying vibrational bands and with the hope of contributing in a next spectral analysis, a number of vibrational transition frequencies below 300 cm−1 of the infrared spectrum and around 400 cm−1 of the Raman spectrum have been predicted and their assignments were proposed. Calculations were carried out through an ab initio three dimensional potential energy surface based on a previously reported one for the most abundant dimethyl ether isotopologue (M. Villa et al., J. Phys. Chem. A 115 (2011) 13573). The potential function was vibrationally corrected and computed with a highly correlated CCSD(T) method involving the COC bending angle and the two large amplitude CH3 internal rotation degrees of freedom. Also, the Hamiltonian parameters could represent a support for the spectral characterization of this species. Although the computed vibrational term values are expected to be very accurate, an empirical adjustment of the Hamiltonian has been performed with the purpose of anticipating some workable corrections to any possible divergence of the vibrational frequencies. Also, the symmetry breaking derived from the isotopic substitution of 13C in the dimethyl ether was taken into account when the symmetrization procedure was applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From a vibrationally corrected 3D potential energy surface determined with highly correlated ab initio calculations (CCSD(T)), the lowest vibrational energies of two dimethyl-ether isotopologues, 12CH3–16O–12CD3 (DME-d3) and 12CD3–16O–12CD3 (DME-d6), are computed variationally. The levels that can be populated at very low temperatures correspond to the COC-bending and the two methyl torsional modes. Molecular symmetry groups are used for the classification of levels and torsional splittings. DME-d6 belongs to the G36 group, as the most abundant isotopologue 12CH3–16O–12CH3 (DME-h6), while DME-d3 is a G18 species. Previous assignments of experimental Raman and far-infrared spectra are discussed from an effective Hamiltonian obtained after refining the ab initio parameters. Because a good agreement between calculated and experimental transition frequencies is reached, new assignments are proposed for various combination bands corresponding to the two deuterated isotopologues and for the 020 → 030 transition of DME-d6. Vibrationally corrected potential energy barriers, structural parameters, and anharmonic spectroscopic parameters are provided. For the 3N – 9 neglected vibrational modes, harmonic and anharmonic fundamental frequencies are obtained using second-order perturbation theory by means of CCSD and MP2 force fields. Fermi resonances between the COC-bending and the torsional modes modify DME-d3 intensities and the band positions of the torsional overtones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the potential of visible and near infrared spectroscopy (VIS+NIRS) combined with multivariate analysis for identifying the geographical origin of cork. The study was carried out on cork planks and natural cork stoppers from the most representative cork-producing areas in the world. Two training sets of international and national cork planks were studied. The first set comprised a total of 479 samples from Morocco, Portugal, and Spain, while the second set comprised a total of 179 samples from the Spanish regions of Andalusia, Catalonia, and Extremadura. A training set of 90 cork stoppers from Andalusia and Catalonia was also studied. Original spectroscopic data were obtained for the transverse sections of the cork planks and for the body and top of the cork stoppers by means of a 6500 Foss-NIRSystems SY II spectrophotometer using a fiber optic probe. Remote reflectance was employed in the wavelength range of 400 to 2500 nm. After analyzing the spectroscopic data, discriminant models were obtained by means of partial least square (PLS) with 70% of the samples. The best models were then validated using 30% of the remaining samples. At least 98% of the international cork plank samples and 95% of the national samples were correctly classified in the calibration and validation stage. The best model for the cork stoppers was obtained for the top of the stoppers, with at least 90% of the samples being correctly classified. The results demonstrate the potential of VIS + NIRS technology as a rapid and accurate method for predicting the geographical origin of cork plank and stoppers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

So far, the majority of reports on on-line measurement considered soil properties with direct spectral responses in near infrared spectroscopy (NIRS). This work reports on the results of on-line measurement of soil properties with indirect spectral responses, e.g. pH, cation exchange capacity (CEC), exchangeable calcium (Caex) and exchangeable magnesium (Mgex) in one field in Bedfordshire in the UK. The on-line sensor consisted of a subsoiler coupled with an AgroSpec mobile, fibre type, visible and near infrared (vis–NIR) spectrophotometer (tec5 Technology for Spectroscopy, Germany), with a measurement range 305–2200 nm to acquire soil spectra in diffuse reflectance mode. General calibration models for the studied soil properties were developed with a partial least squares regression (PLSR) with one-leave-out cross validation, using spectra measured under non-mobile laboratory conditions of 160 soil samples collected from different fields in four farms in Europe, namely, Czech Republic, Denmark, Netherland and UK. A group of 25 samples independent from the calibration set was used as independent validation set. Higher accuracy was obtained for laboratory scanning as compared to on-line scanning of the 25 independent samples. The prediction accuracy for the laboratory and on-line measurements was classified as excellent/very good for pH (RPD = 2.69 and 2.14 and r2 = 0.86 and 0.78, respectively), and moderately good for CEC (RPD = 1.77 and 1.61 and r2 = 0.68 and 0.62, respectively) and Mgex (RPD = 1.72 and 1.49 and r2 = 0.66 and 0.67, respectively). For Caex, very good accuracy was calculated for laboratory method (RPD = 2.19 and r2 = 0.86), as compared to the poor accuracy reported for the on-line method (RPD = 1.30 and r2 = 0.61). The ability of collecting large number of data points per field area (about 12,800 point per 21 ha) and the simultaneous analysis of several soil properties without direct spectral response in the NIR range at relatively high operational speed and appreciable accuracy, encourage the recommendation of the on-line measurement system for site specific fertilisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing attention is being paid to the possible development of non-invasive tests for the assessment of the quality of Fruits. We propose a novel non-destructive method for the measurement of the internal optical properties of fruits and vegetables by means of lime-resolved reflectance spectroscopy in the visible and NIR range. A Fully automated instrumentation for time-resolved reflectance measurements was developed. It is based on mode-locked laser sources and electronics for time-correlated single photon counting, and provides a time-resolution of 120-160 ps. The system was used to probe the optical properties of several species and varieties of Fruits and vegetables in the red and NIR range (650-1000 nm). In most Fruits, the absorption line shape is dominated by the absorption peak of water, centred around 970 nm. Generally, the absorption spectra also show the spectral features typical of chlorophyll, with maximum at 675 nm. In particular, for what concerns apples, variations in peak intensity are observed depending on the variety, the degree of ripeness as well as the position on the apple. For all the species and varieties considered, the transport scattering coefficient decreases progressively upon increasing the wavelength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highly correlated ab initio calculations (CCSD(T)) are used to compute gas phase spectroscopic parameters of three isotopologues of the methyl acetate (CH3COOCH3, CD3COOCH3, and CH3COOCD3), searching to help experimental assignments and astrophysical detections. The molecule shows two conformers cis and trans separated by a barrier of 4457 cm−1. The potential energy surface presents 18 minima that intertransform through three internal rotation motions. To analyze the far infrared spectrum at low temperatures, a three-dimensional Hamiltonian is solved variationally. The two methyl torsion barriers are calculated to be 99.2 cm−1 (C–CH3) and 413.1 cm−1 (O–CH3), for the cis-conformer. The three fundamental torsional band centers of CH3COOCH3 are predicted to lie at 63.7 cm−1 (C–CH3), 136.1 cm−1 (O–CH3), and 175.8 cm−1 (C–O torsion) providing torsional state separations. For the 27 vibrational modes, anharmonic fundamentals and rovibrational parameters are provided. Computed parameters are compared with those fitted using experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When aqueous suspensions of gold nanorods are irradiated with a pulsing laser (808 nm), pressure waves appear even at low frequencies (pulse repetition rate of 25 kHz). We found that the pressure wave amplitude depends on the dynamics of the phenomenon. For fixed concentration and average laser current intensity, the amplitude of the pressure waves shows a trend of increasing with the pulse slope and the pulse maximum amplitude.We postulate that the detected ultrasonic pressure waves are a sort of shock waves that would be generated at the beginning of each pulse, because the pressure wave amplitude would be the result of the positive interference of all the individual shock waves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have analyzed the spectral sub-bandgap photoresponse of silicon (Si) samples implanted with vanadium (V) at different doses and subsequently processed by pulsed-laser melting. Samples with V concentration clearly above the insulator-metal transition limit show an important increase of the photoresponse with respect to a Si reference sample. Their photoresponse extends into the far infrared region and presents a sharp photoconductivity edge that moves towards lower photon energies as the temperature decreases. The increase of the value of the photoresponse is contrary to the classic understanding of recombination centers action and supports the predictions of the insulator-metal transition theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.