25 resultados para Industrial buildings Design and construction
em Universidad Politécnica de Madrid
Resumo:
This paper is presented in CIB: Management and Innovation Sustainable Built Environment 2011, as the study and analysis of the residential model of a rural area from the Iberian Peninsula, specifically applied to the case of the province of Cáceres, in the autonomous region of Extremadura, in Spain. To this end, from a database made up of building projects whose real costs are known, it is intended to establish the links of the different parameters studied through the corresponding functions of statistical analysis. One of the main objectives of this process is constituted by the possibility of establishing those design variables of higher economic importance, so as to keep an economic control of these parameters, generally geometrical and typological, from the very start of the project. And, in general, a higher optimization of resources in the construction of dwellings in the rural environment from their design is intended.
Resumo:
The Barriga Dam (Burgos, Spain) is a unique case study because its trapezoid spillway is located on the dam body and is composed of wedge-shaped concrete blocks (WSB) that include certain relevant improvements. This note summarizes the main features of the studies, the key aspects of the final design of the WSB and their placement on the dam, and important details of the spillway design. The design team concluded the study by showing the suitability of this enhanced technology for application to small dams and ponds in the short term, even with unit flows above 5 m2/s.
Resumo:
Nowadays computing platforms consist of a very large number of components that require to be supplied with diferent voltage levels and power requirements. Even a very small platform, like a handheld computer, may contain more than twenty diferent loads and voltage regulators. The power delivery designers of these systems are required to provide, in a very short time, the right power architecture that optimizes the performance, meets electrical specifications plus cost and size targets. The appropriate selection of the architecture and converters directly defines the performance of a given solution. Therefore, the designer needs to be able to evaluate a significant number of options in order to know with good certainty whether the selected solutions meet the size, energy eficiency and cost targets. The design dificulties of selecting the right solution arise due to the wide range of power conversion products provided by diferent manufacturers. These products range from discrete components (to build converters) to complete power conversion modules that employ diferent manufacturing technologies. Consequently, in most cases it is not possible to analyze all the alternatives (combinations of power architectures and converters) that can be built. The designer has to select a limited number of converters in order to simplify the analysis. In this thesis, in order to overcome the mentioned dificulties, a new design methodology for power supply systems is proposed. This methodology integrates evolutionary computation techniques in order to make possible analyzing a large number of possibilities. This exhaustive analysis helps the designer to quickly define a set of feasible solutions and select the best trade-off in performance according to each application. The proposed approach consists of two key steps, one for the automatic generation of architectures and other for the optimized selection of components. In this thesis are detailed the implementation of these two steps. The usefulness of the methodology is corroborated by contrasting the results using real problems and experiments designed to test the limits of the algorithms.
Resumo:
En la última década la potencia instalada de energía solar fotovoltaica ha crecido una media de un 49% anual y se espera que alcance el 16%del consumo energético mundial en el año 2050. La mayor parte de estas instalaciones se corresponden con sistemas conectados a la red eléctrica y un amplio porcentaje de ellas son instalaciones domésticas o en edificios. En el mercado ya existen diferentes arquitecturas para este tipo de instalaciones, entre las que se encuentras los módulos AC. Un módulo AC consiste en un inversor, también conocido como micro-inversor, que se monta en la parte trasera de un panel o módulo fotovoltaico. Esta tecnología ofrece modularidad, redundancia y la extracción de la máxima potencia de cada panel solar de la instalación. Además, la expansión de esta tecnología posibilitará una reducción de costes asociados a las economías de escala y a la posibilidad de que el propio usuario pueda componer su propio sistema. Sin embargo, el micro-inversor debe ser capaz de proporcionar una ganancia de tensión adecuada para conectar el panel solar directamente a la red, mientras mantiene un rendimiento aceptable en un amplio rango de potencias. Asimismo, los estándares de conexión a red deber ser satisfechos y el tamaño y el tiempo de vida del micro-inversor son factores que han de tenerse siempre en cuenta. En esta tesis se propone un micro-inversor derivado de la topología “forward” controlado en el límite entre los modos de conducción continuo y discontinuo (BCM por sus siglas en inglés). El transformador de la topología propuesta mantiene la misma estructura que en el convertidor “forward” clásico y la utilización de interruptores bidireccionales en el secundario permite la conexión directa del inversor a la red. Asimismo el método de control elegido permite obtener factor de potencia cercano a la unidad con una implementación sencilla. En la tesis se presenta el principio de funcionamiento y los principales aspectos del diseño del micro-inversor propuesto. Con la idea de mantener una solución sencilla y de bajo coste, se ha seleccionado un controlador analógico que está originalmente pensado para controlar un corrector del factor de potencia en el mismo modo de conducción que el micro-inversor “forward”. La tesis presenta las principales modificaciones necesarias, con especial atención a la detección del cruce por cero de la corriente (ZCD por sus siglas en inglés) y la compatibilidad del controlador con la inclusión de un algoritmo de búsqueda del punto de máxima potencia (MPPT por sus siglas en inglés). Los resultados experimentales muestran las limitaciones de la implementación elegida e identifican al transformador como el principal contribuyente a las pérdidas del micro-inversor. El principal objetivo de esta tesis es contribuir a la aplicación de técnicas de control y diseño de sistemas multifase en micro-inversores fotovoltaicos. En esta tesis se van a considerar dos configuraciones multifase diferentes aplicadas al micro-inversor “forward” propuesto. La primera consiste en una variación con conexión paralelo-serie que permite la utilización de transformadores con una relación de vueltas baja, y por tanto bien acoplados, para conseguir una ganancia de tensión adecuada con un mejor rendimiento. Esta configuración emplea el mismo control BCM cuando la potencia extraída del panel solar es máxima. Este método de control implica que la frecuencia de conmutación se incrementa considerablemente cuando la potencia decrece, lo que compromete el rendimiento. Por lo tanto y con la intención de mantener unos bueno niveles de rendimiento ponderado, el micro-inversor funciona en modo de conducción discontinuo (DCM, por sus siglas en inglés) cuando la potencia extraía del panel solar es menor que la máxima. La segunda configuración multifase considerada en esta tesis es la aplicación de la técnica de paralelo con entrelazado. Además se han considerado dos técnicas diferentes para decidir el número de fases activas: dependiendo de la potencia continua extraída del panel solar y dependiendo de la potencia instantánea demandada por el micro-inversor. La aplicación de estas técnicas es interesante en los sistemas fotovoltaicos conectados a la red eléctrica por la posibilidad que brindan de obtener un rendimiento prácticamente plano en un amplio rango de potencia. Las configuraciones con entrelazado se controlan en DCM para evitar la necesidad de un control de corriente, lo que es importante cuando el número de fases es alto. Los núcleos adecuados para todas las configuraciones multifase consideradas se seleccionan usando el producto de áreas. Una vez seleccionados los núcleos se ha realizado un diseño detallado de cada uno de los transformadores. Con la información obtenida de los diseños y los resultados de simulación, se puede analizar el impacto que el número de transformadores utilizados tiene en el tamaño y el rendimiento de las distintas configuraciones. Los resultados de este análisis, presentado en esta tesis, se utilizan posteriormente para comparar las distintas configuraciones. Muchas otras topologías se han presentado en la literatura para abordar los diferentes aspectos a considerar en los micro-inversores, que han sido presentados anteriormente. La mayoría de estas topologías utilizan un transformador de alta frecuencia para solventar el salto de tensión y evitar problemas de seguridad y de puesta a tierra. En cualquier caso, es interesante evaluar si topologías sin aislamiento galvánico son aptas para su utilización como micro-inversores. En esta tesis se presenta una revisión de inversores con capacidad de elevar tensión, que se comparan bajo las mismas especificaciones. El objetivo es proporcionar la información necesaria para valorar si estas topologías son aplicables en los módulos AC. Las principales contribuciones de esta tesis son: • La aplicación del control BCM a un convertidor “forward” para obtener un micro-inversor de una etapa sencillo y de bajo coste. • La modificación de dicho micro-inversor con conexión paralelo-series de transformadores que permite reducir la corriente de los semiconductores y una ganancia de tensión adecuada con transformadores altamente acoplados. • La aplicación de técnicas de entrelazado y decisión de apagado de fases en la puesta en paralelo del micro-inversor “forward”. • El análisis y la comparación del efecto en el tamaño y el rendimiento del incremento del número de transformadores en las diferentes configuraciones multifase. • La eliminación de las medidas y los lazos de control de corriente en las topologías multifase con la utilización del modo de conducción discontinuo y un algoritmo MPPT sin necesidad de medida de corriente. • La recopilación y comparación bajo las mismas especificaciones de topologías inversoras con capacidad de elevar tensión, que pueden ser adecuadas para la utilización como micro-inversores. Esta tesis está estructurada en seis capítulos. El capítulo 1 presenta el marco en que se desarrolla la tesis así como el alcance de la misma. En el capítulo 2 se recopilan las topologías existentes de micro-invesores con aislamiento y aquellas sin aislamiento cuya implementación en un módulo AC es factible. Asimismo se presenta la comparación entre estas topologías bajo las mismas especificaciones. El capítulo 3 se centra en el micro-inversor “forward” que se propone originalmente en esta tesis. La aplicación de las técnicas multifase se aborda en los capítulos 4 y 5, en los que se presentan los análisis en función del número de transformadores. El capítulo está orientado a la propuesta paralelo-serie mientras que la configuración con entrelazado se analiza en el capítulo 5. Por último, en el capítulo 6 se presentan las contribuciones de esta tesis y los trabajos futuros. ABSTRACT In the last decade the photovoltaic (PV) installed power increased with an average growth of 49% per year and it is expected to cover the 16% of the global electricity consumption by 2050. Most of the installed PV power corresponds to grid-connected systems, with a significant percentage of residential installations. In these PV systems, the inverter is essential since it is the responsible of transferring into the grid the extracted power from the PV modules. Several architectures have been proposed for grid-connected residential PV systems, including the AC-module technology. An AC-module consists of an inverter, also known as micro-inverter, which is attached to a PV module. The AC-module technology offers modularity, redundancy and individual MPPT of each module. In addition, the expansion of this technology will enable the possibility of economies of scale of mass market and “plug and play” for the user, thus reducing the overall cost of the installation. However, the micro-inverter must be able to provide the required voltage boost to interface a low voltage PV module to the grid while keeping an acceptable efficiency in a wide power range. Furthermore, the quality standards must be satisfied and size and lifetime of the solutions must be always considered. In this thesis a single-stage forward micro-inverter with boundary mode operation is proposed to address the micro-inverter requirements. The transformer in the proposed topology remains as in the classic forward converter and bidirectional switches in the secondary side allows direct connection to the grid. In addition the selected control strategy allows high power factor current with a simple implementation. The operation of the topology is presented and the main design issues are introduced. With the intention to propose a simple and low-cost solution, an analog controller for a PFC operated in boundary mode is utilized. The main necessary modifications are discussed, with the focus on the zero current detection (ZCD) and the compatibility of the controller with a MPPT algorithm. The experimental results show the limitations of the selected analog controller implementation and the transformer is identified as a main losses contributor. The main objective of this thesis is to contribute in the application of control and design multiphase techniques to the PV micro-inverters. Two different multiphase configurations have been applied to the forward micro-inverter proposed in this thesis. The first one consists of a parallel-series connected variation which enables the use of low turns ratio, i.e. well coupled, transformers to achieve a proper voltage boost with an improved performance. This multiphase configuration implements BCM control at maximum load however. With this control method the switching frequency increases significantly for light load operation, thus jeopardizing the efficiency. Therefore, in order to keep acceptable weighted efficiency levels, DCM operation is selected for low power conditions. The second multiphase variation considered in this thesis is the interleaved configuration with two different phase shedding techniques: depending on the DC power extracted from the PV panel, and depending on the demanded instantaneous power. The application of interleaving techniques is interesting in PV grid-connected inverters for the possibility of flat efficiency behavior in a wide power range. The interleaved variations of the proposed forward micro-inverter are operated in DCM to avoid the current loop, which is important when the number of phases is large. The adequate transformer cores for all the multiphase configurations are selected according to the area product parameter and a detailed design of each required transformer is developed. With this information and simulation results, the impact in size and efficiency of the number of transformer used can be assessed. The considered multiphase topologies are compared in this thesis according to the results of the introduced analysis. Several other topological solutions have been proposed to solve the mentioned concerns in AC-module application. The most of these solutions use a high frequency transformer to boost the voltage and avoid grounding and safety issues. However, it is of interest to assess if the non-isolated topologies are suitable for AC-module application. In this thesis a review of transformerless step-up inverters is presented. The compiled topologies are compared using a set benchmark to provide the necessary information to assess whether non-isolated topologies are suitable for AC-module application. The main contributions of this thesis are: • The application of the boundary mode control with constant off-time to a forward converter, to obtain a simple and low-cost single-stage forward micro-inverter. • A modification of the forward micro-inverter with primary-parallel secondary-series connected transformers to reduce the current stress and improve the voltage gain with highly coupled transformers. •The application of the interleaved configuration with different phase shedding strategies to the proposed forward micro-inverter. • An analysis and comparison of the influence in size and efficiency of increasing the number of transformers in the parallel-series and interleaved multiphase configurations. • Elimination of the current loop and current measurements in the multiphase topologies by adopting DCM operation and a current sensorless MPPT. • A compilation and comparison with the same specifications of suitable non-isolated step-up inverters. This thesis is organized in six chapters. In Chapter 1 the background of single-phase PV-connected systems is discussed and the scope of the thesis is defined. Chapter 2 compiles the existing solutions for isolated micro-inverters and transformerless step-up inverters suitable for AC-module application. In addition, the most convenient non-isolated inverters are compared using a defined benchmark. Chapter 3 focuses on the originally proposed single-stage forward micro-inverter. The application of multiphase techniques is addressed in Chapter 4 and Chapter 5, and the impact in different parameters of increasing the number of phases is analyzed. In Chapter 4 an original primary-parallel secondary-series variation of the forward micro-inverter is presented, while Chapter 5 focuses on the application of the interleaved configuration. Finally, Chapter 6 discusses the contributions of the thesis and the future work.
Resumo:
Building-integrated Photovoltaics (BIPV) is one of the most promising technologies enabling buildings to generate on-site part of their electricity needs while performing architectural functionalities. A clear example of BIPV products consists of semi-transparent photovoltaic modules (STPV), designed to replace the conventional glazing solutions in building façades. Accordingly, the active building envelope is required to perform multiple requirements such as provide solar shading to avoid overheating, supply solar gains and thermal insulation to reduce heat loads and improve daylight utilization. To date, various studies into STPV systems have focused on their energy performance based on existing simulation programs, or on the modelling, normally validated by limited experimental data, of the STPV modules thermal behaviour. Taking into account that very limited experimental research has been conducted on the energy performance of STPV elements and that the characterization in real operation conditions is necessary to promote an energetically efficient integration of this technology in the building envelope, an outdoor testing facility has been designed, developed and built at the Solar Energy Institute of the Technical University of Madrid. In this work, the methodology used in the definition of the testing facility, its capability and limitations are presented and discussed.
Resumo:
The need of the Bourbon monarchy to build a Naval Base in the Bay of Cartagena (Spain) during the eighteenth century, implied performing various actions on the environment which allowed the construction of the new dock. One of the priority actions was the transformation of the watershed of the streams that flowed into Mandaraches´s sea. For this reason, a dike was designed and constructed in the northern part of the city. The design of this great work, which was designed as a fortification of the city, was subject to considerable uncertainties. Its proximity to the city involved the demolition of several buildings in the San Roque´s neighborhood. The greater or lesser number of affected buildings and the value of the just indemnification for the expropriation of them, become decisive factors to determine if the work was viable for the Royal Estate or not.
Resumo:
Diseño conceptual de puentes de alta velocidad ferroviarios. Railroad bridges, in general, and those for high speed railways, in particular, demand very special conditions. The traffic loads are much higher than for road bridges. Loads due to braking and acceleration determine, due to their magnitude, the structural layout. Because of the speed of the vehicles there are specific dynamic effects which need to be considered. In order to ensure passenger comfort, compatible with speeds of up to 350 km/h, it is necessary to meet very demanding conditions with respect to stiffness, displacements and dynamic behavior. In this paper these conditions are briefly described and different typological possibilities to satisfy them are presented as well as the main construction methods applicable to this kind of bridges.
Resumo:
En el campo de la fusión nuclear y desarrollándose en paralelo a ITER (International Thermonuclear Experimental Reactor), el proyecto IFMIF (International Fusion Material Irradiation Facility) se enmarca dentro de las actividades complementarias encaminadas a solucionar las barreras tecnológicas que aún plantea la fusión. En concreto IFMIF es una instalación de irradiación cuya misión es caracterizar materiales resistentes a condiciones extremas como las esperadas en los futuros reactores de fusión como DEMO (DEMOnstration power plant). Consiste de dos aceleradores de deuterones que proporcionan un haz de 125 mA y 40 MeV cada uno, que al colisionar con un blanco de litio producen un flujo neutrónico intenso (1017 neutrones/s) con un espectro similar al de los neutrones de fusión [1], [2]. Dicho flujo neutrónico es empleado para irradiar los diferentes materiales candidatos a ser empleados en reactores de fusión, y las muestras son posteriormente examinadas en la llamada instalación de post-irradiación. Como primer paso en tan ambicioso proyecto, una fase de validación y diseño llamada IFMIFEVEDA (Engineering Validation and Engineering Design Activities) se encuentra actualmente en desarrollo. Una de las actividades contempladas en esta fase es la construcción y operación de una acelarador prototipo llamado LIPAc (Linear IFMIF Prototype Accelerator). Se trata de un acelerador de deuterones de alta intensidad idéntico a la parte de baja energía de los aceleradores de IFMIF. Los componentes del LIPAc, que será instalado en Japón, son suministrados por diferentes países europeos. El acelerador proporcionará un haz continuo de deuterones de 9 MeV con una potencia de 1.125 MW que tras ser caracterizado con diversos instrumentos deberá pararse de forma segura. Para ello se requiere un sistema denominado bloque de parada (Beam Dump en inglés) que absorba la energía del haz y la transfiera a un sumidero de calor. España tiene el compromiso de suministrar este componente y CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) es responsable de dicha tarea. La pieza central del bloque de parada, donde se para el haz de iones, es un cono de cobre con un ángulo de 3.5o, 2.5 m de longitud y 5 mm de espesor. Dicha pieza está refrigerada por agua que fluye en su superficie externa por el canal que se forma entre el cono de cobre y otra pieza concéntrica con éste. Este es el marco en que se desarrolla la presente tesis, cuyo objeto es el diseño del sistema de refrigeración del bloque de parada del LIPAc. El diseño se ha realizado utilizando un modelo simplificado unidimensional. Se han obtenido los parámetros del agua (presión, caudal, pérdida de carga) y la geometría requerida en el canal de refrigeración (anchura, rugosidad) para garantizar la correcta refrigeración del bloque de parada. Se ha comprobado que el diseño permite variaciones del haz respecto a la situación nominal siendo el flujo crítico calorífico al menos 2 veces superior al nominal. Se han realizado asimismo simulaciones fluidodinámicas 3D con ANSYS-CFX en aquellas zonas del canal de refrigeración que lo requieren. El bloque de parada se activará como consecuencia de la interacción del haz de partículas lo que impide cualquier cambio o reparación una vez comenzada la operación del acelerador. Por ello el diseño ha de ser muy robusto y todas las hipótesis utilizadas en la realización de éste deben ser cuidadosamente comprobadas. Gran parte del esfuerzo de la tesis se centra en la estimación del coeficiente de transferencia de calor que es determinante en los resultados obtenidos, y que se emplea además como condición de contorno en los cálculos mecánicos. Para ello por un lado se han buscado correlaciones cuyo rango de aplicabilidad sea adecuado para las condiciones del bloque de parada (canal anular, diferencias de temperatura agua-pared de decenas de grados). En un segundo paso se han comparado los coeficientes de película obtenidos a partir de la correlación seleccionada (Petukhov-Gnielinski) con los que se deducen de simulaciones fluidodinámicas, obteniendo resultados satisfactorios. Por último se ha realizado una validación experimental utilizando un prototipo y un circuito hidráulico que proporciona un flujo de agua con los parámetros requeridos en el bloque de parada. Tras varios intentos y mejoras en el experimento se han obtenido los coeficientes de película para distintos caudales y potencias de calentamiento. Teniendo en cuenta la incertidumbre de las medidas, los valores experimentales concuerdan razonablemente bien (en el rango de 15%) con los deducidos de las correlaciones. Por motivos radiológicos es necesario controlar la calidad del agua de refrigeración y minimizar la corrosión del cobre. Tras un estudio bibliográfico se identificaron los parámetros del agua más adecuados (conductividad, pH y concentración de oxígeno disuelto). Como parte de la tesis se ha realizado asimismo un estudio de la corrosión del circuito de refrigeración del bloque de parada con el doble fin de determinar si puede poner en riesgo la integridad del componente, y de obtener una estimación de la velocidad de corrosión para dimensionar el sistema de purificación del agua. Se ha utilizado el código TRACT (TRansport and ACTivation code) adaptándalo al caso del bloque de parada, para lo cual se trabajó con el responsable (Panos Karditsas) del código en Culham (UKAEA). Los resultados confirman que la corrosión del cobre en las condiciones seleccionadas no supone un problema. La Tesis se encuentra estructurada de la siguiente manera: En el primer capítulo se realiza una introducción de los proyectos IFMIF y LIPAc dentro de los cuales se enmarca esta Tesis. Además se describe el bloque de parada, siendo el diseño del sistema de rerigeración de éste el principal objetivo de la Tesis. En el segundo y tercer capítulo se realiza un resumen de la base teórica así como de las diferentes herramientas empleadas en el diseño del sistema de refrigeración. El capítulo cuarto presenta los resultados del relativos al sistema de refrigeración. Tanto los obtenidos del estudio unidimensional, como los obtenidos de las simulaciones fluidodinámicas 3D mediante el empleo del código ANSYS-CFX. En el quinto capítulo se presentan los resultados referentes al análisis de corrosión del circuito de refrigeración del bloque de parada. El capítulo seis se centra en la descripción del montaje experimental para la obtención de los valores de pérdida de carga y coeficiente de transferencia del calor. Asimismo se presentan los resultados obtenidos en dichos experimentos. Finalmente encontramos un capítulo de apéndices en el que se describen una serie de experimentos llevados a cabo como pasos intermedios en la obtención del resultado experimental del coeficiente de película. También se presenta el código informático empleado para el análisis unidimensional del sistema de refrigeración del bloque de parada llamado CHICA (Cooling and Heating Interaction and Corrosion Analysis). ABSTRACT In the nuclear fusion field running in parallel to ITER (International Thermonuclear Experimental Reactor) as one of the complementary activities headed towards solving the technological barriers, IFMIF (International Fusion Material Irradiation Facility) project aims to provide an irradiation facility to qualify advanced materials resistant to extreme conditions like the ones expected in future fusion reactors like DEMO (DEMOnstration Power Plant). IFMIF consists of two constant wave deuteron accelerators delivering a 125 mA and 40 MeV beam each that will collide on a lithium target producing an intense neutron fluence (1017 neutrons/s) with a similar spectra to that of fusion neutrons [1], [2]. This neutron flux is employed to irradiate the different material candidates to be employed in the future fusion reactors, and the samples examined after irradiation at the so called post-irradiative facilities. As a first step in such an ambitious project, an engineering validation and engineering design activity phase called IFMIF-EVEDA (Engineering Validation and Engineering Design Activities) is presently going on. One of the activities consists on the construction and operation of an accelerator prototype named LIPAc (Linear IFMIF Prototype Accelerator). It is a high intensity deuteron accelerator identical to the low energy part of the IFMIF accelerators. The LIPAc components, which will be installed in Japan, are delivered by different european countries. The accelerator supplies a 9 MeV constant wave beam of deuterons with a power of 1.125 MW, which after being characterized by different instruments has to be stopped safely. For such task a beam dump to absorb the beam energy and take it to a heat sink is needed. Spain has the compromise of delivering such device and CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) is responsible for such task. The central piece of the beam dump, where the ion beam is stopped, is a copper cone with an angle of 3.5o, 2.5 m long and 5 mm width. This part is cooled by water flowing on its external surface through the channel formed between the copper cone and a concentric piece with the latter. The thesis is developed in this realm, and its objective is designing the LIPAc beam dump cooling system. The design has been performed employing a simplified one dimensional model. The water parameters (pressure, flow, pressure loss) and the required annular channel geometry (width, rugoisty) have been obtained guaranteeing the correct cooling of the beam dump. It has been checked that the cooling design allows variations of the the beam with respect to the nominal position, being the CHF (Critical Heat Flux) at least twice times higher than the nominal deposited heat flux. 3D fluid dynamic simulations employing ANSYS-CFX code in the beam dump cooling channel sections which require a more thorough study have also been performed. The beam dump will activateasaconsequenceofthe deuteron beam interaction, making impossible any change or maintenance task once the accelerator operation has started. Hence the design has to be very robust and all the hypotheses employed in the design mustbecarefully checked. Most of the work in the thesis is concentrated in estimating the heat transfer coefficient which is decisive in the obtained results, and is also employed as boundary condition in the mechanical analysis. For such task, correlations which applicability range is the adequate for the beam dump conditions (annular channel, water-surface temperature differences of tens of degrees) have been compiled. In a second step the heat transfer coefficients obtained from the selected correlation (Petukhov- Gnielinski) have been compared with the ones deduced from the 3D fluid dynamic simulations, obtaining satisfactory results. Finally an experimental validation has been performed employing a prototype and a hydraulic circuit that supplies a flow with the requested parameters in the beam dump. After several tries and improvements in the experiment, the heat transfer coefficients for different flows and heating powers have been obtained. Considering the uncertainty in the measurements the experimental values agree reasonably well (in the order of 15%) with the ones obtained from the correlations. Due to radiological reasons the quality of the cooling water must be controlled, hence minimizing the copper corrosion. After performing a bibligraphic study the most adequate water parameters were identified (conductivity, pH and dissolved oxygen concentration). As part of this thesis a corrosion study of the beam dump cooling circuit has been performed with the double aim of determining if corrosion can pose a risk for the copper beam dump , and obtaining an estimation of the corrosion velocitytodimension the water purification system. TRACT code(TRansport and ACTivation) has been employed for such study adapting the code for the beam dump case. For such study a collaboration with the code responsible (Panos Karditsas) at Culham (UKAEA) was established. The work developed in this thesis has supposed the publication of three articles in JCR journals (”Journal of Nuclear Materials” y ”Fusion Engineering and Design”), as well as presentations in more than four conferences and relevant meetings.
Resumo:
This Doctoral Thesis entitled Contribution to the analysis, design and assessment of compact antenna test ranges at millimeter wavelengths aims to deepen the knowledge of a particular antenna measurement system: the compact range, operating in the frequency bands of millimeter wavelengths. The thesis has been developed at Radiation Group (GR), an antenna laboratory which belongs to the Signals, Systems and Radiocommunications department (SSR), from Technical University of Madrid (UPM). The Radiation Group owns an extensive experience on antenna measurements, running at present four facilities which operate in different configurations: Gregorian compact antenna test range, spherical near field, planar near field and semianechoic arch system. The research work performed in line with this thesis contributes the knowledge of the first measurement configuration at higher frequencies, beyond the microwaves region where Radiation Group features customer-level performance. To reach this high level purpose, a set of scientific tasks were sequentially carried out. Those are succinctly described in the subsequent paragraphs. A first step dealed with the State of Art review. The study of scientific literature dealed with the analysis of measurement practices in compact antenna test ranges in addition with the particularities of millimeter wavelength technologies. Joint study of both fields of knowledge converged, when this measurement facilities are of interest, in a series of technological challenges which become serious bottlenecks at different stages: analysis, design and assessment. Thirdly after the overview study, focus was set on Electromagnetic analysis algorithms. These formulations allow to approach certain electromagnetic features of interest, such as field distribution phase or stray signal analysis of particular structures when they interact with electromagnetic waves sources. Properly operated, a CATR facility features electromagnetic waves collimation optics which are large, in terms of wavelengths. Accordingly, the electromagnetic analysis tasks introduce an extense number of mathematic unknowns which grow with frequency, following different polynomic order laws depending on the used algorithmia. In particular, the optics configuration which was of our interest consisted on the reflection type serrated edge collimator. The analysis of these devices requires a flexible handling of almost arbitrary scattering geometries, becoming this flexibility the nucleus of the algorithmia’s ability to perform the subsequent design tasks. This thesis’ contribution to this field of knowledge consisted on reaching a formulation which was powerful at the same time when dealing with various analysis geometries and computationally speaking. Two algorithmia were developed. While based on the same principle of hybridization, they reached different order Physics performance at the cost of the computational efficiency. Inter-comparison of their CATR design capabilities was performed, reaching both qualitative as well as quantitative conclusions on their scope. In third place, interest was shifted from analysis - design tasks towards range assessment. Millimetre wavelengths imply strict mechanical tolerances and fine setup adjustment. In addition, the large number of unknowns issue already faced in the analysis stage appears as well in the on chamber field probing stage. Natural decrease of dynamic range available by semiconductor millimeter waves sources requires in addition larger integration times at each probing point. These peculiarities increase exponentially the difficulty of performing assessment processes in CATR facilities beyond microwaves. The bottleneck becomes so tight that it compromises the range characterization beyond a certain limit frequency which typically lies on the lowest segment of millimeter wavelength frequencies. However the value of range assessment moves, on the contrary, towards the highest segment. This thesis contributes this technological scenario developing quiet zone probing techniques which achieves substantial data reduction ratii. Collaterally, it increases the robustness of the results to noise, which is a virtual rise of the setup’s available dynamic range. In fourth place, the environmental sensitivity of millimeter wavelengths issue was approached. It is well known the drifts of electromagnetic experiments due to the dependance of the re sults with respect to the surrounding environment. This feature relegates many industrial practices of microwave frequencies to the experimental stage, at millimeter wavelengths. In particular, evolution of the atmosphere within acceptable conditioning bounds redounds in drift phenomena which completely mask the experimental results. The contribution of this thesis on this aspect consists on modeling electrically the indoor atmosphere existing in a CATR, as a function of environmental variables which affect the range’s performance. A simple model was developed, being able to handle high level phenomena, such as feed - probe phase drift as a function of low level magnitudes easy to be sampled: relative humidity and temperature. With this model, environmental compensation can be performed and chamber conditioning is automatically extended towards higher frequencies. Therefore, the purpose of this thesis is to go further into the knowledge of millimetre wavelengths involving compact antenna test ranges. This knowledge is dosified through the sequential stages of a CATR conception, form early low level electromagnetic analysis towards the assessment of an operative facility, stages for each one of which nowadays bottleneck phenomena exist and seriously compromise the antenna measurement practices at millimeter wavelengths.
Resumo:
Virtual certification partially substitutes by computer simulations the experimental techniques required for rail vehicle certification. In this paper, several works were these techniques were used in the vehicle design and track maintenance processes are presented. Dynamic simulation of multibody systems was used to virtually apply the EN14363 standard to certify the dynamic behaviour of vehicles. The works described are: assessment of a freight bogie design adapted to meter-gauge, assessment of a railway track layout for a subway network, freight bogie design with higher speed and axle load, and processing of the data acquired by a track recording vehicle for track maintenance.
Resumo:
En numerosas ocasiones a lo largo de la historia la imaginación de los creadores ha ido por delante de las posibilidades técnicas de cada momento. Así, muchas de estas nuevas ideas han requerido largos periodos de tiempo para materializarse como realidad construida, hasta que el desarrollo tecnológico e industrial hubo alcanzado un grado de madurez suficiente. En el campo de la arquitectura, estas limitaciones técnicas se han ido acotando paulatinamente hasta desembocar en la situación actual en la que cualquier planteamiento formal puede ser representado gráficamente y analizado desde un punto de vista estructural, superádose de este modo la barrera existente históricamente en el tratamiento de las formas. A lo largo del presente tesis doctoral se analiza cómo la formulación del Método de los Elementos Finitos en la década de los cincuenta y las curvas de Bézier en la década de los sesenta del siglo pasado y la posterior generalización de los ordenadores personales y de los programas informáticos asociados (C.A.D. y F.E.M. principalmente) en los estudios de arquitectura e ingeniería a partir de la década de los noventa, posibilitó el desarrollo de cualquier propuesta arquitectónica, por compleja que ésta fuese, provocando una verdadera revolución a nivel formal en el mundo de la arquitectura, especialmente en el campo de la edificación singular o icónica. Se estudia este proceso a través de ocho edificios; cuatro anteriores y otros tantos posteriores a la desaparición de la barrera anteriormente referida, establecida de forma simbólica en la década de los años ochenta del siglo XX: Frontón de Recoletos en Madrid, Edificio Seagram en Nueva York, Habitat ’67 en Montreal, Ópera de Sídney, museo Guggenheim de Bilbao, ampliación del Victoria & Albert Museum en Londres, tanatorio “Meiso no Mori” en Gifu y nueva sede de la CCTV en Pekín. De entre ellos, la Ópera de Sídney, obra del arquitecto danés Jørn Utzon, condensa gran parte de los aspectos relevantes investigados en relación a la influencia que los métodos de representación y análisis estructural ejercen en la concepción y construcción de las obras de arquitectura. Por este motivo y por considerarse un hito de la arquitectura a nivel global se toma como caso de estudio. La idea general del edificio, que data de 1956, se enmarca en una época inmediatamente anterior a la del desarrollo científico y tecnológico anteriormente referido. Esta ausencia de herramientas de diseño disponibles acordes a la complejidad formal de la propuesta planteada condicionó enormente la marcha del proyecto, dilatándose dramáticamente en el tiempo y disparándose su coste hasta el punto de que el propio arquitecto danés fue separado de las obras antes de su conclusión. Además, la solución estructural finalmente construida de las cubiertas dista mucho de la prevista por Utzon inicialmente. Donde él había imaginado unas finas láminas de hormigón flotando sobre el paisaje se materializó una estructura más pesada, formada por costillas pretensadas de hormigón con unas secciones notablemente mayores. La forma también debió ser modificada de modo ostensible respecto a la propuesta inicial. Si este edificio se pretendiese construir en la actualidad, con toda seguridad el curso de los acontecimientos se desarrollaría por senderos muy diferentes. Ante este supuesto, se plantean las siguientes cuestiones: ¿sería posible realizar un análisis estructural de la cubierta laminar planteada por Utzon inicialmente en el concurso con las herramientas disponibles en la actualidad?; ¿sería dicha propuesta viable estructuralmente?. A lo largo de las siguientes páginas se pretende dar respuesta a estas cuestiones, poniendo de relieve el impacto que los ordenadores personales y los programas informáticos asociados han tenido en la manera de concebir y construir edificios. También se han analizado variantes a la solución laminar planteada en la fase de concurso, a través de las cuales, tratando en la medida de lo posible de ajustarse a las sugerencias que Ove Arup y su equipo realizaron a Jørn Utzon a lo largo del dilatado proceso de proyecto, mejorar el comportamiento general de la estructura del edificio. Por último, se ha pretendido partir de cero y plantear, desde una perspectiva contemporánea, posibles enfoques metodológicos aplicables a la búsqueda de soluciones estructurales compatibles con la forma propuesta originalmente por Utzon para las cubiertas de la Ópera de Sídney y que nunca llegó a ser construida (ni analizada), considerando para ello los medios tecnológicos, científicos e industriales disponibles en la actualidad. Abstract On numerous occasions throughout history the imagination of creators has gone well beyond of the technical possibilities of their time. Many new ideas have required a long period to materialize, until the technological and industrial development had time to catch up. In the architecture field, these technical limitations have gradually tightened leading to the current situation in which any formal approach can be represented and analyzed from a structural point of view, thus concluding that the structural analysis and the graphical representation’s barrier in the development of architectural projects has dissappeared. Throughout the following pages it is examined how the development of the Finite Element Method in the fifties and the Bezier curves in the sixties of the last century and the subsequent spread of personal computers and specialized software in the architectural and engineering offices from the nineties, enabled the development of any architectural proposal independently of its complexity. This has caused a revolution at a formal level in architecture, especially in the field of iconic building. This process is analyzed through eight buildings, four of them before and another four after the disappearance of the above mentioned barrier, roughly established in the eighties of the last century: Fronton Recoletos in Madrid, Seagram Building in New York Habitat '67 in Montreal, Sydney Opera House, Guggenheim Museum Bilbao, Victoria & Albert Museum extension in London, Crematorium “Meiso no Mori” in Gifu and the new CCTV headquarters in Beijing. Among them, the Sydney Opera House, designed by Danish architect Jørn Utzon, condenses many of the main aspects previously investigated regarding the impact of representation methods and structural analysis on the design and construction of architectural projects. For this reason and also because it is considered a global architecture milestone, it is selected as a case study. The building’s general idea, which dates from 1956, is framed at a time immediately preceding the above mentioned scientific and technological development. This lack of available design tools in accordance with the proposal’s formal complexity conditioned enormously the project’s progress, leading to a dramatic delay and multiplying the final budget disproportionately to the point that the Danish architect himself was separated from the works before completion. Furthermore, the built structure differs dramatically from the architect’s initial vision. Where Utzon saw a thin concrete shell floating over the landscape a heavier structure was built, consisting of prestressed concrete ribs with a significantly greater size. The geometry also had to be modified. If this building were to built today, the course of events surely would walk very different paths. Given this assumption, a number of questions could then be formulated: Would it be possible to perform a structural analysis of Utzon’s initially proposed competition-free-ways roof’s geometry with the tools available nowadays?; Would this proposal be structurally feasable?. Throughout the following pages it is intended to clarify this issues, highlighting personal computers and associated software’s impact in building design and construction procedures, especially in the field of iconic building. Variants have also been analyzed for the laminar solution proposed in the competition phase, through which, trying as far as possible to comply with the suggestions that Ove Arup and his team did to Jørn Utzon along the lengthy process project, improving the overall performance of the building structure. Finally, we have started from scratch and analyzed, from a contemporary perspective, possible structural solutions compatible with Utzon’s Opera House’s original geometry and vision –proposal that was never built (nor even analyzed)-, taking into consideration the technological, scientific and industrial means currently available.
Resumo:
This article presents the design, kinematic model and communication architecture for the multi-agent robotic system called SMART. The philosophy behind this kind of system requires the communication architecture to contemplate the concurrence of the whole system. The proposed architecture combines different communication technologies (TCP/IP and Bluetooth) under one protocol designed for the cooperation among agents and other elements of the system such as IP-Cameras, image processing library, path planner, user Interface, control block and data block. The high level control is modeled by Work-Flow Petri nets and implemented in C++ and C♯♯. Experimental results show the performance of the designed architecture.
Resumo:
Nearly 3000 slaughterhouses (74% of them public facilities) were built in Spain during the last decades of the nineteenth century and the first half of the twentieth century. The need to comply with new technical requirements and regulations on the hygiene of the meat passed in the 70s and the gradual replacement of public facilities by larger and more modern private slaughterhouses have subsequently led to the closure and abandonment of many of these buildings. Public slaughterhouses generally consisted of several single-storey and open-plan buildings located around a courtyard. Although originally they were preferably located on the outskirts of the towns, many slaughterhouses are now placed inside the built up areas, due to the urban development. The present work aims to contribute to a better understanding of these agro-industrial buildings and to provide ideas for their conservation and reuse. A review on the historical evolution and the architectural features of the public slaughterhouses in Spain is presented and different examples of old vacant slaughterhouses reused to accommodate libraries, offices, community centres, exhibition halls or sports centres, among others, are shown in the paper.
Resumo:
The design, construction and operation of the tunnels of M-30, the major ring road in the city of Madrid (Spain), represent a very interesting project in wich a wide variety of situations -geometrical, topographical, etc.- had to be covered, in variable conditions of traffic. For that reasons, the M-30 project is a remarkable technical challenge, which, after its completion, turned into an international reference. From the "design for safety" perspective, a holistic approach has been used to deal with new technologies, integration of systems and development of the procedures to reach the maximum level. However, one of the primary goals has been to achieve reasonable homogeneity characteristics which can permit operate a netword of tunels as one only infraestructure. In the case of the ventilation system the mentioned goals have implied innovative solutions and coordination efforts of great interest. Consequently, this paper describes the principal ideas underlying the conceptual solution developed focusing on the principal peculiarities of the project.
Resumo:
En el Código Técnico de la Edificación se define el riesgo como medida del alcance del peligro que representa un evento no deseado para las personas, expresado en términos de probabilidad vinculada a las consecuencias de un evento, también se expresa como Exigencia Básica de Resistencia y Estabilidad, que estas serán las adecuadas para que no se generen riesgos indebidos manteniendo la resistencia y estabilidad frente a las acciones e influencias previsibles durante la construcción y usos previstos de los edificios, y que además, los posibles eventos extraordinarios que puedan producirse no originen consecuencias desproporcionadas respecto a la causa original. Es ahora donde la gestión de riesgos juega un papel muy importante en la sociedad moderna, siendo esta cada vez más exigente con los resultados y calidad de productos y servicios, además de cumplir también con la responsabilidad jurídica que trae la concepción, diseño y construcción de proyectos de gran envergadura como los son la obra civil y edificación. La obra civil destinada al sector industrial debe ser ejecutada con la mayor precisión posible, pues requiere la instalación de complejos equipos y sistemas productivos que pueden producir esfuerzos dinámicos que muchas veces no se consideran en el diseño de los cimientos que lo soportan, razón por la cual interviene la gestión de riesgos para conocer y reducir los posibles riesgos de fallos que se puedan generar y así intentar aproximarse cada vez más al desarrollo de diseños eficientes y confiables, afianzando la exactitud y minimizando errores en la producción y elaboración de piezas, sistemas y equipos de las distintas áreas productivas de la industria. El presente trabajo de investigación se centra en el estudio de los riesgos técnicos existentes en el diseño y ejecución de cimentaciones para maquinarias, mediante la aplicación de varios métodos de investigación, a fin de intentar cubrir los aspectos más importantes que puedan incurrir en una posible causa de fallo de la estructura, evaluando el acoplamiento entre el sistema máquina-cimiento-suelo. Risk is defined, by the Technical Building Code (Código Técnico de la Edificación, CTE) as a measure of the scope of the hazard of an undesired event for people, expressed in terms of probability related to the consequences of an event, also is expressed as a Basic Requirement Strength and Stability these will be appropriate to not cause undue risk maintaining strength and stability against predictable actions and influences during construction and expected uses of the buildings. Nowadays, Risk Management is an important process in modern society, becoming ever more demanding about the results and quality of products and services, and also complies with the legal responsibility that brings the conception, design and construction of large projects as are civil engineering and construction projects. Civil work as a part of industry must be performed as accurately as possible, requiring the installation of sophisticated equipment and production systems which can produce dynamic forces that often are not considered in the design of the foundations, this is the reason why risk management is involved to understand and reduce the risks of failures that may arise and try to move closer to the development of efficient and reliable designs, strengthening the accuracy and minimizing errors in the production and processing of parts, systems and equipments from different production areas of the industry. This paper is a study of existing technical risks in the design and execution of foundations for machinery, through the application of various research methods, in order to try to cover the most important aspects that may produce the failure of the structure, evaluating the union between the machine-foundation system and soil.