22 resultados para ISO 14001 environmental standard
em Universidad Politécnica de Madrid
Resumo:
This paper presents a new verification procedure for sound source coverage according to ISO 140?5 requirements. The ISO 140?5 standard applies to the measurement of façade insulation and requires a sound source able to achieve a sufficiently uniform sound field in free field conditions on the façade under study. The proposed method involves the electroacoustic characterisation of the sound source in laboratory free field conditions (anechoic room) and the subsequent prediction by computer simulation of the sound free field radiated on a rectangular surface equal in size to the façade being measured. The loudspeaker is characterised in an anechoic room under laboratory controlled conditions, carefully measuring directivity, and then a computer model is designed to calculate the acoustic free field coverage for different loudspeaker positions and façade sizes. For each sound source position, the method provides the maximum direct acoustic level differences on a façade specimen and therefore determines whether the loudspeaker verifies the maximum allowed level difference of 5 dB (or 10 dB for façade dimensions greater than 5 m) required by the ISO standard. Additionally, the maximum horizontal dimension of the façade meeting the standard is calculated and provided for each sound source position, both with the 5 dB and 10 dB criteria. In the last section of the paper, the proposed procedure is compared with another method used by the authors in the past to achieve the same purpose: in situ outdoor measurements attempting to recreate free field conditions. From this comparison, it is concluded that the proposed method is able to reproduce the actual measurements with high accuracy, for example, the ground reflection effect, at least at low frequencies, which is difficult to avoid in the outdoor measurement method, and it is fully eliminated with the proposed method to achieve the free field requisite.
Resumo:
The International Standard ISO 140-5 on field measurements of airborne sound insulation of façades establishes that the directivity of the measurement loudspeaker should be such that the variation in the local direct sound pressure level (ΔSPL) on the sample is ΔSPL < 5 dB (or ΔSPL < 10 dB for large façades). This condition is usually not very easy to accomplish nor is it easy to verify whether the loudspeaker produces such a uniform level. Direct sound pressure levels on the ISO standard façade essentially depend on the distance and directivity of the loudspeaker used. This paper presents a comprehensive analysis of the test geometry for measuring sound insulation and explains how the loudspeaker directivity, combined with distance, affects the acoustic level distribution on the façade. The first sections of the paper are focused on analysing the measurement geometry and its influence on the direct acoustic level variations on the façade. The most favourable and least favourable positions to minimise these direct acoustic level differences are found, and the angles covered by the façade in the reference system of the loudspeaker are also determined. Then, the maximum dimensions of the façade that meet the conditions of the ISO 140-5 standard are obtained for the ideal omnidirectional sound source and the piston radiating in an infinite baffle, which is chosen as the typical radiation pattern for loudspeakers. Finally, a complete study of the behaviour of different loudspeaker radiation models (such as those usually utilised in the ISO 140-5 measurements) is performed, comparing their radiation maps on the façade for searching their maximum dimensions and the most appropriate radiation configurations.
Resumo:
OntoTag - A Linguistic and Ontological Annotation Model Suitable for the Semantic Web
1. INTRODUCTION. LINGUISTIC TOOLS AND ANNOTATIONS: THEIR LIGHTS AND SHADOWS
Computational Linguistics is already a consolidated research area. It builds upon the results of other two major ones, namely Linguistics and Computer Science and Engineering, and it aims at developing computational models of human language (or natural language, as it is termed in this area). Possibly, its most well-known applications are the different tools developed so far for processing human language, such as machine translation systems and speech recognizers or dictation programs.
These tools for processing human language are commonly referred to as linguistic tools. Apart from the examples mentioned above, there are also other types of linguistic tools that perhaps are not so well-known, but on which most of the other applications of Computational Linguistics are built. These other types of linguistic tools comprise POS taggers, natural language parsers and semantic taggers, amongst others. All of them can be termed linguistic annotation tools.
Linguistic annotation tools are important assets. In fact, POS and semantic taggers (and, to a lesser extent, also natural language parsers) have become critical resources for the computer applications that process natural language. Hence, any computer application that has to analyse a text automatically and ‘intelligently’ will include at least a module for POS tagging. The more an application needs to ‘understand’ the meaning of the text it processes, the more linguistic tools and/or modules it will incorporate and integrate.
However, linguistic annotation tools have still some limitations, which can be summarised as follows:
1. Normally, they perform annotations only at a certain linguistic level (that is, Morphology, Syntax, Semantics, etc.).
2. They usually introduce a certain rate of errors and ambiguities when tagging. This error rate ranges from 10 percent up to 50 percent of the units annotated for unrestricted, general texts.
3. Their annotations are most frequently formulated in terms of an annotation schema designed and implemented ad hoc.
A priori, it seems that the interoperation and the integration of several linguistic tools into an appropriate software architecture could most likely solve the limitations stated in (1). Besides, integrating several linguistic annotation tools and making them interoperate could also minimise the limitation stated in (2). Nevertheless, in the latter case, all these tools should produce annotations for a common level, which would have to be combined in order to correct their corresponding errors and inaccuracies. Yet, the limitation stated in (3) prevents both types of integration and interoperation from being easily achieved.
In addition, most high-level annotation tools rely on other lower-level annotation tools and their outputs to generate their own ones. For example, sense-tagging tools (operating at the semantic level) often use POS taggers (operating at a lower level, i.e., the morphosyntactic) to identify the grammatical category of the word or lexical unit they are annotating. Accordingly, if a faulty or inaccurate low-level annotation tool is to be used by other higher-level one in its process, the errors and inaccuracies of the former should be minimised in advance. Otherwise, these errors and inaccuracies would be transferred to (and even magnified in) the annotations of the high-level annotation tool.
Therefore, it would be quite useful to find a way to
(i) correct or, at least, reduce the errors and the inaccuracies of lower-level linguistic tools;
(ii) unify the annotation schemas of different linguistic annotation tools or, more generally speaking, make these tools (as well as their annotations) interoperate.
Clearly, solving (i) and (ii) should ease the automatic annotation of web pages by means of linguistic tools, and their transformation into Semantic Web pages (Berners-Lee, Hendler and Lassila, 2001). Yet, as stated above, (ii) is a type of interoperability problem. There again, ontologies (Gruber, 1993; Borst, 1997) have been successfully applied thus far to solve several interoperability problems. Hence, ontologies should help solve also the problems and limitations of linguistic annotation tools aforementioned.
Thus, to summarise, the main aim of the present work was to combine somehow these separated approaches, mechanisms and tools for annotation from Linguistics and Ontological Engineering (and the Semantic Web) in a sort of hybrid (linguistic and ontological) annotation model, suitable for both areas. This hybrid (semantic) annotation model should (a) benefit from the advances, models, techniques, mechanisms and tools of these two areas; (b) minimise (and even solve, when possible) some of the problems found in each of them; and (c) be suitable for the Semantic Web. The concrete goals that helped attain this aim are presented in the following section.
2. GOALS OF THE PRESENT WORK
As mentioned above, the main goal of this work was to specify a hybrid (that is, linguistically-motivated and ontology-based) model of annotation suitable for the Semantic Web (i.e. it had to produce a semantic annotation of web page contents). This entailed that the tags included in the annotations of the model had to (1) represent linguistic concepts (or linguistic categories, as they are termed in ISO/DCR (2008)), in order for this model to be linguistically-motivated; (2) be ontological terms (i.e., use an ontological vocabulary), in order for the model to be ontology-based; and (3) be structured (linked) as a collection of ontology-based
Resumo:
This paper presents a general view of the telematic voting system developed by its authors, with a special emphasis on the important role that smart cards play in this scenario. The use of smart cards as basic pieces for providing secure cryptographic operations in this type of voting scheme is justified. The differences and advantages of Java Cards in comparison with the ?classical? smart cards (those that completely conform to the ISO/IEC 7816 standard) are also discussed. As an example, the paper describes one of the applets implemented in the voting Java Card as part of the general telematic voting application.
Resumo:
La tecnología de la información y su utilización en las empresas ha sido y es un elemento de debate ya que las organizaciones cuentan con grandes éxitos y grandes fracasos. Gran parte de estos últimos asociados a una falta de visión estratégica integral en relación a la utilización de TI en la organización lo que ha dado lugar al área del conocimiento llamada Gobernanza de TI y a la publicación de numerosos marcos y estándares. Un campo sensible y económicamente muy importante tanto para Uruguay como a nivel mundial son las empresas medianas y pequeñas (PyMEs), las que no logran aplicar de manera efectiva los marcos y estándares, es por esta razón que el objetivo final de esta tesis es el de construir un marco que permita a las PyMEs incorporar un marco efectivo para gobernar y gestionar TI adecuadamente obteniendo el valor esperado de las inversiones realizadas. Para alcanzar este objetivo general se ha realizado un estudio de campo que permita conocer la situación de la gobernanza y la gestión de TI en PyMEs del Uruguay; a partir de este estudio se pudo analizar cuáles son los factores más significativos que no permiten la correcta aplicación de buenas prácticas de gobernanza de TI en éstas empresas. Los resultados encontrados llevaron a la construcción de un marco de gobernanza de TI con foco en PyMEs, a la definición de un modelo de madurez asociado al marco y a una guía de implantación. En el marco de gobernanza propuesto, compatible con el estándar ISO/IEC 38500:2008, se han fortalecido los procesos que, por las características propias de las PyMEs presentan debilidades estructurales y se han reducido o eliminado aquellos que por las mismas razones no son aplicables a este tipo de organización. Finalmente se validaron los resultados en un entorno empresarial definiendo un estudio de caso. Los resultados obtenidos con una mejora porcentual consolidada del 46% en el conjunto de indicadores definidos llevan a considerar que la aplicación del marco fue exitosa. Por ser un estudio de caso único, los resultados no deben ser generalizados y una oportunidad de trabajo futuro es replicar el mismo estudio en otras empresas. ABSTRACT Information technology (IT) and its use in the enterprise context is a discussion element because organizations have numerous successes and failures using it. Most of the IT failed projects have a lack of integral strategic vision in relation with IT use in the organization. This fact has resulted in the IT Governance (ITG) area of knowledge. A large number of standards and frameworks have been published in relation with it. Small and medium enterprises (SMEs) are an important and sensible field in all economies around the world, particularly in Uruguay, an underdeveloped country of South America. Commonly, SMEs cannot apply successfully ITG frameworks because of the intrinsic complexity or because a lack of knowledge and culture respect this field, so the objective of this thesis is build a framework that allows SMEs to incorporate an effective framework to govern and manage IT properly, helping enterprises get the expected value of its IT investments. In a first place, has been conducted a field study to know the quality of actual practices relatively to the ITG and IG management in Uruguayan SMEs. With the obtained results in the study we can make a diagnostic of the most significant factors that prevent the proper application of good IT governance practices in these companies. The obtained results were the inputs to the definition of a IT governance framework with focus in SMEs, a maturity model associated with it and a implementation guide. The proposed framework is ISO/IEC 38500 standard compatible always with an SME vision so, sensible and weak processes have been strengthened and other ones have been eliminated because have no application in these type of organization. Finally the results were validated in a business environment by defining a case study. The results obtained with a consolidated percentage improvement of 46% in the defined set of indicators suggest that the implementation of the framework was successful. As a single case study, the results should not be generalized and an opportunity for future work is to replicate the same study in other companies.
Resumo:
Este proyecto está dividido en dos partes, una de ellas dedicada al estudio del sistema de adquisición NetdB y su aplicación a prácticas de Acústica Arquitectónica y la otra dedicada a la evaluación de la herramienta OneNote 2010 y su aplicación al proceso enseñanza – aprendizaje. Se estructura en cinco secciones bien definidas que se comentan a continuación: La primera sección, fundamentos teóricos, se centrará en explicar los distintos parámetros medidos y su relación con la acústica. Para ello se definirán los conceptos teóricos básicos que ayudarán al seguimiento del proyecto en su totalidad. La segunda sección está dedicada al sistema de adquisición NetdB, y en ella se explican sus características, el conexionado del equipo y la configuración del mismo con el software dBBati. En la tercera sección se describen las medidas realizadas con el sistema de adquisición NetdB, basadas en la normativa nacional e internacional vigente. Estas medidas son: - Medición del tiempo de reverberación en recintos ordinarios, según la Norma UNE-EN ISO 3382-2. - Medición del coeficiente de absorción sonora en cámara reverberante, según la Norma UNE-EN ISO 354. - Medición “in situ” del aislamiento a ruido aéreo, según las normas UNE-EN ISO 140-4 y UNE-EN ISO 717-1. En cada una de las medidas se describe el objetivo, los equipos utilizados, la conexión entre los distintos equipos, el ensayo realizado según la norma correspondiente, los cálculos y resultados obtenidos y las conclusiones finales de la medida. En la cuarta sección se describe la herramienta OneNote 2010, detallándose su estructura, configuración y la evaluación de su aplicación al proceso enseñanza – aprendizaje. Por último, se darán unas conclusiones finales, en las que se recapitularán los resultados de las valoraciones obtenidos durante la realización del proyecto. ABSTRACT. This project is divided into two parts, one of them dealing with the study of NetdB acquisition system and its application on Architectural Acoustics practices and the other dedicated to the evaluation of the OneNote 2010 tool and its application on the teaching-learning process. The structure of the project consists of five clearly defined sections as stated hereunder: 1. Theoretical fundamentals, based on the explanation of the different parameters subject to measurement and their relation to acoustics. To this end, basic theoretical concepts will be clearly defined, which will help the follow-up of the project as a whole. 2. NetdB acquisition system: whereby features will be clearly defined, as well as the equipment connection and its configuration within the dBBati software. 3. Description of the measures carried out on the NetdB acquisition system under current regulations both national and international, being those measures as follows: - Reverberation Time measurement in ordinary premises, according to the UNE-EN ISO 3382-2 standard. - Sound absorption ratio measurement in reverberating chamber, according to the UNE-EN ISO 354 standard. - “In situ” sound proofing air traffic, according to UNE-EN ISO 140-4 and UNE-EN ISO 717-1 standards. Each of the measures stated above comprises the description of the following issues: its aim, the equipment in use, the connection among different equipment, the test carried out under the corresponding standard, the calculations and results obtained and finally the conclusions reached at. 4. OneNote 2010 tool: full description detailing its structure, configuration as well as the evaluation of its application on the teaching-learning process. Finally, the report will give the final conclusions by means of recapitulating the results of the different assessments obtained along the process.
Resumo:
La protección de las aguas subterráneas es una prioridad de la política medioambiental de la UE. Por ello ha establecido un marco de prevención y control de la contaminación, que incluye provisiones para evaluar el estado químico de las aguas y reducir la presencia de contaminantes en ellas. Las herramientas fundamentales para el desarrollo de dichas políticas son la Directiva Marco del Agua y la Directiva Hija de Aguas Subterráneas. Según ellas, las aguas se consideran en buen estado químico si: • la concentración medida o prevista de nitratos no supera los 50 mg/l y la de ingredientes activos de plaguicidas, de sus metabolitos y de los productos de reacción no supera el 0,1 μg/l (0,5 μg/l para el total de los plaguicidas medidos) • la concentración de determinadas sustancias de riesgo es inferior al valor umbral fijado por los Estados miembros; se trata, como mínimo, del amonio, arsénico, cadmio, cloruro, plomo, mercurio, sulfatos, tricloroetileno y tetracloroetileno • la concentración de cualquier otro contaminante se ajusta a la definición de buen estado químico enunciada en el anexo V de la Directiva marco sobre la política de aguas • en caso de superarse el valor correspondiente a una norma de calidad o a un valor umbral, una investigación confirma, entre otros puntos, la falta de riesgo significativo para el medio ambiente. Analizar el comportamiento estadístico de los datos procedentes de la red de seguimiento y control puede resultar considerablemente complejo, debido al sesgo positivo que suelen presentar dichos datos y a su distribución asimétrica, debido a la existencia de valores anómalos y diferentes tipos de suelos y mezclas de contaminantes. Además, la distribución de determinados componentes en el agua subterránea puede presentar concentraciones por debajo del límite de detección o no ser estacionaria debida a la existencia de tendencias lineales o estacionales. En el primer caso es necesario realizar estimaciones de esos valores desconocidos, mediante procedimientos que varían en función del porcentaje de valores por debajo del límite de detección y el número de límites de detección aplicables. En el segundo caso es necesario eliminar las tendencias de forma previa a la realización de contrastes de hipótesis sobre los residuos. Con esta tesis se ha pretendido establecer las bases estadísticas para el análisis riguroso de los datos de las redes de calidad con objeto de realizar la evaluación del estado químico de las masas de agua subterránea para la determinación de tendencias al aumento en la concentración de contaminantes y para la detección de empeoramientos significativos, tanto en los casos que se ha fijado un estándar de calidad por el organismo medioambiental competente como en aquéllos que no ha sido así. Para diseñar una metodología que permita contemplar la variedad de casos existentes, se han analizado los datos de la Red Oficial de Seguimiento y Control del Estado Químico de las Aguas Subterráneas del Ministerio de Agricultura, Alimentación y Medio Ambiente (Magrama). A continuación, y dado que los Planes Hidrológicos de Cuenca son la herramienta básica de las Directivas, se ha seleccionado la Cuenca del Júcar, dada su designación como cuenca piloto en la estrategia de implementación común (CIS) de la Comisión Europea. El objetivo principal de los grupos de trabajo creados para ello se dirigió a implementar la Directiva Derivada de Agua Subterráneas y los elementos de la Directiva Marco del Agua relacionadas, en especial la toma de datos en los puntos de control y la preparación del primer Plan de Gestión de Cuencas Hidrográficas. Dada la extensión de la zona y con objeto de analizar una masa de agua subterránea (definida como la unidad de gestión en las Directivas), se ha seleccionado una zona piloto (Plana de Vinaroz Peñiscola) en la que se han aplicado los procedimientos desarrollados con objeto de determinar el estado químico de dicha masa. Los datos examinados no contienen en general valores de concentración de contaminantes asociados a fuentes puntuales, por lo que para la realización del estudio se han seleccionado valores de concentración de los datos más comunes, es decir, nitratos y cloruros. La estrategia diseñada combina el análisis de tendencias con la elaboración de intervalos de confianza cuando existe un estándar de calidad e intervalos de predicción cuando no existe o se ha superado dicho estándar. De forma análoga se ha procedido en el caso de los valores por debajo del límite de detección, tomando los valores disponibles en la zona piloto de la Plana de Sagunto y simulando diferentes grados de censura con objeto de comparar los resultados obtenidos con los intervalos producidos de los datos reales y verificar de esta forma la eficacia del método. El resultado final es una metodología general que integra los casos existentes y permite definir el estado químico de una masa de agua subterránea, verificar la existencia de impactos significativos en la calidad del agua subterránea y evaluar la efectividad de los planes de medidas adoptados en el marco del Plan Hidrológico de Cuenca. ABSTRACT Groundwater protection is a priority of the EU environmental policy. As a result, it has established a framework for prevention and control of pollution, which includes provisions for assessing the chemical status of waters and reducing the presence of contaminants in it. The measures include: • criteria for assessing the chemical status of groundwater bodies • criteria for identifying significant upward trends and sustained concentrations of contaminants and define starting points for reversal of such trends • preventing and limiting indirect discharges of pollutants as a result of percolation through soil or subsoil. The basic tools for the development of such policies are the Water Framework Directive and Groundwater Daughter Directive. According to them, the groundwater bodies are considered in good status if: • measured or predicted concentration of nitrate does not exceed 50 mg / l and the active ingredients of pesticides, their metabolites and reaction products do not exceed 0.1 mg / l (0.5 mg / l for total of pesticides measured) • the concentration of certain hazardous substances is below the threshold set by the Member States concerned, at least, of ammonium, arsenic, cadmium, chloride, lead, mercury, sulphates, trichloroethylene and tetrachlorethylene • the concentration of other contaminants fits the definition of good chemical status set out in Annex V of the Framework Directive on water policy • If the value corresponding to a quality standard or a threshold value is exceeded, an investigation confirms, among other things, the lack of significant risk to the environment. Analyzing the statistical behaviour of the data from the monitoring networks may be considerably complex due to the positive bias which often presents such information and its asymmetrical distribution, due to the existence of outliers and different soil types and mixtures of pollutants. Furthermore, the distribution of certain components in groundwater may have concentrations below the detection limit or may not be stationary due to the existence of linear or seasonal trends. In the first case it is necessary to estimate these unknown values, through procedures that vary according to the percentage of values below the limit of detection and the number of applicable limits of detection. In the second case removing trends is needed before conducting hypothesis tests on residuals. This PhD thesis has intended to establish the statistical basis for the rigorous analysis of data quality networks in order to conduct the evaluation of the chemical status of groundwater bodies for determining upward and sustained trends in pollutant concentrations and for the detection of significant deterioration in cases in which an environmental standard has been set by the relevant environmental agency and those that have not. Aiming to design a comprehensive methodology to include the whole range of cases, data from the Groundwater Official Monitoring and Control Network of the Ministry of Agriculture, Food and Environment (Magrama) have been analysed. Then, since River Basin Management Plans are the basic tool of the Directives, the Júcar river Basin has been selected. The main reason is its designation as a pilot basin in the common implementation strategy (CIS) of the European Commission. The main objective of the ad hoc working groups is to implement the Daughter Ground Water Directive and elements of the Water Framework Directive related to groundwater, especially the data collection at control stations and the preparation of the first River Basin Management Plan. Given the size of the area and in order to analyze a groundwater body (defined as the management unit in the Directives), Plana de Vinaroz Peñíscola has been selected as pilot area. Procedures developed to determine the chemical status of that body have been then applied. The data examined do not generally contain pollutant concentration values associated with point sources, so for the study concentration values of the most common data, i.e., nitrates and chlorides have been selected. The designed strategy combines trend analysis with the development of confidence intervals when there is a standard of quality and prediction intervals when there is not or the standard has been exceeded. Similarly we have proceeded in the case of values below the detection limit, taking the available values in Plana de Sagunto pilot area and simulating different degrees of censoring in order to compare the results obtained with the intervals achieved from the actual data and verify in this way the effectiveness of the method. The end result is a general methodology that integrates existing cases to define the chemical status of a groundwater body, verify the existence of significant impacts on groundwater quality and evaluate the effectiveness of the action plans adopted in the framework of the River Basin Management Plan.
Resumo:
All activities of an organization involve risks that should be managed. The risk management process aids decision making by taking account of uncertainty and the possibility of future events or circumstances (intended or unintended) and their effects on agreed objectives. With that idea, new ISO Standard has been drawn up. ISO 31010 has been recently issued which provides a structured process that identifies how objectives may be affected, and analyses the risk in term of consequences and their probabilities before deciding on whether further treatment is required. In this lecture, that ISO Standard has been adapted to Open Pit Blasting Operations, focusing in Environmental effects which can be managed properly. Technique used is Fault Tree Analysis (FTA), which is applied in all possible scenarios, providing to Blasting Professionals the tools to identify, analyze and manage environmental effects in blasting operations. Also this lecture can help to minimize each effect, studying each case. This paper also can be useful to Project Managers and Occupational Health and Safety Departments (OH&S) because blasting operations can be evaluated and compared one to each other to determine the risks that should be managed in different case studies. The environmental effects studied are: ground vibrations, flyrock and air overpressure (airblast). Sometimes, blasting operations are carried out near populated areas where environmental effects may impose several limitations on the use of explosives. In those cases, where these factors approach certain limits, National Standards and Regulations have to be applied.
Resumo:
The increasing importance of pollutant noise has led to the creation of many new noise testing laboratories in recent years. For this reason and due to the legal implications that noise reporting may have, it is necessary to create procedures intended to guarantee the quality of the testing and its results. For instance, the ISO/IEC standard 17025:2005 specifies general requirements for the competence of testing laboratories. In this standard, interlaboratory comparisons are one of the main measures that must be applied to guarantee the quality of laboratories when applying specific methodologies for testing. In the specific case of environmental noise, round robin tests are usually difficult to design, as it is difficult to find scenarios that can be available and controlled while the participants carry out the measurements. Monitoring and controlling the factors that can influence the measurements (source emissions, propagation, background noise…) is not usually affordable, so the most extended solution is to create very effortless scenarios, where most of the factors that can have an influence on the results are excluded (sampling, processing of results, background noise, source detection…) The new approach described in this paper only requires the organizer to make actual measurements (or prepare virtual ones). Applying and interpreting a common reference document (standard, regulation…), the participants must analyze these input data independently to provide the results, which will be compared among the participants. The measurement costs are severely reduced for the participants, there is no need to monitor the scenario conditions, and almost any relevant factor can be included in this methodology
Resumo:
Knowledge of the uncertainty of measurement of testing results is important when results have to be compared with limits and specifications. In the measurement of sound insulation following standards UNE EN ISO 140-4 the uncertainty of the final magnitude is mainly associated to the average sound pressure levels L1 and L2 measured. A parameter that allows us to quantify the spatial variation of the sound pressure level is the standard deviation of the pressure levels measured at different points of the room. In this work, for a wide number of measurements following standards UNE EN ISO 140-4 we analyzed qualitatively the behaviour of the standard deviation for L1 and L2. The study of sound fields in enclosed spaces is very difficult. There are a wide variety of rooms with different sound fields depending on factors as volume, geometry and materials. In general, we observe that the L1 and L2 standard deviations contain peaks and dips independent on characteristics of the rooms at single frequencies that could correspond to critical frequencies of walls, floors and windows or even to temporal alterations of the sound field. Also, in most measurements according to UNE EN ISO 140-4 a large similitude between L1 and L2 standard deviation is found. We believe that such result points to a coupled system between source and receiving rooms, mainly at low frequencies the shape of the L1 and L2 standard deviations is comparable to the velocity level standard deviation on a wall
Resumo:
Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.
Resumo:
En los ensayos de aislamiento acústico según normas UNE EN ISO 140-4 y 140-5 el valor de L2 es un promedio espacio-temporal de los niveles de presión sonora medidos en diferentes posiciones de la sala receptora. La desviación estándar de estos valores se puede considerar como una medida de la uniformidad del campo sonoro en el recinto. Se analiza este parámetro en función de la frecuencia y se propone un cálculo teórico del mismo como una incertidumbre combinada de la desviación estándar derivada de modelos teóricos centrados en la geometría del recinto y la desviación estándar asociada a la vibración de la pared separadora
Resumo:
Abstract interpretation-based data-flow analysis of logic programs is, at this point, relatively well understood from the point of view of general frameworks and abstract domains. On the other hand, comparatively little attention has been given to the problems which arise when analysis of a full, practical dialect of the Prolog language is attempted, and only few solutions to these problems have been proposed to date. Existing proposals generally restrict in one way or another the classes of programs which can be analyzed. This paper attempts to fill this gap by considering a full dialect of Prolog, essentially the recent ISO standard, pointing out the problems that may arise in the analysis of such a dialect, and proposing a combination of known and novel solutions that together allow the correct analysis of arbitrary programs which use the full power of the language.
Resumo:
El apartado <4.2 Altavoz> de la Norma Internacional UNE-EN ISO 140-5
Resumo:
La hipótesis de esta tesis es: "La optimización de la ventana considerando simultáneamente aspectos energéticos y aspectos relativos a la calidad ambiental interior (confort higrotérmico, lumínico y acústico) es compatible, siempre que se conozcan y consideren las sinergias existentes entre ellos desde las primeras fases de diseño". En la actualidad se desconocen las implicaciones de muchas de las decisiones tomadas en torno a la ventana; para que su eficiencia en relación a todos los aspectos mencionados pueda hacerse efectiva es necesaria una herramienta que aporte más información de la actualmente disponible en el proceso de diseño, permitiendo así la optimización integral, en función de las circunstancias específicas de cada proyecto. En la fase inicial de esta investigación se realiza un primer acercamiento al tema, a través del estado del arte de la ventana; analizando la normativa existente, los componentes, las prestaciones, los elementos experimentales y la investigación. Se observa que, en ocasiones, altos requisitos de eficiencia energética pueden suponer una disminución de las prestaciones del sistema en relación con la calidad ambiental interior, por lo que surge el interés por integrar al análisis energético aspectos relativos a la calidad ambiental interior, como son las prestaciones lumínicas y acústicas y la renovación de aire. En este punto se detecta la necesidad de realizar un estudio integral que incorpore los distintos aspectos y evaluar las sinergias que se dan entre las distintas prestaciones que cumple la ventana. Además, del análisis de las soluciones innovadoras y experimentales se observa la dificultad de determinar en qué medida dichas soluciones son eficientes, ya que son soluciones complejas, no caracterizadas y que no están incorporadas en las metodologías de cálculo o en las bases de datos de los programas de simulación. Por lo tanto, se plantea una segunda necesidad, generar una metodología experimental para llevar a cabo la caracterización y el análisis de la eficiencia de sistemas innovadores. Para abordar esta doble necesidad se plantea la optimización mediante una evaluación del elemento acristalado que integre la eficiencia energética y la calidad ambiental interior, combinando la investigación teórica y la investigación experimental. En el ámbito teórico, se realizan simulaciones, cálculos y recopilación de información de distintas tipologías de hueco, en relación con cada prestación de forma independiente (acústica, iluminación, ventilación). A pesar de haber partido con un enfoque integrador, resulta difícil esa integración detectándose una carencia de herramientas disponible. En el ámbito experimental se desarrolla una metodología para la evaluación del rendimiento y de aspectos ambientales de aplicación a elementos innovadores de difícil valoración mediante la metodología teórica. Esta evaluación consiste en el análisis comparativo experimental entre el elemento innovador y un elemento estándar; para llevar a cabo este análisis se han diseñado dos espacios iguales, que denominamos módulos de experimentación, en los que se han incorporado los dos sistemas; estos espacios se han monitorizado, obteniéndose datos de consumo, temperatura, iluminancia y humedad relativa. Se ha realizado una medición durante un periodo de nueve meses y se han analizado y comparado los resultados, obteniendo así el comportamiento real del sistema. Tras el análisis teórico y el experimental, y como consecuencia de esa necesidad de integrar el conocimiento existente se propone una herramienta de evaluación integral del elemento acristalado. El desarrollo de esta herramienta se realiza en base al procedimiento de diagnóstico de calidad ambiental interior (CAI) de acuerdo con la norma UNE 171330 “Calidad ambiental en interiores”, incorporando el factor de eficiencia energética. De la primera parte del proceso, la parte teórica y el estado del arte, se obtendrán los parámetros que son determinantes y los valores de referencia de dichos parámetros. En base a los parámetros relevantes obtenidos se da forma a la herramienta, que consiste en un indicador de producto para ventanas que integra todos los factores analizados y que se desarrolla según la Norma UNE 21929 “Sostenibilidad en construcción de edificios. Indicadores de sostenibilidad”. ABSTRACT The hypothesis of this thesis is: "The optimization of windows considering energy and indoor environmental quality issues simultaneously (hydrothermal comfort, lighting comfort, and acoustic comfort) is compatible, provided that the synergies between these issues are known and considered from the early stages of design ". The implications of many of the decisions made on this item are currently unclear. So that savings can be made, an effective tool is needed to provide more information during the design process than the currently available, thus enabling optimization of the system according to the specific circumstances of each project. The initial phase deals with the study from an energy efficiency point of view, performing a qualitative and quantitative analysis of commercial, innovative and experimental windows. It is observed that sometimes, high-energy efficiency requirements may mean a reduction in the system's performance in relation to user comfort and health, that's why there is an interest in performing an integrated analysis of indoor environment aspects and energy efficiency. At this point a need for a comprehensive study incorporating the different aspects is detected, to evaluate the synergies that exist between the various benefits that meet the window. Moreover, from the analysis of experimental and innovative windows, a difficulty in establishing to what extent these solutions are efficient is observed; therefore, there is a need to generate a methodology for performing the analysis of the efficiency of the systems. Therefore, a second need arises, to generate an experimental methodology to perform characterization and analysis of the efficiency of innovative systems. To address this dual need, the optimization of windows by an integrated evaluation arises, considering energy efficiency and indoor environmental quality, combining theoretical and experimental research. In the theoretical field, simulations and calculations are performed; also information about the different aspects of indoor environment (acoustics, lighting, ventilation) is gathered independently. Despite having started with an integrative approach, this integration is difficult detecting lack available tools. In the experimental field, a methodology for evaluating energy efficiency and indoor environment quality is developed, to be implemented in innovative elements which are difficult to evaluate using a theoretical methodology This evaluation is an experimental comparative analysis between an innovative element and a standard element. To carry out this analysis, two equal spaces, called experimental cells, have been designed. These cells have been monitored, obtaining consumption, temperature, luminance and relative humidity data. Measurement has been performed during nine months and results have been analyzed and compared, obtaining results of actual system behavior. To advance this optimization, windows have been studied from the point of view of energy performance and performance in relation to user comfort and health: thermal comfort, acoustic comfort, lighting comfort and air quality; proposing the development of a methodology for an integrated analysis including energy efficiency and indoor environment quality. After theoretical and experimental analysis and as a result of the need to integrate existing knowledge, a comprehensive evaluation procedure for windows is proposed. This evaluation procedure is developed according to the UNE 171330 "Indoor Environmental Quality", also incorporating energy efficiency and cost as factors to evaluate. From the first part of the research process, outstanding parameters are chosen and reference values of these parameters are set. Finally, based on the parameters obtained, an indicator is proposed as windows product indicator. The indicator integrates all factors analyzed and is developed according to ISO 21929-1:2011"Sustainability in building construction. Sustainability indicators. Part 1: Framework for the development of indicators and a core set of indicators for buildings".