12 resultados para Hot modulus of rupture test

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study includes an analysis of the applicability of current models used for estimating the mechanical properties of conventional concrete to self-compacting concrete. The mechanical properties evaluated are: modulus of elasticity, tensile strength, and modulus of rupture. An extensive database which included the dosifications and the mechanical properties of 627 mixtures from 138 different references, was used. The models considered are: ACI, EC-2, NZS 3101:2006 (New Zealand code) and the CSA A23.3-04 (Canadian code). The precision in estimating the modulus of elasticity and tensile strength is acceptable for all models; however, all models are less precise in estimating the modulus of rupture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Se han clasificado visualmente, según la norma española UNE 56544; 150 piezas de madera aserrada de pino radiata procedentes de Cataluña (España) con una sección de 80x150 mm y una longitud de 2.500 mm. Esta norma establece dos calidades visuales (ME-1 y ME-2) para piezas con grueso menor o igual que 70 mm y una única calidad visual (MEG) para gruesos mayores de 70 mm. Con el fin de conocer el efecto frontera entre la pequeña y la gran escuadría se clasificaron las piezas según ambas categorías. Se determinó la tensión de rotura en flexión, el módulo de elasticidad en flexión y la densidad de cada pieza mediante el ensayo de acuerdo con la norma UNE-EN 408 siguiendo los ajustes definidos en la norma UNE-EN 384. Un 53 % de las piezas se clasificaron como MEG con una resistencia característica a flexión de 28 N/mm2 y un valor medio del módulo de elasticidad de 9.900 N/mm2. Por otra, un 42 % de las piezas se clasificaron como ME-2 y sólo un 3 % como ME-1; en este caso las propiedades mecánicas de la calidad ME-2 no se alejan mucho de las de la calidad MEG. El elevado porcentaje de piezas rechazadas (47 % frente a la MEG) se debe principalmente al defecto de alabeo responsable de un 39 % de rechazo. Si no se considera el alabeo en la clasificación el porcentaje de rechazo desciende al 17 % y las propiedades mecánicas de la calidad MEG presentan un valor característico de resistencia a flexión de 21 N/mm2 y un módulo de elasticidad de 9.100 N/mm2. A sample of 150 pieces of radiata pine sawn timber with 180x120 mm in cross-section and 2.500 mm in length sourcing from Catalonia (Spain) were visually graded according to Spanish standard UNE 56544. This standard establish two visual grades (ME-1 and ME-2) for timber pieces with thickness equal or less than 70 mm, and one grade (MEG) for thickness bigger than 70 mm. In order to know the border effect between small and larger cross-section the pieces were graded in both categories. The modulus of rupture, modulus of elasticity and density were obtained by test according to EN 408 standard and the adjustments of EN 384. A 53 % of pieces were classified as MEG with a characteristic bending strength of 28 N/mm2 and a mean value of MOE of 9.900 N/mm2. On the other hand, a 42 % of pieces were classified as ME-2 and only a 3 % as ME-1; in this case the mechanical properties of ME-2 are not far from MEG properties. The high percentage of rejected pieces (47 % vs MEG) is mainly due to the twist defect with a 39 % of rejected pieces. If twist is not considered in the grading process the reject percentage decreases to 17 % and the mechanical properties of MEG grade present a characteristic value of bending strength of 21 N/mm2 and a MOE of 9.100 N/mm2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to analyze the applicability of current models used for estimating the mechanical properties of conventional concrete to self-consolidating concrete (SCC). The mechanical properties evaluated are modulus of elasticity, tensile strength,and modulus of rupture. As part of the study, it was necessary to build an extensive database that included the proportions and mechanical properties of 627 mixtures from 138 different references. The same models that are currently used for calculating the mechanical properties of conventional concrete were applied to SCC to evaluate their applicability to this type of concrete. The models considered are the ACI 318, ACI 363R, and EC2. These are the most commonly used models worldwide. In the first part of the study, the overall behavior and adaptability of the different models to SCC is evaluated. The specific characterization parameters for each concrete mixture are used to calculate the various mechanical properties applying the different estimation models. The second part of the analysis consists of comparing the experimental results of all the mixtures included in the database with the estimated results to evaluate the applicability of these models to SCC. Various statistical procedures, such as regression analysis and residual analysis, are used to compare the predicted and measured properties. It terms of general applicability, the evaluated models are suitable for estimating the modulus of elasticity, tensile strength, and modulus of rupture of SCC. These models have a rather low sensitivity, however, and adjust well only to mean values. This is because the models use the compressive strength as the main variable to characterize the concrete and do not consider other variables that affect these properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In accordance with Russian, Kazakh and European building regulations, the deformation modulus of soil should be determined in the laboratory and also apply in situ soil tests on the stages of engineering geology prospecting. In this paper we present data on the determination and adjustment of the deformation characteristics at different stages of construction

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A methodology is presented to measure the fiber/matrix interface shear strength in composites. The strategy is based on performing a fiber push-in test at the central fiber of highly-packed fiber clusters with hexagonal symmetry which are often found in unidirectional composites with a high volume fraction of fibers. The mechanics of this test was analyzed in detail by means of three-dimensional finite element simulations. In particular, the influence of different parameters (interface shear strength, toughness and friction as well as fiber longitudinal elastic modulus and curing stresses) on the critical load at the onset of debonding was established. From the results of the numerical simulations, a simple relationship between the critical load and the interface shear strength is proposed. The methodology was validated in an unidirectional C/epoxy composite and the advantages and limitations of the proposed methodology are indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El principal objetivo de este estudio es evaluar la influencia de las fendas de secado en las propiedades mecánicas de vigas de madera. Para esto, se utilizan 40 vigas de Pino silvestre (Pinus sylvestris L) de 4200 mm de longitud y 150x200 mm de sección que fueron ensayadas según norma EN 408. Las fendas se registran detalladamente atendiendo a su longitud y posición en cada cara de la viga, y midiendo el espesor y la profundidad cada 100mm a lo largo de la viga. Solo el 10% de la muestra es rechazada por las fendas, según los criterios establecidos por la norma española de clasificación visual UNE 56544. Para evaluar la influencia de las fendas en las propiedades mecánicas, se usan tres parámetros globales basados en el área, el volumen o la profundad de la fenda, y dos locales basados en la profundidad máxima y la profundidad en la zona de rotura. Además se determina la densidad de las piezas. Estos parámetros se comparan con las propiedades mecánicas (tensión de rotura, módulo de elasticidad y energía de rotura) y se encuentra escasa relación entre ellos. Las mejores correlaciones se encuentran entre los parámetros relacionados con la profundidad de las fendas, tanto con el módulo de elasticidad como con la tensión de rotura. The aim of this study is the evaluation of the influence of drying fissures on the mechanical properties of timber beams. For that purpose, 40 sawn timber pieces of Scots pine (Pinus sylvestris L.) with 150x200 mm in cross-section and 4200 mm in length have been tested according to EN 408, obtaining MOR and MOE. The fissures were registered in detail measuring their length and position in each face of the beam, and the thickness and depth every 100 mm in length. Only 10 % of the pieces were rejected because fissures, according to UNE 56544 Spanish visual grading standard. To evaluate the influence of fissures in mechanical properties three global parameters: Fissures Area Ratio or ratio between the area occupied by fissures and the total area in the neutral axis plane of the beam; Fissures Volume Ratio or ratio between volume of fissures and the total volume of the beam; Fissures Average Depth and two local parameters were used: Fissures Maximum Depth in the beam, and Fissures Depth in the broken zone of the beam. Also the density of the beams was registered. These parameters were compared with mechanical properties (tensile strength, elasticity modulus, and rupture energy) and the relationship between them had not been founded. The best relationship was founded between the elasticity modulus y the tensile strength with the parameters which included the depth of the fissures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many efforts have been made in order to adequate the production of a solar thermal collector field to the consumption of domestic hot water of the inhabitants of a building. In that sense, much has been achieved in different domains: research agencies, government policies and manufacturers. However, most of the design rules of the solar plants are based on steady state models, whereas solar irradiance, consumption and thermal accumulation are inherently transient processes. As a result of this lack of physical accuracy, thermal storage tanks are sometimes left to be as large as the designer decides without any aforementioned precise recommendation. This can be a problem if solar thermal systems are meant to be implemented in nowadays buildings, where there is a shortage of space. In addition to that, an excessive storage volume could not result more efficient in many residential applications, but costly, extreme in space consumption and in some cases too heavy. A proprietary transient simulation program has been developed and validated with a detailed measurement campaign in an experimental facility. In situ environmental data have been obtained through a whole year of operation. They have been gathered at intervals of 10 min for a solar plant of 50 m2 with a storage tank of 3 m3, including the equipment for domestic hot water production of a typical apartment building. This program has been used to obtain the design and dimensioning criteria of DHW solar plants under daily transient conditions throughout a year and more specifically the size of the storage tank for a multi storey apartment building. Comparison of the simulation results with the current Spanish regulation applicable, “Código Técnico de la Edificación” (CTE 2006), offers fruitful details and establishes solar facilities dimensioning criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pressuremeter test in boreholes has proven itself as a useful tool in geotechnical explorations, especially comparing its results with those obtained from a mathematical model ruled by a soil representative constitutive equation. The numerical model shown in this paper is aimed to be the reference framework for the interpretation of this test. The model analyses variables such as: the type of response, the initial state, the drainage regime and the constitutive equations. It is a model of finite elements able to work with a mesh without deformation or one adapted to it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerical simulations of axisymmetric reactive jets with one-step Arrhenius kinetics are used to investigate the problem of deflagration initiation in a premixed fuel–air mixture by the sudden discharge of a hot jet of its adiabatic reaction products. For the moderately large values of the jet Reynolds number considered in the computations, chemical reaction is seen to occur initially in the thin mixing layer that separates the hot products from the cold reactants. This mixing layer is wrapped around by the starting vortex, thereby enhancing mixing at the jet head, which is followed by an annular mixing layer that trails behind, connecting the leading vortex with the orifice rim. A successful deflagration is seen to develop for values of the orifice radius larger than a critical value a c in the order of the flame thickness of the planar deflagration δL. Introduction of appropriate scales provides the dimensionless formulation of the problem, with flame initiation characterised in terms of a critical Damköhler number Δc=(a d/δL)2, whose parametric dependence is investigated. The numerical computations reveal that, while the jet Reynolds number exerts a limited influence on the criticality conditions, the effect of the reactant diffusivity on ignition is much more pronounced, with the value of Δc increasing significantly with increasing Lewis numbers. The reactant diffusivity affects also the way ignition takes place, so that for reactants with the flame develops as a result of ignition in the annular mixing layer surrounding the developing jet stem, whereas for highly diffusive reactants with Lewis numbers sufficiently smaller than unity combustion is initiated in the mixed core formed around the starting vortex. The analysis provides increased understanding of deflagration initiation processes, including the effects of differential diffusion, and points to the need for further investigations corporating detailed chemistry models for specific fuel–air mixtures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study addresses deflagration initiation of lean and stoichiometric hydrogen–air mixtures by the sudden discharge of a hot jet of their adiabatic combustion products. The objective is to compute the minimum jet radius required for ignition, a relevant quantity of interest for safety and technological applications. For sufficiently small discharge velocities, the numerical solution of the problem requires integration of the axisymmetric Navier–Stokes equations for chemically reacting ideal-gas mixtures, supplemented by standard descriptions of the molecular transport terms and a suitably reduced chemical-kinetic mechanism for the chemistry description. The computations provide the variation of the critical radius for hot-jet ignition with both the jet velocity and the equivalence ratio of the mixture, giving values that vary between a few tens microns to a few hundred microns in the range of conditions explored. For a given equivalence ratio, the critical radius is found to increase with increasing injection velocities, although the increase is only moderately large. On the other hand, for a given injection velocity, the smallest critical radius is found at stoichiometric conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite its ornamental value, some Melocactus species (Cactaceae) are threatened by several factors and only sexual propagation is possible. Thus, artificial seed banks are an appropriate method for their ex situ conservation. Suitable methods to germinate and to monitor viability are necessary for the seeds of these species. This work explored the use of tetrazolium test for monitoring seed viability of two Melocactus species. There was a correlation between the percentage of stained embryos, considering different cover area or tone stain, and the germination percentage. Unviable embryos did not stain. The embryos curved shape can explain the partial stain on the most of cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was designed to determine the effect of temperature on the mechanical strength (in both in vivo and post-exposure trials) of two alkaline cements (without OPC): (a) 100% fly ash (FA) and (b) 85% FA + 15% bauxite, the activated alkaline solution used was 85% 10-M NaOH + 15% sodium silicate. A Type I 42.5 R Portland cement was used as a control. Two series of trials were conducted: (i) in vivo trials in which bending and compressive strength, fracture toughness and modulus of elasticity were determined at different temperatures; and (ii) post-firing trials, assessing residual bending and compres-sive strength after a 1-h exposure to high temperatures and subsequent cooling. The findings showed that from 25 to 600 C, irrespective of the type of test (in vivo or post-firing), compressive mechanical strength rose, with the specimens exhibiting elastic behaviour and consequently brittle failure. At tem-peratures of over 600 C, behaviour differed depending on the type of test: (i) in the in vivo trials the high temperature induced pseudo-plastic strain and a decline in mechanical strength that did not necessarily entail specimen failure; (ii) in the post-firing trials, compressive strength rose.