5 resultados para Hemodynamic

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Best percutaneous treatment strategy for lesions in coronary bifurcations is an ongoing subject of debate. There is limited data that analyses the effect of the different bifurcation strategies on coronary flow. Our aim is to evaluate the influence of different bifurcation stenting strategies on hemodynamic parameters, both in the main vessel (MV) and side branch (SB).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The left ventricular (LV) summit is the most common site of idiopathic epicardial LV arrhythmias and frequently represents a diagnostic and a therapeutic challenge.1 We present a case of sustained monomorphic ventricular tachycardia (SMVT) originating at the LV summit that underwent failed cryosurgical epicardial ablation and was successfully treated with the aid of merged hemodynamic and contrast-enhanced MRI (CE-MRI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: Diversos cambios ocurren en el sistema cardiovascular materno durante el embarazo, lo que genera un gran estrés sobre este sistema especialmente durante el tercer trimestre, pudiendo acentuarse en presencia de determinados factores de riesgo. Los objetivos de este estudio fueron, valorar las adaptaciones cardiovasculares producidas por un programa específico de ejercicio físico; su seguridad sobre el sistema cardiovascular materno y los resultados del embarazo; y su eficacia en el control de los factores de riesgo cardiovascular. Material y métodos: El diseño del estudio fue un ensayo clínico aleatorizado. 151 gestantes sanas fueron evaluadas mediante un ecocardiograma y un electrocardiograma en la semana 20 y 34 de gestación. Un total de 89 gestantes participaron en un programa de ejercicio físico (GE) desde el primer hasta el tercer trimestre de embarazo, constituido principalmente por 25-30 minutos de trabajo aeróbico (55-60% de la frecuencia cardiaca de reserva), trabajo de fortalecimiento general y específico, y un trabajo de tonificación del suelo pélvico; desarrollado 3 días a la semana con una duración de 55-60 minutos cada sesión. Las gestantes aleatoriamente asignadas al grupo de control (GC; n=62) permanecieron sedentarias durante el embarazo. El estudio fue aprobado por el Comité Ético de investigación clínica del Hospital Universitario de Fuenlabrada. Resultados: Las características basales fueron similares entre ambos grupos. A diferencia del GC, las gestantes del GE evitaron el descenso significativo del gasto cardiaco indexado, entre el 2º y 3ºT de embarazo, y conservaron el patrón geométrico normal del ventrículo izquierdo; mientras que en el GC cambió hacia un patrón de remodelado concéntrico. En la semana 20, las gestantes del GE presentaron valores significativamente menores de frecuencia cardiaca (GC: 79,56±10,76 vs. GE: 76,05±9,34; p=0,04), tensión arterial sistólica (GC: 110,19±10,23 vs. GE: 106,04±12,06; p=0,03); tensión arterial diastólica (GC: 64,56±7,88 vs. GE: 61,81±7,15; p=0,03); tiempo de relajación isovolumétrica (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); y un mayor tiempo de deceleración de la onda E (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). En la semana 34, el GE presentó valores significativamente superiores de volumen sistólico (GC: 51,13±11,85 vs. GE: 56,21±12,79 p=0,04), de llenado temprano del ventrículo izquierdo (E) (GC: 78,38±14,07 vs. GE: 85,30±16,62; p=0,02) y de tiempo de deceleración de la onda E (GC: 130,35±37,11 vs. GE: 146,61±43,40; p=0,04). Conclusión: La práctica regular de ejercicio físico durante el embarazo puede producir adaptaciones positivas sobre el sistema cardiovascular materno durante el tercer trimestre de embarazo, además de ayudar en el control de sus factores de riesgo, sin alterar la salud materno-fetal. ABSTRACT Background: Several changes occur in the maternal cardiovascular system during pregnancy. These changes produce a considerable stress in this system, especially during the third trimester, which can be increased in presence of some risk factors. The aims of this study were, to assess the maternal cardiac adaptations in a specific exercise program; its safety on the maternal cardiovascular system and pregnancy outcomes; and its effectiveness in the control of cardiovascular risk factors. Material and methods: A randomized controlled trial was designed. 151 healthy pregnant women were assessed by an echocardiography and electrocardiography at 20 and 34 weeks of gestation. A total of 89 pregnant women participated in a physical exercise program (EG) from the first to the third trimester of pregnancy. It consisted of 25-30 minutes of aerobic conditioning (55-60% of their heart rate reserve), general and specific strength exercises, and a pelvic floor muscles training; 3 times per weeks during 55-60 minutes per session. Pregnant women randomized allocated to the control group (CG) remained sedentary during pregnancy. The study was approved by the Research Ethics Committee of Hospital Universitario de Fuenlabrada. Results: Baseline characteristics were similar between groups. Difference from the CG, pregnant women from the EG prevented the significant decrease of the cardiac output index, between the 2nd and 3rd trimester of pregnancy, and preserved the normal left ventricular pattern; whereas in the CG shifted to concentric remodeling pattern. At 20 weeks, women in the EG had significant lower heart rate (CG: 79,56±10,76 vs. EG: 76,05±9,34; p=0,04), systolic blood pressure (CG: 110,19±10,23 vs. EG: 106,04±12,06; p=0,03); diastolic blood pressure (CG: 64,56±7,88 vs. EG: 61,81±7,15; p=0,03); isovolumetric relaxation time (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); and a higher deceleration time of E Wave (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). At 34 weeks, the EG had a significant higher stroke volume (CG: 51,13±11,85 vs. EG: 56,21±12,79 p=0,04), early filling of left ventricular (E) (CG: 78,38±14,07 vs. EG: 85,30±16,62; p=0,02) and deceleration time of E wave (CG: 130,35±37,11 vs. EG:146,61±43,40; p=0,04). Conclusion: Physical regular exercise program during pregnancy may produce positive maternal cardiovascular adaptations during the third trimester of pregnancy. In addition, it helps to control the cardiovascular risk factors without altering maternal and fetus health.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las enfermedades arteriales vienen presididas por la aterosclerosis, que es un proceso crónico de degeneración, que evoluciona hacia la obstrucción de la luz arterial. La pared de la arteria se engrosa debido al depósito de elementos grasos tales como el colesterol. Los stents intraluminales son diminutas estructuras tubulares autoexpandibles de malla de metal, que se colocan dentro de la arteria coronaria después de una angioplastia con balón para prevenir el cierre de dicha arteria. A pesar de estar diseñados para ser compatibles con el tejido humano, a menudo se da una reacción en cadena de consecuencias indeseables. La reestenosis intra-stent es un problema creciente debido al importante incremento que se ha producido en la utilización del stent intracoronario como forma de revascularización percutánea. Se habla de una incidencia global del 28%, siendo la causa principal de su aparición la proliferación neointimal a través de una compleja cascada de sucesos que pueden tardar meses en desarrollarse. Una de las reacciones más importantes es la trombosis o la formación de una fina capa de coágulo como respuesta a la presencia de un material extraño. Este proceso es multifactorial, y en él intervienen la regresión de la pared como consecuencia del estiramiento previo, la denudación endotelial, lo que permite la agregación plaquetaria, la proliferación neointimal, lo que facilita a los receptores de membrana desencadenar un proceso de agregación posterior y, por último, el remodelado negativo inadecuado de la pared, lo que produce pérdida de luz arterial. Se ha observado frecuentemente que el depósito de ateroma en la pared arterial está relacionado con el valor de los esfuerzos cortantes en la misma. Hay mayores probabilidades de engrosamiento de la pared en las zonas donde son bajos los esfuerzos cortantes, quizá por el mayor tiempo de residencia de las partículas circulantes por el torrente sanguíneo. Si nos centramos en la afirmación anterior, el siguiente paso sería buscar las zonas susceptibles de presentar un valor bajo de dichos esfuerzos. Las zonas potencialmente peligrosas son los codos y bifurcaciones, entre otras. Nos hemos centrado en una bifurcación coronaria, ya que los patrones de flujo que se suelen presentar, tales como recirculación y desprendimiento de vórtices están íntimamente relacionados con las técnicas de implantación de stents en esta zona. Proyectamos nuestros esfuerzos en el estudio de dos técnicas de implante, utilizando un único stent y una tercera a través de una configuración de culotte con el uso de dos stents. El primer caso trata de una bifurcación con un único stent en la rama principal cuyos struts cierran el orificio lateral que da salida a la rama secundaria de la bifurcación, es decir sería un stent sin orificio. El segundo consiste en un único stent también, pero con la diferencia de que éste presenta un orificio de comunicación con la rama lateral. Todas estas técnicas se aplicaron a bifurcaciones de 45º y de 90º. Introdujimos las geometrías -una vez confeccionadas con el código comercial Gambit- en el programa Ansys-Fluent contemplando régimen estacionario. Los resultados obtenidos fueron cotejados con los experimentales, que se realizaron paralelamente, con el fin de corroborarlos. Una vez validados, el estudio computacional ya contó con la fiabilidad suficiente como para abordar el régimen no estacionario, tanto en la versión de reposo como en la de ejercicio –hiperemia- El comportamiento reológico de la sangre para régimen no estacionario en estado de reposo es otra de las tareas abordadas, realizando una comparativa de los modelos Newtoniano, Carreau y Ley de Potencias. Finalmente, en una última etapa, debido a la reciente incursión de los stents diseñados específicamente frente a los convencionales, se aborda el comportamiento hemodinámico de los mismos. Concretamente, se comparó el patrón de flujo en un modelo de bifurcación coronaria con los nuevos stents (Stentys) y los convencionales. Se estudiaron cuatro modelos, a saber, stent simple en la rama principal, stent simple en la rama secundaria, culotte desplegando el primer stent en la rama principal y culotte desplegando el primer stent en la rama secundaria. La bifurcación estudiada presenta un ángulo de apertura de 45º y la relación de diámetros de las ramas hija se ajustaron de acuerdo a la ley de Finet. Se recogieron resultados experimentales en el laboratorio y se corrieron simulaciones numéricas con Ansys Fluent paralelamente. Las magnitudes que se tuvieron en cuenta con el fin de ubicar las regiones potencialmente ateroscleróticas fueron los esfuerzos cortantes, vorticidad y caída de presión. ABSTRACT Nowadays, restenosis after percutaneous dilation is the major drawback of coronary angioplasty. It represents a special form of atherosclerosis due to the healing process secondary to extensive vessel trauma induced after intracoronary balloon inflation. The use of coronary stents may decrease the incidence of this phenomenon. Unfortunately, intra-stent restenosis still occurs in 20-30% of the cases following the stent implantation. Most experiments suggest a correlation between low wall shear stress and wall thickness. The preferential locations for the atherosclerotic plaque are bifurcations. The objective of this work is to analyze the local hemodynamic changes caused in a coronary bifurcation by three different stenting techniques: simple stenting of the main vessel, simple stenting of the main vessel with kissing balloon in the side branch and culotte. To carry out this study an idealized geometry of a coronary bifurcation is used, and two bifurcation angles, 45º and 90º, are chosen as representative of the wide variety of real configurations. Both numerical simulations and experimental measurements are performed. First, steady simulations are carried out with the commercial code Ansys-Fluent, then, experimental measurements with PIV (Particle Image Velocimetry), obtained in the laboratory, are used to validate the numerical simulations. The steady computational simulations show a good overall agreement with the experimental data. Then, pulsatile flow is considered to take into account the transient effects. The time averaged wall shear stress, oscillatory shear index and pressure drop obtained numerically are used to compare the behavior of the stenting techniques. In a second step, the rheologic behavior of blood was considered comparing Newtonian, Carreau and Power Law models. Finally, as a result of previous investigations with conventional stents and after the recent emergence of several devices specifically designed for coronary bifurcations angioplasty, the hemodynamic performance of these new devices (Stentys) was compared to conventional ones and techniques in a coronary bifurcation model. Four different stenting techniques: simple stenting of the main vessel, simple stenting of the side vessel, culotte deploying the first stent in the main vessel and culotte deploying the first stent in the side vessel have been considered. To carry out this study an idealized geometry of a coronary bifurcation is used. A 45 degrees bifurcation angle is considered and the daughter branches diameters are obtained according to the Finet law. Both experiments in the laboratory and numerical simulations were used , focusing on important factors for the atherosclerosis development, like the wall shear stress, the oscillation shear index, the pressure loss and the vorticity.