37 resultados para Height Tolerance of Concrete Blocks
em Universidad Politécnica de Madrid
Resumo:
Damage tolerance of high strength cold-drawn ferritic–austenitic stainless steel wires is assessed by means of tensile fracture tests of cracked wires. The fatigue crack is transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behaviour is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D is used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plane specimens extracted from the cold-drawn wires. Finally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic–austenitic stainless steel wires is compared with that of an elementary plastic collapse model and existing data of two types of high strength eutectoid steel currently used as prestressing steel for concrete.
Resumo:
The study brings new insights on the hydrogen assisted stress corrosion on damage tolerance of a high-strength duplex stainless steel wire which concerns its potential use as active reinforcement for concrete prestressing. The adopted procedure was to experimentally state the effect of hydrogen on the damage tolerance of cylindrical smooth and precracked wire specimens exposed to stress corrosion cracking using the aggressive medium of the standard test developed by FIP (International Prestressing Federation). Stress corrosion testing, mechanical fracture tests and scanning electron microscopy analysis allowed the damage assessment, and explain the synergy between mechanical loading and environment action on the failure sequence of the wire. In presence of previous damage, hydrogen affects the wire behavior in a qualitative sense, consistently to the fracture anisotropy attributable to cold drawing, but it does not produce quantitative changes since the steel fully preserves its damage tolerance.
Resumo:
The Kariba dam is undergoing concrete expansion as a result of an alkali-aggregate reaction. The model adopted to simulate the process is explained in the paper; it is based on the model first proposed by Ulm et al, as later modified by Saouma and Perotti. It has been implemented in the commercial finite element code Abaqus and applied to solve the benchmark problem. The parameters of the model were calibrated using the data recorded up to 1995. The calibrated model was then used for predicting the evolution of the dam up to the present date. Apart from this prediction the paper offers a number of conclusions, such as the fact that the stress level appears to have a major influence on the expansion process; and it presents some suggestions to improve the formulation of the benchmark, such as providing temperature data and widening the locations and conditions of the data employed in the calibration
Resumo:
The aim of this work is to relate the curing conditions of concrete and the addition of an air-entraining admixture with the damage caused by freeze–thaw cycles. In countries with a continental climate, the curing of concrete in summer is performed under climatic conditions of high temperature and low humidity, and during the winter the concrete suffers conditions of freeze–thaw, often accompanied by the use of de-icing salts. This paper shows the experimental results of the behaviour of concrete specimens cured under climatic summer conditions (high temperature and low humidity) and then subjected to freeze–thaw cycles. Curing of the specimens includes conditions of good and bad practice in relation to wetting and protection of the concrete. It also examines the effectiveness of using an air-entraining admixture in both cases. The experimental programme includes an evaluation of the mechanical properties of the concrete, the study of the cement hydration and the measurement of the volume and pore sizes of the concrete. These tests were performed before and after the application of the freeze–thaw cycles. The results obtained showed that the specimens without air-entraining admixture show a deterioration of mechanical properties after the freeze–thaw test. However, the inclusion of air bubbles benefits the behaviour of concrete against freeze–thaw cycles so even better mechanical properties after the test were observed. This anomalous behaviour is because the cement hydration process continues over the freeze–thaw tests, closing the pore structure. This aspect has been confirmed with the DTA and TG tests performed
Resumo:
Un modelo numérico llamado elemento junta expansiva fue programado para simular la expansión mecánica del óxido y estudiar la fisuración en el hormigón circundante. El elemento junta expansiva trabaja con elementos finitos con fisura cohesiva embebida adaptable para simular la fractura del hormigón según el modelo de fisura cohesiva. Se ha comprobado que el modelo reproduce correctamente el patrón de fisuración del hormigón que se obtiene en ensayos de corrosión acelerada. En este trabajo, se realiza un estudio paramétrico del elemento junta expansiva para establecer los límites de los parámetros constitutivos del óxido. Se simula una cierta expansión variando los valores de los parámetros del óxido y se estudian la apertura de fisura y las tensiones resultantes en el hormigón. Se determina el rango de valores para los que los resultados de las simulaciones son prácticamente iguales, con el menor número posible de iteraciones.
Resumo:
The use of fly ash (FA) as an admixture to concrete is broadly extended for two main reasons: the reduction of costs that supposes the substitution of cement and the micro structural changes motivated by the mineral admixture. Regarding this second point, there is a consensus that considers that the ash generates a more compact concrete and a reduction in the size of the pore. However, the measure in which this contributes to the pozzolanic activity or as filler is not well defined. There is also no justification to the influence of the physical parameters, fineness of the grain and free water, in its behavior. This work studies the use of FA as a partial substitute of the cement in concretes of different workability (dry and wet) and the influence in the reactivity of the ash. The concrete of dry consistency which serves as reference uses a cement dose of 250 Kg/m 3 and the concrete of fluid consistency utilized a dose of cement of 350 Kg/m 3 . Two trademark of Portland Cement Type 1 were used. The first reached the resistant class for its fineness of grain and the second one for its composition. Moreover, three doses of FA have been used, and the water/binder ratio was constant in all the mixtures. We have studied the mechanical properties and the micro-structure of the concretes by means of compressive strength tests, mercury intrusion porosimetry (MIP) and thermal analysis (TA). The results of compressive strength tests allow us to observe that concrete mixtures with cements of the same classification and similar dosage of binder do not present the same mechanical behavior. These results show that the effective water/binder ratio has a major role in the development of the mechanical properties of concrete. The study of different dosages using TA, thermo-gravimetry and differential thermal analysis, revealed that the portlandite content is not restrictive in any of the dosages studied. Again, this proves that the rheology of the material influences the reaction rate and content of hydrated cement products. We conclude that the available free water is determinant in the efficiency of pozzolanic reaction. It is so that in accordance to the availability of free water, the ashes can react as an active admixture or simply change the porous distribution. The MIP shows concretes that do not exhibit significant changes in their mechanical behavior, but have suffered significant variation in their porous structure
Resumo:
In the Standard EHE 08, for the first time, durability acquires the status of Limit State. Article 8 provides that the term Durability limit state, produced by physical and chemical actions, different loads and actions of structural analysis, which can degrade the concrete and reinforcement to unacceptable limits. The verification of this limit state can be done through a procedure set out in the provisions of the Standard. This procedure is based on the use of tables that, depending on the aggressiveness of the environment in which the structure is the concrete strength and the life of the project, setting the quality of the concrete cover (minimum thickness and maximum water cement ratio of concrete used) and the maximum crack width. This procedure, simple in its application, provides highly secure solutions. In addition, on Annex 9, the Standard EHE 08 offers models for testing the durability limit state in cases of corrosion of reinforcement due to carbonation of concrete or entry of chloride ions. The results obtained with these models are tighter than those obtained with the procedure of the articles. In this paper we use both methods in the study of reinforced concrete structures with potential problems of corrosion of reinforcement due to carbonation of concrete. Later checking the results obtained by both procedures. Results demonstrate that the use of the models listed in Annex 9 of Standard EHE 08 offer cheaper solutions than those obtained using the procedure of the articles
Resumo:
The Kariba dam is undergoing concrete expansion as a result of an alkali-aggregate reaction. The model adopted to simulate the process is explained in the paper; it is based on the model first proposed by Ulm et al, as later modified by Saouma and Perotti. It has been implemented in the commercial finite element code Abaqus and applied to solve the benchmark problem. The parameters of the model were calibrated using the data recorded up to 1995. The calibrated model was then used for predicting the evolution of the dam up to the present date. Apart from this prediction the paper offers a number of conclusions, such as the fact that the stress level appears to have a major influence on the expansion process; and it presents some suggestions to improve the formulation of the benchmark, such as providing temperature data and widening the locations and conditions of the data employed in the calibration
Resumo:
El objetivo principal de este trabajo de investigación es estudiar las propiedades del árido reciclado mixto para la fabricación de hormigón reciclado en aplicaciones no estructurales. Se ha realizado la caracterización completa de 35 muestras de áridos reciclados mixtos gruesos de distinta calidad, procedentes de 13 plantas de tratamiento diferentes de la geografía española. Se han estudiado las correlaciones que existen entre las diferentes propiedades, en particular, con la absorción de agua, el contenido de sulfatos y la composición. Se propone una clasificación de los áridos reciclados y se limita de forma indicativa el contenido de yeso para que una muestra de árido reciclado mixto cumpla con la limitación del 0,8% de los sulfatos solubles en ácido de la Instrucción EHE-08. Recycling of construction and demolition waste (CDW) has become a widespread concern in Spain for the last years, as a way to preserve natural resources and achieve a better control of waste disposal sites.Specific applications which make use of mixed recycled aggregates are of great importance, as this types of aggregates constitute the majority of the total production. Structural and non-structural concrete is one of the possible applications, being this the main goal of our study. This paper presents a study on the physical and chemical characteristics of mixed recycled aggregates which have been obtained from different CDW treatment plants of Spain. Correlations between the different properties were investigated in order to find criterions of acceptance for recycled aggregates to be used in concrete. The comparison between the properties offers the possibility of pre-selecting a great quantity of mixed recycled aggregates, these being suitable for either structural and non-structural concrete. The determination of water absorption and the gypsum content are good indicators in order to evaluate the quality of the mixed recycled aggregates for its application in the production of concrete.
Resumo:
In many university courses such as Building Engineering or Technical Architectural, the high density of the contents included in the curriculum, make the student, after graduation, unable to develop the skills already acquired and evaluated in the disciplines of the first courses. From the Group of Educational Innovation at the Polytechnic University of Madrid (UPM) "Teaching of Structural Concrete" (GIEHE) we have conducted a study in which are valued specific skills acquired by students after the first courses of career. We have worked with students from UPM fourth-year career and with Technical Architecture students who have completed their studies and also have completed the Adaptation Course of Technical Architecture to the Building Engineer. The work is part of the Educational Innovation Project funded by the UPM "Integration of training and assessment of generic and specific skills in structural concrete" We have evaluated specific skills learned in the areas of durability and control of structural concrete structures. The results show that overall, students are not able to fully develop the skills already acquired earlier, even being these essential to their professional development. Possibly, the large amount of content taught in these degrees together with a teaching and assessment of "flat profile", ie, which are presented and evaluated with the same intensity as the fundamental and the accessory, are causes enough to cause these results.
Resumo:
En este trabajo se estudia la relacion entre la resistencia al frio de 8 variedades de olivo observada en campo y la medida en laboratorio, a partir de la temperatura de congelacion letal. Se observo una correlacion entre el porcentaje de brotes helado y la temperatura de congelacion letal 50%. Las variedades mas resistentes fueron Cornicabra, Arbequina y Picual. Las mas sensibles fue Empeltre.
Resumo:
Cracking of reinforced concrete can occur in certain environments due to rebar corrosion. The oxide layer growing around the bars introduces a pressure which may be enough to lead to the fracture of concrete. To study such an effect, the results of accelerated corrosion tests and finite ele- ment simulations are combined in this work. In previous works, a numerical model for the expansive layer, called expansive joint element , was programmed by the authors to reproduce the effect of the oxide over the concrete. In that model, the expansion of the oxide layer in stress free conditions is simulated as an uniform expansion perpendicular to the steel surface. The cracking of concrete is simulated by means of finite elements with an embedded adaptable cohesive crack that follow the standard cohesive model. In the present work, further accelerated tests with imposed constant cur- rent have been carried out on the same type of specimens tested in previous works (with an embedded steel tube), while measuring, among other things, the main-crack mouth opening. Then, the tests have been numerically simulated using the expansive joint element and the tube as the corroding electrode (rather than a bar). As a result of the comparison of numerical and experimental results, both for the crack mouth opening and the crack pattern, new insight is gained into the behavior of the oxide layer. In particular, quantitative assessment of the oxide expansion relation is deduced from the ex- periments, and a narrower interval for the shear stiffness of the oxide layer is obtained, which could not be achieved using bars as the corroding element, because in that case the numerical results were insensitive to the shear stiffness of the oxide layer within many orders of magnitude
Resumo:
In this work, cracking of concrete due to steel reinforcement corrosion is experimentally and numerically studied. The tests combined accelerated corrosion—to generate the cracks—with impregnation under vacuum with resin containing fluorescein—to enhance their visibility under ultraviolet light. In parallel, a model—called expansive joint element—was developed to simulate the expansion of the oxide and finite elements with an embedded adaptable cohesive crack were used to describe concrete cracking. The results show that a good agreement exists between the experimental and numerical crack patterns, which constitutes promising progress towards a comprehensive understanding of corrosion-induced cracking in reinforced concrete.
Resumo:
If reinforced concrete structures are to be safe under extreme impulsive loadings such as explosions, a broad understanding of the fracture mechanics of concrete under such events is needed. Most buildings and infrastructures which are likely to be subjected to terrorist attacks are borne by a reinforced concrete (RC) structure. Up to some years ago, the traditional method used to study the ability of RC structures to withstand explosions consisted on a choice between handmade calculations, affordable but inaccurate and unreliable, and full scale experimental tests involving explosions, expensive and not available for many civil institutions. In this context, during the last years numerical simulations have arisen as the most effective method to analyze structures under such events. However, for accurate numerical simulations, reliable constitutive models are needed. Assuming that failure of concrete elements subjected to blast is primarily governed by the tensile behavior, a constitutive model has been built that accounts only for failure under tension while it behaves as elastic without failure under compression. Failure under tension is based on the Cohesive Crack Model. Moreover, the constitutive model has been used to simulate the experimental structural response of reinforced concrete slabs subjected to blast. The results of the numerical simulations with the aforementioned constitutive model show its ability of representing accurately the structural response of the RC elements under study. The simplicity of the model, which does not account for failure under compression, as already mentioned, confirms that the ability of reinforced concrete structures to withstand blast loads is primarily governed by tensile strength.
Resumo:
This paper summarizes the research activities focused on the behaviour of concrete and concrete structures subjected to blast loading carried out by the Department of Materials Science of the Technical University of Madrid (PUM). These activities comprise the design and construction of a test bench that allows for testing up to four planar concrete specimens with one single explosion, the study of the performance of different protection concepts for concrete structures and, finally, the development of a numerical model for the simulation of concrete structural elements subjected to blast. Up to date 6 different types of concrete have been studied, from plain normal strength concrete, to high strength concrete, including also fibre reinforced concretes with different types of fibres. The numerical model is based on the Cohesive Crack Model approach, and has been developed for the LSDYNA finite element code through a user programmed subroutine. Despite its simplicity, the model is able to predict the failure patterns of the concrete slabs tested with a high level of accuracy