11 resultados para HEAT EXCHANGER EFFICIENCY

em Universidad Politécnica de Madrid


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A generalized Lévêque solution is presented for the conjugate fluid–fluid problem that arises in the thermal entrance region of laminar counterflow heat exchangers. The analysis, carried out for constant property fluids, assumes that the Prandtl and Peclet numbers are both large compared to unity, and neglects axial conduction both in the fluids and in the plate, assumed to be thermally thin. Under these conditions, the thermal entrance region admits an asymptotic self-similar description where the temperature varies as a power ϳ of the axial distance, with the particularity that the self-similarity exponent must be determined as an eigenvalue by solving a transcendental equation arising from the requirement of continuity of heat fluxes at the heat conducting wall. Specifically, the analysis reveals that j depends only on the lumped parameter ƙ = (A2/A1)1/3 (α1/α2)1/3(k2/k1), defined in terms of the ratios of the wall velocity gradients, A, thermal diffusivities, α i, and thermal conductivities,k i, of the fluids entering, 1, and exiting, 2, the heat exchanger. Moreover, it is shown that for large (small) values of K solution reduces to the classical first (second) Lévêque solution. Closed-form analytical expressions for the asymptotic temperature distributions and local heat-transfer rate in the thermal entrance region are given and compared with numerical results in the counterflow parallel-plate configuration, showing very good agreement in all cases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The supercritical Rankine power cycle offers a net improvement in plant efficiency compared with a subcritical Rankine cycle. For fossil power plants the minimum supercritical steam turbine size is about 450MW. A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013, confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe. In this context, this analysis is focused on integrating a line-focus solar field with a supercritical Rankine power cycle. For this purpose two heat transfer fluids were assessed: direct steam generation and molten salt Hitec XL. To isolate solar field from high pressure supercritical water power cycle, an intermediate heat exchanger was installed between linear solar collectors and balance of plant. Due to receiver selective coating temperature limitations, turbine inlet temperature was fixed 550ºC. The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output. Plant performance was assessed at design-point in the supercritical power plant (between 43-45% net plant efficiency depending on balance of plantconfiguration), and in the subcritical plant configuration (~40% net plant efficiency). Regarding the balance of plant configuration, direct reheating was adopted as the optimum solution to avoid any intermediate heat exchanger. One direct reheating stage between high pressure turbine and intermediate pressure turbine is the common practice; however, General Electric ultrasupercritical(350 bar) fossil power plants also considered doubled-reheat applications. In this study were analyzed heat balances with single-reheat, double-reheat and even three reheating stages. In all cases were adopted the proper reheating solar field configurations to limit solar collectors pressure drops. As main conclusion, it was confirmed net plant efficiency improvements in supercritical Rankine line-focus (parabolic or linear Fresnel) solar plant configurations are mainly due to the following two reasons: higher number of feed-water preheaters (up to seven)delivering hotter water at solar field inlet, and two or even three direct reheating stages (550ºC reheating temperature) in high or intermediate pressure turbines. However, the turbine manufacturer should confirm the equipment constrains regarding reheating stages and number of steam extractions to feed-water heaters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Probabilistic Safety Assessment (PSA) is being developed for a steam-methane reforming hydrogen production plant linked to a High-Temperature Gas Cooled Nuclear Reactor (HTGR). This work is based on the Japan Atomic Energy Research Institute’s (JAERI) High Temperature Test Reactor (HTTR) prototype in Japan. This study has two major objectives: calculate the risk to onsite and offsite individuals, and calculate the frequency of different types of damage to the complex. A simplified HAZOP study was performed to identify initiating events, based on existing studies. The initiating events presented here are methane pipe break, helium pipe break, and PPWC heat exchanger pipe break. Generic data was used for the fault tree analysis and the initiating event frequency. Saphire was used for the PSA analysis. The results show that the average frequency of an accident at this complex is 2.5E-06, which is divided into the various end states. The dominant sequences result in graphite oxidation which does not pose a health risk to the population. The dominant sequences that could affect the population are those that result in a methane explosion and occur 6.6E-8/year, while the other sequences are much less frequent. The health risk presents itself if there are people in the vicinity who could be affected by the explosion. This analysis also demonstrates that an accident in one of the plants has little effect on the other. This is true given the design base distance between the plants, the fact that the reactor is underground, as well as other safety characteristics of the HTGR. Sensitivity studies are being performed in order to determine where additional and improved data is needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este proyecto trata sobre la gestión del boil-off gas, o BOG (vapor de gas natural que se produce en las instalaciones de gas natural licuado de las plantas de regasificación), generado en la planta de regasificación de Gas Natural Licuado de Cartagena, tanto en las situaciones en las que se opera por debajo del mínimo técnico, como en las cargas y descargas de buques, en las cuales se ha de gestionar una cantidad del boil-off adicional. Para recuperar el boil-off, las plantas cuentan con un relicuador (intercambiador de calor) en el que el BOG es relicuado por el GNL que se envía a los vaporizadores para ser regasificado y emitido a la red. De forma complementaria cuentan también con una antorcha/venteo donde se quema el exceso de boil-off que no puede ser tratado por el relicuador. Se procede a un análisis de la situación actual, y de cómo la baja demanda de regasificación dificulta la gestión del boil-off. Se simula el proceso de relicuación actual en distintas situaciones de operación. Ante la situación de baja demanda, ha aumentado considerablemente el número de días en los que las plantas españolas en general, y la planta de Cartagena en particular, operan por debajo del mínimo técnico, que es el nivel de producción mínimo para recuperar todo el boil-off generado en cualquier situación de operación al tiempo que mantiene en frío todas las instalaciones, y garantiza el 100% de disponibilidad inmediata del resto de los equipos en condiciones de seguridad de funcionamiento estable. Esta situación supone inconvenientes tanto operativos como medioambientales y acarrea mayores costes económicos, a los cuales da solución el presente proyecto, decidiendo qué alternativa técnica es la más adecuada y definiéndola. Abstract This project is about the management of the boil-off gas (BOG), natural vapour gas that is produced in liquefied natural gas (LNG) regasification plants. Specifically, the study is focused on the LNG regasification plant located in Cartagena, when it operates both below the technical minimum level of regasification and in the loading/unloading of LNG carriers, situations when it is needed to handle additional BOG. In order to make the most of BOG, the plants have a re-condenser (heat exchanger). Here, the BOG is re-liquefied by the LNG that is submitted to the vaporizers and delivered to the grid. The plants also have a flare/vent where the excess of BOG that cannot be treated by the re-condenser is burned. An analysis of the current situation of the demand is performed, evaluating how low markets demand for regasification difficult the BOG management. Besides, it is simulated the current re-liquefaction operating in different environments. Due to the reduction of the demand for natural gas, the periods when Spanish LNG regasification plants (and particularly the factory of Cartagena) are operating below the technical minimum level of regasification are more usual. This level is the minimum production to recover all the BOG generated in any operating situation while maintaining cold all facilities, fully guaranteeing the immediate availability from other equipment in a safely and stable operation. This situation carries both operational and environmental drawbacks, and leads to higher economic costs. This project aims to solve this problem, presenting several technical solutions and deciding which is the most appropriate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Efficient high speed propulsion requires exploiting the cooling capability of the cryogenic fuel in the propulsion cycle. This paper presents the numerical model of a combined cycle engine while in air turbo-rocket configuration. Specific models of the various heat exchanger modules and the turbomachinery elements were developed to represent the physical behavior at off-design operation. The dynamic nature of the model allows the introduction of the engine control logic that limits the operation of certain subcomponents and extends the overall engine operational envelope. The specific impulse and uninstalled thrust are detailed while flying a determined trajectory between Mach 2.5 and 5 for varying throttling levels throughout the operational envelope.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Direct Steam Generation (DSG) in Linear Fresnel (LF) solar collectors is being consolidated as a feasible technology for Concentrating Solar Power (CSP) plants. The competitiveness of this technology relies on the following main features: water as heat transfer fluid (HTF) in Solar Field (SF), obtaining high superheated steam temperatures and pressures at turbine inlet (500ºC and 90 bar), no heat tracing required to avoid HTF freezing, no HTF degradation, no environmental impacts, any heat exchanger between SF and Balance Of Plant (BOP), and low cost installation and maintenance. Regarding to LF solar collectors, were recently developed as an alternative to Parabolic Trough Collector (PTC) technology. The main advantages of LF are: the reduced collector manufacturing cost and maintenance, linear mirrors shapes versus parabolic mirror, fixed receiver pipes (no ball joints reducing leaking for high pressures), lower susceptibility to wind damages, and light supporting structures allowing reduced driving devices. Companies as Novatec, Areva, Solar Euromed, etc., are investing in LF DSG technology and constructing different pilot plants to demonstrate the benefits and feasibility of this solution for defined locations and conditions (Puerto Errado 1 and 2 in Murcia Spain, Lidellin Newcastle Australia, Kogran Creek in South West Queensland Australia, Kimberlina in Bakersfield California USA, Llo Solar in Pyrénées France,Dhursar in India,etc). There are several critical decisions that must be taken in order to obtain a compromise and optimization between plant performance, cost, and durability. Some of these decisions go through the SF design: proper thermodynamic operational parameters, receiver material selection for high pressures, phase separators and recirculation pumps number and location, pipes distribution to reduce the amount of tubes (reducing possible leaks points and transient time, etc.), etc. Attending to these aspects, the correct design parameters selection and its correct assessment are the main target for designing DSG LF power plants. For this purpose in the recent few years some commercial software tools were developed to simulatesolar thermal power plants, the most focused on LF DSG design are Thermoflex and System Advisor Model (SAM). Once the simulation tool is selected,it is made the study of the proposed SFconfiguration that constitutes the main innovation of this work, and also a comparison with one of the most typical state-of-the-art configuration. The transient analysis must be simulated with high detail level, mainly in the BOP during start up, shut down, stand by, and partial loads are crucial, to obtain the annual plant performance. An innovative SF configurationwas proposed and analyzed to improve plant performance. Finally it was demonstrated thermal inertia and BOP regulation mode are critical points in low sun irradiation day plant behavior, impacting in annual performance depending on power plant location.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El consumo de energía es responsable de una parte importante de las emisiones a la atmósfera de CO2, que es uno de los principales causantes del efecto invernadero en nuestro planeta. El aprovechamiento de la energía solar para la producción de agua caliente, permite economizar energía y disminuir el impacto del consumo energético sobre el medio ambiente y por tanto un menor impacto medioambiental. El objetivo de la presente investigación consiste en estudiar el aprovechamiento solar para el calentamiento de los fangos en los digestores anaerobios mediante agua caliente circulando en el interior de un serpentín que rodea la superficie de dicho digestor, como apoyo a los métodos convencionales del calentamiento de fangos como la resistencia eléctrica o el intercambiador de calor mediante la energía obtenida por el gas metano producido en la digestión anaerobia. Para el estudio se utilizaron 3 digestores, dos delos cuales se calentaron con agua caliente en el interior de un serpentín (uno aislado mediante una capa de fibra de vidrio y poliuretano y otro sin aislar).El tercer digestor no tenía calentamiento exterior con el objetivo de observar su comportamiento y comparar su evolución con el resto de los digestores .La comparación de los digestores 1 y 2 nos permitió estudiar la conveniencia de proveer de aislamiento al digestor. La transferencia de calor mediante serpentín de cobre dio valores comprendidos entre 83 y 92%. La aplicación de la instalación a una depuradora a escala real para mantenimiento en el interior del digestor a T=32ºC en diferentes climas: climas templados, cálidos y fríos, consistió en el cálculo de la superficie de colectores solares y superficie de serpentín necesario para cubrir las necesidades energéticas anuales de dicho digestor, así como el estudio de rentabilidad de la instalación, dando los mejores resultados para climas cálidos con períodos de retorno de 12 años y una tasa interna de rentabilidad (TIR) del 16% obteniendo una cobertura anual del 79% de las necesidades energéticas con energía solar térmica. Energy consumption accounts for a significant part of the emissions of CO2, which is one of the main causes of the greenhouse effect on our planet. The use of solar energy for hot water production. can save energy and reduce the impact of energy consumption on the environment and therefore a reduced environmental impact. The objective of this research is to study the solar utilization for heating the sludge in anaerobic digesters by hot water circulating inside a coil surrounding the surface of digester, to support conventional heating methods sludge as the electrical resistance or heat exchanger by energy generated by the methane gas produced in the anaerobic digestion. To study 3 digesters used two models which are heated with hot water within a coil (one insulated by a layer of fiberglass and polyurethane and other uninsulated) .The third digester had no external heating in order to observe their behavior and compare their evolution with the rest of the .The comparison digesters digesters 1 and 2 allowed us to study the advisability of providing insulation to the digester. Heat transfer through copper coil gave values between 83 and 92%. The installation application to a treatment for maintaining full scale within the digester at T = 32ºC in different climates: temperate, warm and cold climates, consisted of calculating the surface area of solar collectors and coil required to cover the annual energy needs of the digester, and the study of profitability of the installation, giving the best results for hot climates with return periods of 12 years and an internal rate of return (IRR) of 16% achieving an annual coverage of 79 % of energy needs with solar energy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to evaluate different management strategies to optimize rabbit production under chronic heat stress. To achieve it, three trials were conducted. In the first trial, to find the optimal cage density in tropical very dry forest condition, were measured growth performance, mortality rate, injured animals and carcass performance over an initial population of 300 cross-breed rabbits of New Zealand, California, Butterfly, Dutch and Satin, weaned at 30 days (535 ± 8 g, standard error). Treatments evaluated were: 6, 12, 18 and 24 rabbits/m2 (3, 6, 9 and 12 rabbits/cage, respectively, each cage of 0.5 m2). The maximal temperature-humidity index indicated a severe heat stress from weaning to 2.2 kg body weight (experimental time). At the end of experimental period 10, 20, 30 and 30 rabbits from the treatments of 6, 12, 18 and 24 rabbits/m2, respectively, were slaughtered and carcass performance recorded. Average daily gain and feed intake decreased by 0.31 ± 0.070 and 1.20 ± 0.25 g, respectively, per each unit that the density increased at the beginning of the experiment (P = 0.001). It increased the length of the fattening period by 0.91 ± 0.16 d (P = 0.001) per each unit of increment of density. However, rabbit production (kg/m2) increased linear and quadratically with the density (P < 0.008). Animals housed at the highest density compared to the lower one tended to show a higher incidence of ringworm (68.9 vs 39.4%; P = 0.075), injured animals (16.8 vs 3.03%; P = 0.12) and mortality (20.5 vs 9.63%; P = 0.043). The proportion of scapular fat (P = 0.042) increased linearly with increasing levels of density. Increasing density reduced linearly dorsal length (P = 0.001), and reduced linear and quadratically drip loss percentage (P = 0.097 and 0.018, respectively). In the second trial, 46 nulliparous rabbit does (23 clipped and 23 unclipped) with a BW of 3.67 ± 0.05 kg (s.e.) were used to evaluate heat stress and circadian rhythms comparing unclipped and clipped rabbit does, and to study if a more extensive breeding system increase litters performance at weaning without impairing rabbit doe performance,. Rectal temperature, feed and water 4 intake were recorded for 24 h. Rabbit does were mated 7 d after circadian measurements, and randomly assigned to two breeding systems. Control (C): mated at 14 d after parturition + litter weaned at 35 d of age. Extensive (E): mate at 21 after parturition + litter weaned at 42 d of age. The first three cycles were evaluated concerning to rabbit doe and litter performance. Two hundred twenty eight weaned rabbits, were divided into two cage sizes: 0.5 and 0.25 m2 with same density (16 rabbit/m2) and growing performance was recorded. Farm and rectal temperatures were minimal and feed and water intake maximal during the night (P < 0.001). Unclipped rabbit does showed higher rectal temperature (P = 0.045) and lower feed intake respect to clipped does (P = 0.019) which suggest a lower heat stress in the latter. Kits weaned per litter was reduced by 33% (P=0.038) in C group. This reduction was more important in the 2nd and 3rd cycles compared to the first (P ≤ 0.054). Rabbit doe feed efficiency tended to decrease in E respect C group (P = 0.093), whereas it was impaired from the first to the third cycle by 48% (P = 0.014). Growing rabbits from the E group were heavier at weaning (by 38%. P < 0.001), showed a higher feed intake (+7.4%) and lower feed efficiency (-8.4%) throughout the fattening period (P ≤ 0.056) respect to C group. Cage size had minor influence in growing performance. In the third trial, forty five non pregnant and non lactating rabbit does (21 nulliparous and 24 multiparous) were assigned randomly to farm water and to potable water to study if a water quality improvement can affect positively rabbit doe response to heat stress during pregnancy and lactation. A transponder was implanted in each animal to record subcutaneous temperature at 07:30 and 14:30 h. Experimental period extended from pregnancy (with no lactation) to the next lactation (until day 28). Body temperature and milk production were recorded daily, and body condition, feed and water intake weekly. Water quality did not affect any trait (P ≥ 0.15). Pregnant rabbit does were classified as does that weaned (W: 47%), not weaned (NW: 44%) or those pregnant that did not deliver (NB: 9%). Body temperature and feed intake decreased during pregnancy (P ≤ 0.031), but water intake remained constant. In this period body temperature decreased with metabolic weight (P ≤ 0.009). In W and NW does, 5 from mating to birth energy and protein balance impaired (P≤0.011). Body temperature of W does tended to be the lowest (P ≤ 0.090). Pregnancy length and total number of kits born tended to be longer and higher in NW than in W does (P = 0.10 and 0.053, respectively). Kit mortality at birth and from birth to 14 d of lactation was high, being worse for NW than for W does (97 vs. 40%; P<0.001). Body temperature during lactation was maximal at day 12, and milk production increased it (P ≤ 0.025). . In conclusion, in our heat stress conditions densities higher than 18 rabbits/m2 (34 kg/m2) at the end of fattening, are not recommended despite cage size, gestation and lactation productivity impaired not only when lactation is extended and along successive reproductive cycles but also due to a reduced embryo/kit survival and finally water quality improvement did not attenuate negative effect of heat stress. RESUMEN El propósito de éste trabajo fue evaluar diferentes estrategias de manejo para optimizar la producción de conejos bajo estrés térmico. Para lo cual se desarrollaron tres experimentos. En el primer experimento, para encontrar el número óptimo de gazapos por m2 de jaula durante el cebo en condiciones de bosque muy seco tropical, se estudiaron los rendimientos durante el cebo, mortalidad, animales lesionados y rendimiento de la canal sobre una población inicial de 300 conejos mestizos de Nueva Zelanda, California, Mariposa, Holandés y Satin, destetados a los 30 días de edad (535 ± 8g, error estándar). Los tratamientos evaluados fueron: 6, 12, 18 y 24 conejos/m2 (3, 6, 9 y 12 conejos/jaula, respectivamente, en jaulas de 0.5 m2). Durante el período experimental (destete a 2.2 kg de peso vivo), se observaron valores de THI correspondientes con un estrés térmico severo (THI max. De 31 a 35). Al final del período experimental, 10, 20, 30, y 30 conejos de los tratamientos con densidades de 6, 12, 18 y 24 conejos/m2, respectivamente, fueron sacrificados y su canal fue valorada. El promedio de la ganancia diaria y el consumo de alimento disminuyeron en 0.31 ± 0.070 y 1.20 ± 0.25 g, respectivamente, por cada unidad de incremento en la densidad al inicio del experimento (P=0.001). Esto alargó el período de engorde en 0.91 ± 0.16 d (P=0.001) por cada unidad de incremento de la densidad. Sin embargo, la producción de conejos (kg/m2) aumentó lineal y cuadráticamente con la densidad (P<0.008). Los animales alojados en las mayores densidades en comparación con el resto tendieron a mostrar una mayore incidencia de tiña (68.9 vs 39.4%; P=0.075), de cantidad de animales heridos (16.8 vs 3.03%; P=0.12), así como de mortalidad (20.5 vs 9.63%; P=0.043). El aumento en la densidad aumentó linealmente la proporción de grasa escapular (P=0.042) y redujo linealmente la longitud dorsal (P=0.001), y lineal y cuadráticamente el porcentaje de pérdida por goteo (P=0.018). En el segundo experimento, 46 conejas nulliparas (23 rasuradas y 23 no rasuradas) con un peso vivo de 3.67 ± 0.05 kg (e.e.) fueron usadas para evaluar el estrés 8 térmico y los ritmos circadianos comparando conejas rasuradas o no, y estudiar si un sistema de crianza más extensivo mejora el desempeño de la camada al destete sin perjudicar la productividad de la coneja. Durante 24 h se midió la temperatura rectal, consumo de alimento y de agua. Las conejas fueron montadas 7 días después, y distribuidas en dos sistemas de crianza. El control (C): monta a 14 días posparto y destete a 35 d de edad. El extensivo (E): monta a 21 días posparto y destete a 42 d de edad. Se controló la productividad de la coneja y la camada durante los tres primeros ciclos. Doscientos veintiocho gazapos fueron distribuidos en dos tamaños de jaulas (0.5 y 0.25 m2) con la misma densidad (16 conejos/m2) y se controlaron sus rendimientos productivos. Durante la noche se observaron los valores mínimos para la temperatura ambiental y rectal, y los máximos para consumo de alimento y agua (P< 0.001). Las conejas no rasuradas mostraron mayor temperatura rectal (P=0.045) y menores valores de consumo de alimento con respecto a las conejas rasuradas (P=0.019), lo que sugiere un menor estrés térmico en las últimas. El número de gazapos destetados por camada se redujo en 33% (P=0.038) en el grupo C. Este comportamiento se acentuó en el 2do y 3er ciclo en comparación con el primero (P≤0.054). La eficiencia alimenticia de las conejas tendió a disminuir en el grupo E con respecto al grupo C (P=0.093), dicha tendencia se acentúa del primer al tercer ciclo en un 48% (P=0.014). Los gazapos en fase de crecimiento provenientes del grupo E fueron más pesados al momento del destete (en 38% P<0.001), mostrando un mayor consumo de alimento (+7.4%) y menor eficiencia alimenticia (-8.4%) a lo largo del engorde (P≤0.056) con respecto al grupo C. El tamaño de la jaula tuvo una mínima influencia en el comportamiento durante el crecimiento de éstos gazapos. En el tercer experimento, cuarenta y cinco conejas no gestantes ni lactantes (21 nulíparas y 24 multíparas) se les asignó al azar agua dos tipos de agua: común de la granja y agua potable, con el fin de estudiar si una mejora en la calidad del agua puede afectar positivamente la respuesta de la coneja al estrés térmico durante la gestación y la lactancia. Se les implantó un transponder para registrar la temperatura subcutánea a las 7:30 y a las 14:30 h. El período experimental se extendió desde la gestación (sin 9 lactancia) hasta la lactanción consecutiva (hasta los 28 días). La temperatura corporal y la producción de leche se controlaron diariamente, y la condición corporal, consumo de agua y alimento, semanalmente. La calidad del agua no afectó a ninguna variable (P≥0.15). Las conejas preñadas fueron clasificadas como conejas que destetaron (W: 47%), que no destetaron (NW:44%) o aquellas que no parieron (NB: 9%). La temperatura corporal y consumo de alimento disminuyeron durante la gestación (P≤0.031), mientras que el consumo de agua se mantuvo constante. La temperatura corporal descendió con el peso metabólico durante la gestación (P≤0.009). El balance de energía y proteína disminuyó desde la monta al parto para las conejas W y NW (P≤0.011). Durante la gestación la temperatura corporal tendió a ser menor en las conejas W (P≤0.090). La longitud de la gestación y el número total de gazapos nacidos tendieron a ser mayores en conejas NW que en conejas W (P=0.10 y 0.053, respectivamente). La mortalidad de los gazapos al parto y del parto a los 14 días de lactancia fue alta, siendo peor para las conejas NW que para las W (97 vs 40%; P<0.001). Durante la lactancia la temperatura corporal alcanzó su valor máximo para el día 12, y la producción de leche indujo un incremento en la misma (P≤0.025). En conclusión, en nuestras condiciones de estrés térmico y sin importar el tamaño de la jaula, no se recomiendan densidades mayores a 18 conejos/m2 (34 kg/m2) al final del engorde. La productividad de la gestación y la lactancia disminuyen cuando la lactancia es mayor y se suceden varios ciclos reproductivos seguidos. Esto se debe al efecto negativo del estrés térmico sobre la vitalidad y supervivencia del embrión/gazapo. La mejora de la calidad del agua atenuó el efecto negativo del estrés térmico. Las conejas más productoras parece que son aquéllas que consiguen manejar mejor el estrés térmico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The annual grass Brachypodium distachyon has been recently recognized as the model plant for functional genomics of temperate grasses, including cereals of economic relevance like wheat and barley. Sixty-two lines of B. distachyon were assessed for response to drought stress and heat tolerance. All these lines, except the reference genotype BD21, derive from specimens collected in 32 distinct locations of the Iberian Peninsula, covering a wide range of geo- climatic conditions. Sixteen lines of Brachypodium hybridum, an allotetraploid closely related to B. distachyon were used as reference of abiotic-stress well-adapted genotypes. Drought tolerance was assessed in a green-house trial. At the rosette-stage, no irrigation was applied to treated plants whereas their replicates at the control were maintained well watered during all the experiment. Thermographic images of treated and control plants were taken after 2 and 3 weeks of drought treatment, when stressed plants showed medium and extreme wilting symptoms. The mean leaf temperature of stressed (LTs) and control (LTc) plants was estimated based upon thermographic records from selected pixels (183 per image) that strictly correspond to leaf tissue. The response to drought was based on the analysis of two parameters: LTs and the thermal difference (TD) between stressed and control plants (LTs – LTc). The response to heat stress was based on LTc. Comparison of the mean values of these parameters showed that: 1) Genotypes better adapted to drought (B. hybridum lines) presented a higher LTs and TD than B. distachyon lines. 2) Under high temperature conditions, watered plants of B. hybridum lines maintained lower LTc than those of B. distachyon. Those results suggest that in these species adaptation to drought is linked to a more efficient stomata regulation: under water stress stomata are closed, increasing foliar temperature but also water use efficiency by reducing transpiration. With high temperature and water availability the results are less definite, but still seems that opening stomata allow plants to increase transpiration and therefore to diminish foliar temperature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El interés por los sistemas fotovoltaicos de concentración (CPV) ha resurgido en los últimos años amparado por el desarrollo de células multiunión de muy alta eficiencia basadas en semiconductores de los grupos III-V. Estas células han permitido obtener módulos de concentración con eficiencias que prácticamente duplican las del panel plano y que llegan al 35% en los módulos récord. Esta tesis está dedicada al diseño y la implementación experimental de nuevos conceptos que permitan obtener módulos CPV que no sólo alcancen una eficiencia alta en condiciones estándar sino que, además, sean lo suficientemente tolerantes a errores de montaje, seguimiento, temperatura y variaciones espectrales para que la energía que producen a lo largo del año sea máxima. Una de las primeras cuestiones que se abordan es el diseño de elementos ópticos secundarios para sistemas cuyo primario es una lente de Fresnel y que permiten, para una concentración fija, aumentar el ángulo de aceptancia y la tolerancia del sistema. Varios secundarios reflexivos y refractivos han sido diseñados y analizados mediante trazado de rayos. En particular, utilizando óptica anidólica y basándose en el diseño de una sola etapa conocido como ‘concentrador dieléctrico que funciona por reflexión total interna‘, se ha diseñado, fabricado y caracterizado un secundario con salida cuadrada que, usado junto con una lente de Fresnel, permite alcanzar simultáneamente una elevada eficiencia, concentración y aceptancia. Además, se ha propuesto y prototipado un método alternativo de fabricación para otro de los secundarios, denominado domo, consistente en el sobremoldeo de silicona sobre células solares. Una de las características que impregna todo el trabajo realizado en esta tesis es la aproximación holística en el diseño de módulos CPV, es decir, se ha prestado especial atención al diseño conjunto de la célula y la óptica para garantizar que el sistema total alcance la mayor eficiencia posible. En este sentido muchos sistemas ópticos desarrollados en esta tesis han sido diseñados, caracterizados y optimizados teniendo en cuenta que el ajuste de corriente entre las distintas subcélulas que comprenden la célula multiunión bajo el concentrador sea muy próximo a uno. La capa antirreflectante sobre la célula funciona, en cierto modo, como interfaz entre la óptica y la célula, por lo que se ha diseñado un método de optimización de capas antirreflectantes que considera no sólo el amplio rango de longitudes de onda para el que las células multiunión son sensibles sino también la distribución angular de intensidad sobre la célula creada por la óptica de concentración. Además, la cuestión de la falta de uniformidad también se ha abordado mediante la comparación de las distribuciones espectrales y espaciales de irradiancia que crean diferentes ópticas (simuladas mediante trazado de rayos y fotografiadas) y las pérdidas de eficiencia que experimentan las células iluminadas por dichas ópticas de concentración medidas experimentalmente. El efecto de la temperatura en la óptica de concentración también ha sido objeto de estudio de esta tesis. En particular, mediante simulaciones de elementos finitos se han dado los primeros pasos para el análisis de las deformaciones que sufren los dientes de las lentes de Fresnel híbridas (vidrio-silicona), así como el cambio de índice de refracción con la temperatura y la influencia de ambos efectos sobre el funcionamiento de los sistemas. Se ha implementado un modelo que tiene por objeto considerar las variaciones ambientales, principalmente temperatura y contenido espectral de la radiación directa, así como las sensibilidades térmica y espectral de los sistemas CPV, con el fin de maximizar la energía producida por un módulo de concentración a lo largo de un año en un emplazamiento determinado. Los capítulos 5 y 6 de este libro están dedicados al diseño, fabricación y caracterización de un nuevo concepto de módulo fotovoltaico denominado FluidReflex y basado en una única etapa reflexiva con dieléctrico fluido. En este nuevo concepto la presencia del fluido aporta algunas ventajas significativas como son: un aumento del producto concentración por aceptancia (CAP, en sus siglas en inglés) alcanzable al rodear la célula con un medio cuyo índice de refracción es mayor que uno, una mejora de la eficiencia óptica al disminuir las pérdidas por reflexión de Fresnel en varias interfaces, una mejora de la disipación térmica ya que el calor que se concentra junto a la célula se trasmite por convección natural y conducción en el fluido y un aislamiento eléctrico mejorado. Mediante la construcción y medida de varios prototipos de unidad elemental se ha demostrado que no existe ninguna razón fundamental que impida la implementación práctica del concepto teórico alcanzando una elevada eficiencia. Se ha realizado un análisis de fluidos candidatos probando la existencia de al menos dos de ellos que cumplen todos los requisitos (en particular el de estabilidad bajo condiciones de luz concentrada) para formar parte del sistema de concentración FluidReflex. Por ´ultimo, se han diseñado, fabricado y caracterizado varios prototipos preindustriales de módulos FluidReflex para lo cual ha sido necesario optimizar el proceso de fabricación de la óptica multicavidad a fin de mantener el buen comportamiento óptico obtenido en la fabricación de la unidad elemental. Los distintos prototipos han sido medidos, tanto en el laboratorio como bajo el sol real, analizando el ajuste de corriente de la célula iluminada por el concentrador FluidReflex bajo diferentes distribuciones espectrales de la radiación incidente así como el excelente comportamiento térmico del módulo. ABSTRACT A renewed interest in concentrating photovoltaic (CPV) systems has emerged in recent years encouraged by the development of high-efficiency multijunction solar cells based in IIIV semiconductors that have led to CPV module efficiencies which practically double that of flat panel PV and which reach 35% for record modules. This thesis is devoted to the design and experimental implementation of new concepts for obtaining CPV modules that not only achieve high efficiency under standard conditions but also have such a wide tolerance to assembly errors, tracking, temperature and spectral variations, that the energy generated by them throughout the year is maximized. One of the first addressed issues is the design of secondary optical elements whose primary optics is a Fresnel lens and which, for a fixed concentration, allow an increased acceptance angle and tolerance of the system. Several reflective and refractive secondaries have been designed and analyzed using ray tracing. In particular, using nonimaging optics and based on the single-stage design known as ‘dielectric totally internally reflecting concentrator’, a secondary with square output has been designed, fabricated and characterized. Used together with a Fresnel lens, the secondary can simultaneously achieve high efficiency, concentration and acceptance. Furthermore, an alternative method has been proposed and prototyped for the fabrication of the secondary named dome. The optics is manufactured by direct overmolding of silicone over the solar cells. One characteristic that permeates all the work done in this thesis is the holistic approach in the design of CPV modules, meaning that special attention has been paid to the joint design of the solar cell and the optics to ensure that the total system achieves the highest attainable efficiency. In this regard, many optical systems developed in the thesis have been designed, characterized and optimized considering that the current matching among the subcells within the multijunction solar cell beneath the optics must be close to one. Antireflective coating over the cell acts, somehow, as an interface between the optics and the cell. Consequently, a method has been designed to optimize antireflective coatings that takes into account not only the broad wavelength range that multijunction solar cells are sensitive to but also the angular intensity distribution created by the concentrating optics. In addition, the issue of non-uniformity has also been addressed by comparing the spectral and spatial distributions of irradiance created by different optics (simulated by ray tracing and photographed) and the efficiency losses experienced by cells illuminated by those concentrating optics experimentally determined. The effect of temperature on the concentrating optics has also been studied in this thesis. In particular, finite element simulations have been use to analyze the deformations experienced by the facets of hybrid (silicon-glass) Fresnel lenses, the change of refractive index with temperature and the influence of both effects on the system performance. A model has been implemented which take into consideration atmospheric variations, mainly temperature and spectral content of the direct normal irradiance, as well as thermal and spectral sensitivities of systems, with the aim of maximizing the energy harvested by a CPV module throughout the year in a particular location. Chapters 5 and 6 of this book are devoted to the design, fabrication, and characterization of a new concentrator concept named FluidReflex and based on a single-stage reflective optics with fluid dielectric. In this new concept, the presence of the fluid provides some significant advantages such as: an increased concentration acceptance angle product (CAP) achievable by surrounding the cell with a medium whose refractive index is greater than one, an improvement of the optical efficiency by reducing losses due to Fresnel reflection at several interfaces, an improvement in heat dissipation as the heat concentrated near the cell is transmitted by natural convection and conduction in the fluid, and an improved electrical insulation. By fabricating and characterizing several elementary-unit prototypes it was shown that there is no fundamental reason that prevents the practical implementation of this theoretical concept reaching high efficiency. Several fluid candidates were investigated proving the existence of at least to fluids that meet all the requirements (including the stability under concentrated light) to become part of the FluidReflex concentrator. Finally, several pre-industrial FluidReflex module prototypes have been designed and fabricated. An optimization process for the manufacturing of the multicavity optics was necessary to attain such an optics quality as the one achieved by the single unit. The module prototypes have been measured, both indoors and outdoors, analyzing the current matching of the solar cells beneath the concentrator for different spectral distribution of the incident irradiance. Additionally, the module showed an excellent thermal performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A conceptual energy storage system design that utilizes ultra high temperature phase change materials is presented. In this system, the energy is stored in the form of latent heat and converted to electricity upon demand by TPV (thermophotovoltaic) cells. Silicon is considered in this study as PCM (phase change material) due to its extremely high latent heat (1800 J/g or 500 Wh/kg), melting point (1410 C), thermal conductivity (~25 W/mK), low cost (less than $2/kg or $4/kWh) and abundance on earth. The proposed system enables an enormous thermal energy storage density of ~1 MWh/m3, which is 10e20 times higher than that of lead-acid batteries, 2e6 times than that of Li-ion batteries and 5e10 times than that of the current state of the art LHTES systems utilized in CSP (concentrated solar power) applications. The discharge efficiency of the system is ultimately determined by the TPV converter, which theoretically can exceed 50%. However, realistic discharge efficiencies utilizing single junction TPV cells are in the range of 20e45%, depending on the semiconductor bandgap and quality, and the photon recycling efficiency. This concept has the potential to achieve output electric energy densities in the range of 200-450 kWhe/m3, which is comparable to the best performing state of the art Lithium-ion batteries.