33 resultados para Grout (Mortar)

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to study the evolution of the corrosion rate of reinforcements embedded in mortar specimens that have been partly or fully replaced by the sand ladle furnace white slag. Prisms are manufactured mortar 6cm x 8cm x 2cm in which are embedded reinforcing steel bars of 6mm diameter B500SD. At the time of mixing were added varying amounts of chloride ion content by weight of cement (0%, 0.4%, 0.8%, 1.2%, 2%). The specimens were made totally or partially replacing the white slag, getting four different mixes depending on the degree of substitution. After curing the specimens for 28 days in moist chambers proceeded to dry up naturally. Here are gradually dampened by its conservation in a moist chamber, periodically measuring the corrosion rate of the bars using the technique of polarization curve. The results, in terms of corrosion current and corrosion potential, were compared with those obtained on standard samples, without replacement by slag aggregate. The analysis of results allows us to know, depending on the type of mortar used, the chloride threshold with the depassivation produced steel and the corrosion rates achieved in steels in the active state in terms of mortar moisture, obtained from qualitatively using gravimetric techniques. The results achieved to date support the conclusion that no significant differences in the behavior against corrosion induced by chloride ions, between the steel bars embedded in standard samples and the steel bars embedded in samples including with aggregates from slag. Both the chloride threshold resulting in the depassivation steel as the corrosion rate reached through the bars in an active state are very similar in both types of mortars when they have the same moisture content.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En la práctica habitual, para la elaboración de morteros se recomienda la utilización de granulometrías continuas. El requisito de continuidad y que los tamaños de partícula se encuentren dentro de los límites establecidos por “husos granulométricos” surge de las teorías clásicas de Fuller – Thompson y se apoya en la necesidad de obtener mezclas con adecuada docilidad en el estado fresco. Sin embargo, las distribuciones continuas de árido no representan las únicas alternativas para obtener mezclas que tengan una adecuada docilidad en estado fresco y mediante nuevos criterios de interferencia de partículas es posible demostrar que las distribuciones discontinuas aun siendo más compactas y con menor requerimientos de volumen de pasta pueden ser igual de dóciles en estado fresco. Aunque el volumen mínimo de pasta está condicionado por su fluidez y viscosidad estos parámetros pueden modificarse mediante la incorporación de filler de distinta naturaleza y aditivos químicos de reciente desarrollo. En consecuencia, se propone analizar la posibilidad de minimizar el contenido de pasta de morteros de base cemento, manteniendo las prestaciones en el estado fresco, con el objetivo de obtener una mejor estabilidad volumétrica, posibilitando mejor control de la retracción y de la fisuración. Para ello se emplearán criterios de interferencia de partículas, combinados con el uso de filler de distinta naturaleza La reducción del contenido de pasta conducirá también a mejorar el perfil sostenible de los morteros. El proceso de optimización tiene una base racional y, por lo tanto, será aplicable a distintos tipos de mortero, y las proporciones óptimas podrán adecuarse según las prestaciones requeridas para el material. SUMMARY In common practice, continuous sand gradings are recommended to produce ordinary mortars. This requirement, along with grading limits are based on classical theories, such as Fuller, aimed at achieving a reasonable packing density without compromising workability at the fresh state. Nevertheless, there are other alternatives, such as discontinuous curves based on particle interference criteria, which are capable of having even higher packing density. The less the content of voids in the granular skeleton, the less the amount of cement paste required to fill in these voids and coating the particles. Yet, the minimum volume of paste in a mortar is determined by requirements associated to the fresh state and thus, fluidity and viscosity of the paste play a significant role on the matter. These two properties can be modified by the use of suitable fillers and by the use of last-generation chemical admixtures. As a result, it is proposed to analyse the possibility of combining current particle interference criteria with the use of different types of filler and chemical admixtures to optimise cement-based mortar formulations. This optimisation is aimed at reducing the paste content while maintaining a suitable performance at the fresh state. The reduction in paste content would lead to a better dimensional stability, with better control of shrinkage and cracking behaviour. The foreseen optimisation process will have a strong rational basis and thus, it should be potentially useful to optimise mortar proportions according to a performance-based approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

GRC is a cementitious composite material made up of a cement mortar matrix and chopped glass fibers. Due to its outstanding mechanical properties, GRC has been widely used to produce cladding panels and some civil engineering elements. Impact failure of cladding panels made of GRC may occur during production if some tool falls onto the panel, due to stone or other objects impacting at low velocities or caused by debris projected after a blast. Impact failure of a front panel of a building may have not only an important economic value but also human lives may be at risk if broken pieces of the panel fall from the building to the pavement. Therefore, knowing GRC impact strength is necessary to prevent economic costs and putting human lives at risk. One-stage light gas gun is an impact test machine capable of testing different materials subjected to impact loads. An experimental program was carried out, testing GRC samples of five different formulations, commonly used in building industry. Steel spheres were shot at different velocities on square GRC samples. The residual velocity of the projectiles was obtained both using a high speed camera with multiframe exposure and measuring the projectile’s penetration depth in molding clay blocks. Tests were performed on young and artificially aged GRC samples to compare GRC’s behavior when subjected to high strain rates. Numerical simulations using a hydrocode were made to analyze which parameters are most important during an impact event. GRC impact strength was obtained from test results. Also, GRC’s embrittlement, caused by GRC aging, has no influence on GRC impact behavior due to the small size of the projectile. Also, glass fibers used in GRC production only maintain GRC panels’ integrity but have no influence on GRC’s impact strength. Numerical models have reproduced accurately impact tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental research has been performed to relate specific cement characteristics to deterioration due to sulfate and sea water attack after five year exposure, and to study different test method suitability for sulfate and marine resistance. Sulfate resistance testing have been performed on mortar specimens made with fifteen cement types of statistically diverse chemical composition according to European standard EN 197-1, most of them with sulfate resistant properties according to Spanish regulations. Chemical and mechanical characteristics were studied to determine the variation in properties of selected cements. SO3 content, type and amount of additions, C3A, and C4AF content were used to examine relationships between these characteristics and the results of sulfate resistance. Mortar specimens testing using Na2SO4 as the aggressive medium according to ASTM 1012 (with w/c ratio adapted to prENV 196-X:1995) was performed using each type of cement; identical specimens were also stored in sea water, and in lime saturated water (blank condition), up to five year age. Additionally these cements were tested conforming ASTM 452 and Koch and Steinegger test. Recommended acceptance limits for sulfate resistance of cements concerning to each used test method were evaluated in order to explore their suitability. Relationships between cement characteristics, degradation, expansive products obtained by X-ray diffraction techniques and maximum expansion after applied storage treatments, were correlated at final age, to redefine cement characteristics for sulfate resistant and marine resistant Portland cement

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plate-bandes are straight masonry arches (they are called, also, flat arches or lintel arches). Ideally they have the surfaces of extrados and intrados plane and horizontal. The stones or bricks have radial joints converging usually in one centre. The voussoirs have the form of wedges and in French they are called "claveaux". A plate-bande is, in fact, a lintel made of several stones and the proportions of lintels and plate-bandes are similar. Proportions of plate-bandes, that is the relationship between the thickness t and the span s (t/s)varies, typically between 1/4–1/3 in thick plate-bandes, and is less than 1/20 in the most slender ones. A ratio of circa 1/8 was usual in the 18th Century and follows a simple geometrical rule: the centre form with the intrados an equilateral triangle and the plate-bande should contain an arc of circle. The joints are usually plane, but in some cases present a «rebated» or «stepped» form. Plate-bandes exert an inclined thrust as any masonry arch. This thrust is usually very high and it requires either massive buttresses, or to be built in the middle of thick walls. Master builders and architects have tried since antiquity to calculate the abutment necessary for any arch. A modern architect or engineer will measure the arch thrust in units of force, kN or tons. Traditionally, the thrust has been measured as the size of the buttresses to resist it safely. Old structural rules, then, addressed the design problem establishing a relationship between the span and the depth of the buttress. These were empirical rules, particular for every type of arch or structure in every epoch. Thus, the typical gothic buttress is 1/4 of the vault span, but a Renaissance or baroque barrel vault will need more than 1/3 of the span. A plate-bande would require more than one half of the span; this is precisely the rule cited by the French engineer Gautier, who tried unsuccessfully to justify it by static reasons. They were used, typically, to form the lintels of windows or doors (1-2 m, typically); in Antiquity they were used, also, though rarely, at the gates of city walls or in niches (ca. 2 m, reaching 5.2 m). Plate-bandes may show particular problems: it is not unusual that some sliding of the voussoirs can be observed, particularly in thick plate-bandes. The stepped joints on Fig. 1, left, were used to avoid this problem. There are other «hidden» methods, like iron cramps or the use of stone wedges, etc. In seismic zones these devices were usual. Another problem relates to the deformation; a slight yielding of the abutments, or even the compression of the mortar joints, may lead to some cracking and the descent of the central keystone. Even a tiny descent will convert the original straight line of the intrados in a broken line with a visible «kink» or angle in the middle. Of course, both problems should be avoided. Finally, the wedge form of the voussoirs lead to acute angles in the stones and this can produce partial fractures; this occurs usually at the inferior border of the springers at the abutments. It follows, that to build a successful plate-bande is not an easy matter. Also, the structural study of plate-bandes is far from simple, and mechanics and geometry are related in a particular way. In the present paper we will concentrate on the structural aspects and their constructive consequences, with a historical approach. We will outline the development of structural analysis of plate-bandes from ca. 1700 until today. This brief history has a more than purely academic interest. Different approaches and theories pointed to particular problem, and though the solution given may have been incorrect, the question posed was often pertinent. The paper ends with the application of modern Limit Analysis of Masonry Structures, developed mainly by professor Heyman in the last fifty years. The work aims, also, to give some clues for the actual architect and engineer involved in the analysis or restoration of masonry buildings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de la presente tesis se enmarca dentro del estudio del estado de hormigones de presas, desarrollado en los últimos años en el Laboratorio Central del CEDEX, en el que se ratifica que una de las causas más importantes del deterioro de obras hidráulicas en España es la reacción álcali-sílice. La tesis que se presenta pretende contribuir al mejor conocimiento de la reacción álcali sílice con fines normativos preventivos, abordando los aspectos relativos a la identificación de áridos reactivos en el hormigón. El conocimiento de los áridos reactivos en España (origen de la reactividad, tipos de reacción y su comportamiento, así como las herramientas disponibles para su detección) es imprescindible para evitar la futura aparición de esta patología en nuevas estructuras, ya sea evitando el uso de áridos reactivos o tomando las medidas preventivas necesarias si su utilización es inevitable. A partir del Estudio Bibliográfico realizado se han detectado diversas lagunas en la identificación y caracterización de áridos de reacción rápida, cuya característica principal es que son reactivos con concentraciones muy bajas de diferentes componentes reactivos. Para resolver las lagunas identificadas se ha planeado un estudio experimental, consistente en el análisis de áridos cuya reactividad es conocida porque han sido empleados en obras afectadas por la reacción álcali sílice. Sobre el árido grueso extraído de estas estructuras se han realizado una serie de ensayos normalizados (estudio petrográfico, ensayo acelerado de probetas de mortero, ensayo Gel Pat y ensayos químicos). El análisis de los resultados experimentales ha permitido conocer las limitaciones reales en áridos reactivos españoles de las diferentes técnicas existentes, tratando de minimizarlas para áridos cuya reactividad es debida a componentes minoritarios (áridos de reacción rápida). Además, se ha evaluado la utilización de la difracción de rayos X (no normalizada) y la creación de un nuevo ensayo (Gel Pat Modificado). Finalmente, el estudio experimental ha permitido fijar una metodología de ensayo para el estudio de áridos reactivos por su contenido en componentes minoritarios (áridos de reacción rápida). The objective of this Thesis fits into the research program developed in CEDEX the last years and focused on the durability of concrete in Dams. This research work confirms that one of the main problems related to the deterioration of hydraulic structures is the alkali silica reaction. This Thesis aims to contribute to a better understanding of alkali-silica reaction, for preventive regulation purposes, considering the aspects related to the identification of reactive aggregates. The knowledge of Spanish reactive aggregates (origin of the reactivity, types of reaction and their behavior, and the tools available to detect and describe them) is essential to avoid the appearance of this pathology in new structures, either not using the reactive aggregate or taking the necessary preventive measures available in bibliography if the use of the reactive aggregate is inevitable. From the State-of –the-Art developed, several gaps have been detected in the detection and description of rapid reactive aggregates, which main characteristic if that they are reactive with low content of some reactive components. An experimental programme has been designed to solve these gaps, consisting on studying the reactivity of aggregates used in Spanish structures affected by the alkali silica reaction. Several Standard Tests have been carried out on coarse aggregates removed from the affected structures (Petrographic description, Accelerated Mortar Bar Test, Gel Pat Test and Chemical Tests). The analysis of the results obtained in Spanish reactive aggregates allows to know the advantages and limitations of each test, trying to minimize the disadvantages to detect Spanish reactive aggregates because of the minority content of rapid reactive components (rapid reactive aggregates). Moreover, X ray diffraction (not standardized) has been tested to detect rapid reactive aggregates and also a new test has been developed for the same purpose (Optimized Gel Pat Test). Finally, the experimental programme has made possible to define a methodology for detection of Spanish rapid reactive aggregates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this project is to show that the permissible explosive called 20 SR is able to pull out the coal in the normal conditions of blasting in a satisfactory way and to set up the equivalence between the 20 SR and gelatin dynamite (Goma 2 ECO). To achieve this goal some blasting were done, changing the conditions of the blasting and the powder factor for the 20 SR. To analyze the fragmentation base on the analysis of the images of the rock blasted, a commercial software was used. The results from this analysis were compared with the results from the theoretical model for fragmentation created by Kuz – Ram. After all, it was showed that the 20 SR explosive is able to pull out the coal for different coal rock compositions. As the result of this project we can conclude that the 20 SR seems to be able to pull out the coal in normal blasting conditions, using the powder factor as a proportion of the “ballistic mortar” between the two explosives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El hormigón armado es el material estructural más empleado en construcción, lo que exige un exhaustivo control tanto de los materiales que lo componen como de su ejecución, con el fin de garantizar la vida útil para la que ha sido proyectado. Uno de los principales problemas de la durabilidad del hormigón armado, es la corrosión de sus armaduras. Existen en la actualidad diferentes métodos que intentan detener el proceso de corrosión, entre ellos, los inhibidores superficiales de corrosión. El continuo incremento en la producción de acero desde el siglo XIX, ha producido un desequilibrio entre los productos fabricados en las industrias siderúrgicas y los residuos generados. Como consecuencia, toneladas de residuos son depositados en vertederos, provocando graves daños medioambientales con el paso del tiempo. El volumen de escorias producidas en la industria siderúrgica en España asciende a 2,55Mt al año, de ahí la importancia del reciclaje de estos productos y de su integración como materia prima en el proceso de fabricación de otros materiales. Partiendo de estas premisas, en el presente trabajo de investigación se ha estudiado el comportamiento a corrosión, de barras de acero de armar embebidas en probetas de mortero, en las que se ha sustituido parcialmente el árido y el cemento por escorias blancas de horno cuchara (LFS), mediante técnicas electroquímicas y gravimétricas. Para ello, se han fabricado probetas prismáticas de 6 x 8 x 2 cm3 con diferentes porcentajes de ión cloruro, introducidos en el momento del amasado, tanto en probetas patrón como en probetas con escorias LFS. El análisis de los resultados obtenidos permite concluir que las probetas patrón y las probetas con escorias LFS tienen comportamientos similares en presencia de cloruros por encima del 0,4% en peso de cemento y por tanto que la sustitución de escorias LFS por arena (25%) y cemento (30%) no afecta negativamente a la corrosión de las armaduras. Por tanto, el uso de escorias LFS en el proceso de fabricación de hormigón armado es una práctica que presenta ventajas competitivas respecto a las técnicas de construcción tradicionales, desde el punto de vista económico y medioambiental. En cuanto a los inhibidores superficiales de corrosión, no han resultado eficaces en probetas con escorias LFS, independientemente del porcentaje de ión cloruro, mientras que en probetas patrón han sido eficaces para porcentajes de ión cloruro igual o inferior al 0,8% en peso de cemento. ABSTRACT Reinforced concrete is the most widely used structural material. This implies that rigorous control must be applied in order to guarantee the life-span and performance of structures made using this composite material. One of the main problems regarding concrete durability is bar corrosion. At present, there are different methods adopted to stop the corrosion process, among them, surface corrosion inhibitors. The continuous growth in steel production since the 19th century has led to an imbalance between waste products generated in steel production processes and their subsequent use. As a consequence, mass dumping at waste disposal sites has been causing a significant environmental problem over the years. The amount of slag produced by the steel industry each year in Spain amounts to 2.55Mt, hence the importance of recycling by-products from steel production so they can be used as primary material in the manufacturing process of other materials. Starting from this working hypothesis, and using electrochemical and gravimetric techniques, this research work aims to analyse and study the corrosion behaviour of steel rebars embedded in mortar specimens, containing ladle furnace slag in partial substitution for aggregate and cement. Prisms were manufactured from 6 x 8 x 2 cm3 with different percentages of chloride ion introduced at the time of mixing, in standard specimens and specimens with LFS slag. Results from the analysis show that the standard specimens and those containing LFS slag display a similar behaviour in the presence of chlorides. Furthermore, when LFS slag is replaced by sand (25%) and cement (30%) corrosion of rebars is not negatively affected. Additionally, the use of LFS slag in the manufacture of reinforced structures is a practice that represents a competitive advantage over traditional construction techniques, from both an economic and environmental point of view Finally, as for surface corrosion inhibitors, they have not proved effective in specimens containing LFS slag, regardless of the percentage of the chloride ion, whereas in standard specimens they have been effective in chloride ion percentages not exceeding 0.8% (as to the cement amount).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La durabilidad de las estructuras de hormigón armado no es ilimitada, en especial en determinados ambientes. El ingreso de agentes agresivos en el hormigón, fundamentalmente dióxido de carbono e iones cloruros, rebasando el espesor del recubrimiento y alcanzando las armaduras, reducen el alto pH del hormigón hasta alcanzar un umbral crítico, por debajo del cual, el acero queda despasivado. Posteriormente, si existe el suficiente aporte de humedad y oxígeno, el acero se corroe, lo que supone drásticas reducciones de la vida de servicio de estas estructuras y su inevitable reparación. La utilización de armaduras de acero inoxidable es una alternativa que está recibiendo cada vez más consideración. Su resistencia a la corrosión en los ambientes más agresivos, incluso con ataque de cloruros, lo convierte en el material idóneo para prolongar de forma muy considerable la vida útil de la estructura. En este trabajo se ha evaluado el comportamiento mecánico y estructural, y de resistencia a la corrosión, de un nuevo acero inoxidable dúplex de bajo contenido en níquel, el EN 1.4482 (AISI 2001), y se ha comparado con el inoxidable austenítico más utilizado, el EN 1.4301 (AISI 304), con el dúplex EN 1.4362 (AISI 2304) y con el tradicional acero al carbono B-500-SD. El estudio mecánico y estructural se ha realizado en tres niveles diferentes: a nivel de barra, estudiando las propiedades mecánicas y de ductilidad de los cuatro aceros citados; a nivel de sección, estudiando su comportamiento a flexión con diferentes cuantías de armado por medio de los diagramas momento-curvatura; y a nivel de pieza, ensayando una serie de vigas armadas con diferentes aceros y cuantías, y comprobando su comportamiento a desplazamiento y resistencia por medio de los diagramas carga-desplazamiento. El estudio de resistencia a la corrosión se ha realizado embebiendo barras corrugadas, de los tres aceros inoxidables mencionados, en probetas de mortero contaminadas con diferentes cantidades de cloruros, y realizando mediciones electroquímicas durante un periodo de al menos un año. Se han preparado probetas de mortero para dos comparativas diferentes. La primera, manteniendo las probetas en un desecador con el 95 % de humedad relativa durante todo el periodo de mediciones. La segunda, sumergiendo parcialmente las probetas en una solución tampón para carbonatar el mortero. Los resultados de los ensayos mecánicos han demostrado dos aspectos diferentes. Uno, que las armaduras de acero inoxidable tienen un comportamiento muy similar a las de acero al carbono en lo referente a las resistencias alcanzadas, en el límite elástico y en rotura, pero distinto en cuanto al módulo de deformación longitudinal, cuyo valor es claramente inferior al del acero al carbono, por lo que su utilización en las estructuras de hormigón necesita tener en cuenta ese dato en los análisis lineales de cálculo. El segundo aspecto es que las armaduras de acero inoxidable laminadas en caliente presentan una ductilidad muy superior a las de acero al carbono, por lo que ofrecen una mayor seguridad frente a su rotura o al colapso de la estructura, lo que se debe tener en cuenta en el análisis de cálculo plástico. En cambio, las armaduras de acero inoxidable laminadas en frío sólo cumplen con los límites mínimos de ductilidad establecidos en la instrucción EHE-08 para los aceros soldables, y no para los aceros con características especiales de ductilidad. El estudio a nivel de sección refleja la paradoja de obtener secciones menos dúctiles con las armaduras de acero inoxidable laminadas en caliente que con las armaduras de acero al carbono. Para subsanarlo, se definen los conceptos de curvatura última de rotura y ductilidad de la sección en rotura, que tienen en cuenta las altas deformaciones alcanzadas por las armaduras de acero inoxidable. Los resultados a nivel de pieza permiten identificar el comportamiento estructural del hormigón armado con barras corrugadas de acero inoxidable y compararlo con el de las estructuras de hormigón armado convencionales, verificando los resultados experimentales con los teóricos obtenidos con la formulación recogida en la instrucción EHE- 08. Los ensayos de resistencia a la corrosión por cloruros demuestran, durante el primer año y medio de vida de las probetas, un comportamiento muy similar entre el nuevo acero inoxidable dúplex bajo en níquel y el austenítico y el dúplex utilizados para la comparación, incluso para las probetas carbonatadas. Por último, se añade una comparativa económica, realizada sobre dos edificaciones tipo, para cuantificar el sobrecoste que supone la utilización de armaduras de acero inoxidable respecto a las de acero al carbono. El alto coste inicial de las armaduras de acero inoxidable se ve compensado en el coste final de la estructura de muy diferentes formas, principalmente dependiendo del grado de acero elegido y de si se emplean en el total de la estructura o solamente en los elementos más expuestos. The durability of the concrete structures is limited, especially in certain environments. The attack of aggressive agents in the concrete, mainly carbon dioxide and chloride ions, penetrating the thickness of concrete cover and reaching the reinforcements, reduce the high pH of concrete to the point of reaching a critical threshold, under which, the steel despasivates. Therefore, if there is enough humidity and oxygen, the steel corroes, causing drastic reductions in the service life of these structures and its inevitable repair. Despite the high initial cost compared to carbon steel, the usage of stainless steel reinforcements is an alternative with a major consideration nowadays. Its resistance to corrosion in the most aggressive atmospheres, including chlorides attack, makes the stainless steel a suitable material to extend considerably its lifetime. In this study, it’s been evaluated the mechanical and structural behaviour, and the corrosion resistance, of a new low-nickel duplex stainless steel EN 1.4482 (AISI 2001), and it has been compared with the most widely used austenitic type EN 1.4301 (AISI 304), with duplex steel EN 1.4362 (AISI 2304) and with the traditional carbon steel B-500-SD. The mechanical and structural study has been carried out in three different levels: bar level, studying mechanical properties and ductility of the four steels; section level, studying its behaviour when blending with different amounts of reinforcement through the moment-curvature diagrams; and structural element level, testing a series of reinforced beams with different steels and amounts, and checking its sag and resistance through the load-deflection diagrams. The corrosion resistance study was performed by embedding ribbed bars, using the three stainless steel listed, on mortar specimens contaminated with different amounts of chlorides, and taking electrochemical measurements over a period of at least one year. Mortar specimens have been prepared for two different comparisons. The first, keeping the specimens at 95% of relative humidity during the measurement period. The second, immersing the specimens partially in a carbonate buffer solution. The results of those tests have proved two different aspects. Firstly, that stainless steel reinforcements show a very similar behaviour to carbon steel, according to the reached levels of mechanical resistance, yield stress and steel strength, but a different behaviour in Young’s modulus, which value is clearly lower than the carbon steel. Therefore, when using in concrete structures it is need to consider on that point the existing calculus of linear analysis. The second aspect is that stainless steel reinforcement manufactured by hot-rolling process show a very higher ductility than carbon steel, offering a better security on cracks or structure collapse, which it has to be taken into account on plastic calculus analysis. However, the stainless steel reinfor9 cement cold-rolled bars only meet the minimum thresholds of ductility established by EHE-08 for welded steel, and not for steels with special ductility. The results at the section level reflect the paradox of getting less ductile sections with hot rolled stainless steel reinforcement than with carbon steel reinforcements. To overcome that, the concepts of last break curvature and break ductility section have been defined, which take into account the high deformation value achieved by stainless steel reinforcements. The results at the structural element level allow to identify the structural behaviour of reinforced concrete with stainless steel reinforcements and compared with that of conventional steel reinforcement, contrasting the experimental with the theoretical results obtained from the formulation contained in the instruction EHE-08. Tests on resistance of chloride corrosion show during the first year and a half of specimens life, a similar behaviour between the new low nickel duplex stainless steel and austenitic and duplex used for comparison, even for carbonated specimens. Finally, it has been included an economic comparison on two differents building types, to quantify the additional cost involved on the use of stainless steel reinforcement compared to that of carbon steel. The high initial cost of stainless steel reinforcements is offset in the final cost of the structure in many different ways, mainly depending on the chosen steel grade and whether the reinforcement is used in the total structure or only in risky structural elements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente proyecto pretende demostrar que el explosivo de seguridad 20 SR es capaz de arrancar el carbón de forma satisfactoria en las condiciones de disparo habituales y establecer la equivalencia práctica de dicho explosivo con una dinamita gelatinosa (Goma 2ECO). Para conseguir este objetivo se realizaron una serie de voladuras, variando las condiciones de disparo y los consumos específicos de la dinamita de seguridad. Se utilizó un software de análisis fotográfico para el estudio de la fragmentación en la pila y también se compararon los resultados obtenidos con el modelo teórico de fragmentación de Kuz – Ram. Los resultados demostraron la capacidad de arranque de la dinamita de seguridad, para diferentes composiciones de carbón. Del estudio parece deducirse que la dinamita de seguridad 20 SR es capaz de arrancar el carbón en condiciones de disparo habituales utilizando un consumo específico proporcional a la relación de la potencia del péndulo balístico de ambos explosivos. ABSTRACT The objective of this project is to show that the permissible explosive called 20 SR is able to pull out the coal in the normal conditions of blasting in a satisfactory way and to set up the equivalence between the 20 SR and gelatin dynamite (Goma 2 ECO). To achieve this goal some blasting were done, changing the conditions of the blasting and the powder factor for the 20 SR. To analyze the fragmentation base on the analysis of the images of the rock blasted, a commercial software was used. The results from this analysis were compared with the results from the theoretical model for fragmentation created by Kuz – Ram. After all, it was showed that the 20 SR explosive is able to pull out the coal for different coal rock compositions. As the result of this project we can conclude that the 20 SR seems to be able to pull out the coal in normal blasting conditions, using the powder factor as a proportion of the “ballistic mortar” between the two explosives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cemeteries are part of the cultural heritage of urban communities, containing funerary crypts and monuments of historical and architectural interest. Efforts aimed at the conservation of these structures must target not only the abiotic stresses that cause their destruction, such as light and humidity, but also biofouling by biotic agents. The purpose of this study was to assess the development of biofouling of several historically and architecturally valuable crypts at La Plata Cemetery (Argentina). Samples obtained from the biofilms, lichens, and fungal colonies that had developed on the marble surfaces and cement mortar of these crypts were analyzed by conventional microbiological techniques and by scanning electron microscopy. The lichens were identified as Caloplaca austrocitrina, Lecanora albescens, Xanthoparmelia farinosa and Xanthoria candelaria, the fungi as Aspergillus sp., Penicillium sp., Fusarium sp., Candida sp. and Rhodotorula sp., and the bacteria as Bacillus sp. and Pseudomonas sp. The mechanisms by which these microorganisms cause the aesthetic and biochemical deterioration of the crypts are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

EEn este proyecto se propone un método de ensayo experimental adecuado para diferenciar los morteros de yeso respecto de los de yeso y cal, estableciendo su porcentaje de Ca(OH)2. Se han empleado 3 métodos de ensayo diferentes, siendo el más adecuado el método de determinación del hidróxido de calcio para cales de construcción, contemplado en la norma española UNE-EN 459-2:2010, aunque se han añadido modificaciones para mejorar su aplicabilidad. El método de ensayo experimental propuesto permite calcular el contenido de hidróxido de calcio en porcentaje. ABSTRACT The objective of this project is to find a method from differentiate plaster mortar or lime and plaster mortar, since currently there is not any method to determine this difference. Then, normative methods used on other construction products are analyzed for prove their sensibility to determinate calcium hydroxide, evaluating its repeatability with the existing normative. Too, is evaluating alteration in the method of determination calcium sulfate by adding to the slaked lime, key component in the hydratation of plaster. Following with this work, it is waiting the modification of existing regulation in material plaster. Proposed method, must be approved for prescribers, manufacturers and final clients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objeto del proyecto es determinar los métodos estadísticos adecuados para la evaluación de los resultados de un ejercicio de intercomparación entre laboratorios para ensayos de aptitud de áridos para hormigón, mortero y balasto. Los ensayos estudiados son los aludidos en la norma UNE-EN 12620:2002 de áridos para hormigón, UNE-EN 13139:2003 para mortero, y UNE-EN 13450:2003 para balasto, que pueden clasificarse según las propiedades a determinar: - Geométricas - Mecánicas y Físicas - Térmicas y de Alteración - Químicas Los criterios aplicables para el desarrollo de los trabajos son los exigidos por la Entidad Nacional de Acreditación (ENAC) para laboratorios acreditados conforme a la Norma UNE-EN ISO/IEC 17025 y para proveedores acreditados conforme a la Norma UNE-EN ISO/IEC 17043. ABSTRACT The purpose of the project is to determine the appropriate statistical methods to evaluate the results of an intercomparison exercise among laboratories for proficiency testing of aggregates for concrete, mortar and ballast. The studied assays are mentioned in the UNE-EN 12620:2002 standard of aggregates for concrete, UNE-EN 13139:2003 for mortar, and UNE-EN 13450:2003 for ballast, which can be classified according to the properties to determine: - Geometric - Mechanical and Physical - Thermal and Alteration - Chemical The criteria for the development of the work are those required by the National Accreditation Body (ENAC) for laboratories accredited according to the UNE-EN ISO / IEC 17025 and for suppliers according to the UNE-EN ISO / IEC 17043.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta Tesis plantea la pregunta de si el uso de morteros con parafinas microencapsuladas combinado con colectores solares térmicos puede reducir el consumo de energías convencionales, en un sistema tradicional de suelo radiante. Se pretende contribuir al conocimiento acerca del efecto que produce en el edificio, el calor latente acumulado en suelos radiantes, utilizando morteros de cemento Portland con material de cambio de fase (PCM), en conjunto con la energía solar. Para cumplir con este propósito, la investigación se desarrolla considerando diversos aspectos. En primer lugar, se revisa y analiza la documentación disponible en la actualidad, de almacenamiento de energía mediante calor latente en la construcción, y en particular la aplicación de microcápsulas de PCM en morteros y suelos radiantes. También se revisa la documentación relacionada con la aplicación de la energía solar térmica y en suelo radiante. Se analiza la normativa vigente respecto al material, a los colectores solares y al suelo radiante. Se verifica que no hay normativa relacionada con mortero-PCM, debido a esto se aplica en la investigación una adaptación de la existente. La fase experimental desarrollada esta principalmente dirigida a la cuantificación, caracterización y evaluación de las propiedades físicas, mecánicas y térmicas del mortero de cemento Portland con parafinas microencapsuladas. Los resultados obtenidos y su análisis, permiten conocer el comportamiento de este tipo de morteros, con las diferentes variables aplicadas en la investigación. Además, permite disponer de la información necesaria, para crear una metodología para el diseño de morteros con parafina microencapsulada, tanto del punto de vista de su resistencia a la compresión y contenido de PCM, como de su comportamiento térmico como acumulador de calor. Esto se logra procesando la información obtenida y generando modelos matemáticos, para dosificar mezclas, y predecir la acumulación de calor en función de su composición. Se determinan los tipos y cantidades de PCM, y el cemento más adecuado. Se obtienen importantes conclusiones respecto a los aspectos constructivos a considerar en la aplicación de morteros con PCM, en suelo radiante. Se analiza y evalúa la demanda térmica que se puede cubrir con el suelo radiante, utilizando morteros con parafina microencapsulada, a través de la acumulación de energía solar producida por colectores solares, para condiciones climáticas, técnicas y tipologías constructivas específicas. Se determina que cuando los paneles cubren más de 60 % de la demanda por calefacción, se puede almacenar en los morteros con PCM, el excedente generado durante el día. Se puede cubrir la demanda de acumulación de energía con los morteros con PCM, en la mayoría de los casos analizados. Con esto, se determina que el uso de morteros con PCM, aporta a la eficiencia energética de los edificios, disminuyendo el consumo de energías convencionales, reemplazándola por energía solar térmica. En esta investigación, el énfasis está en las propiedades del material mortero de cemento-PCM y en poder generar metodologías que faciliten su uso. Se aborda el uso de la energía solar, para verificar que es posible su acumulación en morteros con PCM aplicados en suelo radiante, posibilitando el reemplazo de energías convencionales. Quedan algunos aspectos de la aplicación de energía solar a suelo radiante con morteros con PCM, que no han sido tratados con la profundidad que requieren, y que resultan interesantes de evaluar en este tipo de aplicaciones constructivas, como entre otros, los relacionados con la cuantificación de los ahorros de energía en las diferentes estaciones del año, de la estabilización de temperaturas internas, su análisis de costo y la optimización de este tipo de sistemas para utilización en verano, los que dan pie para otras Tesis o proyectos de investigación. ABSTRACT This Thesis proposes the question of whether the use of mortars with microencapsulated paraffin combined with solar thermal collectors can reduce conventional energy consumption in a traditional heating floor system. It aims to contribute to knowledge about the effect that it has on the building, the latent heat accumulated in heating floor, using Portland cement mortars with phase change material (PCM), in conjunction with solar energy. To fulfill this purpose, the research develops it considering various aspects. First, it reviews and analyzes the documentation available today, about energy storage by latent heat in the building, and in particular the application of PCM microcapsules in mortars and heating floors. It also reviews the documentation related to the application of solar thermal energy and heating floor. Additionally, it analyzes the current regulations regarding to material, solar collectors and heating floors. It verifies that there aren’t regulations related to PCM mortar, due to this, it applies an adaptation in the investigation. The experimental phase is aimed to the quantification, mainly, characterization and evaluation of physical, mechanical and thermal properties of Portland cement mortar with microencapsulated paraffin. The results and analysis, which allow us to know the behavior of this type of mortars with different variables applied in research. It also allows having the information necessary to create a methodology for designing mortars with microencapsulated paraffin, both from the standpoint of its resistance to compression and PCM content, and its thermal performance as a heat accumulator. This accomplishes by processing the information obtained, and generating mathematical models for dosing mixtures, and predicting heat accumulation depending on their composition. The research determines the kinds and amounts of PCM, and the most suitable cement. Relevant conclusions obtain it regarding constructive aspects to consider in the implementation of PCM mortars in heating floor. Also, it analyzes and evaluates the thermal demand that it can be covered in heating floor using microencapsulated paraffin mortars, through the accumulation of solar energy produced by solar collectors to weather conditions, technical and specific building typologies. It determines that if the panels cover more than 60% of the demand for heating, the surplus generated during the day can be stored in PCM mortars. It meets the demand of energy storage with PCM mortars, in most of the cases analyzed. With this, it determines that the use of PCM mortars contributes to building energy efficiency, reducing consumption of conventional energy, replacing it with solar thermal energy. In this research approaches the use of solar energy to determine that it’s possible to verify its accumulation in PCM mortars applied in heating floor, enabling the replacement of conventional energy. The emphasis is on material properties of PCM mortar and, in order to generate methodologies to facilitate their use. There are some aspects of solar energy application in PCM mortars in heating floor, which have not been discussed with the depth required, and that they are relevant to evaluate in this kind of construction applications, including among others: the applications related to the energy savings quantification in different seasons of the year, the stabilizing internal temperatures, its cost analysis and optimization of these systems for use in summer, which can give ideas for other thesis or research projects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La tesis doctoral desarrolla una investigación original, dentro del marco disciplinario de la historia de la construcción, sobre los fundamentos constructivos de las fortificaciones bajomedievales fronterizas entre las Coronas de Castilla y Aragón en la actual provincia de Soria. En el título de la tesis ya queda expresado el objeto fundamental y fundacional, así como el ámbito temporal —desde la reconquista del oriente soriano por parte de Alfonso I el Batallador a principios del siglo XII hasta la unificación de las coronas hispánicas en el siglo XV bajo el común mandato de los Reyes Católicos— y la extensión territorial que delimita la investigación: aquéllas comarcas castellanas lindantes con Aragón pertenecientes a la actual provincia de Soria. Durante este período bajomedieval se produjeron una serie de enfrentamientos fronterizos que obligó a fortificar la frontera y las vías de comunicación entre ambas coronas. La falta de estudios de conjunto de estas fortificaciones entendiéndolas como participantes en un sistema fortificado ha constituido la justificación de la investigación, que se realiza en varios niveles de análisis: territorial, histórico, arquitectónico, poliorcético y constructivo. Así mismo, se ha detectado cierta falta de rigor acompañada de inexactitudes en las consideraciones constructivas publicadas sobre algunas de las fortificaciones del ámbito de estudio, lo que ha provocado errores en su datación al no más haber elementos de corte artístico o estilístico que marquen indudablemente la pertenencia a una época. En la tesis se ponen en duda las dataciones tradicionalmente aceptadas planteando la hipótesis que da pie a la investigación: ante la falta de elementos artísticos o estilísticos en unos sobrios edificios eminentemente funcionales es posible establecer con suficiente aproximación la fecha de construcción en base a criterios constructivos una vez formada una clasificación cronotipológica de cada técnica constructiva. La hipótesis, por lo tanto, plantea un objetivo principal —el estudio de la razón constructiva del sistema fortificado fronterizo— desarrollado en una serie de objetivos específicos cuya consecución programa los sucesivos niveles de análisis: - Conocer y detallar los elementos históricos que originaron los enfrentamientos entre las Coronas de Castilla y Aragón y su desarrollo mediante herramientas historiográficas y analizar las características naturales del territorio en litigio mediante instrumentos cartográficos. - Conocer y analizar los tipos arquitectónicos y las tradiciones constructivas empleadas en las construcciones castrenses en el ámbito temporal en que se enmarca la investigación. - Localizar, documentar y seleccionar para su análisis las fortalezas y construcciones militares erigidas durante dichas luchas fronterizas en la actual provincia de Soria a través del trabajo de campo y métodos cartográficos y bibliográficos. - Realizar un estudio general sobre el sistema fortificado a escala territorial - Investigar la tipología arquitectónica, poliorcética y constructiva del conjunto de estas fortificaciones bajomedievales fronterizas. - Analizar los fundamentos constructivos de los casos de estudio seleccionados entre estas construcciones y caracterizarlas en cuanto al material, elementos, sistemas y procesos constructivos. - Ordenar la información histórica dispersa y corregir errores para hacer una base sobre la que establecer un discurso histórico de cada caso de estudio. - Comparar y relacionar las técnicas constructivas empleadas en estas fortalezas con los utilizados en el mismo ámbito temporal. - Difundir para su debate los resultados de la investigación por los foros científicos habituales. El método empleado combina los trabajos de gabinete con una intensa labor de campo, en la que se han documentado cincuenta fortificaciones y se han redactado sus correspondientes fichas de toma de datos. La recopilación de datos se ha incluido en una base de datos que incluye aspectos generales, tipológicos, constructivos y bibliográficos básicos del conjunto, a modo de inventario, de fortificaciones de la provincia. Las fortificaciones seleccionadas se agrupan según una clasificación tipológica y constructiva que marca las líneas de estudio posteriores. Se desarrolla un capítulo de antecedentes en el que se estudia la historia de la construcción fortificada medieval tanto en Europa como en España analizando la evolución de los tipos arquitectónicos y las múltiples influencias culturales que surcaron el Mediterráneo desde el Oriente cruzado e islámico al Poniente donde se desarrollaba la empresa reconquistadora que mantuvo en estado de guerra continuo a la Península Ibérica durante ochocientos años. El análisis del territorio como contenedor del hecho fortificado revela que hay una relación íntima entre la ubicación de las fortificaciones y las formas naturales que definen las vías de comunicación entre los valles del Duero, del Ebro y del Tajo. En efecto, el ámbito de estudio ha supuesto desde la Antigüedad un territorio de paso fundamental en la articulación de las comunicaciones en la Península Ibérica. Este carácter de paso más que de frontera explica las inquietudes y la preocupación por su control tanto por Roma como por el califato cordobés como por los reinos cristianos medievales. El análisis de los elementos históricos se complementa con el estudio detallado de los enfrentamientos fronterizos entre Castilla y Aragón así como los aspectos sociales y políticos que provocaron la fortificación como sistema de definición de la frontera y de organización espacial, jurisdiccional, social y administrativa del territorio. La arquitectura fortificada es esencialmente funcional: su cometido es la defensa. En este sentido, tras un estudio morfológico de los castillos seleccionados se realiza un extenso análisis poliorcético de sus elementos, investigando su origen y aplicación para servir también de parámetros de datación. Siendo el objeto inaugural de la tesis el estudio de los fundamentos constructivos, se explican los distintos materiales de construcción empleados y se agrupan las fábricas de las fortificaciones seleccionadas en dos grandes grupos constructivos: las fábricas aparejadas y las fábricas encofradas. Se han destacado y estudiado la evolución histórica y la tipología y mensiología constructiva de tres técnicas destacadas: el uso del ladrillo, la tapia de cal y canto o mampostería encofrada y la tapia de tierra. Para el estudio de la componente histórica y de la dimensión constructiva de cada técnica ha sido necesario documentar numerosos casos tanto en el ámbito de estudio como en la Península Ibérica con el fin de establecer grupos cronotipológicos constructivos entre los que poder ubicar las fábricas de estas técnicas presentes en el ámbito de estudio. Se ha observado una evolución dimensional de las fábricas de tapia que es más evidente en las hispanomusulmanas al modularse en codos pero que también se advierte significativamente en las cristianas bajomedievales. De cada una de las técnicas analizadas se ha seleccionado un caso de estudio singular y representativo. El castillo de Arcos de Jalón es un ejemplo significativo del empleo de la fábrica mixta de mampostería con verdugadas de ladrillo, así como las murallas de la ciudad fortificada de Peñalcázar lo es de la fábrica de mampostería encofrada y el castillo de Serón de Nágima constituye un caso característico y principal de la utilización de la tapia de tierra en la arquitectura militar bajomedieval. Cada uno de estos tres casos de estudios se examina bajo los mismos cuatro niveles anteriormente mencionados: territorial, histórico, arquitectónico y defensivo y constructivo. El sistemático método de estudio ha facilitado el orden en la investigación y la obtención de unos resultados y conclusiones que verifican la hipótesis y cumplen los objetivos marcados al comienzo. Se ha revisado la datación en la construcción de las fortificaciones analizadas mediante el estudio cronotipológico de sus fábricas, pudiendo trasladarse el método a otros sistemas fortificados. La tesis abre, finalmente, dos vías principales de investigación encaminadas a completar el estudio del sistema fortificado fronterizo bajomedieval en la raya oriental soriana de Castilla: la caracterización y datación por métodos físico-químicos de las muestras de piezas de madera de construcción que se conservan embebidas en las fábricas y la búsqueda documental y archivística que pueda revelar nuevos datos respecto a la fundación, reparación, venta o cualquier aspecto económico, legislativo, organizativo o administrativo relativo a las fortificaciones en documentos coetáneos. ABSTRACT The doctoral thesis develops an original research, held in the field of the Construction History, about the constructive reason of the frontier fortifications in the Late Middle Age between the Crowns of Castile and Aragón in the actual province of Soria, Spain. In the title is expressed the main objective, and also the temporal scope —from the reconquest in the 12th Century by Alfonso the First of Aragón to the unification under the common kingdom of the Catholic Kings— and the territorial extension that the research delimits: those Castilian regions in the border with Aragón in the actual province of Soria. During this period, a series of border wars were been, and this is the reason for the fortification of the border line and the main roads between both Crowns. The lack of studies of these fortifications as participants in a fortified system is the justification of the research. There is several analysis levels: territorial, historical, architectonic, defensive and constructive. Likewise, there is a lack of strictness and inaccuracy in the constructive items in the publications about several fortifications of this study field. This aspect has caused mistakes in the dating because there is neither artistic nor stylistic elements which determines a epoch. The traditionally accepted datings are challenged. An hypothesis is formulated: in the absence of artistic or stylistic elements in a sober and functional buildings is possible to date the time of construction with sufficiently approximation based on construction criteria once formed a cronotypologic classification of each building technique. The hypothesis, therefore, propose a main aim: the study of the constructive reason of the fortified border system. This aim is developed in a series of specifically targets whose achievement programs the analysis levels: - To know and to detail the historical elements which started the wars between Castile and Aragon and its development using historiographical tools, and to analyze the natural characteristic of the territory through cartographical tools. - To understand and to analyze the different architectural types and the building traditions employed in the military buildings in the time researched. - To locate, to document, and to select for their analysis the fortresses and military constructions erected during these border wars in the actual province of Soria through fieldwork and bibliographical and cartographical methods. - To conduct a general study on the fortified system in territorial scale. - To research the architectural, constructive and defensive typology of the system of these border late medieval fortifications. - To analyze the construction logic of the selected case studies and to characterize in the items of material, elements, systems and construction processes. - To sort scattered historical information and to correct mistakes to make a base by which to establish a historic speech of each case study. - To compare and to relate the construction techniques employed in these fortresses with those used in the same time range . - To spread for discussion the research results in the usual scientists forums. The method combines the destock work with an intense fieldwork. Fifty fortifications have been documented and it has written their corresponding data collection card. Data collection has been included in a database that includes general aspects, typological, constructive and basic bibliographical data, as an inventory of fortifications in the province. The selected fortifications are grouped according to a typological and constructive classification which lead the lines of the later study. There is a chapter for the antecedents in which the history of the medieval fortified construction in Europe and in Spain is studied by analyzing the evolution of architectural types and the many cultural influences along the opposite seasides of the Mediterranean Sea, from the Islamic and Crusader East to the Iberian Peninsula in where there were a long and continuous war during eight hundred years. The territory is analyzed as a container of fortifications. This analysis reveals that there is an intimate relationship between the location of the fortifications and the natural forms that define the communication roads between the Duero, Ebro and Tajo valleys. Indeed, the study area has been a cross-territory from ancient times more than a frontierterritory. This communication character explains the concerns about its control both by Rome and by the Muslims of Córdoba as medieval Christian kingdoms. The analysis of historical elements is supplemented by detailed study of border war between Castile and Aragon and the social and political issues that led to the fortification as border definition system and spatial, jurisdictional, social and administrative planning. The fortified architecture is essentially functional: it is responsible for defense. In this sense, after a morphological study of selected castles is performed an extensive analysis of its defensive elements, investigating its origin and application. This analisis serves for the definition of parameters for dating. The purpose of the thesis is the study of the constructive logic. First, various building materials are explained. Then, masonry is grouped into two major constructive groups: rigged masonry and formwork masonry. The historical evolution and the constructive typology and mensiology are studied for each one of the three main techniques: the use of brickwork, the mortar wall and rammed-earth. Many case studies have been documented along the Iberian Peninsula and also in the study area. As conclusion, there is a dimensional evolution of the rammed-earth walls. This evolution is more evident into the Muslim masonry than in the late medieval walls: the reason is the use of the cubit as module. From each of the techniques discussed, a singular and representative case of study has been selected. The castle of Arcos de Jalon is a significant example of mix masonry of stone and brick rows. The walled city of Peñalcázar is built with masonry formwork. Serón de Nágima castle, at last, is a typical and main case of the use of the rammedearth wall of late medieval military architecture. Each of these three case studies were examined under the same four analysis levels above mentioned: territorial, historical, architectural and defensive and constructive. The systematic method of study has facilitated the order in the research and the obtaining of results and conclusions that verify the hypotheses and achieve the research objectives. Dating of the fortifications construction has been revised by studying the cronotypological issues of its masonry. The method can be transferred to the study of other fortified systems. Finally, the thesis describes two main research new ways aimed at completing the study of the late medieval fortified border of Castile in the actual province of Soria. The first of them is the characterization and datig by physicochemical methods the sample pieces of wood construction preserved embedded in the masonry. The second research way is the investigation of the documents in archives that may reveal new information about the foundation, repair, sale or any aspect to economic, legal, organizational or administrative concerning fortifications in contemporary documents.