Resumo:
This paper addresses the seismic analysis of a deeply embedded non-slender structure hosting the pumping unit of a reservoir. The dynamic response in this type of problems is usually studied under the assumption of a perfectly rigid structure using a sub-structuring procedure (three-step solution) proposed specifically for this hypothesis. Such an approach enables a relatively simple assessment of the importance of some key factors influencing the structural response. In this work, the problem is also solved in a single step using a direct approach in which the structure and surrounding soil are modelled as a coupled system with its actual geometry and flexibility. Results indicate that, quite surprisingly, there are significant differences among prediction using both methods. Furthermore, neglecting the flexibility of the structure leads to a significant underestimation of the spectral accelerations at certain points of the structure.
Resumo:
Este artículo presenta la aplicación del M.E.C. a un problema de interacción suelo-estructura. Se trata de una estructura rígida empotrada a gran profundidad en un terreno muy duro y sometido a acciones sísmicas de importancia. Tras recordar los conceptos básico del problema se describe la discretización utilizada para la resolución mediante el método de los tres pasos. Se describe también la modificación inducida por la presencia de la estructura en la solicitación sísmica tanto en profundidad como en distancia a aquella.