9 resultados para Fire Extinguishing Systems
em Universidad Politécnica de Madrid
Resumo:
Between 2003 and 2007 an urban network or road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as "Calle 30 Project" counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure includieng, in some parts of the tunnel, fixed fire fighting system based on water mist. Whithin this framework a large-scale programme of fire tests was planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinguishing system. In addition, these large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San pedro of Anes" which includes a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test's programme carried out and some previous results obtained.
Resumo:
Between 2003 and 2007 an urban network of road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as “Calle30 Project” counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure including,in some parts of the tunnel, fixed fire fighting system based on water mist. Within this framework a large-scale campaign of fire tests were planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinction system. In addition, this large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San Pedro of Anes" which counts with a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test’s campaign carried out and some previous results obtained.
Resumo:
Un incendio en el interior de un almacén de pirotecnia puede provocar la iniciación más o menos simultánea de los artículos existentes en su interior, con su consecuente onda de choque potenciada por la presión de los propios gases generados en su interior. La finalidad de esta tesis doctoral consiste en analizar los fenómenos que se desarrollan como consecuencia de un incendio interior en los almacenes de pirotecnia y establecer posibles medidas eficaces de prevención y protección con objeto de reducir el riesgo de explosión.. Inicialmente se llevó a cabo un análisis del riesgo de explosión, evaluando las consecuencias en caso de producirse un fuego interior. Los resultados fueron catastróficos. Finalmente, y con objeto de minimizar la posibilidad de producirse un incendio en el interior de un almacén, se evaluaron diferentes sistemas de detección y extinción automática de incendios para almacenes pirotécnicos, realizándose pruebas a escala real. En particular, la presente tesis consta de los siguientes trabajos: 1) Evaluación de la sobrepresión generada por la explosión de artificios pirotécnicos en el interior de almacenes, mediante pruebas de explosión de artículos pirotécnicos, con el fin de evaluar las posibles consecuencias en caso de materializarse una explosión, y disponer de información que permita conocer el grado de resistencia de las estructuras de los almacenes, así como el diseño adecuado de las mismas para soportar los efectos de tales explosiones. 2) Evaluación del efecto de un incendio en el interior de un almacén de pirotecnia mediante pruebas a escala real, con el fin de evaluar la posibilidad de la iniciación simultánea de los artículos pirotécnicos almacenados en su interior, y su consecuente explosión, así como las consecuencias en caso de materializarse la explosión. 3) Análisis de sistemas de detección y extinción automática de incendios para almacenes de pirotecnia, mediante la realización de pruebas a escala real para verificar la eficiencia y eficacia de tales sistemas y agentes para sofocar un incendio pirotécnico de forma tal que se evite la posible explosión asociada. 4) Evaluación de nuevos agentes extintores utilizados en los sistemas de extinción automática de incendios, que actualmente se están utilizando en el sector pirotécnico nacional, mediante la realización de pruebas a escala real. Los resultados obtenidos han permitido al Ministerio de Industria, Energía y Turismo actualizar la reglamentación vigente aplicable (Instrucción Técnica Complementaria número 17 del Reglamento de artículos pirotécnicos y cartuchería, aprobado por el Real Decreto 563/2010, de 7 de mayo). ABSTRACT A fire inside a pyrotechnics magazine can cause the more or less simultaneous initiation of the stored articles, with the wave of shock that is produced promoted by the pressure of the gases generated in its interior. The purpose of this PhD thesis is to analyze the phenomena that develop as a result of a fire inside the pyrotechnics stores and establish possible effective prevention and protection measures to reduce the risk of explosionAn analysis of the risk of explosion and fire consequences in a pyrotechnic magazine, testing to real scale, was initially carried out. The results were catastrophic. Finally, and in order to minimize the possibility of a fire inside a pyrotechnic magazine, different systems of detection and automatic extinction of fires in pyrotechnic magazines were evaluated, testing to real scale. Particularly, this thesis has the following parts: 1) Evaluation of the pressure generated by the pyrotechnic explosion in a magazine, with explosión tests of pyrotechnic articles, in order to evaluate the possible consequences in case of materialize an explosion, and provide information to know the resistance grade of the magazine structures, as well as the right design of those to withstand the effects of such explosions. 2) Evaluation of the effect of a fire inside a pyrotechnic magazine by full-scale tests, in order to evaluate the possibility of simultaneous initiation of the pyrotechnic articles stored inside, and the resulting explosion, as well as the consequences in case of materialize an explosion. 3) Analysis and evaluation of detection and automatic fire extinguishing in pyrotechnic magazines, by full-scale tests in order to verify the efficiency and effectiveness of such systems and agents to quell a pyrotechnic fire and avoid the posible mass explosion. 4) Evaluation of new extinguishing agent used in automatic fire extinguishers, which are currently being used in the national fireworks industry, by full-scale tests. The results obtained have allowed the Ministry of Industry, Energy and Tourism, update the current regulation (Complementary Technical Instruction 17 of the Regulation of Pyrotecnic Articles and Ammunition, approved by the Royal Decree 563/2010, of May 7).
Resumo:
Esta es la búsqueda de respuestas a esa duda constante: De dónde venimos y que hemos ido dejando por el camino. ¿Está todo claro en este recorrido o hemos actuado por acumulación de errores heredados de procesos anteriores? Es la investigación a través del descubrimiento de nuestro pasado, de nuestros orígenes en materia de seguridad de protección contra incendios, y sobre todo de ejecución de una arquitectura pensada para ser recorrida con mayor seguridad y ser evacuada en un tiempo razonable. El trabajo investiga, a nivel nacional, la evolución de la sociedad y sus efectos sobre la manera de interpretar el problema de la seguridad contra incendios en los edificios. El interés fundamentalmente es poner en claro todos aquellos aspectos que afectan a la evacuación de las personas. Para ello se han estudiado los principales hitos de actuación, las preocupaciones principales surgidas en cada momento y las soluciones adoptadas. Se ha comprobado su aplicación o su demora hasta que se ha producido el siguiente gran suceso que ha motivado una nueva revisión de los procedimientos de diseño y control. En primer lugar, tratando de relacionar los incendios fundamentales que han influido en nuestra forma de abordar el problema en distintos momentos de la historia de España. En segundo lugar, haciendo un recorrido sobre la figura del arquitecto y su participación en los medios de control y legislación sobre la manera de intervenir en el servicio de incendios o de resolver los edificios en materia de protección contra incendios o evacuación de sus ocupantes. En definitiva, descubriendo los escritos de algunos especialistas, fundamentales para entender nuestra manera de abordar el problema de la protección en los edificios, a lo largo de la historia. Se ha revisado como se han producido los siniestros más importantes en teatros y otros locales públicos .Analizando la forma en que los arquitectos implicados han tratado de resolver las posibles deficiencias ante el riesgo. Se trata de la tipología edificatoria donde, por primera vez, surge la preocupación por adoptar medidas y procedimientos de seguridad en caso de incendio. Resultan locales con una importante siniestralidad, donde se desarrolla la principal actividad lúdica del momento, y que por el importante número de personas que albergan, son fuente de preocupación entre el público y las autoridades. Otras cuestiones en un tema tan amplio, que quedan simplemente esbozadas en este trabajo de investigación, son los procedimientos de los sistemas de extinción, la estructura organizativa de la ciudad, las primeras sociedades de seguros de incendios, la aparición de patentes a partir del desarrollo industrial del siglo XIX. Todo ello, con el hilo conductor de la reglamentación que se ha ido elaborando al respecto. Al principio, sobre espectáculos públicos, acotando el punto de partida en la materia de nuestra reglamentación. Anticipando sistemas constructivos y datos dimensionales de la evacuación. Llegados a mediados del siglo XX, abordando otros usos. Haciendo seguimiento de la modernización de los procesos edificatorios y la reglamentación sectorial. Recabando información de las organizaciones profesionales que comienzan a reclamar una coordinación nacional de los sistemas preventivos y que desemboca en el Proyecto de Reglamento de prevención contra el fuego que nunca será publicado. Toda esta etapa, plagada de documentos de carácter voluntario u obligatorio, local y nacional, van definiendo los criterios dimensionales con los que debe resolverse los elementos arquitectónicos susceptibles de servir para la evacuación. Se trata de una etapa intensa en documentación, cambiante, sujeta a los criterios que establecen los países del entorno más avanzados en la materia. Las dos últimas décadas del siglo, acotadas por la transición política y varios siniestros de graves consecuencias, definen el proceso normativo que culmina con el código técnico de la edificación que hoy conocemos. Es un periodo de aprendizaje y asimilación del capítulo de la seguridad, donde los métodos son variados. Donde la intencionalidad última es trasladar un sistema prescriptivo a un modelo prestacional propio de la madurez en el análisis del tema y en las corrientes de los países del entorno. ABSTRACT This is the search for answers to that constant question: Where do we come from and what have left along the way? Has everything been clear on this journey, or have we acted as a result of a collection of errors learned from prior processes? This has been research through exploration of our past, of our origins regarding fire protection safety, and, above all, of the endeavour to utilize architecture aimed at offering the highest level of safety and evacuation in a reasonable time. This project has researched society’s change nationwide and its effects on how to interpret the difficulty of fire protection safety in buildings. Its focus has fundamentally been to clarify those aspects that affect the evacuation of people. To this end, the main milestones of action, the principal concerns that have arisen at each step, and the solutions taken have all been studied. A check was performed on their application; or their delay until a significant event occurred that prompted a new revision of design and control procedures. Firstly, this was done by attempting to connect the main fires that have influenced how we handle the problem at different times in Spain’s history. Secondly, an examination was done on the figure of the architect and his participation in the means of control and legislation on how to intercede in fire services, or how the architect finds solutions for buildings in terms of fire protection, or the evacuation of their occupants. In short, the written works of certain specialists, who are essential to our understanding of how to deal with the problem of protection in buildings, were explored throughout history. A study was done on the most significant disasters in theatres and other public establishments. This was done by analysing the way the architects involved have aimed to solve possible points liable to risk. It is a classification of building where, for the first time, the concern arose to adopt safety measures and procedures in the event of fires. Public establishments with considerable accident rates emerged. Here the main entertainment activities of the time took place. These spaces were a source of worry among the public and authorities due to the high number of persons they accommodated. Other issues in such an extensive subject, which are only outlined in this research study, are procedures in extinguishing systems, the organizational structure of cities, the first fire insurance companies, and the appearance of patents after the industrial development of the 19th century. All of these aspects are joined by the common thread of regulations that have been created in this matter. At the beginning, these regulations were for public shows, thus defining the starting point for our regulations. This was done in anticipation of structural systems and size data of evacuations. With the arrival of the mid-20th century, different uses were addressed. A modernization of construction processes and the industry regulations were tracked. Information was gathered from professional organizations that began to demand a national coordination of prevention systems which led to the Regulation Project on fire prevention which will never be published. Throughout this stage, replete with voluntary and compulsory documents, both on the local and national level, the dimensional criteria to be used in the resolution of architectural elements open to use in evacuation were defined. This was a period that was filled with documentation, change, and subject to the criteria that the most advanced countries in the field established in this regard. The final two decades of the century, marked by political transition and several accidents with grave consequences, defined the regulation process that culminated with the building technical code known today. This was a period of learning and understanding in the chapter of safety, where the methods are varied. In this chapter, the ultimate goal is to insert a prescriptive-based standard into a performance-based code suitable for cultivated experience in analysis of the subject and the tendencies in countries dealing with this field.
Resumo:
El Hogar Digital Accesible (HDA) de la ETSIST nace con el propósito de acercar las nuevas Tecnologías de la Información a las personas que precisan de necesidades concretas de accesibilidad y usabilidad, dotándoles de herramientas que les permitan aumentar su calidad de vida, confort, seguridad y autonomía. El entorno del HDA consta de elementos de control para puertas, persianas, iluminación, agua o gas, sensores de temperatura, incendios, gas, sistemas de climatización, sistemas de entretenimiento y sistemas de seguridad tales como detectores de presencia y alarmas. Todo ello apoyado sobre una arquitectura de red que proporciona una pasarela residencial y un acceso a banda ancha. El objetivo principal de este PFG ha sido el desarrollo de un sistema de autenticación para el Hogar Digital Accesible de bajo coste. La idea de integrar un sistema de autenticación en el HDA, surge de la necesidad de proteger de accesos no deseados determinados servicios disponibles dentro de un ámbito privado. Algunos de estos servicios pueden ser tales como el acceso a la lectura de los mensajes disponibles en el contestador automático, el uso de equipos multimedia, la desconexión de alarmas de seguridad o simplemente la configuración de ambientes según el usuario que esté autenticado (intensidad de luz, temperatura de la sala, etc.). En el desarrollo han primado los principios de accesibilidad, usabilidad y seguridad necesarios para la creación de un entorno no invasivo, que permitiera acreditar la identidad del usuario frente al sistema HDA. Se ha planteado como posible solución, un sistema basado en el reconocimiento de un trazo realizado por el usuario. Este trazo se usará como clave de cara a validar a los usuarios. El usuario deberá repetir el trazado que registró en el sistema para autenticarse. Durante la ejecución del presente PFG, se justificará la elección de este mecanismo de autenticación frente a otras alternativas disponibles en el mercado. Para probar la aplicación, se ha podido contar con dos periféricos de distintas gamas, el uDraw creado para la PS3 que se compone de una tableta digitalizadora y un lápiz que permite recoger los trazos realizados por el usuario de forma inalámbrica y la tableta digitalizadora Bamboo de Wacom. La herramienta desarrollada permite a su vez, la posibilidad de ser usada por otro tipo de dispositivos como es el caso del reloj con acelerómetro de 3 ejes de Texas Instruments Chronos eZ430 capaz de trasladar los movimientos del usuario al puntero de un ratón. El PFG se encuentra dividido en tres grandes bloques de flujo de trabajo. El primero se centra en el análisis del sistema y las tecnologías que lo componen, incluyendo los distintos algoritmos disponibles para realizar la autenticación basada en reconocimiento de patrones aplicados a imágenes que mejor se adaptan a las necesidades del usuario. En el segundo bloque se recoge una versión de prueba basada en el análisis y el diseño UML realizado previamente, sobre la que se efectuaron pruebas de concepto y se comprobó la viabilidad del proyecto. El último bloque incluye la verificación y validación del sistema mediante pruebas que certifican que se han alcanzado los niveles de calidad necesarios para la consecución de los objetivos planteados, generando finalmente la documentación necesaria. Como resultado del trabajo realizado, se ha obtenido un sistema que plantea una arquitectura fácilmente ampliable lograda a través del uso de técnicas como la introspección, que permiten separar la lógica de la capa de negocio del código que la implementa, pudiendo de forma simple e intuitiva sustituir código mediante ficheros de configuración, lo que hace que el sistema sea flexible y escalable. Tras la realización del PFG, se puede concluir que el producto final obtenido ha respondido de forma satisfactoria alcanzando los niveles de calidad requeridos, siendo capaz de proporcionar un sistema de autenticación alternativo a los convencionales, manteniendo unas cotas de seguridad elevadas y haciendo de la accesibilidad y el precio sus características más reseñables. ABSTRACT. Accessible Digital Home (HDA) of the ETSIST was created with the aim of bringing the latest information and communications technologies closer to the people who has special needs of accessibility and usability increasing their quality of life, comfort, security and autonomy. The HDA environment has different control elements for doors, blinds, lighting, water or gas, temperature sensors, fire protection systems, gas flashover, air conditioning systems, entertainments systems and security systems such as intruders detectors and alarms. Everything supported by an architecture net which provides a broadband residential services gateway. The main goal of this PFG was the development of a low-cost authentication system for the Accessible Digital Home. The idea of integrating an authentication system on the HDA, stems from the need to safeguard certain private key network resources from unauthorized access. Some of said resources are the access to the answering machine messages, the use of multimedia devices, the alarms deactivation or the parameter settings for each environment as programmed by the authenticated user (light intensity, room temperature, etc.). During the development priority was given to concepts like accessibility, usability and security. All of them necessary to create a non invasive environment that allows the users to certify their identity. A system based on stroke pattern recognition, was considered as a possible solution. This stroke is used as a key to validate users. The user must repeat the stroke that was saved on the system to validate access. The selection of this authentication mechanism among the others available options will be justified during this PFG. Two peripherals with different ranges were used to test the application. One of them was uDraw design for the PS3. It is wireless and is formed by a pen and a drawing tablet that allow us to register the different strokes drawn by the user. The other one was the Wacom Bamboo tablet, that supports the same functionality but with better accuracy. The developed tool allows another kind of peripherals like the 3-axes accelerometer digital wristwatch Texas Instruments Chronos eZ430 capable of transfering user movements to the mouse cursor. The PFG is divided by three big blocks that represent different workflows. The first block is focused on the system analysis and the technologies related to it, including algorithms for image pattern recognition that fits the user's needs. The second block describes how the beta version was developed based on the UML analysis and design previously done. It was tested and the viability of the project was verified. The last block contains the system verification and validation. These processes certify that the requirements have been fulfilled as well as the quality levels needed to reach the planned goals. Finally all the documentation has been produced. As a result of the work, an expandable system has been created, due to the introspection that provides the opportunity to separate the business logic from the code that implements it. With this technique, the code could be replaced throughout configuration files which makes the system flexible and highly scalable. Once the PFG has finished, it must therefore be concluded that the final product has been a success and high levels of quality have been achieved. This authentication tool gives us a low-cost alternative to the conventional ones. The new authentication system remains security levels reasonably high giving particular emphasis to the accessibility and the price.
Resumo:
The main objective of ventilation systems in case of fire is the reduction of the possible consequences by achieving the best possible conditions for the evacuation of the users and the intervention of the emergency services. In the last years, the required quick response of the ventilation system, from normal to emergency mode, has been improved by the use of automatic and semi-automatic control systems, what reduces the response times through the support to the operators decision taking, and the use of pre-defined strategies. A further step consists on the use of closedloop algorithms, which takes into account not only the initial conditions but their development (air velocity, traffic situation, etc), optimizing the quality of the smoke control process
Resumo:
The design, construction and operation of the tunnels of M-30, the major ring road in the city of Madrid (Spain), represent a very interesting project in wich a wide variety of situations -geometrical, topographical, etc.- had to be covered, in variable conditions of traffic. For that reasons, the M-30 project is a remarkable technical challenge, which, after its completion, turned into an international reference. From the "design for safety" perspective, a holistic approach has been used to deal with new technologies, integration of systems and development of the procedures to reach the maximum level. However, one of the primary goals has been to achieve reasonable homogeneity characteristics which can permit operate a netword of tunels as one only infraestructure. In the case of the ventilation system the mentioned goals have implied innovative solutions and coordination efforts of great interest. Consequently, this paper describes the principal ideas underlying the conceptual solution developed focusing on the principal peculiarities of the project.
Resumo:
The main objective of ventilation systems in case of fire is the reduction of the possible consequences by achieving the best possible conditions for the evacuation of the users and the intervention of the emergency services. The required immediate transition, from normal to emergency functioning of the ventilation equipments, is being strengthened by the use of automatic and semi-automatic control systems, what reduces the response times through the help to the operators, and the use of pre-defined strategies. A further step consists on the use of closed-loop algorithms, which takes into account not only the initial conditions but their development (air velocity, traffic situation, etc.), optimizing smoke control capacity.
Resumo:
The main objective of ventilation systems in tunnels is to reach the highest possible safety level both in service and fire situation; being the fire one, the most relevant when designing the system. When designing a longitudinal ventilation system, the methodology to evaluate the capacity of the system is similar both in service and fire situation, with the exception of the chimney effect and the phenomena of thermal transfer which is responsible or the changes in the density of the air. When facing the dimensioning task for longitudinal ventilated tunnels, although similar methodologies are used in different countries, specific hypothesis (aerodynamic, thermal properties, traffic) even if discussed in the literature or current practice, are not usually detailed in the regulations or recommendations. The aim of this paper is to propose a probabilistic approach to the problem which would allow the designer, and the tunnel owner, to understand the uncertainty and sensibility adopted in the results and, eventually, identify possible ways of optimizing the ventilation solution to be adopted.