18 resultados para Failure mechanism
em Universidad Politécnica de Madrid
Resumo:
This paper presents the results of cyclic loading tests on two large-scale reinforced concrete structural walls that were conducted at Purdue University. One of the walls had confinement reinforcement meeting ACI-318-11 requirements while the other wall did not have any confinement reinforcement. The walls were tested as part of a larger study aimed at indentifying parameters affecting failure modes observed to limit the drift capacity of structural walls in Chile during the Maule Earthquake of 2010. These failure modes include out-of-plane buckling (of the wall rather tan individual reinforcing bars), compression failure, and bond failure. This paper discusses the effects of confinement on failure mode. Distributions of unit strain and curvature obtained with a dense array of non-contact coordinate-tracking targets are also presented.
Resumo:
La fisuración iniciada en la superficie de los pavimentos asfálticos constituye uno de los más frecuentes e importantes modos de deterioro que tienen lugar en los firmes bituminosos, como han demostrado los estudios teóricos y experimentales llevados a cabo en la última década. Sin embargo, este mecanismo de fallo no ha sido considerado por los métodos tradicionales de diseño de estos firmes. El concepto de firmes de larga duración se fundamenta en un adecuado seguimiento del proceso de avance en profundidad de estos deterioros y la intervención en el momento más apropiado para conseguir mantenerlos confinados como fisuras de profundidad parcial en la capa superficial más fácilmente accesible y reparable, de manera que pueda prolongarse la durabilidad y funcionalidad del firme y reducir los costes generalizados de su ciclo de vida. Por lo tanto, para la selección de la estrategia óptima de conservación de los firmes resulta esencial disponer de metodologías que posibiliten la identificación precisa in situ de la fisuración descendente, su seguimiento y control, y que además permitan una determinación fiable y con alto rendimiento de su profundidad y extensión. En esta Tesis Doctoral se presentan los resultados obtenidos mediante la investigación sistemática de laboratorio e in situ llevada a cabo para la obtención de datos sobre fisuración descendente en firmes asfálticos y para el estudio de procedimientos de evaluación de la profundidad de este tipo de fisuras empleando técnicas de ultrasonidos. Dichos resultados han permitido comprobar que la metodología no destructiva propuesta, de rápida ejecución, bajo coste y sencilla implementación (principalmente empleada hasta el momento en estructuras metálicas y de hormigón, debido a las dificultades que introduce la naturaleza viscoelástica de los materiales bituminosos) puede ser aplicada con suficiente fiabilidad y repetibilidad sobre firmes asfálticos. Las medidas resultan asimismo independientes del espesor total del firme. Además, permite resolver algunos de los inconvenientes frecuentes que presentan otros métodos de diagnóstico de las fisuras de pavimentos, tales como la extracción de testigos (sistema destructivo, de alto coste y prolongados tiempos de interrupción del tráfico) o algunas otras técnicas no destructivas como las basadas en medidas de deflexiones o el georradar, las cuales no resultan suficientemente precisas para la investigación de fisuras superficiales. Para ello se han realizado varias campañas de ensayos sobre probetas de laboratorio en las que se han estudiado diferentes condiciones empíricas como, por ejemplo, distintos tipos de mezclas bituminosas en caliente (AC, SMA y PA), espesores de firme y adherencias entre capas, temperaturas, texturas superficiales, materiales de relleno y agua en el interior de las grietas, posición de los sensores y un amplio rango de posibles profundidades de fisura. Los métodos empleados se basan en la realización de varias medidas de velocidad o de tiempo de transmisión del pulso ultrasónico sobre una única cara o superficie accesible del material, de manera que resulte posible obtener un coeficiente de transmisión de la señal (mediciones relativas o autocompensadas). Las mediciones se han realizado a bajas frecuencias de excitación mediante dos equipos de ultrasonidos diferentes dotados, en un caso, de transductores de contacto puntual seco (DPC) y siendo en el otro instrumento de contacto plano a través de un material especialmente seleccionado para el acoplamiento (CPC). Ello ha permitido superar algunos de los tradicionales inconvenientes que presenta el uso de los transductores convencionales y no precisar preparación previa de las superficies. La técnica de autocalibración empleada elimina los errores sistemáticos y la necesidad de una calibración local previa, demostrando el potencial de esta tecnología. Los resultados experimentales han sido comparados con modelos teóricos simplificados que simulan la propagación de las ondas ultrasónicas en estos materiales bituminosos fisurados, los cuales han sido deducidos previamente mediante un planteamiento analítico y han permitido la correcta interpretación de dichos datos empíricos. Posteriormente, estos modelos se han calibrado mediante los resultados de laboratorio, proporcionándose sus expresiones matemáticas generalizadas y gráficas para su uso rutinario en las aplicaciones prácticas. Mediante los ensayos con ultrasonidos efectuados en campañas llevadas a cabo in situ, acompañados de la extracción de testigos del firme, se han podido evaluar los modelos propuestos. El máximo error relativo promedio en la estimación de la profundidad de las fisuras al aplicar dichos modelos no ha superado el 13%, con un nivel de confianza del 95%, en el conjunto de todos los ensayos realizados. La comprobación in situ de los modelos ha permitido establecer los criterios y las necesarias recomendaciones para su utilización sobre firmes en servicio. La experiencia obtenida posibilita la integración de esta metodología entre las técnicas de auscultación para la gestión de su conservación. Abstract Surface-initiated cracking of asphalt pavements constitutes one of the most frequent and important types of distress that occur in flexible bituminous pavements, as clearly has been demonstrated in the technical and experimental studies done over the past decade. However, this failure mechanism has not been taken into consideration for traditional methods of flexible pavement design. The concept of long-lasting pavements is based on adequate monitoring of the depth and extent of these deteriorations and on intervention at the most appropriate moment so as to contain them in the surface layer in the form of easily-accessible and repairable partial-depth topdown cracks, thereby prolonging the durability and serviceability of the pavement and reducing the overall cost of its life cycle. Therefore, to select the optimal maintenance strategy for perpetual pavements, it becomes essential to have access to methodologies that enable precise on-site identification, monitoring and control of top-down propagated cracks and that also permit a reliable, high-performance determination of the extent and depth of cracking. This PhD Thesis presents the results of systematic laboratory and in situ research carried out to obtain information about top-down cracking in asphalt pavements and to study methods of depth evaluation of this type of cracking using ultrasonic techniques. These results have demonstrated that the proposed non-destructive methodology –cost-effective, fast and easy-to-implement– (mainly used to date for concrete and metal structures, due to the difficulties caused by the viscoelastic nature of bituminous materials) can be applied with sufficient reliability and repeatability to asphalt pavements. Measurements are also independent of the asphalt thickness. Furthermore, it resolves some of the common inconveniences presented by other methods used to evaluate pavement cracking, such as core extraction (a destructive and expensive procedure that requires prolonged traffic interruptions) and other non-destructive techniques, such as those based on deflection measurements or ground-penetrating radar, which are not sufficiently precise to measure surface cracks. To obtain these results, extensive tests were performed on laboratory specimens. Different empirical conditions were studied, such as various types of hot bituminous mixtures (AC, SMA and PA), differing thicknesses of asphalt and adhesions between layers, varied temperatures, surface textures, filling materials and water within the crack, different sensor positions, as well as an ample range of possible crack depths. The methods employed in the study are based on a series of measurements of ultrasonic pulse velocities or transmission times over a single accessible side or surface of the material that make it possible to obtain a signal transmission coefficient (relative or auto-calibrated readings). Measurements were taken at low frequencies by two short-pulse ultrasonic devices: one equipped with dry point contact transducers (DPC) and the other with flat contact transducers that require a specially-selected coupling material (CPC). In this way, some of the traditional inconveniences presented by the use of conventional transducers were overcome and a prior preparation of the surfaces was not required. The auto-compensating technique eliminated systematic errors and the need for previous local calibration, demonstrating the potential for this technology. The experimental results have been compared with simplified theoretical models that simulate ultrasonic wave propagation in cracked bituminous materials, which had been previously deduced using an analytical approach and have permitted the correct interpretation of the aforementioned empirical results. These models were subsequently calibrated using the laboratory results, providing generalized mathematical expressions and graphics for routine use in practical applications. Through a series of on-site ultrasound test campaigns, accompanied by asphalt core extraction, it was possible to evaluate the proposed models, with differences between predicted crack depths and those measured in situ lower than 13% (with a confidence level of 95%). Thereby, the criteria and the necessary recommendations for their implementation on in-service asphalt pavements have been established. The experience obtained through this study makes it possible to integrate this methodology into the evaluation techniques for pavement management systems.
Resumo:
SUMMARY Concentration Photovoltaic Systems (CPV) have been proposed as an alternative to conventional systems. During the last years, there has been a boom of the CPV industry caused by the technological progress in all the elements of the system. and mainly caused by the use of multijunction solar cells based on III-V semiconductors, with efficiencies exceeding to 43%. III-V solar cells have been used with high reliability results in a great number of space missions without concentration. However, there are no previous results regarding their reliability in concentration terrestrial applications, where the working conditions are completely different. This lack of experience, together with the important industrial interest, has generated the need to evaluate the reliability of the cells. For this reason, nowadays there are several research centers around the undertaking this task. The evaluation of the reliability of this type of devices by means of accelerated tests is especially problematic when they work at medium or high concentration, because it is practically impossible to emulate real working conditions of the cell inside climatic chambers. In fact, as far as we know, the results that appear in this Thesis are the first estimating the Activation Energy of the failure mechanism involved, as well as the warranty of the III-V concentrator solar cells tested here. To evaluate the reliability of III-V very high concentrator solar cells by means of accelerated tests, a variety of activities, described in this Thesis have been carried out. The First Part of the memory presents the theoretical part of the Doctoral Thesis. After the Introduction, chapter 2 presents the state of the art in degradation and reliability of CPV systems and solar cells. Chapter 3 introduces some reliability definitions and the application of specific statistical functions to the evaluation of the reliability and parameters. From these functions, important parameters will be calculated to be used later in the experimental results of Thesis. The Second Part of the memory contains the experimental. Chapter 4 shows the types of accelerated tests and the main goals pursuit with them when carried out over CPV systems and solar cells. In order to evaluate quantitatively the reliability of the III-V concentrator solar cells used in these tests, some modifications have been introduced which discussion will be tackled here. Based on this analysis the working plan of the tests carried out in this Doctoral Thesis is presented. Chapter 5 presents a new methodology as well as the necessary instrumentation to carry out the tests described here. This new methodology takes into account the adaptation, improvement and novel techniques needed to test concentrator solar cells. The core of this memory is chapter 6, which presents the results of the characterization of the cells during the accelerated life tests and the analysis of the aforementioned results with the purpose of getting quantitative values of reliability in real working conditions. The acceleration factor of the accelerated life tests, under nominal working conditions has been calculated. Accordingly, the validity of the methodology as well as the calculations based on the reliability assessment, have also been demonstrated. Finally, quantitative values of degradation, reliability and warranty of the solar cells under field nominal working conditions have been calculated. With the development of this Doctoral Thesis the reliability of very high concentrator GaAs solar cells of small area has been evaluated. It is very interesting to generalize the procedures described up to this point to III-V multijunction solar cells of greater area. Therefore, chapter 7 develops this generalization and introduces also a useful thermal modeling by means of finite elements of the test cells’ circuits. In the last chapter, the summary of the results and the main contributions of this Thesis are outlined and future research activities are identified. RESUMEN Los Sistemas Fotovoltaicos de Concentración (SFC) han sido propuestos como una alternativa a los sistemas convencionales de generación de energía. Durante los últimos años ha habido un auge de los SFC debido a las mejoras tecnológicas en todos los elementos del sistema, y principalmente por el uso de células multiunión III-V que superan el 43% de rendimiento. Las células solares III-V han sido utilizadas con elevada fiabilidad en aplicaciones espaciales sin concentración, pero no existe experiencia de su fiabilidad en ambiente terrestre a altos niveles de concentración solar. Esta falta de experiencia junto al gran interés industrial ha generado la necesidad de evaluar la fiabilidad de las células, y actualmente hay un significativo número de centros de investigación trabajando en esta área. La evaluación de la fiabilidad de este tipo de dispositivos mediante ensayos acelerados es especialmente problemática cuando trabajan a media o alta concentración por la casi imposibilidad de emular las condiciones de trabajo reales de la célula dentro de cámaras climáticas. De hecho, que sepamos, en los resultados de esta Tesis se evalúa por primera vez la Energía de Activación del mecanismo de fallo de las células, así como la garantía en campo de las células de concentración III-V analizadas. Para evaluar la fiabilidad de células solares III-V de muy alta concentración mediante ensayos de vida acelerada se han realizado diversas actividades que han sido descritas en la memoria de la Tesis. En la Primera Parte de la memoria se presenta la parte teórica de la Tesis Doctoral. Tras la Introducción, en el capítulo 2 se muestra el estado del arte en degradación y fiabilidad de células y Sistemas Fotovoltaicos de Concentración. En el capítulo 3 se exponen de forma resumida las definiciones de fiabilidad y funciones estadísticas que se utilizan para la evaluación de la fiabilidad y sus parámetros, las cuales se emplearán posteriormente en los ensayos descritos en este Tesis. La Segunda Parte de la memoria es experimental. En el capítulo 4 se describen los tipos y objetivos de los ensayos acelerados actualmente aplicados a SFC y a las células, así como las modificaciones necesarias que permitan evaluar cuantitativamente la fiabilidad de las células solares de concentración III-V. En base a este análisis se presenta la planificación de los trabajos realizados en esta Tesis Doctoral. A partir de esta planificación y debido a la necesidad de adaptar, mejorar e innovar las técnicas de ensayos de vida acelerada para una adecuada aplicación a este tipo de dispositivos, en el capítulo 5 se muestra la metodología empleada y la instrumentación necesaria para realizar los ensayos de esta Tesis Doctoral. El núcleo de la memoria es el capítulo 6, en él se presentan los resultados de caracterización de las células durante los ensayos de vida acelerada y el análisis de dichos resultados con el objetivo de obtener valores cuantitativos de fiabilidad en condiciones reales de trabajo. Se calcula el Factor de Aceleración de los ensayos acelerados con respecto a las condiciones nominales de funcionamiento a partir de la Energía de Activación obtenida, y se demuestra la validez de la metodología y cálculos empleados, que son la base de la evaluación de la fiabilidad. Finalmente se calculan valores cuantitativos de degradación, fiabilidad y garantía de las células en condiciones nominales en campo durante toda la vida de la célula. Con el desarrollo de esta Tesis Doctoral se ha evaluado la fiabilidad de células III-V de área pequeña, pero es muy interesante generalizar los procedimientos aquí desarrollados para las células III-V comerciales de área grande. Por este motivo, en el capítulo 7 se analiza dicha generalización, incluyendo el modelado térmico mediante elementos finitos de los circuitos de ensayo de las células. En el último capítulo se realiza un resume del trabajo y las aportaciones realizadas, y se identifican las líneas de trabajo a emprender en el futuro.
Resumo:
El acero es, junto con el hormigón, el material más ampliamente empleado en la construcción de obra civil y de edificación. Además de su elevada resistencia, su carácter dúctil resulta un aspecto de particular interés desde el punto de vista de la seguridad estructural, ya que permite redistribuir esfuerzos a elementos adyacentes y, por tanto, almacenar una mayor energía antes del colapso final de la estructura. No obstante, a pesar de su extendida utilización, todavía existen aspectos relacionados con su comportamiento en rotura que necesitan una mayor clarificación y que permitirían un mejor aprovechamiento de sus propiedades. Cuando un elemento de acero es ensayado a tracción y alcanza la carga máxima, sufre la aparición de un cuello de estricción que plantea dificultades para conocer el comportamiento del material desde dicho instante hasta la rotura. La norma ISO 6892-1, que define el método a emplear en un ensayo de tracción con materiales metálicos, establece procedimientos para determinar los parámetros relacionados con este tramo último de la curva F − E. No obstante, la definición de dichos parámetros resulta controvertida, ya que éstos presentan una baja reproducibilidad y una baja repetibilidad que resultan difíciles de explicar. En esta Tesis se busca profundizar en el conocimiento del último tramo de la curva F − E de los aceros de construcción. Para ello se ha realizado una amplia campaña experimental sobre dos aceros representativos en el campo de la construcción civil: el alambrón de partida empleado en la fabricación de alambres de pretensado y un acero empleado como refuerzo en hormigón armado. Los dos materiales analizados presentan formas de rotura diferentes: mientras el primero de ellos presenta una superficie de rotura plana con una región oscura claramente apreciable en su interior, el segundo rompe según la clásica superficie en forma de copa y cono. La rotura en forma de copa y cono ha sido ampliamente estudiada en el pasado y existen modelos de rotura que han logrado reproducirla con éxito, en especial el modelo de Gurson- Tvergaard-Needleman (GTN). En cuanto a la rotura exhibida por el primer material, en principio nada impide abordar su reproducción numérica con un modelo GTN, sin embargo, las diferencias observadas entre ambos materiales en los ensayos experimentales permiten pensar en otro criterio de rotura. En la presente Tesis se realiza una amplia campaña experimental con probetas cilíndricas fabricadas con dos aceros representativos de los empleados en construcción con comportamientos en rotura diferentes. Por un lado se analiza el alambrón de partida empleado en la fabricación de alambres de pretensado, cuyo frente de rotura es plano y perpendicular a la dirección de aplicación de la carga con una región oscura en su interior. Por otro lado, se estudian barras de acero empleadas como armadura pasiva tipo B 500 SD, cuyo frente de rotura presenta la clásica superficie en forma de copa y cono. Estos trabajos experimentales han permitido distinguir dos comportamientos en rotura claramente diferenciados entre ambos materiales y, en el caso del primer material, se ha identificado un comportamiento asemejable al exhibido por materiales frágiles. En este trabajo se plantea la hipótesis de que el primer material, cuya rotura provoca un frente de rotura plano y perpendicular a la dirección de aplicación de la carga, rompe de manera cuasifrágil como consecuencia de un proceso de decohesión, de manera que la región oscura que se observa en el centro del frente de rotura se asemeja a una entalla circular perpendicular a la dirección de aplicación de la carga. Para la reproducción numérica de la rotura exhibida por el primer material, se plantea un criterio de rotura basado en un modelo cohesivo que, como aspecto novedoso, se hace depender de la triaxialidad de tensiones, parámetro determinante en el fallo de este tipo de materiales. Este tipo de modelos presenta varias ventajas respecto a los modelos GTN habitualmente empleados. Mientras los modelos GTN precisan de numerosos parámetros para su calibración, los modelos cohesivos precisan fundamentalmente de dos parámetros para definir su curva de ablandamiento: la tensión de decohesión ft y la energía de fractura GF . Además, los parámetros de los modelos GTN no son medibles de manera experimental, mientras que GF sí lo es. En cuanto a ft, aunque no existe un método para su determinación experimental, sí resulta un parámetro más fácilmente interpretable que los empleados por los modelos GTN, que utilizan valores como el porcentaje de huecos presentes en el material para iniciar el fenómeno de coalescencia o el porcentaje de poros que provoca una pérdida total de la capacidad resistente. Para implementar este criterio de rotura se ha desarrollado un elemento de intercara cohesivo dependiente de la triaxialidad de tensiones. Se han reproducido con éxito los ensayos de tracción llevados a cabo en la campaña experimental empleando dicho elemento de intercara. Además, en estos modelos la rotura se produce fenomenológicamente de la misma manera observada en los ensayos experimentales: produciéndose una decohesión circular en torno al eje de la probeta. En definitiva, los trabajos desarrollados en esta Tesis, tanto experimentales como numéricos, contribuyen a clarificar el comportamiento de los aceros de construcción en el último tramo de la curva F − E y los mecanismos desencadenantes de la rotura final del material, aspecto que puede contribuir a un mejor aprovechamiento de las propiedades de estos aceros en el futuro y a mejorar la seguridad de las estructuras construidas con ellos. Steel is, together with concrete, the most widely used material in civil engineering works. Not only its high strength, but also its ductility is of special interest from the point of view of the structural safety, since it enables stress distribution with adjacent elements and, therefore, more energy can be stored before reaching the structural failure. However, despite of being extensively used, there are still some aspects related to its fracture behaviour that need to be clarified and that will allow for a better use of its properties. When a steel item is tested under tension and reaches the maximum load point, necking process begins, which makes difficult to define the material behaviour from that moment onward. The ISO standard 6892-1, which defines the tensile testing method for metallic materials, describes the procedures to obtain some parameters related to this last section of the F − E curve. Nevertheless, these parameters have proved to be controversial, since they have low reproducibility and repeatibility rates that are difficult to explain. This Thesis tries to deepen the knowledge of the last section of the F − E curve for construction steels. An extensive experimental campaign has been carried out with two representative steels used in civil engineering works: a steel rod used for manufacturing prestressing steel wires, before the cold-drawing process is applied, and steel bars used in reinforced concrete structures. Both materials have different fracture surfaces: while the first of them shows a flat fracture surface, perpendicular to the loading direction with a dark region in the centre of it, the second one shows the classical cup-cone fracture surface. The cup-cone fracture surface has been deeply studied in the past and different numerical models have been able to reproduce it with success, with a special mention to the Gurson-Tvergaard-Needleman model (GTN). Regarding the failure surface shown by the first material, in principle it can be numerically reproduced by a GTN model, but the differences observed between both materials in the experimental campaign suggest thinking of a different failure criterium. In the present Thesis, an extensive experimental campaign has been carried out using cylindrical specimens made of two representative construction steels with different fracture behaviours. On one hand, the initial eutectoid steel rod used for manufacturing prestressing steel wires is analysed, which presents a flat fracture surface, perpendicular to the loading direction, and with a dark region in the centre of it. On the other hand, B 500 SD steel bars, typically used in reinforced concrete structures and with the typical cup-cone fracture surface, are studied. These experimental works have allowed distinguishing two clearly different fracture behaviours between both materials and, in the case of the first one, a fragile-like behaviour has been identified. For the first material, which shows a flat fracture surface perpendicular to the loading direction, the following hypothesis is proposed in this study: a quasi-brittle fracture is developed as a consequence of a decohesion process, with the dark region acting as a circular crack perpendicular to the loading direction. To reproduce numerically the fracture behaviour shown by the first material, a failure criterium based on a cohesive model is proposed in this Thesis. As an innovative contribution, this failure criterium depends on the stress triaxiality state of the material, which is a key parameter when studying fracture in this kind of materials. This type of models have some advantages when compared to the widely used GTN models. While GTN models need a high number of parameters to be defined, cohesive models need basically two parameters to define the softening curve: the decohesion stress ft and the fracture energy GF . In addition to this, GTN models parameters cannot be measured experimentally, while GF is indeed. Regarding ft, although no experimental procedure is defined for its obtention, it has an easier interpretation than the parameters used by the GTN models like, for instance, the void volume needed for the coalescence process to start or the void volume that leads to a total loss of the bearing capacity. In order to implement this failure criterium, a triaxiality-dependent cohesive interface element has been developed. The experimental results obtained in the experimental campaign have been successfully reproduced by using this interface element. Furthermore, in these models the failure mechanism is developed in the same way as observed experimentally: with a circular decohesive process taking place around the longitudinal axis of the specimen. In summary, the works developed in this Thesis, both experimental and numerical, contribute to clarify the behaviour of construction steels in the last section of the F − E curve and the mechanisms responsible for the eventual material failure, an aspect that can lead to a better use of the properties of these steels in the future and a safety improvement in the structures built with them.
Resumo:
Damage tolerance of high strength cold-drawn ferritic–austenitic stainless steel wires is assessed by means of tensile fracture tests of cracked wires. The fatigue crack is transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behaviour is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D is used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plane specimens extracted from the cold-drawn wires. Finally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic–austenitic stainless steel wires is compared with that of an elementary plastic collapse model and existing data of two types of high strength eutectoid steel currently used as prestressing steel for concrete.
Resumo:
En este trabajo se determina la tolerancia al daño de un acero inoxidable austeno-ferrítico trefilado hasta obtener resistencia propias del acero de pretensado. Para ello se han realizado ensayos de fractura sobre alambres con secciones transversales debilitadas por fisuras de fatiga propagadas desde la superficie exterior. La medida de la tolerancia al daño adoptada es la curva empírica carga de rotura-profundidad de fisura. Para valorar cuantitativamente los resultados, se utilizan las curvas de dos aceros de pretensar eutectoides, respectivamente fabricados por trefilado y por tratamiento térmico de templado y revenido, así como un modelo elemental de colapso plástico por tracción para alambres fisurados. La microestructura austeno-ferrítico de los alambres inoxidables adquiere una marcada orientación en la dirección de trefilado, que induce una fuerte anisotropía de fractura en los alambres y condiciona su mecanismo macroscópico de colapso a tracción cuando están Asurados. Para observar este mecanismo se ha utilizado la técnica VIC-2D de adquisición y análisis computerizado de imágenes digitales en ensayos mecánicos, aplicándola a ensayos de fractura a tracción realizados con probetas planas de alambre inoxidable trefilado Asuradas transversalmente. Damage tolerance of a high strength cold-drawn ferritic-austenitic stainless steel is assessed by means of tensile fracture tests of cracked wires. A fatigue crack was transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behavior is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D was used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plañe specimens extracted from the cold-drawn wires. Additionally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic-austenitic stainless steel wires is compared with that of the two types of high strength eutectoid wires currently used as prestressing steel for concrete. An elementary plástic collapse model for tensile failure of surface cracked wires is used to assess the damage tolerance curves.
Resumo:
A theoretical and numerical framework to model the foundation of marine offshore structures is presented. The theoretical model is composed by a system of partial differential equations describing coupling between seabed solid skeleton and pore fluids (water, air, oil,…) combined with a system of ordinary differential equations describing the specific constitutive relation of the seabed soil skeleton. Once the theoretical model is described, the finite element numerical procedure to achieve an approximate solution of the governing equations is outlined. In order to validate the proposed theoretical and numerical framework the seaward tilt mechanism induced by the action of breaking waves over a vertical breakwater is numerically reproduced. The results numerically attained are in agreement with the main conclusions drawn from the literature associated with this failure mechanism
Resumo:
A quantitative temperature accelerated life test on sixty GaInP/GaInAs/Ge triple-junction commercial concentrator solar cells is being carried out. The final objective of this experiment is to evaluate the reliability, warranty period, and failure mechanism of high concentration solar cells in a moderate period of time. The acceleration of the degradation is realized by subjecting the solar cells at temperatures markedly higher than the nominal working temperature under a concentrator Three experiments at three different temperatures are necessary in order to obtain the acceleration factor which relates the time at the stress level with the time at nominal working conditions. . However, up to now only the test at the highest temperature has finished. Therefore, we can not provide complete reliability information but we have analyzed the life data and the failure mode of the solar cells inside the climatic chamber at the highest temperature. The failures have been all of them catastrophic. In fact, the solar cells have turned into short circuits. We have fitted the failure distribution to a two parameters Weibull function. The failures are wear-out type. We have observed that the busbar and the surrounding fingers are completely deteriorate
Resumo:
More than 20 mega-landslides have been described in the Canary Islands affecting the flanks of the volcanic edifices. Gliimar and La Orotava landslides, in Tenerife, are two exceptional cases due to their huge dimensions and outstanding geomorphological features. The estimated volume of these landslides exceed tens of cubic km. Tsunami deposits have been also identified in some of the islands of the archipelago probably associated to the large landslides of the islands flanks. An investigation has been carried out to explain the causes of these large instability processes and their failure mechanisms. One of the main aspects investigated was the geomechanical characteristics of the volcanic rock masses, specially the hyaloclastite rocks forming the substratum underlying the emerged volcanic building. The low strength and high deformability properties of these rocks have played a fundamental role on the stability of the island flanks. The results have shown the gravitational origin of these instability processes as the main failure mechanism. Volcanic eruptions or large earthquakes could be contributing factors to the instability, but according with the data obtained in Gliimar and La Orotava cases they are not necessary as triggering factors. As a result of the field work carried out in the frame of the project, three large tsunami deposits have been identified in the islands of Lanzarote, Tenerifc and Gran Canaria attributed to rnega-Iandslides, possibly related to Guimar and La Orotava. A Sumrnary of their main features is described.
Resumo:
El frente de un túnel puede colapsar si la presión aplicada sobre el es inferior a un valor limite denominado presión “critica” o “de colapso”. En este trabajo se desarrolla y presenta un mecanismo de rotura rotacional generado punto a punto para el cálculo de la presión de colapso del frente de túneles excavados en terrenos estratificados o en materiales que siguen un criterio de rotura nolineal. La solución propuesta es una solución de contorno superior en el marco del Análisis Límite y supone una generalización del mecanismo de rotura mas reciente existente en la bibliografía. La presencia de un terreno estratificado o con un criterio de rotura no-lineal implica una variabilidad espacial de las propiedades resistentes. Debido a esto, se generaliza el mecanismo desarrollado por Mollon et al. (2011b) para suelos, de tal forma que se puedan considerar valores locales del ángulo de rozamiento y de la cohesión. Además, la estratificación del terreno permite una rotura parcial del frente, por lo que se implementa esta posibilidad en el mecanismo, siendo la primera solución que emplea un mecanismo de rotura que se ajusta a la estratigrafía del terreno. Por otro lado, la presencia de un material con un criterio de rotura no-lineal exige introducir en el modelo, como variable de estudio, el estado tensional en el frente, el cual se somete al mismo proceso de optimización que las variables geométricas del mecanismo. Se emplea un modelo numérico 3D para validar las predicciones del mecanismo de Análisis Limite, demostrando que proporciona, con un esfuerzo computacional significativamente reducido, buenas predicciones de la presión critica, del tipo de rotura (global o parcial) en terrenos estratificados y de la geometría de fallo. El mecanismo validado se utiliza para realizar diferentes estudios paramétricos sobre la influencia de la estratigrafía en la presión de colapso. Igualmente, se emplea para elaborar cuadros de diseño de la presión de colapso para túneles ejecutados con tuneladora en macizos rocosos de mala calidad y para analizar la influencia en la estabilidad del frente del método constructivo. Asimismo, se lleva a cabo un estudio de fiabilidad de la estabilidad del frente de un túnel excavado en un macizo rocoso altamente fracturado. A partir de el se analiza como afectan las diferentes hipótesis acerca de los tipos de distribución y de las estructuras de correlación a los resultados de fiabilidad. Se investiga también la sensibilidad de los índices de fiabilidad a los cambios en las variables aleatorias, identificando las mas relevantes para el diseño. Por ultimo, se lleva a cabo un estudio experimental mediante un modelo de laboratorio a escala reducida. El modelo representa medio túnel, lo cual permite registrar el movimiento del material mediante una técnica de correlación de imágenes fotográficas. El ensayo se realiza con una arena seca y se controla por deformaciones mediante un pistón que simula el frente. Los resultados obtenidos se comparan con las estimaciones de la solución de Análisis Límite, obteniéndose un ajuste razonable, de acuerdo a la literatura, tanto en la geometría de rotura como en la presión de colapso. A tunnel face may collapse if the applied support pressure is lower than a limit value called the ‘critical’ or ‘collapse’ pressure. In this work, an advanced rotational failure mechanism generated ‘‘point-by-point” is developed to compute the collapse pressure for tunnel faces in layered (or stratified) grounds or in materials that follow a non-linear failure criterion. The proposed solution is an upper bound solution in the framework of limit analysis which extends the most advanced face failure mechanism in the literature. The excavation of the tunnel in a layered ground or in materials with a non-linear failure criterion may lead to a spatial variability of the strength properties. Because of this, the rotational mechanism recently proposed by Mollon et al. (2011b) for Mohr-Coulomb soils is generalized so that it can consider local values of the friction angle and of the cohesion. For layered soils, the mechanism needs to be extended to consider the possibility for partial collapse. The proposed methodology is the first solution with a partial collapse mechanism that can fit to the stratification. Similarly, the use of a nonlinear failure criterion introduces the need to introduce new parameters in the optimization problem to consider the distribution of normal stresses along the failure surface. A 3D numerical model is employed to validate the predictions of the limit analysis mechanism, demonstrating that it provides, with a significantly reduced computational effort, good predictions of critical pressure, of the type of collapse (global or partial) in layered soils, and of its geometry. The mechanism is then employed to conduct parametric studies of the influence of several geometrical and mechanical parameters on face stability of tunnels in layered soils. Similarly, the methodology has been further employed to develop simple design charts that provide the face collapse pressure of tunnels driven by TBM in low quality rock masses and to study the influence of the construction method. Finally, a reliability analysis of the stability of a tunnel face driven in a highly fractured rock mass is performed. The objective is to analyze how different assumptions about distributions types and correlation structures affect the reliability results. In addition, the sensitivity of the reliability index to changes in the random variables is studied, identifying the most relevant variables for engineering design. Finally, an experimental study is carried out using a small-scale laboratory model. The problem is modeled in half, cutting through the tunnel axis vertically, so that displacements of soil particles can be recorded by a digital image correlation technique. The tests were performed with dry sand and displacements are controlled by a piston that supports the soil. The results of the model are compared with the predictions of the Limit Analysis mechanism. A reasonable agreement, according to literature, is obtained between the shapes of the failure surfaces and between the collapse pressures observed in the model tests and computed with the analytical solution.
Resumo:
The fracture behavior of rock block contacts has been studied for many years. Unfortunately, up to now, there is not a rigorous formulation or a solid theoretical foundation to support it. A mathematical development to represent the failure mechanism which occurs in the contacts between rock blocks is presented to evaluate the performance of breaking mechanism of such blocks relating it to the morphology of the contact and mechanical parameters of the material. The examined framework includes the evaluation of the surface roughness of first order in the failure mechanism of the granular particles of large size and the development of a theoretical model describing the morphology of the contact between rock blocks.
Resumo:
Current design practices recommend to comply with the capacity protection principle, which pays special attention to ensuring an elastic response of the foundations under ground motion events. However, in cases such as elevated reinforced concrete (RC) pile-cap foundation typologies, this design criterion may lead to conservative designs, with excessively high construction costs. Reinforced concrete elevated pile-cap foundations is a system formed by a group of partially embedded piles connected through an aboveground stayed cap and embedded in soil. In the cases when they are subjected to ground motions, the piles suffer large bending moments that make it difficult to maintain their behavior within the elastic range of deformations. Aiming to make an in-depth analysis of the nonlinear behavior of elevated pile-cap foundations, a cyclic loading test was performed on a concrete 2x3 pile configuration specimen of elevated pile-cap foundation. Two results of this test, the failure mechanism and the ductile behavior, were used for the calibration of a numerical model built in OpenSees framework, by using a pushover analysis. The calibration of the numerical model enabled an in-depth study of the seismic nonlinear response of this kind of foundations. A parametric analysis was carried for this purpose, aiming to study how sensitive RC elevated pile-cap foundations are, when subjected to variations in the diameter of piles, reinforcement ratios, external loads, soil density or multilayer configurations. This analysis provided a set of ductility factors that can be used as a reference for design practices and which correspond to each of the cases analyzed.
Resumo:
En España existen del orden de 1,300 grandes presas, de las cuales un 20% fueron construidas antes de los años 60. El hecho de que existan actualmente una gran cantidad de presas antiguas aún en operación, ha producido un creciente interés en reevaluar su seguridad empleando herramientas nuevas o modificadas que incorporan modelos de fallo teóricos más completos, conceptos geotécnicos más complejos y nuevas técnicas de evaluación de la seguridad. Una manera muy común de abordar el análisis de estabilidad de presas de gravedad es, por ejemplo, considerar el deslizamiento a través de la interfase presa-cimiento empleando el criterio de rotura lineal de Mohr-Coulomb, en donde la cohesión y el ángulo de rozamiento son los parámetros que definen la resistencia al corte de la superficie de contacto. Sin embargo la influencia de aspectos como la presencia de planos de debilidad en el macizo rocoso de cimentación; la influencia de otros criterios de rotura para la junta y para el macizo rocoso (ej. el criterio de rotura de Hoek-Brown); las deformaciones volumétricas que ocurren durante la deformación plástica en el fallo del macizo rocoso (i.e., influencia de la dilatancia) no son usualmente consideradas durante el diseño original de la presa. En este contexto, en la presente tesis doctoral se propone una metodología analítica para el análisis de la estabilidad al deslizamiento de presas de hormigón, considerando un mecanismo de fallo en la cimentación caracterizado por la presencia de una familia de discontinuidades. En particular, se considera la posibilidad de que exista una junta sub-horizontal, preexistente y persistente en el macizo rocoso de la cimentación, con una superficie potencial de fallo que se extiende a través del macizo rocoso. El coeficiente de seguridad es entonces estimado usando una combinación de las resistencias a lo largo de los planos de rotura, cuyas resistencias son evaluadas empleando los criterios de rotura no lineales de Barton y Choubey (1977) y Barton y Bandis (1990), a lo largo del plano de deslizamiento de la junta; y el criterio de rotura de Hoek y Brown (1980) en su versión generalizada (Hoek et al. 2002), a lo largo del macizo rocoso. La metodología propuesta también considera la influencia del comportamiento del macizo rocoso cuando este sigue una ley de flujo no asociada con ángulo de dilatancia constante (Hoek y Brown 1997). La nueva metodología analítica propuesta es usada para evaluar las condiciones de estabilidad empleando dos modelos: un modelo determinista y un modelo probabilista, cuyos resultados son el valor del coeficiente de seguridad y la probabilidad de fallo al deslizamiento, respectivamente. El modelo determinista, implementado en MATLAB, es validado usando soluciones numéricas calculadas mediante el método de las diferencias finitas, empleando el código FLAC 6.0. El modelo propuesto proporciona resultados que son bastante similares a aquellos calculados con FLAC; sin embargo, los costos computacionales de la formulación propuesta son significativamente menores, facilitando el análisis de sensibilidad de la influencia de los diferentes parámetros de entrada sobre la seguridad de la presa, de cuyos resultados se obtienen los parámetros que más peso tienen en la estabilidad al deslizamiento de la estructura, manifestándose además la influencia de la ley de flujo en la rotura del macizo rocoso. La probabilidad de fallo es obtenida empleando el método de fiabilidad de primer orden (First Order Reliability Method; FORM), y los resultados de FORM son posteriormente validados mediante simulaciones de Monte Carlo. Los resultados obtenidos mediante ambas metodologías demuestran que, para el caso no asociado, los valores de probabilidad de fallo se ajustan de manera satisfactoria a los obtenidos mediante las simulaciones de Monte Carlo. Los resultados del caso asociado no son tan buenos, ya que producen resultados con errores del 0.7% al 66%, en los que no obstante se obtiene una buena concordancia cuando los casos se encuentran en, o cerca de, la situación de equilibrio límite. La eficiencia computacional es la principal ventaja que ofrece el método FORM para el análisis de la estabilidad de presas de hormigón, a diferencia de las simulaciones de Monte Carlo (que requiere de al menos 4 horas por cada ejecución) FORM requiere tan solo de 1 a 3 minutos en cada ejecución. There are 1,300 large dams in Spain, 20% of which were built before 1960. The fact that there are still many old dams in operation has produced an interest of reevaluate their safety using new or updated tools that incorporate state-of-the-art failure modes, geotechnical concepts and new safety assessment techniques. For instance, for gravity dams one common design approach considers the sliding through the dam-foundation interface, using a simple linear Mohr-Coulomb failure criterion with constant friction angle and cohesion parameters. But the influence of aspects such as the persistence of joint sets in the rock mass below the dam foundation; of the influence of others failure criteria proposed for rock joint and rock masses (e.g. the Hoek-Brown criterion); or the volumetric strains that occur during plastic failure of rock masses (i.e., the influence of dilatancy) are often no considered during the original dam design. In this context, an analytical methodology is proposed herein to assess the sliding stability of concrete dams, considering an extended failure mechanism in its rock foundation, which is characterized by the presence of an inclined, and impersistent joint set. In particular, the possibility of a preexisting sub-horizontal and impersistent joint set is considered, with a potential failure surface that could extend through the rock mass; the safety factor is therefore computed using a combination of strength along the rock joint (using the nonlinear Barton and Choubey (1977) and Barton and Bandis (1990) failure criteria) and along the rock mass (using the nonlinear failure criterion of Hoek and Brown (1980) in its generalized expression from Hoek et al. (2002)). The proposed methodology also considers the influence of a non-associative flow rule that has been incorporated using a (constant) dilation angle (Hoek and Brown 1997). The newly proposed analytical methodology is used to assess the dam stability conditions, employing for this purpose the deterministic and probabilistic models, resulting in the sliding safety factor and the probability of failure respectively. The deterministic model, implemented in MATLAB, is validated using numerical solution computed with the finite difference code FLAC 6.0. The proposed deterministic model provides results that are very similar to those computed with FLAC; however, since the new formulation can be implemented in a spreadsheet, the computational cost of the proposed model is significantly smaller, hence allowing to more easily conduct parametric analyses of the influence of the different input parameters on the dam’s safety. Once the model is validated, parametric analyses are conducting using the main parameters that describe the dam’s foundation. From this study, the impact of the more influential parameters on the sliding stability analysis is obtained and the error of considering the flow rule is assessed. The probability of failure is obtained employing the First Order Reliability Method (FORM). The probabilistic model is then validated using the Monte Carlo simulation method. Results obtained using both methodologies show good agreement for cases in which the rock mass has a nonassociate flow rule. For cases with an associated flow rule errors between 0.70% and 66% are obtained, so that the better adjustments are obtained for cases with, or close to, limit equilibrium conditions. The main advantage of FORM on sliding stability analyses of gravity dams is its computational efficiency, so that Monte Carlo simulations require at least 4 hours on each execution, whereas FORM requires only 1 to 3 minutes on each execution.
Resumo:
A temperature accelerated life test on concentrator lattice mismatched Ga0.37In0.63P/Ga0.83In0.17As/Ge triple-junction solar cells-on-carrier is being carried out. The solar cells have been tested at three different temperatures: 125, 145 and 165°C and the nominal photo-current condition (500X) is emulated by injecting current in darkness. The final objective of these tests is to evaluate the reliability, warranty period, and failure mechanism of these solar cells in a moderate period of time. Up to now only the test at 165°C has finished. Therefore, we cannot provide complete reliability information, but we have carried out preliminary data and failure analysis with the current results.
Resumo:
The popularity of MapReduce programming model has increased interest in the research community for its improvement. Among the other directions, the point of fault tolerance, concretely the failure detection issue seems to be a crucial one, but that until now has not reached its satisfying level. Motivated by this, I decided to devote my main research during this period into having a prototype system architecture of MapReduce framework with a new failure detection service, containing both analytical (theoretical) and implementation part. I am confident that this work should lead the way for further contributions in detecting failures to any NoSQL App frameworks, and cloud storage systems in general.