Resumo:
The adhesives used for applications in marine environments are subject to particular chemical conditions, which are mainly characterised by an elevated chlorine ion content and intermittent wetting/drying cycles, among others.These conditions can limit the use of adhesives due to the degradation processes that they experience. In this work, the chemical degradation of two different polymers, polyurethane and vinylester, was studied in natural seawater under immersion for different periods of time.The diffusion coefficients and concentration profiles of water throughout the thickness of the adhesiveswere obtained.Microstructural changes in the polymer due to the action of water were observed by SEM, and the chemical degradation of the polymer was monitored with the Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC). The degradation of the mechanical properties of the adhesive was determined by creep tests withMixed Cantilever Beam (MCB) specimens at different temperatures. After 180 days of immersion of the specimens, it was concluded that the J-integral value (depending on the strain) implies a loss of stiffness of 51% and a decrease in the failure load of 59% for the adhesive tested.
Resumo:
Damage tolerance of high strength cold-drawn ferritic–austenitic stainless steel wires is assessed by means of tensile fracture tests of cracked wires. The fatigue crack is transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behaviour is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D is used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plane specimens extracted from the cold-drawn wires. Finally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic–austenitic stainless steel wires is compared with that of an elementary plastic collapse model and existing data of two types of high strength eutectoid steel currently used as prestressing steel for concrete.
Resumo:
En este trabajo se determina la tolerancia al daño de un acero inoxidable austeno-ferrítico trefilado hasta obtener resistencia propias del acero de pretensado. Para ello se han realizado ensayos de fractura sobre alambres con secciones transversales debilitadas por fisuras de fatiga propagadas desde la superficie exterior. La medida de la tolerancia al daño adoptada es la curva empírica carga de rotura-profundidad de fisura. Para valorar cuantitativamente los resultados, se utilizan las curvas de dos aceros de pretensar eutectoides, respectivamente fabricados por trefilado y por tratamiento térmico de templado y revenido, así como un modelo elemental de colapso plástico por tracción para alambres fisurados. La microestructura austeno-ferrítico de los alambres inoxidables adquiere una marcada orientación en la dirección de trefilado, que induce una fuerte anisotropía de fractura en los alambres y condiciona su mecanismo macroscópico de colapso a tracción cuando están Asurados. Para observar este mecanismo se ha utilizado la técnica VIC-2D de adquisición y análisis computerizado de imágenes digitales en ensayos mecánicos, aplicándola a ensayos de fractura a tracción realizados con probetas planas de alambre inoxidable trefilado Asuradas transversalmente. Damage tolerance of a high strength cold-drawn ferritic-austenitic stainless steel is assessed by means of tensile fracture tests of cracked wires. A fatigue crack was transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behavior is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D was used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plañe specimens extracted from the cold-drawn wires. Additionally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic-austenitic stainless steel wires is compared with that of the two types of high strength eutectoid wires currently used as prestressing steel for concrete. An elementary plástic collapse model for tensile failure of surface cracked wires is used to assess the damage tolerance curves.
Resumo:
Gran parte del patrimonio construido cuenta con edificios cuya estructura está compuesta por elementos de madera. El volumen económico que supone el mantenimiento y renovación de dicho patrimonio es considerable, por ello, es de especial interés el estudio de las diferentes técnicas de refuerzo aplicables a este tipo de estructuras. Las estructuras de madera han sido tradicionalmente reforzadas con piezas del mismo material, aumentando la sección de los elementos dañados, o con acero. La aparición de los materiales compuestos de polímeros reforzados con fibras, y su progresiva aplicación en obras de construcción, hizo que a principios de la década de los noventa se comenzara a aplicar este material en refuerzos de estructuras de madera (Puente de Sins, 1992). La madera es un material natural con una excelente relación entre sus características mecánicas y su peso. Con el uso de materiales compuestos como refuerzo ésta característica se mantiene. En cuanto a su modelo constitutivo, se admite un comportamiento elástico lineal a tracción paralela a la fibra hasta la rotura, mientras que a compresión, se considera un comportamiento lineal elástico inicial, seguido de un tramo plástico. En vigas de madera aserrada sometidas a flexión predomina el modo de fallo por tracción localizándose la fractura frecuentemente en el canto inferior. Los FRP tienen un comportamiento elástico lineal a tracción hasta la rotura y cuentan con excelentes propiedades mecánicas en relación a su peso y volumen. Si se refuerza la viga por el canto inferior se aumentará su capacidad de absorber tracciones y por tanto, es previsible que se produzca un incremento en la capacidad de carga, así como un aumento de ductilidad. En este trabajo se analizan los beneficios que aportan distintos sistemas de refuerzos de materiales compuestos. El objetivo es contribuir al conocimiento de esta técnica para la recuperación o aumento de las propiedades resistentes de elementos de madera sometidos a flexión. Se ha llevado a cabo un estudio basado en datos obtenidos experimentalmente mediante el ensayo a flexión de vigas de madera de pino silvestre reforzadas con materiales compuestos. Las fibras que componen los tejidos utilizados para la ejecución de los refuerzos son de basalto y de carbono. En el caso de los compuestos de fibra de basalto se aplican en distintos gramajes, y los de carbono en tejido unidireccional y bidireccional. Se analiza el comportamiento de las vigas según las variables de refuerzo aplicadas y se comparan con los resultados de vigas ensayadas sin reforzar. Además se comprueba el ajuste del modelo de cálculo no lineal aplicado para predecir la carga de rotura de cada viga reforzada. Con este trabajo queda demostrado el buen funcionamiento del FRP de fibra de basalto aplicado en el refuerzo de vigas de madera y de los tejidos de carbono bidireccionales con respecto a los unidireccionales. ABSTRACT Many of the buildings of the built heritage include a structure composed by timber elements. The economic volume involved in the maintenance and renewal of this built heritage is considerable, therefore, the study of the different reinforcement techniques applicable to this type of structure is of special interest. The wooden structures have traditionally been reinforced either with steel or with pieces of the same material, increasing the section of the damaged parts. The emergence of polymer composites reinforced with fibers, and their progressive use in construction, started to be applied as reinforcement in timber structures at the beginning of the nineties decade in the 20th century (Sins Bridge, 1992). Wood is a natural material with an excellent ratio between its mechanic characteristics and its weight. This feature is maintained with the use of composites as reinforcement. In terms of its constitutive model, linear elastic behavior parallel to the fiber up to fracture is admitted when subjected to tensile stress, while under compression, an initial linear elastic behavior, followed by a section plasticizing, is considered. In sawn timber beams subjected to bending, the predominant failure is mainly due to tensile stress; and frequently the fracture is located at the beam lower face. The FRP have a linear elastic behavior until fracture occurs, and have excellent mechanical properties in relation to their weight and volume. If the beam is reinforced by its lower face, its capacity to absorb tensile stresses will increase, and therefore, an increase in its carrying capacity is likely to be produced, as well as an increase in ductility. This work analyzes the benefits different reinforcement systems of composite materials provide, with the aim of contributing to the knowledge of this technique for recovering or increasing the strength properties of timber elements subjected to bending loads. It is a study based on data obtained experimentally using bending tests of pine timber beams reinforced with composite materials. Fibers used for the execution of the reinforcement are basalt and carbon. Basalt fiber composites are applied in different grammages, whereas with carbon composites, unidirectional and bidirectional fabrics are used. The behavior of the beams was analyzed regarding the reinforcement variables applied, and the results are compared with those of the tested beams without reinforcement. Furthermore it has been proved adjunting the nonlinear calculation model applied to predict the failure load of each reinforced beam. This work proves the good behavior of fiber reinforce plastic (FRP) with basalt fiber when applied to timber beams, and that of bidirectional carbon fabrics as opposed to the unidirectional ones.
Condicionantes de la adherencia y anclaje en el refuerzo de muros de fábrica con elementos de fibras
Resumo:
Es cada vez más frecuente la rehabilitación de patrimonio construido, tanto de obras deterioradas como para la adecuación de obras existentes a nuevos usos o solicitaciones. Se ha considerado el estudio del refuerzo de obras de fábrica ya que constituyen un importante número dentro del patrimonio tanto de edificación como de obra civil (sistemas de muros de carga o en estructuras principales porticadas de acero u hormigón empleándose las fábricas como cerramiento o distribución con elementos autoportantes). A la hora de reparar o reforzar una estructura es importante realizar un análisis de las deficiencias, caracterización mecánica del elemento y solicitaciones presentes o posibles; en el apartado 1.3 del presente trabajo se refieren acciones de rehabilitación cuando lo que se precisa no es refuerzo estructural, así como las técnicas tradicionales más habituales para refuerzo de fábricas que suelen clasificarse según se trate de refuerzos exteriores o interiores. En los últimos años se ha adoptado el sistema de refuerzo de FRP, tecnología con origen en los refuerzos de hormigón tanto de elementos a flexión como de soportes. Estos refuerzos pueden ser de láminas adheridas a la fábrica soporte (SM), o de barras incluidas en rozas lineales (NSM). La elección de un sistema u otro depende de la necesidad de refuerzo y tipo de solicitación predominante, del acceso para colocación y de la exigencia de impacto visual. Una de las mayores limitaciones de los sistemas de refuerzo por FRP es que no suele movilizarse la resistencia del material de refuerzo, produciéndose previamente fallo en la interfase con el soporte con el consecuente despegue o deslaminación; dichos fallos pueden tener un origen local y propagarse a partir de una discontinuidad, por lo que es preciso un tratamiento cuidadoso de la superficie soporte, o bien como consecuencia de una insuficiente longitud de anclaje para la transferencia de los esfuerzos en la interfase. Se considera imprescindible una caracterización mecánica del elemento a reforzar. Es por ello que el trabajo presenta en el capítulo 2 métodos de cálculo de la fábrica soporte de distintas normativas y también una formulación alternativa que tiene en cuenta la fábrica histórica ya que su caracterización suele ser más complicada por la heterogeneidad y falta de clasificación de sus materiales, especialmente de los morteros. Una vez conocidos los parámetros resistentes de la fábrica soporte es posible diseñar el refuerzo; hasta la fecha existe escasa normativa de refuerzos de FRP para muros de fábrica, consistente en un protocolo propuesto por la ACI 440 7R-10 que carece de mejoras por tipo de anclaje y aporta valores muy conservadores de la eficacia del refuerzo. Como se ha indicado, la problemática principal de los refuerzos de FRP en muros es el modo de fallo que impide un aprovechamiento óptimo de las propiedades del material. Recientemente se están realizando estudios con distintos métodos de anclaje para estos refuerzos, con lo que se incremente la capacidad última y se mantenga el soporte ligado al refuerzo tras la rotura. Junto con sistemas de anclajes por prolongación del refuerzo (tanto para láminas como para barras) se han ensayado anclajes con llaves de cortante, barras embebidas, o anclajes mecánicos de acero o incluso de FRP. Este texto resume, en el capítulo 4, algunas de las campañas experimentales llevadas a cabo entre los años 2000 y 2013 con distintos anclajes. Se observan los parámetros fundamentales para medir la eficacia del anclajes como son: el modo de fallo, el incremento de resistencia, y los desplazamientos que permite observar la ductilidad del refuerzo; estos datos se analizan en función de la variación de: tipo de refuerzo incluyéndose el tipo de fibra y sistema de colocación, y tipo de anclaje. Existen también parámetros de diseño de los propios anclajes. En el caso de barras embebidas se resumen en diámetro y material de la barra, acabado superficial, dimensiones y forma de la roza, tipo de adhesivo. En el caso de anclajes de FRP tipo pasador la caracterización incluye: tipo de fibra, sistema de fabricación del anclajes y diámetro del mismo, radio de expansión del abanico, espaciamiento longitudinal de anclajes, número de filas de anclajes, número de láminas del refuerzo, longitud adherida tras el anclaje; es compleja la sistematización de resultados de los autores de las campañas expuestas ya que algunos de estos parámetros varían impidiendo la comparación. El capítulo 5 presenta los ensayos empleados para estas campañas de anclajes, distinguiéndose entre ensayos de modo I, tipo tracción directa o arrancamiento, que servirían para sistemas NSM o para cuantificar la resistencia individual de anclajes tipo pasador; ensayos de modo II, tipo corte simple, que se asemeja más a las condiciones de trabajo de los refuerzos. El presente texto se realiza con objeto de abrir una posible investigación sobre los anclajes tipo pasador, considerándose que junto con los sistemas de barra embebida son los que permiten una mayor versatilidad de diseño para los refuerzos de FRP y siendo su eficacia aún difícil de aislar por el número de parámetros de diseño. Rehabilitation of built heritage is becoming increasingly frequent, including repair of damaged works and conditioning for a new use or higher loads. In this work it has been considered the study of masonry wall reinforcement, as most buildings and civil works have load bearing walls or at least infilled masonry walls in concrete and steel structures. Before repairing or reinforcing an structure, it is important to analyse its deficiencies, its mechanical properties and both existing and potential loads; chapter 1, section 4 includes the most common rehabilitation methods when structural reinforcement is not needed, as well as traditional reinforcement techniques (internal and external reinforcement) In the last years the FRP reinforcement system has been adopted for masonry walls. FRP materials for reinforcement were initially used for concrete pillars and beams. FRP reinforcement includes two main techniques: surface mounted laminates (SM) and near surface mounted bars (NSM); one of them may be more accurate according to the need for reinforcement and main load, accessibility for installation and aesthetic requirements. One of the main constraints of FRP systems is not reaching maximum load for material due to premature debonding failure, which can be caused by surface irregularities so surface preparation is necessary. But debonding (or delamination for SM techniques) can also be a consequence of insufficient anchorage length or stress concentration. In order to provide an accurate mechanical characterisation of walls, chapter 2 summarises the calculation methods included in guidelines as well as alternative formulations for old masonry walls as historic wall properties are more complicated to obtain due to heterogeneity and data gaps (specially for mortars). The next step is designing reinforcement system; to date there are scarce regulations for walls reinforcement with FRP: ACI 440 7R-10 includes a protocol without considering the potential benefits provided by anchorage devices and with conservative values for reinforcement efficiency. As noted above, the main problem of FRP masonry walls reinforcement is failure mode. Recently, some authors have performed studies with different anchorage systems, finding that these systems are able to delay or prevent debonding . Studies include the following anchorage systems: Overlap, embedded bars, shear keys, shear restraint and fiber anchors. Chapter 4 briefly describes several experimental works between years 2000 and 2013, concerning different anchorage systems. The main parameters that measure the anchorage efficiency are: failure mode, failure load increase, displacements (in order to evaluate the ductility of the system); all these data points strongly depend on: reinforcement system, FRP fibers, anchorage system, and also on the specific anchorage parameters. Specific anchorage parameters are a function of the anchorage system used. The embedded bar system have design variables which can be identified as: bar diameter and material, surface finish, groove dimensions, and adhesive. In FRP anchorages (spikes) a complete design characterisation should include: type of fiber, manufacturing process, diameter, fan orientation, anchor splay width, anchor longitudinal spacing and number or rows, number or FRP sheet plies, bonded length beyond anchorage devices,...the parameters considered differ from some authors to others, so the comparison of results is quite complicated. Chapter 5 includes the most common tests used in experimental investigations on bond-behaviour and anchorage characterisation: direct shear tests (with variations single-shear and double-shear), pullout tests and bending tests. Each of them may be used according to the data needed. The purpose of this text is to promote further investigation of anchor spikes, accepting that both FRP anchors and embedded bars are the most versatile anchorage systems of FRP reinforcement and considering that to date its efficiency cannot be evaluated as there are too many design uncertainties.
Resumo:
En el presente trabajo se estudia la sensibilidad a las entallas suaves de alambres de acero inoxidable dúplex fuertemente trefilado. Las entallas consideradas son reducciones de la sección transversal del alambre no simétricas respecto al eje de revolución. Tras constatar experimentalmente que los alambres con este tipo de daño fallan por agotamiento plástico, se ha determinado numéricamente la carga de agotamiento plástico en función de la profundidad de entalla empleando un mode-lo computacional de elementos finitos. Los resultados numéricos indican que la mayor deformabilidad del alambre debida a la entalla actúa en favor de su tolerancia al daño y permite que ésta alcance el límite superior dado por la carga de agotamiento a tracción simple del ligamento resistente.This research deals with the sensitivity to blunt notches of highly cold-drawn wires made of dúplex stainless steel. The analyzed notches are actually reductions of the wire cross section, asymmetrically mechanized with respect to the longitudinal wire axis. Once experimentally verified that the notched wires fail by plástic collapse, the failure load was found as a function of notch depth by means of a finite element model. The numerical results show that the higher compliance of the wires provided by the notch increases their damage tolerance up to the upper bound given by the tensile plástic failure load of the notch ligament.
Resumo:
Entre los requisitos que deben cumplir las estructuras se debe garantizar que estas posean la durabilidad necesaria para permanecer en servicio a lo largo de todo el periodo de vida útil para el que han sido proyectadas. Para conseguir este objetivo las normativas han ido incorporando prescripciones para el diseño del hormigón, en base a distintas clases de exposición dependiendo del origen y magnitud de la agresividad exterior. En ambientes con una elevada agresividad, una de las comprobaciones que debe cumplir el hormigón es que tenga una permeabilidad inferior a los valores máximos fijados según la clase de exposición, y que en caso de considerar como ensayo de referencia el de penetración de agua, analiza el frente de penetración limitando las profundidades de penetración media y máxima. Adicionalmente a las condiciones de diseño según el tipo de ambiente, principalmente basadas en la dosificación del hormigón en términos de la relación agua/cemento y el mínimo contenido de cemento y el recubrimiento de las armaduras, durante la vida en servicio las estructuras pueden están solicitadas por distintas acciones imprevistas que pueden provocar cambios en la microestructura interna del hormigón que modifican su permeabilidad y resistencia, y por tanto pueden alterar la durabilidad inicialmente prevista. Es conocido el efecto de cansancio del hormigón cuando está solicitado por cargas de compresión mantenidas en el tiempo, provocando bajas en su resistencia debido al incremento de la microfisuración. Dada la relación entre la permeabilidad y la microfisuración del hormigón, es previsible el aumento de la permeabilidad en hormigones que han sido precomprimidos durante un periodo largo de tiempo. Los estudios de la permeabilidad en hormigones previamente comprimidos se han realizado analizando periodos de tiempo de compresión cortos que no permiten evaluar el efecto del cansancio sobre la permeabilidad. La presente tesis doctoral investiga la permeabilidad y resistencia a tracción en hormigones que previamente han sido comprimidos en carga mantenida durante distintos plazos de tiempo, al objeto de conocer su evolución en base al tiempo de precompresión. La investigación se apoya en el estudio de otras dos variables como son el tipo de hormigón de acuerdo a su dosificación según el tipo de ambiente considerando una agresividad baja, media o alta, y el grado de compresión aplicado respecto de su carga última de rotura. En los resultados del plan experimental desarrollado se ha obtenido que la permeabilidad presenta un incremento significante con el tiempo de precompresión, que dependiendo del valor inicial de la permeabilidad que tiene el hormigón puede provocar que hormigones que previamente satisfacen las limitaciones de permeabilidad pasen a incumplirlas, pudiendo afectar a su durabilidad. También se confirma la influencia del tiempo de precompresión sobre la resistencia a tracción obteniendo bajas de resistencia importantes en los casos pésimos ensayados, que deben ser tenidas en consideración en tanto afectan a la capacidad resistente del hormigón como a otros aspectos fundamentales como el anclaje de las armaduras en el hormigón armado y pretensado. One of the requirements that structures must meet is to guarantee their durability to remain in service throughout all the working life period for which they have been designed. To achieve this goal, building standards and codes have included specifications for the design of concrete structures, based on different exposure classes depending on the environmental conditions and their origin and magnitude. In severe aggressive environments, one of the specifications the concrete must meet is to have a permeability lower than the maximum values set for a certain exposure class. If this parameter is referenced to water penetration on specimens, then the average and maximum depths of front penetration are analyzed. In addition to the design conditions depending on the exposure class, which regulate the dosage of concrete in terms of the water/cement ratio, minimum samples that have been pre-compressed for a long period of time. Previous studies on permeability have been carried on pre-compressed concrete elements analyzing short periods of time. However, they have not studied the effects of compression forces on concrete in the long term. This Thesis investigates permeability and tensile strength of concrete samples that have been previously compressed under loads applied for different periods of time. The goal is to understand its evolution based on the time exposed to compression. The research variables also include the type of concrete according to the dosage used - depending on the environmental exposure it will have low, medium or high aggressiveness-, and the amount of compression applied in relation to its failure load. Results of the experimental tests showed that permeability increases significantly over the time of pre-compression. Depending on the initial value of permeability, this change could make the concrete not meet the original permeability restrictions and therefore affect its durability. These investigations also confirmed the influence of time of pre-compression in tensile strength, where some cases showed a significant decrease of resistance. These issues must be taken into consideration as they affect the bearing capacity of the material and other key features such as the anchoring of steel bars in reinforced and pre-stressed concrete. amount of cement content and the minimum concrete cover of the steel bars, during their working life structures may be subject to various unforeseen actions. As a result, the concrete’s internal microstructure might be affected, changing its permeability and resistance, and possibly altering the original specified durability. It is a known fact that when concrete is loaded in compression maintained over a long time, its resistance to compression forces is diminished due to the increase in micro-cracking. Considering the relationship between permeability and microcracking of concrete, an increase in permeability may be expected in concrete
Resumo:
A finite element model was used to simulate timberbeams with defects and predict their maximum load in bending. Taking into account the elastoplastic constitutive law of timber, the prediction of fracture load gives information about the mechanisms of timber failure, particularly with regard to the influence of knots, and their local graindeviation, on the fracture. A finite element model was constructed using the ANSYS element Plane42 in a plane stress 2D-analysis, which equates thickness to the width of the section to create a mesh which is as uniform as possible. Three sub-models reproduced the bending test according to UNE EN 408: i) timber with holes caused by knots; ii) timber with adherent knots which have structural continuity with the rest of the beam material; iii) timber with knots but with only partial contact between knot and beam which was artificially simulated by means of contact springs between the two materials. The model was validated using ten 45 × 145 × 3000 mm beams of Pinus sylvestris L. which presented knots and graindeviation. The fracture stress data obtained was compared with the results of numerical simulations, resulting in an adjustment error less of than 9.7%
Analytical bearing capacity of strip footing in weightless materials with power-law failure criteria
Resumo:
Sokolovskii’s method of characteristics is extended to provide analytical solutions for the ultimate load at the moment of plastic failure under plane-strain conditions of shallow strip foundations on weightless rigid-plastic media with a noncohesive power-law failure envelope. The formulation is made parametrically in terms of the instantaneous friction angle, and the key idea to obtain the bearing capacity is that information can be transmitted from the free surface (where external loads are known) to the contact plane of the foundation. The methodology can consider foundations adjacent to a slope, external surcharges at the free surface, and inclined loads (both on the slope and on the foundation). Sensitivity analyses illustrate the influence on bearing capacity of changes in the different geometrical parameters involved. An application example is presented and design plots are provided, and model predictions are compared with results of bearing capacity tests under low gravity.
Resumo:
We present an optical sensing methodology to estimate the fatigue damage state of structures made of carbon fiber reinforced polymer (CFRP), by measuring variations on the surface roughness. Variable amplitude loads (VAL), which represent realistic loads during aeronautical missions of fighter aircraft (FALSTAFF) have been applied to coupons until failure. Stiffness degradation and surface roughness variations have been measured during the life of the coupons obtaining a Pearson correlation of 0.75 between both variables. The data were compared with a previous study for Constant Amplitude Load (CAL) obtaining similar results. Conclusions suggest that the surface roughness measured in strategic zones is a useful technique for structural health monitoring of CFRP structures, and that it is independent of the type of load applied. Surface roughness can be measured in the field by optical techniques such as speckle, confocal perfilometers and interferometry, among others.