49 resultados para Experimental testing
em Universidad Politécnica de Madrid
Resumo:
This paper presents a simple mathematical model to estimateshadinglosses on PVarrays. The model is applied directly to power calculations, without the need to consider the whole current–voltage curve. This allows the model to be used with common yield estimation software. The model takes into account both the shaded fraction of the array area and the number of blocks (a group of solar cells protected by a bypass diode) affected by shade. The results of an experimental testing campaign on several shaded PVarrays to check the validity of model are also reported.
Resumo:
This paper presents a simple mathematical model to estimate shading losses on PV arrays. The model is applied directly to power calculations, without the need to consider the whole current–voltage curve. This allows the model to be used with common yield estimation software. The model takes into account both the shaded fraction of the array area and the number of blocks (a group of solar cells protected by a bypass diode) affected by shade. The results of an experimental testing campaign on several shaded PV arrays to check the validity of model are also reported.
Resumo:
This thesis deals with the problem of efficiently tracking 3D objects in sequences of images. We tackle the efficient 3D tracking problem by using direct image registration. This problem is posed as an iterative optimization procedure that minimizes a brightness error norm. We review the most popular iterative methods for image registration in the literature, turning our attention to those algorithms that use efficient optimization techniques. Two forms of efficient registration algorithms are investigated. The first type comprises the additive registration algorithms: these algorithms incrementally compute the motion parameters by linearly approximating the brightness error function. We centre our attention on Hager and Belhumeur’s factorization-based algorithm for image registration. We propose a fundamental requirement that factorization-based algorithms must satisfy to guarantee good convergence, and introduce a systematic procedure that automatically computes the factorization. Finally, we also bring out two warp functions to register rigid and nonrigid 3D targets that satisfy the requirement. The second type comprises the compositional registration algorithms, where the brightness function error is written by using function composition. We study the current approaches to compositional image alignment, and we emphasize the importance of the Inverse Compositional method, which is known to be the most efficient image registration algorithm. We introduce a new algorithm, the Efficient Forward Compositional image registration: this algorithm avoids the necessity of inverting the warping function, and provides a new interpretation of the working mechanisms of the inverse compositional alignment. By using this information, we propose two fundamental requirements that guarantee the convergence of compositional image registration methods. Finally, we support our claims by using extensive experimental testing with synthetic and real-world data. We propose a distinction between image registration and tracking when using efficient algorithms. We show that, depending whether the fundamental requirements are hold, some efficient algorithms are eligible for image registration but not for tracking.
Resumo:
La mayoría de las estructuras de hormigón pretensadas construidas en los últimos 50 años han demostrado una excelente durabilidad cuando su construcción se realiza atendiendo las recomendaciones de un buen diseño así como una buena ejecución y puesta en obra de la estructura. Este hecho se debe en gran parte al temor que despierta el fenómeno de la corrosión bajo tensión típico de las armaduras de acero de alta resistencia. Menos atención se ha prestado a la susceptibilidad a la corrosión bajo tensión de los anclajes de postensado, posiblemente debido a que se han reportado pocos casos de fallos catastróficos. El concepto de Tolerancia al Daño y la Mecánica de la Fractura en estructuras de Ingeniería Civil ha empezado a incorporarse recientemente en algunas normas de diseño y cálculo de estructuras metálicas, sin embargo, aún está lejos de ser asimilado y empleado habitualmente por los ingenieros en sus cálculos cuando la ocasión lo requiere. Este desconocimiento de los aspectos relacionados con la Tolerancia al Daño genera importantes gastos de mantenimiento y reparación. En este trabajo se ha estudiado la aplicabilidad de los conceptos de la Mecánica de la Fractura a los componentes de los sistemas de postensado empleados en ingeniería civil, empleándolo para analizar la susceptibilidad de las armaduras activas frente a la corrosión bajo tensiones y a la pérdida de capacidad portante de las cabezas de anclajes de postensado debido a la presencia de defectos. Con este objeto se han combinado tanto técnicas experimentales como numéricas. Los defectos superficiales en los alambres de pretensado no se presentan de manera aislada si no que existe una cierta continuidad en la dirección axial así como un elevado número de defectos. Por este motivo se ha optado por un enfoque estadístico, que es más apropiado que el determinístico. El empleo de modelos estadísticos basados en la teoría de valores extremos ha permitido caracterizar el estado superficial en alambres de 5,2 mm de diámetro. Por otro lado la susceptibilidad del alambre frente a la corrosión bajo tensión ha sido evaluada mediante la realización de una campaña de ensayos de acuerdo con la actual normativa que ha permitido caracterizar estadísticamente su comportamiento. A la vista de los resultados ha sido posible evaluar como los parámetros que definen el estado superficial del alambre pueden determinar la durabilidad de la armadura atendiendo a su resistencia frente a la corrosión bajo tensión, evaluada mediante los ensayos que especifica la normativa. En el caso de las cabezas de anclaje de tendones de pretensado, los defectos se presentan de manera aislada y tienen su origen en marcas, arañazos o picaduras de corrosión que pueden producirse durante el proceso de fabricación, transporte, manipulación o puesta en obra. Dada la naturaleza de los defectos, el enfoque determinístico es más apropiado que el estadístico. La evaluación de la importancia de un defecto en un elemento estructural requiere la estimación de la solicitación local que genera el defecto, que permite conocer si el defecto es crítico o si puede llegar a serlo, si es que progresa con el tiempo (por fatiga, corrosión, una combinación de ambas, etc.). En este trabajo los defectos han sido idealizados como grietas, de manera que el análisis quedara del lado de la seguridad. La evaluación de la solicitación local del defecto ha sido calculada mediante el empleo de modelos de elementos finitos de la cabeza de anclaje que simulan las condiciones de trabajo reales de la cabeza de anclaje durante su vida útil. A partir de estos modelos numéricos se ha analizado la influencia en la carga de rotura del anclaje de diversos factores como la geometría del anclaje, las condiciones del apoyo, el material del anclaje, el tamaño del defecto su forma y su posición. Los resultados del análisis numérico han sido contrastados satisfactoriamente mediante la realización de una campaña experimental de modelos a escala de cabezas de anclaje de Polimetil-metacrilato en los que artificialmente se han introducido defectos de diversos tamaños y en distintas posiciones. ABSTRACT Most of the prestressed concrete structures built in the last 50 years have demonstrated an excellent durability when they are constructed in accordance with the rules of good design, detailing and execution. This is particularly true with respect to the feared stress corrosion cracking, which is typical of high strength prestressing steel wires. Less attention, however, has been paid to the stress corrosion cracking susceptibility of anchorages for steel tendons for prestressing concrete, probably due to the low number of reported failure cases. Damage tolerance and fracture mechanics concepts in civil engineering structures have recently started to be incorporated in some design and calculation rules for metallic structures, however it is still far from being assimilated and used by civil engineers in their calculations on a regular basis. This limited knowledge of the damage tolerance basis could lead to significant repair and maintenance costs. This work deals with the applicability of fracture mechanics and damage tolerance concepts to the components of prestressed systems, which are used in civil engineering. Such concepts have been applied to assess the susceptibility of the prestressing steel wires to stress corrosion cracking and the reduction of load bearing capability of anchorage devices due to the presence of defects. For this purpose a combination of experimental work and numerical techniques have been performed. Surface defects in prestressing steel wires are not shown alone, though a certain degree of continuity in the axial direction exist. A significant number of such defects is also observed. Hence a statistical approach was used, which is assumed to be more appropriate than the deterministic approach. The use of statistical methods based in extreme value theories has allowed the characterising of the surface condition of 5.2 mm-diameter wires. On the other hand the stress corrosion cracking susceptibility of the wire has been assessed by means of an experimental testing program in line with the current regulations, which has allowed statistical characterisasion of their performances against stress corrosion cracking. In the light of the test results, it has been possible to evaluate how the surface condition parameters could determine the durability of the active metal armour regarding to its resistance against stress corrosion cracking assessed by means of the current testing regulations. In the case of anchorage devices for steel tendons for prestressing concrete, the damage is presented as point defects originating from dents, scratches or corrosion pits that could be produced during the manufacturing proccess, transport, handling, assembly or use. Due to the nature of these defects, in this case the deterministic approach is more appropriate than the statistical approach. The assessment of the relevancy of defect in a structural component requires the computation of the stress intensity factors, which in turn allow the evaluation of whether the size defect is critical or could become critical with the progress of time (due to fatigue, corrosion or a combination of both effects). In this work the damage is idealised as tiny cracks, a conservative hypothesis. The stress intensity factors have been calculated by means of finite element models of the anchorage representing the real working conditions during its service life. These numeric models were used to assess the impact of some factors on the rupture load of the anchorage, such the anchorage geometry, material, support conditions, defect size, shape and its location. The results from the numerical analysis have been succesfully correlated against the results of the experimental testing program of scaled models of the anchorages in poly-methil methacrylate in which artificial damage in several sizes and locations were introduced.
Resumo:
This paper details an investigation into the appearance of hot-spots in two large grid-connected photovoltaics (PV) plants, which were detected after the visual inspection of trackers whose energy output was decreasing at anomalous rate. Detected hot-spots appeared not only in the solar cells but also in resistive solder bonds (RSB) between cells and contact ribbons. Both types cause similar irreversible damage to the PV modules, but the latter are the main responsible for the detected decrease in energy output, which was confirmed in an experimental testing campaign. The results of this investigation, for example, how hot-spots were detected or their impact on the output power of PV modules, may be of interest for the routine maintenance of large grid-connected PV plants.
Resumo:
Satellites and space equipment are exposed to diffuse acoustic fields during the launch process. The use of adequate techniques to model the response to the acoustic loads is a fundamental task during the design and verification phases. Considering the modal density of each element is necessary to identify the correct methodology. In this report selection criteria are presented in order to choose the correct modelling technique depending on the frequency ranges. A model satellite’s response to acoustic loads is presented, determining the modal densities of each component in different frequency ranges. The paper proposes to select the mathematical method in each modal density range and the differences in the response estimation due to the different used techniques. In addition, the methodologies to analyse the intermediate range of the system are discussed. The results are compared with experimental testing data obtained in an experimental modal test.
Resumo:
At present, photovoltaic energy is one of the most important renewable energy sources. The demand for solar panels has been continuously growing, both in the industrial electric sector and in the private sector. In both cases the analysis of the solar panel efficiency is extremely important in order to maximize the energy production. In order to have a more efficient photovoltaic system, the most accurate understanding of this system is required. However, in most of the cases the only information available in this matter is reduced, the experimental testing of the photovoltaic device being out of consideration, normally for budget reasons. Several methods, normally based on an equivalent circuit model, have been developed to extract the I-V curve of a photovoltaic device from the small amount of data provided by the manufacturer. The aim of this paper is to present a fast, easy, and accurate analytical method, developed to calculate the equivalent circuit parameters of a solar panel from the only data that manufacturers usually provide. The calculated circuit accurately reproduces the solar panel behavior, that is, the I-V curve. This fact being extremely important for practical reasons such as selecting the best solar panel in the market for a particular purpose, or maximize the energy extraction with MPPT (Maximum Peak Power Tracking) methods.
Resumo:
Son numerosos los expertos que predicen que hasta pasado 2050 no se utilizarán masivamente las energías de origen renovable, y que por tanto se mantendrá la emisión de dióxido de carbono de forma incontrolada. Entre tanto, y previendo que este tipo de uso se mantenga hasta un horizonte temporal aún más lejano, la captura, concentración y secuestro o reutilización de dióxido de carbono es y será una de las principales soluciones a implantar para paliar el problema medioambiental causado. Sin embargo, las tecnologías existentes y en desarrollo de captura y concentración de este tipo de gas, presentan dos limitaciones: las grandes cantidades de energía que consumen y los grandes volúmenes de sustancias potencialmente dañinas para el medioambiente que producen durante su funcionamiento. Ambas razones hacen que no sean atractivas para su implantación y uso de forma extensiva. La solución planteada en la presente tesis doctoral se caracteriza por la ausencia de residuos producidos en la operación de captura y concentración del dióxido de carbono, por no utilizar substancias químicas y físicas habituales en las técnicas actuales, por disminuir los consumos energéticos al carecer de sistemas móviles y por evitar la regeneración química y física de los materiales utilizados en la actualidad. Así mismo, plantea grandes retos a futuras innovaciones sobre la idea propuesta que busquen fundamentalmente la disminución de la energía utilizada durante su funcionamiento y la optimización de sus componentes principales. Para conseguir el objetivo antes citado, la presente tesis doctoral, una vez establecido el planteamiento del problema al que se busca solución (capítulo 1), del estudio de las técnicas de separación de gases atmosféricos utilizadas en la actualidad, así como del de los sistemas fundamentales de las instalaciones de captura y concentración del dióxido de carbono (capítulo 2) y tras una definición del marco conceptual y teórico (capítulo 3), aborda el diseño de un prototipo de ionización fotónica de los gases atmosféricos para su posterior separación electrostática, a partir del estudio, adaptación y mejora del funcionamiento de los sistemas de espectrometría de masas. Se diseñarán y desarrollarán los sistemas básicos de fotoionización, mediante el uso de fuentes de fotones coherentes, y los de separación electrostática (capítulo 4), en que se basa el funcionamiento de este sistema de separación de gases atmosféricos y de captura y concentración de dióxido de carbono para construir un prototipo a nivel laboratorio. Posteriormente, en el capítulo 5, serán probados utilizando una matriz experimental que cubra los rangos de funcionamiento previstos y aporte suficientes datos experimentales para corregir y desarrollar el marco teórico real, y con los que se pueda establecer y corregir un modelo físico– matemático de simulación (capítulo 6) aplicable a la unidad en su conjunto. Finalmente, debido a la utilización de unidades de ionización fotónica, sistemas láseres intensos y sistemas eléctricos de gran potencia, es preciso analizar el riesgo biológico a las personas y al medioambiente debido al impacto de la radiación electromagnética producida (capítulo 7), minimizando su impacto y cumpliendo con la legislación vigente. En el capítulo 8 se planteará un diseño escalable a tamaño piloto de la nueva tecnología propuesta y sus principales modos de funcionamiento, así como un análisis de viabilidad económica. Como consecuencia de la tesis doctoral propuesta y del desarrollo de la unidad de separación atmosférica y de captura y concentración de dióxido de carbono, surgen diversas posibilidades de estudio que pueden ser objeto de nuevas tesis doctorales y de futuros desarrollos de ingeniería. El capítulo 9 tratará de incidir en estos aspectos indicando líneas de investigación para futuras tesis y desarrollos industriales. ABSTRACT A large number of experts predict that until at least 2050 renewable energy sources will not be massively used, and for that reason, current Primary Energy sources based on extensive use of fossil fuel will be used maintaining out of control emissions, Carbon Dioxide above all. Meanwhile, under this scenario and considering its extension until at least 2050, Carbon Capture, Concentration, Storage and/or Reuse is and will be one of the main solutions to minimise Greenhouse Gasses environmental effect. But, current Carbon Capture and Storage technology state of development has two main problems: it is a too large energy consuming technology and during normal use it produces a large volume of environmentally dangerous substances. Both reasons are limiting its development and its extensive use. This Ph Degree Thesis document proposes a solution to get the expected effect using a new atmospheric gasses separation system with the following characteristics: absence of wastes produced, it needs no chemical and/or physical substances during its operation, it reduces to minimum the internal energy consumptions due to absence of mobile equipment and it does not need any chemical and/or physical regeneration of substances. This system is beyond the State of the Art of current technology development. Additionally, the proposed solution raises huge challenges for future innovations of the proposed idea finding radical reduction of internal energy consumption during functioning, as well as regarding optimisation of main components, systems and modes of operation. To achieve this target, once established the main problem, main challenge and potential solving solutions (Chapter 1), it is established an initial starting point fixing the Atmospheric Gasses Separation and Carbon Capture and Storage developments (Chapter 2), as well as it will be defined the theoretical and basic model, including existing and potential new governing laws and mathematical formulas to control its system functioning (Chapter 3), this document will deal with the design of an installation of an operating system based on photonic ionization of atmospheric gasses to be separated in a later separation system based on the application of electrostatic fields. It will be developed a basic atmospheric gasses ionization prototype based on intense radioactive sources capable to ionize gasses by coherent photonic radiation, and a basic design of electrostatic separation system (Chapter 4). Both basic designs are the core of the proposed technology that separates Atmospheric Gasses and captures and concentrates Carbon Dioxide. Chapter 5 will includes experimental results obtained from an experimental testing matrix covering expected prototype functioning regimes. With the obtained experimental data, theoretical model will be corrected and improved to act as the real physical and mathematical model capable to simulate real system function (Chapter 6). Finally, it is necessary to assess potential biological risk to public and environment due to the proposed use of units of intense energy photonic ionization, by laser beams or by non–coherent sources and large electromagnetic systems with high energy consumption. It is necessary to know the impact in terms of and electromagnetic radiation taking into account National Legislation (Chapter 7). On Chapter 8, an up scaled pilot plant will be established covering main functioning modes and an economic feasibility assessment. As a consequence of this PhD Thesis, a new field of potential researches and new PhD Thesis are opened, as well as future engineering and industrial developments (Chapter 9).
Resumo:
This research on odometry based GPS-denied navigation on multirotor Unmanned Aerial Vehicles is focused among the interactions between the odometry sensors and the navigation controller. More precisely, we present a controller architecture that allows to specify a speed specified flight envelope where the quality of the odometry measurements is guaranteed. The controller utilizes a simple point mass kinematic model, described by a set of configurable parameters, to generate a complying speed plan. For experimental testing, we have used down-facing camera optical-flow as odometry measurement. This work is a continuation of prior research to outdoors environments using an AR Drone 2.0 vehicle, as it provides reliable optical flow on a wide range of flying conditions and floor textures. Our experiments show that the architecture is realiable for outdoors flight on altitudes lower than 9 m. A prior version of our code was utilized to compete in the International Micro Air Vehicle Conference and Flight Competition IMAV 2012. The code will be released as an open-source ROS stack hosted on GitHub.
Resumo:
In this work the thermal analysis of a small satellite orbiting around the Earth has been approached by direct integration of the heat balance equations of a two-node reduced model, obtaining a linearized second order ODE problem, similar in form to the classical case of the forced vibration of a damped system. As the thermal loads (solar radiation, albedo, etc.) are harmonic, the problem is solved by means of Fourier analysis methods. Research on that field can be directly applied to the analysis of thermal problems and the results obtained are satisfactory. Working on the frequency domain streamlines the analysis, simplifies the study and facilitates the experimental testing. The transfer functions are obtained for the two-node case but the study can be extended to an n-node model.
Resumo:
El presente trabajo de investigación determina las características de la cerámica que más eficientemente se comporta a evaporación y a enfriamiento. Con el objeto de ser empleado como material integrado en la envolvente de los edificios para reducir su carga de refrigeración. La cerámica es un buen material para ser empleado para la refrigeración por evaporación. Es un sólido poroso inerte que, tras ser sometido a cocción a temperaturas por encima de los 900ºC, resulta uno de los materiales que mejor se comportan como contenedor de agua en su red capilar para, posteriormente, ir liberándola por evaporación al mismo tiempo que se enfría su superficie. La metodología general de investigación, se divide en tres etapas: Búsqueda y análisis del estado de la técnica y de la investigación. Estudio teórico de la eficacia del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura. Etapa experimental, desarrollada en tres fases: una primera de definición de los parámetros determinantes del Enfriamiento Evaporativo en piezas cerámicas, una segunda de selección cerámica y diseño de ensayos experimentales y una tercera de caracterización de la cerámica bajo criterios de evaporación y de enfriamiento. El recorrido por el estado de la cuestión ha identificado las aplicaciones tecnológicas y las investigaciones científicas que emplean el Enfriamiento Evaporativo con piezas cerámicas como técnica de enfriamiento. Como resultado se ha obtenido una tabla de clasificación de sistemas de enfriamiento evaporativo y se ha constatado que el conjunto de las aplicaciones están centradas en el diseño de piezas o sistemas pero que, sin embargo, no existe una definición de las características de la cerámica para su empleo como material de enfriamiento por evaporación. El estudio teórico de la eficacia del empleo del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura se ha realizado mediante cálculos de porcentaje de ampliación de horas en confort con empleo de técnicas de enfriamiento evaporativo directo e indirecto (EED y EEI). Como resultado se obtienen unos mapas para el ámbito español de potencial de aplicación del EED y EEI. Los resultados permiten afirmar que mediante EE se puede llegar a confort en prácticamente la totalidad de las horas de los días más cálidos del año en muchas localidades. La metodología experimental se ha desarrollado en tres fases. En la fase inicial, se han definido los parámetros determinantes del enfriamiento evaporativo en un medio cerámico mediante ensayos experimentales de capacidad de evaporación y de caracterización. Se realizaron un total de 12 ensayos. Se determinó que el material cerámico tiene una gran influencia en la capacidad de evaporación y enfriamiento en las piezas cerámicas, apoyando la hipótesis inicial y la necesidad de caracterizar el material. La primera fase empírica se centró en la selección cerámica y el diseño de los ensayos experimentales de comportamiento hídrico. Se seleccionaron muestras de 5 tipos de cerámica. Se realizaron 4 tipos de ensayos de caracterización y 6 tipos de ensayos experimentales de comportamiento hídrico (total 123 muestras ensayadas). Los resultados obtenidos son de dos tipos, por un lado, se determinó cuál es el tipo de cerámica que más eficientemente se comporta a EE y, por otro, se rediseñaron los ensayos de la última fase experimental. Para la segunda fase experimental se seleccionaron cerámicas de fabricación manual abarcando el mayor número de localidades del ámbito español. Se realizaron ensayos de caracterización de 7 tipos y ensayos de comportamiento hídrico de 5 tipos (total 197 muestras ensayadas). Los resultados de caracterización han permitido aportar unos rangos de las características de la cerámica que más eficientemente se comporta en los ensayos de comportamiento hídrico. Al final de la investigación se ha caracterizado el material cerámico aportando características acerca de su porosidad, capacidad de absorción, color, rugosidad y mineralogía. Así como datos de referencia de su comportamiento hídrico. Además se ha desarrollado una metodología de ensayo específica que permite evaluar la capacidad de enfriamiento eficiente de una pieza cerámica. ABSTRACT The purpose of this research is to determine the characteristics of ceramic materials having the most efficient performance in terms of evaporation and cooling, so that they can be integrated in building envelopes to reduce cooling loads. Ceramics are suitable materials for cooling through passive evaporation. After being fired at temperatures over 900 °C (1,652 °F), the capillary network of this inert porous medium turns to be excellent to retain water, which is progressively liberated by evaporation while the material surface gets colder. Research methodology has involved the following steps: Search and analysis on the state of the art in technology and research. Theoretical study on the efficiency of evaporation as passive cooling strategies in buildings. Experimental stage developed in three phases, namely: definition of parameters determining evaporative cooling in ceramic elements; ceramic selection and design of experimental tests; characterization of ceramic materials under evaporation and cooling criteria. Search and analysis on the state of the art in this field have been useful to identify technology applications and scientific research where ceramics are employed for evaporative cooling. The resulting table shows that applications are wholly focused on the design of pieces and systems. Nonetheless, there is lack of definition of material characteristics in this scope. The theoretical study on efficiency of the passive strategy applied to buildings has been realized by calculation of the percentage increase in comfort hours through direct/indirect evaporative cooling techniques (DEC/IEC). The mapping of their potential application in Spain clearly shows that comfort conditions can be reached in almost all the hours of the hottest days in many towns. In the initial phase of the experimental stage, parameters determining evaporative cooling in ceramic media have been defined. For this purpose, characterization tests and evaporation and cooling rates experiments have been carried out; the number of samples tested amounted to 12. It has been concluded that material characteristics have great influence on these rates, which supports the initial hypothesis and the need for their characterization. The first empirical phase has focused on ceramic selection and design of water behaviour experimental methods. The samples covered five different kinds of ceramic materials. Four different characterization tests and six different water behaviour experiments were carried out; the number of samples tested amounted to 123. The experimental testing procedures served to determine the most efficient types of ceramic materials in terms of evaporative cooling efficiency and, at the same time, made it necessary to change the original designed experimental test for the last phase. In the second phase, a number of varied hand-made ceramic tiles have been selected. Seven different characterization tests and five different water behaviour tests were carried out; the number of samples amounted to 197. The results of characterization served to establish a range of features in ceramic materials according to their efficiency in water behaviour experiments. Finally, ceramic materials have been characterized according to porosity, water absorption, colour, surface roughness and mineralogy. Also, reference data regarding water behaviour have been included. Moreover, an innovative and specific experimental test to evaluate cooling efficiency of ceramic tiles has been developed.
Resumo:
It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12°C-36°C and a maximum horizontal radiation of 1020 W/m2. Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 °C lower on the facade, while the bare wall temperature was 15 °C higher. The living wall module temperature was 1.6 °C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature.
Resumo:
The number of online real-time streaming services deployed over network topologies like P2P or centralized ones has remarkably increased in the recent years. This has revealed the lack of networks that are well prepared to respond to this kind of traffic. A hybrid distribution network can be an efficient solution for real-time streaming services. This paper contains the experimental results of streaming distribution in a hybrid architecture that consist of mixed connections among P2P and Cloud nodes that can interoperate together. We have chosen to represent the P2P nodes as Planet Lab machines over the world and the cloud nodes using a Cloud provider's network. First we present an experimental validation of the Cloud infrastructure's ability to distribute streaming sessions with respect to some key streaming QoS parameters: jitter, throughput and packet losses. Next we show the results obtained from different test scenarios, when a hybrid distribution network is used. The scenarios measure the improvement of the multimedia QoS parameters, when nodes in the streaming distribution network (located in different continents) are gradually moved into the Cloud provider infrastructure. The overall conclusion is that the QoS of a streaming service can be efficiently improved, unlike in traditional P2P systems and CDN, by deploying a hybrid streaming architecture. This enhancement can be obtained by strategic placing of certain distribution network nodes into the Cloud provider infrastructure, taking advantage of the reduced packet loss and low latency that exists among its datacenters.
Resumo:
The use of photovoltaic experimental plants in engineering educational buildings contributes to an increase in acceptance of this technology by future engineers. There are some photovoltaic (PV) systems in educational buildings in Spain, but they are usually limited to buildings in relation to electrical technologies or research areas. They are not common in other educational or official buildings. This paper presents the project of a grid-connected solar plant with two main objectives. First, different PV module technologies will be compared. Second, an emphasis on agronomical areas in educational settings will be reviewed in an attempt to facilitate student engagement in the use of the power plant. The system is grid-connected in order to pay-back the investment in the plant. In fact the electricity generated by the plant will be used by the installations of the building, as it is the closest consumer. This work intends to approximate photovoltaic technology to university degrees not directly related with it and at the same time research in comparison of systems with different technologies. This is a good example of an solar plant for both optimum production and educational purposes.
Resumo:
We have designed and implemented a framework that unifies unit testing and run-time verification (as well as static verification and static debugging). A key contribution of our approach is that a unified assertion language is used for all of these tasks. We first propose methods for compiling runtime checks for (parts of) assertions which cannot be verified at compile-time via program transformation. This transformation allows checking preconditions and postconditions, including conditional postconditions, properties at arbitrary program points, and certain computational properties. The implemented transformation includes several optimizations to reduce run-time overhead. We also propose a minimal addition to the assertion language which allows defining unit tests to be run in order to detect possible violations of the (partial) specifications expressed by the assertions. This language can express for example the input data for performing the unit tests or the number of times that the unit tests should be repeated. We have implemented the framework within the Ciao/CiaoPP system and effectively applied it to the verification of ISO-prolog compliance and to the detection of different types of bugs in the Ciao system source code. Several experimental results are presented that ¡Ilústrate different trade-offs among program size, running time, or levéis of verbosity of the messages shown to the user.