30 resultados para Electric power production -- Water consumption.
em Universidad Politécnica de Madrid
Resumo:
Many efforts have been made in order to adequate the production of a solar thermal collector field to the consumption of domestic hot water of the inhabitants of a building. In that sense, much has been achieved in different domains: research agencies, government policies and manufacturers. However, most of the design rules of the solar plants are based on steady state models, whereas solar irradiance, consumption and thermal accumulation are inherently transient processes. As a result of this lack of physical accuracy, thermal storage tanks are sometimes left to be as large as the designer decides without any aforementioned precise recommendation. This can be a problem if solar thermal systems are meant to be implemented in nowadays buildings, where there is a shortage of space. In addition to that, an excessive storage volume could not result more efficient in many residential applications, but costly, extreme in space consumption and in some cases too heavy. A proprietary transient simulation program has been developed and validated with a detailed measurement campaign in an experimental facility. In situ environmental data have been obtained through a whole year of operation. They have been gathered at intervals of 10 min for a solar plant of 50 m2 with a storage tank of 3 m3, including the equipment for domestic hot water production of a typical apartment building. This program has been used to obtain the design and dimensioning criteria of DHW solar plants under daily transient conditions throughout a year and more specifically the size of the storage tank for a multi storey apartment building. Comparison of the simulation results with the current Spanish regulation applicable, “Código Técnico de la Edificación” (CTE 2006), offers fruitful details and establishes solar facilities dimensioning criteria.
Resumo:
The estimation of power losses due to wind turbine wakes is crucial to understanding overall wind farm economics. This is especially true for large offshore wind farms, as it represents the primary source of losses in available power, given the regular arrangement of rotors, their generally largerdiameter and the lower ambient turbulence level, all of which conspire to dramatically affect wake expansion and, consequently, the power deficit. Simulation of wake effects in offshore wind farms (in reasonable computational time) is currently feasible using CFD tools. An elliptic CFD model basedon the actuator disk method and various RANS turbulence closure schemes is tested and validated using power ratios extracted from Horns Rev and Nysted wind farms, collected as part of the EU-funded UPWIND project. The primary focus of the present work is on turbulence modeling, as turbulent mixing is the main mechanism for flow recovery inside wind farms. A higher-order approach, based on the anisotropic RSM model, is tested to better take into account the imbalance in the length scales inside and outside of the wake, not well reproduced by current two-equation closure schemes.
Resumo:
El accidente de pérdida de refrigerante (LOCA) en un reactor nuclear es uno de los accidentes Base de Diseño más preocupantes y estudiados desde el origen del uso de la tecnología de fisión en la industria productora de energía. El LOCA ocupa, desde el punto de vista de los análisis de seguridad, un lugar de vanguardia tanto en el análisis determinista (DSA) como probabilista (PSA), cuya diferenciada perspectiva ha ido evolucionando notablemente en lo que al crédito a la actuación de las salvaguardias y las acciones del operador se refiere. En la presente tesis se aborda el análisis sistemático de de las secuencias de LOCA por pequeña y mediana rotura en diferentes lugares de un reactor nuclear de agua a presión (PWR) con fallo total de Inyección de Seguridad de Alta Presión (HPSI). Tal análisis ha sido desarrollado en base a la metodología de Análisis Integrado de Seguridad (ISA), desarrollado por el Consejo de Seguridad Nuclear (CSN) y consistente en la aplicación de métodos avanzados de simulación y PSA para la obtención de Dominios de Daño, que cuantifican topológicamente las probabilidades de éxito y daño en función de determinados parámetros inciertos. Para la elaboración de la presente tesis, se ha hecho uso del código termohidráulico TRACE v5.0 (patch 2), avalado por la NRC de los EEUU como código de planta para la simulación y análisis de secuencias en reactores de agua ligera (LWR). Los objetivos del trabajo son, principalmente: (1) el análisis exhaustivo de las secuencias de LOCA por pequeña-mediana rotura en diferentes lugares de un PWR de tres lazos de diseño Westinghouse (CN Almaraz), con fallo de HPSI, en función de parámetros de gran importancia para los transitorios, tales como el tamaño de rotura y el tiempo de retraso en la respuesta del operador; (2) la obtención y análisis de los Dominios de Daño para transitorios de LOCA en PWRs, de acuerdo con la metodología ISA; y (3) la revisión de algunos de los resultados genéricos de los análisis de seguridad para secuencias de LOCA en las mencionadas condiciones. Los resultados de la tesis abarcan tres áreas bien diferenciadas a lo largo del trabajo: (a) la fenomenología física de las secuencias objeto de estudio; (b) las conclusiones de los análisis de seguridad practicados a los transitorios de LOCA; y (c) la relevancia de las consecuencias de las acciones humanas por parte del grupo de operación. Estos resultados, a su vez, son de dos tipos fundamentales: (1) de respaldo del conocimiento previo sobre el tipo de secuencias analizado, incluido en la extensa bibliografía examinada; y (2) hallazgos en cada una de las tres áreas mencionadas, no referidos en la bibliografía. En resumidas cuentas, los resultados de la tesis avalan el uso de la metodología ISA como método de análisis alternativo y sistemático para secuencias accidentales en LWRs. ABSTRACT The loss of coolant accident (LOCA) in nuclear reactors is one of the most concerning and analized accidents from the beginning of the use of fission technology for electric power production. From the point of view of safety analyses, LOCA holds a forefront place in both Deterministic (DSA) and Probabilistic Safety Analysis (PSA), which have significantly evolved from their original state in both safeguard performance credibility and human actuation. This thesis addresses a systematic analysis of small and medium LOCA sequences, in different places of a nuclear Pressurized Water Reactor (PWR) and with total failure of High Pressure Safety Injection (HPSI). Such an analysis has been grounded on the Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Regulatory Body (CSN). ISA involves the application of advanced methods of simulation and PSA for obtaining Damage Domains that topologically quantify the likelihood of success and damage regarding certain uncertain parameters.TRACE v5.0 (patch 2) code has been used as the thermalhydraulic simulation tool for the elaboration of this work. Nowadays, TRACE is supported by the US NRC as a plant code for the simulation and analysis of sequences in light water reactors (LWR). The main objectives of the work are the following ones: (1) the in-depth analysis of small and medium LOCA sequences in different places of a Westinghouse three-loop PWR (Almaraz NPP), with failed HPSI, regarding important parameters, such as break size or delay in operator response; (2) obtainment and analysis of Damage Domains related to LOCA transients in PWRs, according to ISA methodology; and (3) review some of the results of generic safety analyses for LOCA sequences in those conditions. The results of the thesis cover three separated areas: (a) the physical phenomenology of the sequences under study; (b) the conclusions of LOCA safety analyses; and (c) the importance of consequences of human actions by the operating crew. These results, in turn, are of two main types: (1) endorsement of previous knowledge about this kind of sequences, which is included in the literature; and (2) findings in each of the three aforementioned areas, not reported in the reviewed literature. In short, the results of this thesis support the use of ISA-like methodology as an alternative method for systematic analysis of LWR accidental sequences.
Resumo:
The traditional power grid is just a one-way supplier that gets no feedback data about the energy delivered, what tariffs could be the most suitable ones for customers, the shifting daily needs of electricity in a facility, etc. Therefore, it is only natural that efforts are being invested in improving power grid behavior and turning it into a Smart Grid. However, to this end, several components have to be either upgraded or created from scratch. Among the new components required, middleware appears as a critical one, for it will abstract all the diversity of the used devices for power transmission (smart meters, embedded systems, etc.) and will provide the application layer with a homogeneous interface involving power production and consumption management data that were not able to be provided before. Additionally, middleware is expected to guarantee that updates to the current metering infrastructure (changes in service or hardware availability) or any added legacy measuring appliance will get acknowledged for any future request. Finally, semantic features are of major importance to tackle scalability and interoperability issues. A survey on the most prominent middleware architectures for Smart Grids is presented in this paper, along with an evaluation of their features and their strong points and weaknesses.
Resumo:
Crop production has a great contribution to water use and abstraction. Sugar beet is an important crop in irrigated land in Spain and covers 70.000 Ha. Crop and resources management are key factors for a sustainable agriculture. The aim of this work is to mode the sugar beet crop growth and water consumption in order to quantify crop water use and virtual water content in different growing conditions.
Resumo:
El objetivo del presente trabajo es determinar la localización óptima de una planta de producción de 30.000 m3/año de bioetanol a partir de tubérculos de pataca (Helianthus tuberosus L.) cultivada en regadío, en tierras de barbecho de la Cuenca Hidrográfica del Duero (CH Duero). Inicialmente se elaboró, a partir de datos bibliográficos, un modelo de producción de pataca en base a una ecuación de regresión que relaciona datos experimentales de rendimientos de variedades tardías con variables agroclimáticas. Así se obtuvo una función de producción basada en la cantidad de agua disponible (precipitación efectiva + dosis de riego) y en la radiación global acumulada en el periodo brotación‐senescencia del cultivo. A continuación se estima la superficie potencial de cultivo de pataca en la CH Duero a partir de la superficie arable en regadío cartografiada por el Sistema de Ocupación del Suelo (SIOSE), a la cual se le aplican, en base a los requerimientos del cultivo, unas restricciones climáticas, edafológicas, topográficas y logísticas mediante el uso de Sistemas de Información Geográfica (SIG). La proporción de superficie de regadío restringida se cuantifica a escala municipal con el fin de calcular la superficie de barbecho en regadío apta para el cultivo de pataca. A partir de las bases de datos georreferenciadas de precipitación, radiación global, y la dotación de agua para el riego de cultivos no específicos establecida en el Plan Hidrológico de la Cuenca del Duero a escala comarcal, se estimó la producción potencial de tubérculos de pataca sobre la superficie de barbecho de regadío según el modelo de producción elaborado. Así, en las 53.360 ha de barbecho en regadío aptas para el cultivo de pataca se podrían producir 3,8 Mt de tubérculos al año (80 % de humedad) (761.156 t ms/año) de los que se podría obtener 304.462 m3/año de bioetanol, considerando un rendimiento en la transformación de 12,5 kg mf/l de etanol. Se estiman los costes de las labores de cultivo de pataca así como los costes de la logística de suministro a una planta de transformación considerando una distancia media de transporte de 25 km, en base a las hojas de cálculo de utilización de aperos y maquinaria agrícola oficiales del Ministerio de Agricultura, Alimentación y Medio Ambiente (MAGRAMA). Considerando el balance de costes asociados a la producción de bioetanol (costes de transformación, distribución y transporte del producto, costes estructurales de la planta, ahorro de costes por la utilización de las vinazas generadas en el proceso como fertilizante y un beneficio industrial), se ha estimado que el coste de producción de bioetanol a partir de tubérculos de pataca asciende a 61,03 c€/l. Se calculan los beneficios fiscales para el Estado por el cultivo de 5.522 ha de pataca que suministren la materia prima necesaria para una planta de bioetanol de 30.000 m3/año, en concepto de cotizaciones a la Seguridad Social de los trabajadores, impuestos sobre el valor añadido de los productos consumidos, impuesto sobre sociedades y ahorro de las prestaciones por desempleo. Se obtuvieron unos beneficios fiscales de 10,25 c€ por litro de bioetanol producido. El coste de producción de bioetanol depende del rendimiento de tubérculos por hectárea y de la distancia de transporte desde las zonas de producción de la materia prima hasta la planta. Se calculó la distancia máxima de transporte para que el precio de coste del bioetanol producido sea competitivo con el precio de mercado del bioetanol. Como resultado se determinó que el precio del bioetanol (incluido un beneficio industrial del 15%) de la planta sería igual o inferior al precio de venta en el mercado (66,35 c€/l) con una distancia máxima de transporte de 25 km y un rendimiento mínimo del cultivo de 60,1 t mf/ha. Una vez conocido el área de influencia de la planta según la distancia de transporte máxima, se determinó la localización óptima de la planta de producción de bioetanol mediante un proceso de ubicación‐asignación realizado con SIG. Para ello se analizan los puntos candidatos a la ubicación de la planta según el cumplimiento de unos requerimientos técnicos establecidos (distancia a fuentes de suministro eléctrico y de recursos hídricos, distancia a estaciones de ferrocarril, distancia a núcleos urbanos y existencia de Espacios Naturales Protegidos) que minimizan la distancia de transporte maximizando la cantidad de biomasa disponible según la producción potencial estimada anteriormente. Por último, la superficie destinada al cultivo de pataca en el área de influencia de la planta se determina en base a un patrón de distribución del cultivo alrededor de una agroindustria. Dicho patrón se ha obtenido a partir del análisis del grado de ocupación del cultivo de la remolacha en función de la distancia de transporte a la planta azucarera de Miranda de Ebro (Burgos). El patrón resultante muestra que la relación entre el grado de ocupación del suelo por el cultivo y la distancia de transporte a la planta siguen una ecuación logística. La localización óptima que se ha obtenido mediante la metodología descrita se ubica en el municipio leonés de El Burgo Ranero, donde la producción potencial de tubérculos de pataca en la superficie de barbecho situada en un radio de acción de 25 km es de 375.665 t mf/año, superando las 375.000 t mf requeridas anualmente por la planta de bioetanol. ABSTRACT Jerusalem artichoke (Helianthus tuberosus L.) is a harsh crop with a high potential for biomass production. Its main use is related to bioethanol production from the carbohydrates, inulin mainly, accumulated in its tubers at the end of the crop cycle. The aerial biomass could be used as solid biofuel to provide energy to the bioethanol production process. Therefore, Jerusalem artichoke is a promising crop as feedstock for biofuel production in order to achieve the biofuels consumption objectives established by the Government of Spain (PER 2011‐2020 and RDL 4/2013) and the European Union (Directive 2009/28/EC). This work aims at the determination of the optimal location for a 30,000 m3/year bioethanol production plant from Jerusalem artichoke tubers in the Duero river basin. With this purpose, a crop production model was developed by means of a regression equation that relates experimental yield data of late Jerusalem artichoke varieties with pedo‐climatic parameters from a bibliographic data matrix. The resulting crop production model was based on the crop water availability (including effective rainfall and irrigation water supplied) and on global radiation accumulated in the crop emergence‐senescence period. The crop potential cultivation area for Jerusalem artichoke in the Duero basin was estimated using the georeferenced irrigated arable land from the “Sistema de Ocupación del Suelo” (SIOSE) of Spain. Climatic, soil, slope and logistic restrictions were considered by means of Geographic Information Systems (GIS). The limited potential growing area was then applied to a municipality scale in order to calculate the amount of fallow land suitable for Jerusalem artichoke production. Rainfall and global radiation georeferenced layers as well as data of irrigation water supply for crop production (established within the Duero Hydrologic Plan) were use to estimate the potential production of Jerusalem artichoke tubers in the suitable fallow land according to the crop production model. As a result of this estimation, there are 53,360 ha of fallow land suitable for Jerusalem artichoke production in the Duero basin, where 3.8 M t fm/year could be produced. Considering a bioethanol processing yield of 12.5 kg mf per liter of bioethanol, the above mentioned tuber potential production could be processed in 304,462 m3/year of bioethanol. The Jerusalem crop production costs and the logistic supply costs (considering an average transport distance of 25 km) were estimated according to official agricultural machinery cost calculation sheets of the Minister of Agriculture of Spain (MAGRAMA). The bioethanol production cost from Jerusalem artichoke tubers was calculated considering bioethanol processing, transport and structural costs, industrial profits as well as plant cost savings from the use of vinasses as fertilizer. The resulting bioetanol production cost from Jerusalem artichoke tubers was 61.03 c€/l. Additionally, revenues for the state coffers regarding Social Security contributions, added value taxes of consumed raw materials, corporation tax and unemployment benefit savings due to the cultivation of 5,522 ha of Jerusalem artichoke for the 30.000 m3/year bioethanol plant supply were calculated. The calculated revenues amounted to 10.25 c€/l. Bioethanol production cost and consequently the bioethanol plant economic viability are strongly related to the crop yield as well as to road transport distance from feedstock production areas to the processing plant. The previously estimated bioethanol production cost was compared to the bioethanol market price in order to determine the maximum supply transport distance and the minimum crop yield to reach the bioethanol plant economic viability. The results showed that the proposed plant would be economically viable at a maximum transport distance of 25 km and at a crop yield not less than 60.1 t fm/ha. By means of a GIS location‐allocation analysis, the optimal bioethanol plant location was determined. Suitable candidates were detected according to several plant technical requirements (distance to power and water supply sources, distance to freight station, and distance to urban areas and to Natural Protected Areas). The optimal bioethanol plant location must minimize the supply transport distance whereas it maximizes the amount of available biomass according to the previously estimated biomass potential production. Lastly, the agricultural area around the bioethanol plant finally dedicated to Jerusalem artichoke cultivation was planned according to a crop distribution model. The crop distribution model was established from the analysis of the relation between the sugar beet (Beta vulgaris L.) cropping area and the road transport distance from the sugar processing plant of Miranda de Ebro (Burgos, North of Spain). The optimal location was situated in the municipality of ‘El Burgo Ranero’ in the province of León. The potential production of Jerusalem artichoke tubers in the fallow land within 25 km distance from the plant location was 375,665 t fm/year, which exceeds the amount of biomass yearly required by the bioethanol plant.
Resumo:
This study reports the results of a water footprint (WF) assessment of five types of textiles commonly used for the production of jeans, including two different fibres (cotton and Lyocell fibre) and five corresponding production methods for spinning, dyeing and weaving. The results show that the fibre production is the stage with the highest water consumption, being cotton production particularly relevant. Therefore, the study pays particular attention to the water footprint of cotton production and analyses the effects of external factors influencing the water footprint of a product, in this case, the incentives provided by the EU Common Agricultural Policy (CAP), and the relevance of agricultural practices to the water footprint of a product is emphasised. An extensification of the crop production led to higher WF per unit, but a lower overall pressure on the basins water resources. This study performs a sustainability assessment of the estimated cotton WFs with the water scarcity index, as proposed by Hoekstra et al. (2011), and shows their variations in different years as a result of different water consumption by crops in the rest of the river basin. In our case, we applied the assessment to the Guadalquivir, Guadalete and Barbate river basins, three semi-arid rivers in South Spain. Because they are found to be relevant, the available water stored in dams and the outflow are also incorporated as reference points for the sustainability assessment. The study concludes that, in the case of Spanish cotton production, the situation of the basin and the policy impact are more relevant for the status of the basin s water resources than the actual WF of cotton production. Therefore, strategies aimed at reducing the impact of the water footprint of a product need to analyse both the WF along the value chain and within the local context.
Resumo:
In the last decade, research on irrigation has mainly been aimed at reducing crop water consumption. In arid and semi-arid environments, in relation to the limited water resources, the use of low quality water in agriculture has also been investigated in order to detect their effects on soil physical properties and on crop production. More recently, even the reduction of energy consumption in agriculture, as well as the effects of external factors, climate change and agricultural policies, have been major research interests. All these objectives have been considered in the papers included in this special issue. However, in the last years, approaches aimed at reducing crop water requirements have significantly changed. Remote sensing with satellites or unmanned vehicles, and vegetation spectral measurements, among others, represent in fact the newest frontier of existing technologies. Knowledge of soil hydraulic properties, often forgotten because of the difficulty of their estimation, can also be considered as a new way to reduce water consumption.
Resumo:
One of the main objectives of European Commission related to climate and energy is the well-known 20-20-20 targets to be achieved in 2020: Europe has to reduce greenhouse gas emissions of at least 20% below 1990 levels, 20% of EU energy consumption has to come from renewable resources and, finally, a 20% reduction in primary energy use compared with projected levels, has to be achieved by improving energy efficiency. In order to reach these objectives, it is necessary to reduce the overall emissions, mainly in transport (reducing CO2, NOx and other pollutants), and to increase the penetration of the intermittent renewable energy. A high deployment of battery electric (BEVs) and plug-in hybrid electric vehicles (PHEVs), with a low-cost source of energy storage, could help to achieve both targets. Hybrid electric vehicles (HEVs) use a combination of a conventional internal combustion engine (ICE) with one (or more) electric motor. There are different grades of hybridation from micro-hybrids with start-stop capability, mild hybrids (with kinetic energy recovery), medium hybrids (mild hybrids plus energy assist) and full hybrids (medium hybrids plus electric launch capability). These last types of vehicles use a typical battery capacity around 1-2 kWh. Plug in hybrid electric vehicles (PHEVs) use larger battery capacities to achieve limited electric-only driving range. These vehicles are charged by on-board electricity generation or either plugging into electric outlets. Typical battery capacity is around 10 kWh. Battery Electric Vehicles (BEVs) are only driven by electric power and their typical battery capacity is around 15-20 kWh. One type of PHEV, the Extended Range Electric Vehicle (EREV), operates as a BEV until its plug-in battery capacity is depleted; at which point its gasoline engine powers an electric generator to extend the vehicle's range. The charging of PHEVs (including EREVs) and BEVs will have different impacts to the electric grid, depending on the number of vehicles and the start time for charging. Initially, the lecture will start analyzing the electrical power requirements for charging PHEVs-BEVs in Flanders region (Belgium) under different charging scenarios. Secondly and based on an activity-based microsimulation mobility model, an efficient method to reduce this impact will be presented.
Resumo:
El sistema de energía eólica-diesel híbrido tiene un gran potencial en la prestación de suministro de energía a comunidades remotas. En comparación con los sistemas tradicionales de diesel, las plantas de energía híbridas ofrecen grandes ventajas tales como el suministro de capacidad de energía extra para "microgrids", reducción de los contaminantes y emisiones de gases de efecto invernadero, y la cobertura del riesgo de aumento inesperado del precio del combustible. El principal objetivo de la presente tesis es proporcionar nuevos conocimientos para la evaluación y optimización de los sistemas de energía híbrido eólico-diesel considerando las incertidumbres. Dado que la energía eólica es una variable estocástica, ésta no puede ser controlada ni predecirse con exactitud. La naturaleza incierta del viento como fuente de energía produce serios problemas tanto para la operación como para la evaluación del valor del sistema de energía eólica-diesel híbrido. Por un lado, la regulación de la potencia inyectada desde las turbinas de viento es una difícil tarea cuando opera el sistema híbrido. Por otro lado, el bene.cio económico de un sistema eólico-diesel híbrido se logra directamente a través de la energía entregada a la red de alimentación de la energía eólica. Consecuentemente, la incertidumbre de los recursos eólicos incrementa la dificultad de estimar los beneficios globales en la etapa de planificación. La principal preocupación del modelo tradicional determinista es no tener en cuenta la incertidumbre futura a la hora de tomar la decisión de operación. Con lo cual, no se prevé las acciones operativas flexibles en respuesta a los escenarios futuros. El análisis del rendimiento y simulación por ordenador en el Proyecto Eólico San Cristóbal demuestra que la incertidumbre sobre la energía eólica, las estrategias de control, almacenamiento de energía, y la curva de potencia de aerogeneradores tienen un impacto significativo sobre el rendimiento del sistema. En la presente tesis, se analiza la relación entre la teoría de valoración de opciones y el proceso de toma de decisiones. La opción real se desarrolla con un modelo y se presenta a través de ejemplos prácticos para evaluar el valor de los sistemas de energía eólica-diesel híbridos. Los resultados muestran que las opciones operacionales pueden aportar un valor adicional para el sistema de energía híbrida, cuando esta flexibilidad operativa se utiliza correctamente. Este marco se puede aplicar en la optimización de la operación a corto plazo teniendo en cuenta la naturaleza dependiente de la trayectoria de la política óptima de despacho, dadas las plausibles futuras realizaciones de la producción de energía eólica. En comparación con los métodos de valoración y optimización existentes, el resultado del caso de estudio numérico muestra que la política de operación resultante del modelo de optimización propuesto presenta una notable actuación en la reducción del con- sumo total de combustible del sistema eólico-diesel. Con el .n de tomar decisiones óptimas, los operadores de plantas de energía y los gestores de éstas no deben centrarse sólo en el resultado directo de cada acción operativa, tampoco deberían tomar decisiones deterministas. La forma correcta es gestionar dinámicamente el sistema de energía teniendo en cuenta el valor futuro condicionado en cada opción frente a la incertidumbre. ABSTRACT Hybrid wind-diesel power systems have a great potential in providing energy supply to remote communities. Compared with the traditional diesel systems, hybrid power plants are providing many advantages such as providing extra energy capacity to the micro-grid, reducing pollution and greenhouse-gas emissions, and hedging the risk of unexpected fuel price increases. This dissertation aims at providing novel insights for assessing and optimizing hybrid wind-diesel power systems considering the related uncertainties. Since wind power can neither be controlled nor accurately predicted, the energy harvested from a wind turbine may be considered a stochastic variable. This uncertain nature of wind energy source results in serious problems for both the operation and value assessment of the hybrid wind-diesel power system. On the one hand, regulating the uncertain power injected from wind turbines is a difficult task when operating the hybrid system. On the other hand, the economic profit of a hybrid wind-diesel system is achieved directly through the energy delivered to the power grid from the wind energy. Therefore, the uncertainty of wind resources has increased the difficulty in estimating the total benefits in the planning stage. The main concern of the traditional deterministic model is that it does not consider the future uncertainty when making the dispatch decision. Thus, it does not provide flexible operational actions in response to the uncertain future scenarios. Performance analysis and computer simulation on the San Cristobal Wind Project demonstrate that the wind power uncertainty, control strategies, energy storage, and the wind turbine power curve have a significant impact on the performance of the system. In this dissertation, the relationship between option pricing theory and decision making process is discussed. A real option model is developed and presented through practical examples for assessing the value of hybrid wind-diesel power systems. Results show that operational options can provide additional value to the hybrid power system when this operational flexibility is correctly utilized. This framework can be applied in optimizing short term dispatch decisions considering the path-dependent nature of the optimal dispatch policy, given the plausible future realizations of the wind power production. Comparing with the existing valuation and optimization methods, result from numerical example shows that the dispatch policy resulting from the proposed optimization model exhibits a remarkable performance in minimizing the total fuel consumption of the wind-diesel system. In order to make optimal decisions, power plant operators and managers should not just focus on the direct outcome of each operational action; neither should they make deterministic decisions. The correct way is to dynamically manage the power system by taking into consideration the conditional future value in each option in response to the uncertainty.
Resumo:
Growing scarcity, increasing demand and bad management of water resources are causing weighty competition for water and consequently managers are facing more and more pressure in an attempt to satisfy users? requirement. In many regions agriculture is one of the most important users at river basin scale since it concentrates high volumes of water consumption during relatively short periods (irrigation season), with a significant economic, social and environmental impact. The interdisciplinary characteristics of related water resources problems require, as established in the Water Framework Directive 2000/60/EC, an integrated and participative approach to water management and assigns an essential role to economic analysis as a decision support tool. For this reason, a methodology is developed to analyse the economic and environmental implications of water resource management under different scenarios, with a focus on the agricultural sector. This research integrates both economic and hydrologic components in modelling, defining scenarios of water resource management with the goal of preventing critical situations, such as droughts. The model follows the Positive Mathematical Programming (PMP) approach, an innovative methodology successfully used for agricultural policy analysis in the last decade and also applied in several analyses regarding water use in agriculture. This approach has, among others, the very important capability of perfectly calibrating the baseline scenario using a very limited database. However one important disadvantage is its limited capacity to simulate activities non-observed during the reference period but which could be adopted if the scenario changed. To overcome this problem the classical methodology is extended in order to simulate a more realistic farmers? response to new agricultural policies or modified water availability. In this way an economic model has been developed to reproduce the farmers? behaviour within two irrigation districts in the Tiber High Valley. This economic model is then integrated with SIMBAT, an hydrologic model developed for the Tiber basin which allows to simulate the balance between the water volumes available at the Montedoglio dam and the water volumes required by the various irrigation users.
Resumo:
The aim of this study was to evaluate the effects of row orien¬tation on vine and soil water status in an irrigated vineyard. The trial was developed during 2006, 2007 and 2008, in the South East region of Madrid (Spain) on 5-year old Cabernet franc grapevines (Vitis vinifera L.) grafted onto 140Ru. Plant spacing was 2.5 m x 1.5 m and vines were trained to a VSP. Four orientations were stu¬died: North-South (N-S), East-West (E-W), Northeast-Southwest (N+45) and North-South +20o (N+20). Irrigation (0.4•ET0) started when shoot growth stopped. Soil water availability was measured using a TDR technique with forty buried probes. Row orientation did not have any effect on water consumption in the vineyard. At maturity, leaf water potential was measured at predawn, early mor¬ning, midday and 14:00 solar time, on both canopy sides - sun and shade – ; the early morning measurement was the one that better differentiated treatments. Leaf water potential was a good indica¬tor of plant water status. Differences between (N-S and E-W) and (N+20 and N+45) treatments were obtained both on sun and shade canopy sides, N+20 and N+45 having lower leaf water potentials then drier leaves. The water stress integral shows that N-S and E-W reach the end of maturation with a greater level of hydration than N+45 and N+20. As a whole, N+45 and N+20 orientations, without affecting too much the soil available water content, induce regularly more water stress to the vine at some periods, probably due to an higher sunlight interception in early morning which makes water limitation for the vine more early and thus more severe during the day.
Resumo:
In arid countries worldwide, social conflicts between irrigation-based human development and the conservation of aquatic ecosystems are widespread and attract many public debates. This research focuses on the analysis of water and agricultural policies aimed at conserving groundwater resources and maintaining rurallivelihoods in a basin in Spain's central arid region. Intensive groundwater mining for irrigation has caused overexploitation of the basin's large aquifer, the degradation of reputed wetlands and has given rise to notable social conflicts over the years. With the aim of tackling the multifaceted socio-ecological interactions of complex water systems, the methodology used in this study consists in a novel integration into a common platform of an economic optimization model and a hydrology model WEAP (Water Evaluation And Planning system). This robust tool is used to analyze the spatial and temporal effects of different water and agricultural policies under different climate scenarios. It permits the prediction of different climate and policy outcomes across farm types (water stress impacts and adaptation), at basin's level (aquifer recovery), and along the policies’ implementation horizon (short and long run). Results show that the region's current quota-based water policies may contribute to reduce water consumption in the farms but will not be able to recover the aquifer and will inflict income losses to the rural communities. This situation would worsen in case of drought. Economies of scale and technology are evidenced as larger farms with cropping diversification and those equipped with modern irrigation will better adapt to water stress conditions. However, the long-term sustainability of the aquifer and the maintenance of rurallivelihoods will be attained only if additional policy measures are put in place such as the control of illegal abstractions and the establishing of a water bank. Within the policy domain, the research contributes to the new sustainable development strategy of the EU by concluding that, in water-scarce regions, effective integration of water and agricultural policies is essential for achieving the water protection objectives of the EU policies. Therefore, the design and enforcement of well-balanced region-specific polices is a major task faced by policy makers for achieving successful water management that will ensure nature protection and human development at tolerable social costs. From a methodological perspective, this research initiative contributes to better address hydrological questions as well as economic and social issues in complex water and human systems. Its integrated vision provides a valuable illustration to inform water policy and management decisions within contexts of water-related conflicts worldwide.
Resumo:
En el presente proyecto se estudia la viabilidad, tanto técnica como económica, de la instalación de una planta de cogeneración, en una industria alimentaria en Aldaya (Valencia). El diseño de la central de cogeneración se basa en la demanda energética de la fábrica, atendiendo a los requisitos necesarios para acogerse al Régimen Especial de producción de energía eléctrica establecidos en el Real Decreto 661/2007, de 25 de mayo. En cuanto a la viabilidad económica, se ha elegido la alternativa de venta de electricidad a la red a tarifa, (a un precio fijo y regulado) con el fin de asegurar los ingresos en el estudio económico y reducir la sensibilidad del proyecto a las variables del mercado. Como resultado se obtienen la reducción de los costes de energía de la fábrica, mejora de la fiabilidad de suministro, reducción de emisiones globales de CO2, y una elevada rentabilidad del proyecto. ABSTRACT The aim of this project is to study the technical and economic feasibility of a cogeneration plant in a food industry in Aldaya (Valencia). The design of the cogeneration plant is based on the energetic demand of the factory, attending to the requirements specified in the Special Regime of production of electric power established in the R.D. 661/2007. The studied alternative in terms of economic viability is selling electricity to the net by tariff, which is a fixed and regulated price in order to assure the revenue in the economic study and to reduce the project sensitivity to the market variation. The results obtained are: reduction in energy costs of the fabric, improvement of reliability in the electrical supply, reduction of global CO2 emission, and high profitability of the project.
Resumo:
La situación actual del mercado energético en España y el imparable aumento de las tasas por parte de las eléctricas, está fomentando la búsqueda de fuentes de energía alternativas que permitan a la población poder abastecerse de electricidad, sin tener que pagar unos costes tan elevados. Para cubrir esta necesidad, la energía fotovoltaica y sobretodo el autoconsumo con inyección a red o balance neto, está adquiriendo cada vez más importancia dentro del mundo energético. Pero la penetración de esta tecnología en la Red Eléctrica Española tiene un freno, la desconfianza por parte del operador de la red, ya que la fotovoltaica es una fuente de energía intermitente, que puede introducir inestabilidades en el sistema en caso de alta penetración. Por ello se necesita ganar la confianza de las eléctricas, haciendo que sea una energía predecible, que aporte potencia a la red eléctrica cuando se le pida y que opere participando en la regulación de la frecuencia del sistema eléctrico. Para tal fin, el grupo de investigación de Sistemas Fotovoltaicos, perteneciente al IES de la UPM, está llevando a cabo un proyecto de investigación denominado PV CROPS, financiado por la Comisión Europea, y que tiene por objetivo desarrollar estas estrategias de gestión. En este contexto, el objetivo de este Proyecto Fin de Carrera consiste en implementar un Banco de Ensayos con Integración de Baterías en Sistemas FV Conectados a Red, que permita desarrollar, ensayar y validar estas estrategias. Aprovechando la disponibilidad para usar el Hogar Digital, instalado en la EUITT de la UPM, hemos montado el banco de ensayos en un laboratorio contiguo, y así, poder utilizar este Hogar como un caso real de consumos energéticos de una vivienda. Este banco de ensayos permitirá obtener información de la energía generada por la instalación fotovoltaica y del consumo real de la "casa" anexa, para desarrollar posteriormente estrategias de gestión de la electricidad. El Banco de Ensayos está compuesto por tres bloques principales, interconectados entre sí: Subsistema de Captación de Datos y Comunicación. Encargado de monitorizar los elementos energéticos y de enviar la información recopilada al Subsistema de Control. Formado por analizadores de red eléctrica, monofásicos y de continua, y una pasarela orientada a la conversión del medio físico Ethernet a RS485. Subsistema de Control. Punto de observación y recopilación de toda la información que proviene de los elementos energéticos. Es el subsistema donde se crearán y se implementarán estrategias de control energético. Compuesto por un equipo Pxie, controlador empotrado en un chasis de gama industrial, y un equipo PC Host, compuesto por una workstation y tres monitores. Subsistema de Energía. Formado por los elementos que generan, controlan o consumen energía eléctrica, en el Banco de Ensayos. Constituido por una pérgola FV, un inversor, un inversor bidireccional y un bloque de baterías. El último paso ha sido llevar a cabo un Ejemplo de Aplicación Práctica, con el que hemos probado que el Banco de Ensayos está listo para usarse, es operativo y completamente funcional en operaciones de monitorización de generación energética fotovoltaica y consumo energético. ABSTRACT. The current situation of the energetic market in Spain and the unstoppable increase of the tax on the part of the electrical companies, is promoting the search of alternative sources of energy that allow to the population being able to be supplied of electricity, without having to pay so high costs. To meet this need, the photovoltaic power and above all the self-consumption with injection to network, it is increasingly important inside the energetic world. It allows to the individual not only to pay less for the electricity, in addition it allows to obtain benefits for the energy generated in his own home. But the penetration of this technology in the Electrical Spanish Network has an obstacle, the distrust on the part of the operator of the electrical network, due to the photovoltaic is an intermittent source of energy, which can introduce instabilities in the system in case of high penetration. Therefore it´s necessary to reach the confidence of the electricity companies, making it a predictable energy, which provides with power to the electrical network whenever necessary and that operates taking part in the regulation of the frequency of the electric system. For such an end, the group of system investigation Photovoltaic, belonging to the IES of the UPM, there is carrying out a project of investigation named PV CROPS, financed by the European Commission, and that has for aim to develop these strategies of management. In this context, the objective of this Senior Thesis consists in implementing a Bank of Tests with Integration of Batteries in Photovoltaic Systems Connected to Network, which allows developing, testing and validating these strategies. Taking advantage of the availability to use the Digital Home installed in the EUITT of the UPM, we have mounted the bank of tests in a contiguous laboratory to use this Home as a real case of energetic consumptions of a house. This bank of tests will allow obtaining information of the energy generated by the photovoltaic installation and information of the royal consumption of the attached "house", to develop later strategies of management of the electricity. The Bank of Tests is composed by three principal blocks, interconnected each other: Subsystem of Gathering of data and Communication. In charge of monitoring the energetic elements and sending the information compiled to the Subsystem of Control. Formed by power analyzers, AC and DC, and a gateway for the conversion of the Ethernet physical medium to RS485. Subsystem of Control. Point of observation and compilation of all the information that comes from the energetic elements. It is the subsystem where there will be created and there will be implemented strategies of energetic control. Composed of a Pxie, controller fixed in an industrial range chassis, and a PC Host, formed by a workstation and three monitors. Subsystem of Energy. Formed by the elements of generating, controlling or consuming electric power, in the Bank of Tests. Made of photovoltaic modules, an inverter, a twoway inverter and a batteries block. The last step has been performing an Example of Practical Application we have proved that the Bank of Tests is ready to be used, it´s operative and fully functional in monitoring operations of energetic photovoltaic generation and energetic consumption.