3 resultados para Electric load shedding

em Universidad Politécnica de Madrid


Relevância:

80.00% 80.00%

Publicador:

Resumo:

An ED-tether mission to Jupiter is presented. A bare tether carrying cathodic devices at both ends but no power supply, and using no propellant, could move 'freely' among Jupiter's 4 great moons. The tour scheme would have current naturally driven throughout by the motional electric field, the Lorentz force switching direction with current around a 'drag' radius of 160,00 kms, where the speed of the jovian ionosphere equals the speed of a spacecraft in circular orbit. With plasma density and magnetic field decreasing rapidly with distance from Jupiter, drag/thrust would only be operated in the inner plasmasphere, current being near shut off conveniently in orbit by disconnecting cathodes or plugging in a very large resistance; the tether could serve as its own power supply by plugging in an electric load where convenient, with just some reduction in thrust or drag. The periapsis of the spacecraft in a heliocentric transfer orbit from Earth would lie inside the drag sphere; with tether deployed and current on around periapsis, magnetic drag allows Jupiter to capture the spacecraft into an elliptic orbit of high eccentricity. Current would be on at succesive perijove passes and off elsewhere, reducing the eccentricity by lowering the apoapsis progressively to allow visits of the giant moons. In a second phase, current is on around apoapsis outside the drag sphere, rising the periapsis until the full orbit lies outside that sphere. In a third phase, current is on at periapsis, increasing the eccentricity until a last push makes the orbit hyperbolic to escape Jupiter. Dynamical issues such as low gravity-gradient at Jupiter and tether orientation in elliptic orbits of high eccentricity are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A procedure for measuring the overheating temperature (ΔT ) of a p-n junction area in the structure of photovoltaic (PV) cells converting laser or solar radiations relative to the ambient temperature has been proposed for the conditions of connecting to an electric load. The basis of the procedure is the measurement of the open-circuit voltage (VO C ) during the initial time period after the fast disconnection of the external resistive load. The simultaneous temperature control on an external heated part of a PV module gives the means for determining the value of VO C at ambient temperature. Comparing it with that measured after switching OFF the load makes the calculation of ΔT possible. Calibration data on the VO C = f(T ) dependences for single-junction AlGaAs/GaAs and triple-junction InGaP/GaAs/Ge PV cells are presented. The temperature dynamics in the PV cells has been determined under flash illumination and during fast commutation of the load. Temperature measurements were taken in two cases: converting continuous laser power by single-junction cells and converting solar power by triple-junction cells operating in the concentrator modules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the impact of electric mobility on the transmission grid in Flanders region (Belgium), using a micro-simulation activity based models. These models are used to provide temporal and spatial estimation of energy and power demanded by electric vehicles (EVs) in different mobility zones. The increment in the load demand due to electric mobility is added to the background load demand in these mobility areas and the effects over the transmission substations are analyzed. From this information, the total storage capacity per zone is evaluated and some strategies for EV aggregator are proposed, allowing the aggregator to fulfill bids on the electricity markets.