3 resultados para ECKLONIA-CAVA

em Universidad Politécnica de Madrid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the 2009-10 year ten new degrees have begun to be taught at the UPM (Universidad Politécnica de Madrid), which is the first group of degrees that this University will offer within the framework of the EHEA (European Higher Education Area). One of these is the Building Engineering Degree, which was implemented in September 2009 in the EUATM (Escuela de Arquitectura Técnica de Madrid). It is heir to the former 'Arquitecto Técnico' degree that will become extinct as the new degree is successively implemented. This paper unveils the strategy that the EUATM management staff has designed and is developing, so that the complex process that involves the incorporation of our School into the model of 'Bologna', takes place smoothly and with guaranteed success

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis se enmarca dentro de una línea de investigación iniciada en el 2004 focalizada en el estudio de soluciones constructivas energéticamente eficientes para la crianza del vino. El objetivo principal es promover el ahorro energético y la sostenibilidad en el diseño de la sala de crianza de las bodegas. Para ello, se profundiza en el estudio de las bodegas subterráneas, ejemplo de eco-construcción, ya que por lo general proporcionan condiciones adecuadas para la crianza sin gasto energético en climatización. En concreto, se abordan aspectos clave para la caracterización y comprensión del funcionamiento de estas construcciones, que en muchas ocasiones condicionan el éxito o el fracaso de las mismas. Así, se analiza el complejo comportamiento de la ventilación natural a lo largo del año, determinando los factores que la condicionan, desvelando el papel que desempeña tanto el túnel de acceso como las chimeneas de ventilación en su funcionamiento. Además, se desarrollan y validan modelos de simulación mediante CFD, que permiten evaluar y predecir con detalle el comportamiento termofluidodinámico de las construcciones subterráneas. Por otra parte, se cuantifica la uniformidad y estabilidad de la sala de crianza a lo largo del año, información que permite fijar recomendaciones y pautas concretas de diseño de los planes de monitorización. Finalmente, se determinan las diferencias de comportamiento higrotérmico existentes entre un amplio abanico de bodegas subterráneas para vino tinto, bodegas representativas de otras soluciones constructivas alternativas de vino tinto, así como bodegas para cavas y vinos generosos, enmarcando el comportamiento de estas bodegas en un contexto global. Además, se desarrollan metodologías adaptadas a las características particulares de estas construcciones, en concreto un sistema de monitorización basado en termografía infrarroja para llevar a cabo inspecciones puntuales para el control ambiental de grandes naves de crianza. Es de esperar que los estudios técnicos y las herramientas desarrolladas ayuden a mejorar el diseño de nuevas bodegas, y a la mejora de las condiciones higrotérmicas de las ya existentes, colaborando a que España siga situada en la vanguardia de la producción de vino de calidad. ABSTRACT This thesis is part of the research started in 2004 and focusing on the study of the energy efficiency in wine aging constructive solutions. The main objective is to promote energy conservation and sustainability in the design of wine aging rooms. To do so, this study focuses on the analysis of the underground cellars, example of eco-construction, since they usually provide adequate conditions for wine aging without using air-conditioning systems. In particular, key aspects for characterizing and understanding these constructions, which often determine the success or failure of them. Thus, the complex behavior of natural ventilation throughout the year is discussed, determining the influencing factors and revealing the role of both the access tunnel and the ventilation chimney. In addition, numerical models are developed and validated using CFD simulation, allowing an in-depth assessment and prediction of the thermofluidynamic behavior in underground constructions. Moreover, uniformity and stability of the aging room throughout the year is quantified, allowing for precise information useful to set recommendations and design guidelines for defining monitoring plans. Finally, hygrothermal behavior differences between a wide range of underground cellars for red wine, red wine wineries with alternative construction solutions and wineries for generous wines and cava wines, In addition, new methodologies adapted towards the particular characteristics of these constructions, a monitoring system based on infrared thermography to perform periodic inspections for environmental controls of the aging rooms, are developed. It is expected that the technical studies and tools developed here will help to improve the design of new wineries, and also the hygrothermal conditions of the existing ones, headed for keeping Spain in the forefront of the countries producing high quality wine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to analyze a complex high lift configuration for which significant regions of separated flow are present. Current state of the art methods have some diffculty to predict the origin and the progression of this separated flow when increasing the angle of attack. The mechanisms responsible for the maximum lift limit on multi-element wing con?gurations are not clear; this stability analysis could help to understand the physics behind the phenomenon and to find a relation between the flow separation and the instability onset. The methodology presented herein consists in the computation of a steady base flow solution based on a finite volume discretization and a proposal of the solution for a generalized eigenvalue problem corresponding to the perturbed and linearized problem. The eigenvalue problem has been solved with the Arnoldi iterative method, one of the Krylov subspace projection methods. The described methodology was applied to the NACA0012 test case in subsonic and in transonic conditions and, finally, for the first time to the authors knowledge, on an industrial multi-component geometry, such as the A310 airfoil, in order to identify low frequency instabilities related to the separation. One important conclusion is that for all the analyzed geometries, one unstable mode related to flow separation appears for an angle of attack greater than the one correspondent to the maximum lift coe?cient condition. Finally, an adjoint study was carried out in order to evaluate the receptivity and the structural sensitivity of the geometries, giving an indication of the domain region that could be modified resulting in the biggest change of the flowfield.