4 resultados para Demand-Response
em Universidad Politécnica de Madrid
Resumo:
Predictions about electric energy needs, based on current electric energy models, forecast that the global energy consumption on Earth for 2050 will double present rates. Using distributed procedures for control and integration, the expected needs can be halved. Therefore implementation of Smart Grids is necessary. Interaction between final consumers and utilities is a key factor of future Smart Grids. This interaction is aimed to reach efficient and responsible energy consumption. Energy Residential Gateways (ERG) are new in-building devices that will govern the communication between user and utility and will control electric loads. Utilities will offer new services empowering residential customers to lower their electric bill. Some of these services are Smart Metering, Demand Response and Dynamic Pricing. This paper presents a practical development of an ERG for residential buildings.
Resumo:
En los últimos años se ha construido un gran número de pasarelas peatonales como respuesta a la demanda de nuevas vías de paso en las ciudades. Estas estructuras tienen requisitos constructivos menos exigentes en comparación con otros tipos de puentes, lo cual ha facilitado el desarrollo de diseños con nuevos esquemas resistentes, complicadas geometrías y el empleo de nuevos materiales. En general estas estructuras son esbeltas, ligeras y poco amortiguadas, lo que en ocasiones ha generado problemas de vi-braciones al paso de peatones una vez puestas en servicio. Las normativas actuales son cada vez más sensibles a esta problemática, recomendando diseños cuyas frecuencias naturales deben estar alejadas de los rangos de frecuencia de paso típicos de los peatones y fijando límites de confort en forma de valores máximos de aceleración permitidos, asegurándose así un correcto comportamiento de la estructura. En el presente artículo se analiza esta problemática desde un punto de vista práctico. Para ello se muestran los puntos clave de las normativas y guías de diseño de pasarelas que se pueden encontrar actualmente en la bibliografía, se presentan las técnicas que habitualmente se emplean en el análisis dinámico experimental de estas estructuras, y se comentan las soluciones a las que generalmente se recurre para mejorar su comportamiento dinámico. Por último, se muestran los trabajos llevados a cabo por el Centro Tecnológico CARTIF en colaboración con las Universidades de Valladolid y Castilla-La Mancha en la pasarela peatonal del Museo de la Ciencia de Valladolid. Estos trabajos incluyen: (1) el estudio dinámico de los tres vanos metálicos de dicha pasarela, (2) el diseño e implementación de un amortiguador de masa sintonizado en el vano más sensible a las vibraciones, (3) la implementación de un amortiguador de masa activo utilizando un excitador electrodinámico, y (4) el desarrollo de pruebas para la verificación del estado de servicio de la pasarela. In the last years, a wide number of footbridges have been built as demand response of more direct pathways in cities. These structures have lower building requirements as compared with standard bridges. This circumstance has facilitated the development of new structural design with complex geometries and innovative materials. As a result, these structures may be slender, light and low damped, leading to vibration problems once in service. The current codes take into account this problem, and recommend designs with natural frequencies away from the typical pedestrian pacing rates and fix comfort limits to guarantee the serviceability of the structure.This paper studies this problem from a practical point of view. Thus, the key points of codes and footbridges guidelines are showed, the typical experimental dynamic analysis techniques are presented, and the usual solutions adopted to improve the dynamic performance of these structures are discussed. Finally, the works carried out on the Valladolid Science Museum Footbridge by Centro Tecnológico CARTIF in collaboration with the Universities of Valladolid and Castilla-La Mancha are showed. These works include: (1) the dynamic study of the three steel spans of the footbridge, (2) the design and implementation of a tuned mass damper in the liveliest span, (3) the implementation of an active mass damper using an electrodynamic shaker, and (4) the development of field tests to assess the serviceability of such span.
Resumo:
With recent technological developments within the field of power conditioning and the progressive decrease of incentives for PV electricity in grid-connected markets, new operation modes for PV systems should be explored beyond the traditional maximization of PV electri city feed-in. An example can be found in the domestic sector, where the use of modern PV hybrid systems combin ed with efficient electrical appliances and demand side management strategies can significantly enhance the PV value for the user. This paper presents an active demand side management system able to displace the consumer’s load curve in response to local (PV hybrid system, user) and external conditions (external grid). In this way, th e consumer becomes an “active consumer” that can also cooperate with others and the grid, increasing even more the PV value for the electrical system.
Resumo:
This paper discusses the torsional response of a scaled reinforced concrete frame structure subjected to several uniaxial shaking table tests. The tested structure is nominally symmetric in the direction of shaking and exhibits torsion attributable to non-uniform yielding of structural components and uncertainties in the building process. Asymmetric behavior is analyzed in terms of displacement, strain in reinforcing bars, energy dissipated at plastic hinges, and damage at section and frame levels. The results show that for low levels of seismic hazard, for which the structure is expected to perform basically within the elastic range, the accidental eccentricity is not a concern for the health of the structure, but it significantly increases the lateral displacement demand in the frames (about 30%) and this might cause significant damage to non-structural components. For high levels of seismic hazard the effects of accidental torsion become less important. These results underline the need to consider accidental eccentricity in evaluating the performance of a structure for very frequent or frequent earthquakes, and suggest that consideration of torsion may be neglected for performance levels associated with rare or very rare earthquakes.