5 resultados para Decay time
em Universidad Politécnica de Madrid
Resumo:
On the basis of optical characterization experiments and an eight band kp model, we have studied the effect of Sb incorporation on the electronic structure of InAs quantum dots (QDs). We have found that Sb incorporation in InAs QDs shifts the hole wave function to the center of the QD from the edges of the QD where it is otherwise pinned down by the effects of shear stress. The observed changes in the ground-state energy cannot merely be explained by a composition change upon Sb exposure but can be accounted for when the change in lateral size is taken into consideration. The Sb distribution inside the QDs produces distinctive changes in the density of states, particularly, in the separation between excitation shells. We find a 50% increase in the thermal escape activation energy compared with reference InAs quantum dots as well as an increment of the fundamental transition decay time with Sb incorporation. Furthermore, we find that Sb incorporation into quantum dots is strongly nonlinear with coverage, saturating at low doses. This suggests the existence of a solubility limit of the Sb incorporation into the quantum dots during growth.
Resumo:
El principal objetivo de este estudio es la evaluación de la distribución espacial de los parámetros acústicos en un recinto a través de la aplicación de técnicas geoestadísticas como el método Kriging. Mediante el uso de la herramienta de análisis espacial ArcMap, perteneciente a la plataforma ArcGIS, se ha analizado el comportamiento acústico del Salón de Actos común a la Escuela Técnica Superior de Ingeniería y Sistemas de Telecomunicación (ETSIST) y la Escuela Técnica Superior de Ingeniería de Sistemas Informáticos (ETSISI), ambas situadas en el Campus Sur de la Universidad Politécnica de Madrid. Se han realizado mediciones in-situ del recinto no ocupado utilizando la herramienta de medición DIRAC Room Acoustics y el método de la respuesta impulsiva integrada, extrayéndose los parámetros acústicos de tiempo de reverberación (RT), tiempo de reverberación inicial (EDT), fuerza sonora relativa (Grel), claridad (C80), tiempo central (Ts), definición (D50) e Índice de Transmisión Rápida de la Palabra (RASTI). Se ha analizado la adecuación de los valores observados de Grel, C80 y Ts al modelo teórico de Barron y estimado, mediante el método Kriging Ordinario, el conjunto de parámetros medidos en el recinto, obteniéndose los semivariograma y mapas de estimación correspondientes. Además, se ha evaluado la calidad de la estimación en base a un número de puntos de medición reducido. A la vista de los resultados obtenidos, en general, el método Kriging puede considerarse un buen interpolador de los parámetros acústicos en un recinto, observándose que los parámetros que evalúan relaciones energéticas, especialmente la fuerza sonora relativa (Grel) proporcionan mejores estimaciones en comparación con aquellos relacionados con la reverberación y la inteligibilidad del habla. El coeficiente de determinación (R2) constituye una medida útil para evaluar la precisión de la estimación. Además, la entropía de los datos observados puede ser un buen indicador a priori de la precisión de la estimación. Asimismo, se ha demostrado que, basándose en un reducido número de puntos de medición, es posible obtener una estimación precisa de los parámetros acústicos de fuerza sonora relativa (Grel) y tiempo central (Ts). ABSTRACT. This project aims to evaluate the feasibility of using geostatistical techniques such as Kriging on the analysis of the spatial distribution of the acoustic parameters in rooms. The acoustic behaviour of the Assembly Hall of the ETSIST and ETSISI (Universidad Politécnica de Madrid) is investigated using ArcMap, which is the main component of ArcGIS suite of geospatial processing programs. For this purpose, in-situ acoustic measurements are carried out in the unoccupied room using DIRAC Room Acoustics software. The following acoustic parameters are measured by means of the integrated impulse response method for further examination: Reverberation Time (RT), Early Decay Time (EDT), Relative Strength (Grel), Clarity (C80), Centre Time (Ts), Definition (D50) and Rapid Speech Transmission Index (RASTI). Goodness-of-fit of measured Grel, C80 and Ts values to Barron’s theory is determined and Ordinary Kriging is applied to all the measured parameters in order to calculate the semivariogram and prediction surfaces. The prediction performance is also analysed when significantly fewer receiver positions are used for the prediction. The experimental results obtained lead to conclude that Kriging can be successfully applied to room acoustics. Energy\based acoustic parameters can be estimated with higher accuracy compared to those related to reverberation and speech intelligibility. Coefficient of determination (R2) is a reliable statistic for assessing the prediction accuracy, for which measured data entropy can also be a good a priori indicator. Furthermore, based on fewer receiver positions, it is demonstrated that accurate predictions of Grel and Ts can be achieved.
Resumo:
A semiempirical method for predicting the damping efficiency of hysteresis rods on-board small satellites is presented. It is based on the evaluation of dissipating energy variation of different ferromagnetic materials for two different rod shapes: thin film and circular cross-section rods, as a function of their elongation. Based on this formulation, an optimum design considering the size of hysteresis rods, their cross section shape, and layout has been proposed. Finally, the formulation developed was applied to the case of four existing small satellites, whose corresponding in-flight data are published. A good agreement between the estimated rotational speed decay time and the in-flight data has been observed.
Resumo:
El trabajo fin de master “Análisis de la precisión en la medida del tiempo de reverberación y de los parámetros asociados” tiene como objetivo primordial la evaluación de los parámetros y métodos utilizados para la obtención de estos, a través del tiempo de reverberación, tanto de forma global, conjunto de todos los métodos, como cada uno de ellos por separado. Un objetivo secundario es la evaluación de la incertidumbre en función del método de medición usado. Para realizarlo, se van a aprovechar las mediciones realizadas para llevar a cabo el proyecto fin de carrera [1], donde se medía el tiempo de reverberación en dos recintos diferentes usando el método del ruido interrumpido y el método de la respuesta impulsiva integrada con señales distintas. Las señales que han sido utilizadas han sido señales impulsivas de explosión de globos, disparo de pistola, claquetas y, a través de procesado digital, señales periódicas pseudoaleatorias MLS y barridos de tonos puros. La evaluación que se realizará a cada parámetro ha sido extraída de la norma UNE 89002 [2], [3]y [4]. Se determinará si existen valores aberrantes tanto por el método de Grubbs como el de Cochran, e interesará conocer la veracidad, precisión, repetibilidad y reproducibilidad de los resultados obtenidos. Los parámetros que han sido estudiados y evaluados son el tiempo de reverberación con caída de 10 dB, (T10), con caída de 15 dB (T15), con caída de 20 dB (T20), con caída de 30 dB (T30), el tiempo de la caída temprana (EDT), el tiempo final (Ts), claridad (C20, C30, C50 y C80) y definición (D50 y D80). Dependiendo de si el parámetro hace referencia al recinto o si varía en función de la relación entre la posición de fuente y micrófono, su estudio estará sujeto a un procedimiento diferente de evaluación. ABSTRACT. The master thesis called “Analysis of the accuracy in measuring the reverberation time and the associated parameters” has as the main aim the assessment of parameters and methods used to obtain these through reverberation time, both working overall, set of all methods, as each of them separately. A secondary objective is to evaluate the uncertainty depending on the measurement method used. To do this, measurements of [1] will be used, where they were carried on in two different spaces using the interrupted noise method and the method of impulse response integrated with several signals. The signals that have been used are impulsive signals such as balloon burst, gunshot, slates and, through digital processing, periodic pseudorandom signal MLS and swept pure tone. The assessment that will be made to each parameter has been extracted from the UNE 89002 [2], [3] and [4]. It will determine whether there are aberrant values both through Grubbs method and Cochran method, to say so, if a value is inconsistent with the rest of the set. In addition, it is interesting to know the truthfulness, accuracy, repeatability and reproducibility of results obtained from the first part of this rule. The parameters that are going to be evaluated are reverberation time with 10 dB decay, (T10), with 15 dB decay (T15), with 20 dB decay (T20), with 30 dB decay (T30), the Early Decay Time (EDT), the final time (Ts), clarity (C20, C30, C50 y C80) and definition (D50 y D80). Depending on whether the parameter refers to the space or if it varies depending on the relationship between source and microphone positions, the study will be related to a different evaluation procedure.
Resumo:
This paper analyzes the correlation between the fluctuations of the electrical power generated by the ensemble of 70 DC/AC inverters from a 45.6 MW PV plant. The use of real electrical power time series from a large collection of photovoltaic inverters of a same plant is an impor- tant contribution in the context of models built upon simplified assumptions to overcome the absence of such data. This data set is divided into three different fluctuation categories with a clustering proce- dure which performs correctly with the clearness index and the wavelet variances. Afterwards, the time dependent correlation between the electrical power time series of the inverters is esti- mated with the wavelet transform. The wavelet correlation depends on the distance between the inverters, the wavelet time scales and the daily fluctuation level. Correlation values for time scales below one minute are low without dependence on the daily fluctuation level. For time scales above 20 minutes, positive high correlation values are obtained, and the decay rate with the distance depends on the daily fluctuation level. At intermediate time scales the correlation depends strongly on the daily fluctuation level. The proposed methods have been implemented using free software. Source code is available as supplementary material.